首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE: To ultrasonographically evaluate hemodynamics in the abdominal aorta (AAo) and splanchnic vessels in dogs with experimentally induced normovolemic anemia. ANIMALS: 11 healthy Beagles. PROCEDURE: The AAo, cranial mesenteric artery (CMA), celiac artery (CA), hilar splenic artery (HSA), and main portal vein (MPV) were evaluated in conscious dogs immediately before and after experimental induction of severe normovolemic anemia (Hct, 16%) and during recovery from moderate and mild anemia (Hct, 26% and 34%, respectively). Peak systolic velocity (PSV) or peak velocity (PV), time-averaged mean velocity (TAVmean), pulsatility index (PI), resistive index (RI), blood flow, congestion index (CI), and heart rate (HR) were recorded. Results were compared for anemic and control states. RESULTS: Severe anemia caused significant increases in HR (25% to 70%), PSV (AAo, 45.8%; CMA, 56.1%; and CA, 41.9%), PV (MPV, 84.2%), and TAVmean, (AAo, 69.4%, CMA, 64.3%; CA, 29.7%; and MPV, 76.9%) and significant decreases in PI (AAo, 26.1%; HSA, 19.3%) and Cl (MPV, 45.2%).There was no significant change in PI of the CMA or CA, portal blood flow, or RI of any artery. Significantly higherTAVmean persisted in all vessels during moderate anemia, but higher PSV persisted only in the CMA; PI (CMA and CA) and RI (CA) decreased significantly, but portal blood flow increased significantly. Significant increase in TAVmean (AAo and CMA) persisted during mild anemia, and PI (AAo, CMA, and HSA) and RI (CMA) were significantly lower. CONCLUSIONS AND CLINICAL RELEVANCE: Doppler ultrasonography revealed hyperdynamic circulation in the AAo and splanchnic vessels in dogs with experimentally induced normovolemic anemia.  相似文献   

2.
This study was performed to characterize the normal blood flow of the canine testis and to measure the peak systolic velocity (PSV), end-diastolic velocity (EDV), resistive index (RI) and pulsatility index (PI) of testicular arteries weekly during a period of 6 months in five healthy Beagle dogs and to evaluate whether there were any change along this time. The ultrasonographic exams were made with an 11 MHz linear transducer. The vessels of the testes were subdivided into three categories: supratesticular arteries, marginal artery and intratesticular vessels. At the supratesticular arteries, two measurements were recorded at the cranial and the looping parts. No significant differences in any of the parameters studied were observed for the 6 months that the study was performed. The cranial part of the supratesticular artery showed a flow pattern of high-resistive vessel, whereas in the looping part of the supratesticular artery, marginal and intratesticular arteries, the flow showed a low-resistance pattern. PSV, RI and PI values were higher at the cranial part of the supratesticular artery, followed by the looping part of the supratesticular artery, marginal and intratesticular vessels. EDV measurements were higher in the looping part of the supratesticular artery.  相似文献   

3.
Contrast‐enhanced ultrasound with sulphur hexafluoride microbubbles was performed in seven healthy dogs without a history of reproductive pathology and with histologically confirmed normal testes and in 42 dogs with chronic scrotal anomalies. All dogs underwent orchiectomy and histological examination. Enhancement patterns and perfusion parameters (peak intensity and regional blood flow) of testes of healthy dogs and testes with chronic lesions were compared. Fourteen non‐pathologic and 60 pathologic testes were considered. Forty testes were neoplastic (24 interstitial cell tumours, 9 seminomas, 7 Sertoli cell tumours), 20 were non‐neoplastic (16 testicular degenerations, 2 chronic orchitis, 1 testicular atrophy, 1 interstitial cell hyperplasia). In healthy dogs, the contrast medium flow had a rapid homogeneous wash‐in and wash‐out, with a short peak phase. With contrast ultrasound, testes that were inhomogeneous with a hyperenhancing pattern were associated with neoplasia (sensitivity: 87.5%, specificity: 100%). Lesions with persistent inner vessels and a hypo‐to‐isoechoic background were significantly associated with seminomas (sensitivity: 77.8%, specificity: 100%). Testes with non‐neoplastic lesions were characterized by a scant/moderate homogeneous enhancement. Perfusion parameters were higher in neoplastic lesions. Contrast ultrasound was a feasible diagnostic tool in the assessment of testicular lesions, with hyperenhancement being an important feature in the diagnosis of malignancy.  相似文献   

4.
OBJECTIVE: To determine the influence of age, body weight (BW), heart rate (HR), sex, and left ventricular shortening fraction (LVSF) on transmitral and pulmonary venous flow in clinically normal dogs. ANIMALS: 92 client-owned dogs 3 months to 19 years old. PROCEDURE: Transthoracic Doppler echocardiography recordings of transmitral flow and pulmonary venous flow were obtained in conscious unsedated dogs. Influence of age, BW, HR, sex, and LVSF on diastolic variables was assessed, using statistical methods such as ANOVA on ranks and univariate and multivariate forward stepwise linear regression analyses. RESULTS: Age significantly influenced isovolumic relaxation time (IVRT, r = 0.56), ratio between peak velocity of the early diastolic mitral flow wave-to-peak velocity of late diastolic mitral flow wave (E:A; r = -0.44), deceleration time of early diastolic mitral flow (DTE; r = 0.26), and peak velocity of atrial reversal pulmonary venous flow wave (AR-wave; r = 0.37). Significant changes of mitral inflow and pulmonary venous flow variables were evident only in dogs > 6 and > 10 years old, respectively. Body weight significantly influenced DTE (r = 0.63), late diastolic flow duration (r = 0.60), and AR duration (r = 0.47), whereas HR significantly affected DTE (r = -0.34), IVRT (r = -0.33), and peak velocity of AR (r = 0.24). Sex or LVSF (range 22 to 48%) did not influence any echocardiographic variables. CONCLUSIONS AND CLINICAL RELEVANCE: Age, BW, and HR are important factors that affect filling of the left atrium and left ventricle in clinically normal dogs.  相似文献   

5.
General anesthesia reduces hepatic blood flow (HBF) from circulatory depression. Total intravenous anesthesia (TIVA) is associated with decreased circulatory depression compared to inhalation anesthesia, and epidural anesthesia using local anesthetics increases blood flow by blocking the sympathetic nerves and expanding blood vessels. We investigated the effects of thoracolumbar epidural anesthesia with TIVA on HBF in dogs. Six Beagle dogs had epidural catheters placed between T13 and L1 and were anesthetized with propofol and vecuronium. Physiological saline (control) or 2% lidocaine (0.2 ml/kg, followed by 0.2 ml/kg/hr) was administered at 1–2 weeks intervals. Heart rate (HR), cardiac index (CI), mean arterial pressure (MAP), and systemic vascular resistance index (SVRI) were recorded at 10-min intervals from before epidural injections (T0) to 110 min. Indocyanine green test was used to measure HBF during the awake state and until 90 min after epidural injections. HR and CI did not differ between treatments. MAP and SVRI after lidocaine were significantly lower than those of controls, and the lowest MAP value was 65 ± 11 mmHg at T10. Compared to T0, after lidocaine treatment, HBF was significantly higher at T30, T60 and T90 (P<0.05); while, after control treatment, no significant change was evident at any time point. Despite a decrease in MAP by this technique, HBF was either maintained at pre-anesthetic levels or increased in comparison to controls, probably due to vasodilation of the hepatic artery induced by the selective blockade sympathetic ganglia.  相似文献   

6.
Two-dimensional ultrasound was used in combination with colour-coded and pulsed Doppler sonography to study the blood flow of the testes and prostate gland in a total of 30 male dogs. After detection of the vessels by colour-coded Doppler sonography, the blood flow patterns were determined by pulsed Doppler sonography measuring and describing the systolic and diastolic peak velocity (SPV, DPV), the end-diastolic velocity, the time-averaged maximum velocity (TAMAX), the pulsatility and resistance index, as well as the ratios of the systolic peak velocity and end-diastolic velocity and of the systolic and diastolic peak velocities. The blood flow of the testicular artery was measured within the pampiniform plexus and the marginal location. The prostatic blood supply was measured in the artery of the deferential duct (cranial), the prostatic artery outside (lateral) and within the gland (subcapsular). The physiological testicular flow pattern was monophasic with a high diastolic flow. Testes with neoplastic alterations showed a significant increase of SPV and TAMAX. The epididymal vessels could not be detected. Under physiological conditions the prostatic blood flow pattern was biphasic in the cranial and lateral location and monophasic in the subcapsular location. Benign prostatic hyperplasia was characterized by a significant increase of SPV, DPV and TAMAX. The results of the present investigation demonstrate that the colour-coded and pulsed Doppler sonography give additional valuable information which improves the andrological diagnostics in the dog.  相似文献   

7.
Isosorbide 5-mononitrate (5-ISMN) was evaluated in normal dogs and dogs with congestive heart failure (CHF) in a randomized, blinded, and placebo-controlled study. Equilibrium blood pool imaging was used to detect changes in regional blood volume distribution. Six normal dogs were administered placebo, 2, 3, and 4 mg/kg 5-ISMN PO on separate days with a 1-week washout period between randomized dosings. Six dogs with CHF were administered placebo or 4 mg/kg 5-ISMN on separate days with a 1-week washout period between randomized dosings. Data were collected at baseline and at 15, 30, 45, 60, 90, 120, 150, 180, 210, and 240 minutes after dosing. Measured variables included indirect arterial blood pressure (BP), heart rate (HR), packed cell volume (PCV), scintigraphic count rates for normal dogs, and scintigraphic count rates for CHF dogs. Blood for plasma 5-ISMN concentration determination was collected at 60 minutes. Scintigraphic counts were corrected for decay and expressed as a percentage of the whole. No differences were detected in BP, HR, PCV, thoracic blood volume percentage (TBVP), or abdominal blood volume percentage (ABVP) between placebo and 5-ISMN in normal dogs at any dose. No differences were detected in TBVP or ABVP between placebo and 5-ISMN in dogs with CHF Plasma 5-ISMN concentration exceeded the minimum therapeutic concentration in all dogs and at all doses 60 minutes after drug administration. Equilibrium blood pool imaging failed to detect a shift in blood volume with oral 5-ISMN administration at any dose tested in normal dogs and dogs with CHF, despite adequate drug absorption. On the basis of the results of this study, 5-ISMN may not be beneficial in the treatment of dogs with CHF.  相似文献   

8.
OBJECTIVE: To assess the effects of epidural anesthesia using lidocaine on microcirculatory blood flow, volume, and velocity in free fasciocutaneous flaps in dogs. Study Design-In vivo experimental investigation. Animal Population-Ten adult dogs weighing 20 to 25 kg. METHODS: A medial saphenous fasciocutaneous free flap was removed and an orthotopic transfer was performed by anastomosing the primary flap vessels back to the medial saphenous vessels. Blood flow (mL(LD)/min/100 g), volume (%volume or tissue hematocrit) and velocity (mm/s) in the flap were recorded throughout the procedure. After epidural anesthesia, blood flow, volume, and velocity values were again recorded. RESULTS: Microcirculatory blood flow, volume, and velocity, as measured by a laser-Doppler flowmeter, failed to reveal any significant changes over time. Immediately after epidural anesthesia, mean arterial pressure was significantly reduced and remained depressed throughout the experimental procedure. CONCLUSIONS: Epidural anesthesia combined with general anesthesia does not improve microcirculatory flow in free flaps in the pelvic limbs of dogs. No significant change in blood flow to the medial saphenous fasciocutaneous free flap occurred after division and anastomosis of the vascular pedicle. CLINICAL RELEVANCE: We recommend that epidural anesthesia with 2% lidocaine be used with caution in dogs undergoing microvascular free-flap transfer.  相似文献   

9.
The normal flow velocity profile and duplex Doppler waveform of the major abdominal blood vessels (aorta, caudal vena cava and the portal vein as well as their major branches) were examined by Doppler ultrasound. The flow velocity profile of an artery is largely determined by its diameter. The pulsatility of the waveform is related to the vascular impedance downstream to the point of measurement. Early systolic peak is present in the Doppler pattern of some vessels in some dogs. The waveform of the veins is mainly affected by the pressure conditions of the right atrium and the intrathoracic and intraabdominal pressure changes due to the respiration. Simultaneous electrocardiogram was used to reveal the effect of the heart beats on the Doppler patterns of the veins.  相似文献   

10.
The purpose of this study was to qualify and quantify the femoral artery blood flow by duplex Doppler ultrasonography (DDU) in healthy dogs, before and after the administration of a combination of acepromazine maleate and buprenorphine hydrochloride (ACP-BPN). Seven healthy adult mongrel dogs and three adult beagles were used. Heart rate, arterial blood pressure and measurement of femoral artery blood flow by DDU were also recorded. The DDU measurements were: femoral artery diameter (FAD), peak systolic velocity (PSV), early retrograde (EDV) and end diastolic velocities (EnDV), mean velocity (BMV), pulsatility index (PI), flow velocity integral (FVI) and femoral blood flow (FBF). After 30 min, combination ACP-BPN was administered intramuscularly, and all the measurements were recorded again. The ACP-BPN protocol induced a significant decrease in systolic, mean, and diastolic arterial blood pressure, and heart rate. A significant increase in peak systolic velocity and integral flow velocity integral of the femoral blood were obtained. The Doppler spectra of the blood flow in the femoral artery revealed a spectral dispersion pattern after ACP-BPN administration in all the dogs. These results demonstrate that despite quantitative and qualitative changes, the overall femoral blood flow (FBF) is not significantly modified.  相似文献   

11.
OBJECTIVE: To evaluate the effect of intravenous lidocaine on coughing and variations in heart rate (HR) and systolic arterial pressure (SAP) at endotracheal intubation in propofol-anaesthetized dogs. STUDY DESIGN: Prospective, randomized, blinded clinical study. ANIMALS: Eighty dogs, ASA grades I/II. METHODS: Dogs were randomly assigned to one of two treatments, with dogs in the lidocaine group receiving 1 mg kg(-1) lidocaine intravenously and those in the saline group receiving 0.05 mL kg(-1) saline intravenously before induction of anaesthesia with up to 6.5 mg kg(-1) propofol intravenously. An electrocardiogram was recorded continuously. Heart rate was calculated and SAP (using Doppler ultrasonic flow detection) was recorded at the following time points: pre-treatment, following lidocaine or saline administration, before and after intubation. The occurrence, number and strength of coughs were recorded. Systolic arterial pressure and HR were compared using one-sample t-tests to examine whether SAP and HR changed with test drug administration or following intubation. The number of coughs was compared between groups using t-tests. A cross tabulation and chi-square or Fisher's exact test was used to compare proportions of dogs that coughed and intensity of coughing in each group. The level of significance was set at p < 0.05. RESULTS: Heart rate did not change in either group. Systolic arterial blood pressure increased following intubation in both the lidocaine (p = 0.003) and saline groups (p = 0.001). There was no difference in the increase in SAP or in the number or intensity of coughs at intubation between groups. CONCLUSIONS AND CLINICAL RELEVANCE: Intravenous lidocaine had no effect on the occurrence or intensity of coughing or on changes in SAP at endotracheal intubation in dogs anaesthetized with propofol. The use of 1 mg kg(-1) lidocaine intravenously before intubation in dogs to attenuate cough and the pressor response was not supported.  相似文献   

12.
In an attempt to determine whether Trypanosoma congolense occurs both within and outside the blood vessels in an infected animal host, multimammate rats (Mastomys coucha) were infected with T. congolense and samples from spleen, lymph nodes, bone marrow, liver, kidney, lungs, brain, heart, intestines, ovaries and testes were collected. The tissue samples were fixed and processed for light and electron microscopical examination. In all the tissues examined, trypanosomes were found only within the lumen of large and small blood vessels, capillaries and sinuses. It is concluded that following entry into the blood circulation after intra-peritoneal infection of M. coucha, T. congolense remains restricted to the bloodstream.  相似文献   

13.
Colour-coded duplex sonography was used to examine the testes of 42 dogs whose testes were normal on clinical examination. With colour Doppler, the blood flow in the supratesticular region could be displayed clearly in 70 per cent of the cases, independent of the dog's age, bodyweight, pulse rate and the volume of its testes. The marginal artery could be displayed clearly in 56 per cent of the cases, and the clarity was correlated with bodyweight (P<0.001), testicular volume (P<0.001), and pulse rate (P<0.001). The intratesticular blood flow could not be discerned in 42 per cent of the cases. With pulsed Doppler, the mean resistive index (RI) in the supratesticular region was 0.57, and the mean pulsatility index (PI) was 1.00. In the marginal artery, the mean RI was 0.49, and mean PI was 0.78. In the intratesticular arteries, the mean RI was 0.47, and the mean PI was 0.75. At all three sites both indices were independent of age, bodyweight, pulse rate and testicular volume.  相似文献   

14.
IntroductionAlternatives for out-of-clinic heart rate (HR) measurement are required to optimise the management of atrial fibrillation (AF) in dogs. Additionally, the presence of circadian variation (CV) in HR in pet dogs remains unknown.We aimed to identify the number and duration of spot-checks required for an accurate estimation of 24-hour HR in canine AF. Circadian variation in HR was examined in healthy dogs and dogs with AF, and spot-check-derived HR was compared with a CV-derived gold standard.Materials and methodsAmbulatory electrocardiogram data from healthy dogs and dogs with AF were retrospectively analysed. Heart rate was calculated from the entire recording and pre-defined periods (spot-checks) of one hour to 30 and 60 s in duration. Circadian variation in HR was determined by cosinor analysis. Bias and limits of agreement of means and median HR with mesor HR were determined by correlation and Bland–Altman analysis.ResultsCircadian variation in HR was identified not only in 18/22 healthy dogs and 14/21 AF dogs but only on ambulatory electrocardiogram recordings.Four-hourly spot-checks provided the most accurate estimate of mesor HR in healthy dogs (bias of the median over 30 s 7.70, limits of agreement 7.48), whereas, in dogs with AF, four, six and eight-hourly spot-checks provided reliable estimates of mesor HR (bias within −1.29 and −29.5).ConclusionsFour, six and eight-hourly HR spot-checks can estimate 24-hourly HR in dogs with AF. There was CV in HR in most healthy pet dogs and dogs with AF. Spot-check protocols cannot identify CV in HR.  相似文献   

15.
This retrospective study was conducted to identify hemodynamic alterations associated with the administration of an ionic iodinated contrast media in dogs. Case records of 49 dogs that were anesthetized for computed tomography scanning were reviewed. Values for heart rate (HR) and direct arterial pressure were obtained. Overall, 37% of dogs had a ≥20% change in either HR or systolic arterial pressure from baseline values. Four dogs (8%) became tachycardic and two dogs (4%) became bradycardic. Eight dogs (16%) became hypertensive and two dogs (4%) became hypotensive. A significant proportion of dogs experienced changes in HR and blood pressure following IV administration of an ionic iodinated contrast media under general anesthesia.  相似文献   

16.
The objective of this study was to investigate the short-term cardiovascular effects of intravenous (IV) medetomidine-midazolam-fentanyl (MMF) injections in the rabbit using vascular ultrasonography and echocardiography.Anesthesia with MMF was induced intramuscularly (IM) in 8 female New Zealand White rabbits before 3 defined bolus injections of MMF were given IV. Before and for 10 min after each MMF injection the following vascular variables [at the left common carotid artery (ACC) after the first injection and at the abdominal aorta (AA) after the second injection]: vessel diameter (D), peak systolic, minimum diastolic, end-diastolic and average blood flow velocities (psBFV, mdBFV, edBFV, Vave), average volumetric flow (VFave), resistance index (RI) and pulsatility index (PI) and other clinical variables: mean arterial pressure (MAP), heart rate (HR), peripheral arterial oxygen saturation and end-tidal CO2 were recorded. Echocardiography was used after the third injection to investigate changes in cardiac parameters. Additionally, hemodynamic effects were observed at the ACC after complete subcutaneous antagonism of anesthesia by atipamezole-flumazenil-naloxone (AFN) until recovery of the animals.Medetomidine-midazolam-fentanyl IV caused a significant decrease of blood flow velocity in both investigated vessels which was associated with a significant decrease of HR and cardiac performance indicated by the decrease of FS and average volumetric blood flow. Mean arterial pressure significantly increased after each MMF injection; whereas, it significantly decreased after AFN injection. Therefore, MMF and AFN should be carefully used in rabbits and may not be suitable in patients with ventricular dysfunction.  相似文献   

17.
The purpose of this study was to evaluate efficacy of bromosulfophthalein (BSP) retention testing in dogs with and without histopathologically confirmed hepatobiliary disease. Medical records of 150 dogs with hepatobiliary disease having both a BSP test and hepatic biopsy were retrieved. Histopathologic slides of liver tissue were reviewed, and dogs were classified according to 1 of 11 histopathologic categories. Twenty-five clinically normal random-source dogs were used as controls for hepatic biopsy and BSP testing. No dogs suffered adverse effects due to BSP administration. BSP retention was significantly (P < .05) higher in hospitalized (13.9%) than control (3.2%) dogs, but the test could not distinguish between hospitalized dogs with different types of hepatobiliary disease. Sensitivity, specificity, and predictive values of BSP retention as a test for hepatic disease were calculated. Using 5.0% as a cutoff for normal BSP retention resulted in a specificity of 88% and a sensitivity of 76%. Using 6.0% as a cutoff for normal BSP retention resulted in a specificity of 100% and a sensitivity of 70%. Dogs of this study having BSP retention of >6% had at least an 86% chance of having an abnormal liver. We concluded that continued use of BSP retention testing is warranted as a noninvasive diagnostic test for liver disease in dogs.  相似文献   

18.
Exogenously administered vasopressors (sympathomimetics) were evaluated in isoflurane-anesthetized dogs to determine the effects of these drugs on cardiovascular function before and after hemorrhage. Six dogs were anesthetized with thiamylal sodium (20 mg/kg of body weight) and isoflurane (1.25 minimal alveolar concentration) in 100% oxygen. After instrumentation, cardiac output, systemic arterial blood pressure, heart rate (HR), left ventricular pressure, pulmonary arterial pressure, and an index of cardiac contractility (dP/dT) were measured. Stroke volume, cardiac index (CI), stroke index (SI), rate-pressure product, and systemic vascular resistance (SVR) were calculated. Epinephrine (0.1, 0.3, and 0.5 micrograms/kg/min [low, medium, and high doses, respectively]) and dobutamine (1, 5, and 10 micrograms/kg/min [low, medium, and high doses, respectively]) were infused. Methoxamine was given in a bolus of 0.22 mg/kg, IV. All measurements were taken at 2.5 minutes after infusion, and were repeated after removal of 40% of the estimated blood volume. Before hemorrhage, administration of high doses of dobutamine and medium and high doses of epinephrine were equally effective at increasing CI and SI. The dP/dT was increased to the greatest degree by administration of high doses of dobutamine. Administration of the low dose of dobutamine increased dP/dT, whereas administration of the low dose of epinephrine increased CI, HR, and SI, and decreased SVR. The HR and SVR were not increased by administration of any dose of dobutamine or of the medium and high doses of epinephrine. However, methoxamine increased SVR and decreased HR. Methoxamine decreased CI, SI, and dP/dT, but increased systemic arterial pressure to the same degree as that attributed to administration of high doses of dobutamine and epinephrine.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
Resistive index (RI) and pulsatility index (PI) are indirect measurements of blood flow resistance that may be measured by pulsed wave Doppler ultrasonography. Chemical restrain may potentially alter the indices although it is required to perform ultrasonography in some patients. The purpose of this study was to describe values for both intrarenal and ocular RI and PI within the same subject in clinically normal dogs sedated with a midazolam and butorphanol combination and evaluate if there are any significant changes between sedated and nonsedated dogs. Fifteen healthy Beagle dogs were studied by Duplex Doppler interrogation in interlobar or arcuate arteries of the kidney and long posterior ciliary artery. Pulse rate and systolic blood pressure were also determined. All measurements were recorded before and after the administration of a sedative combination of midazolam (0.2 mg/kg) and butorphanol (0.2 mg/kg). Mean comparison tests (paired t-tests or Wilcoxon's rank-sum test) were used to determine if any significant differences existed between right and left renal values or right and left ocular values. A correlation study (Pearson or Spearman) was applied between RI, PI, and systolic pressure, and pulse rate. RI and PI were significantly higher in sedated Beagles than in unsedated Beagles. There was neither correlation between index and systolic blood pressure nor pulse rate. In conclusion, provided that normal RI and PI increase in sedated animals, then reference ranges should be higher when sedated--healthy or ill--animals are evaluated.  相似文献   

20.
Nine 7-month-old Beagle dogs were inoculated with 200 third-stage larvae of Dirofilaria immitis. The development of cardiac disease secondary to heartworm infection was confirmed by thoracic radiography, echocardiography, and angiography with blood pressure measurements. The only indication of renal disease was mild-to-moderate proteinuria. The dogs were euthanatized approximately 18 months after inoculation. The mean microfilarial count in blood at the time of euthanasia was 88,700/ml, with a mean of 89 adult heartworms in the vena cavae, heart, and pulmonary arteries. The kidneys were perfused for microangiographic and correlative histologic examination of the intrarenal microvasculature and associated renal morphologic features. Angiograms of whole kidneys from 6 dogs revealed attenuation or truncation of the major renal vessels. Microangiograms of all kidney slices revealed attenuation in the microangiographic appearance of the glomerular capillaries. Histologic examination of all kidney slices revealed mild-to-intense, diffuse, chronic interstitial nephritis and generalized membranoproliferative glomerulonephritis. Microfilariae were observed within the glomerular capillaries and the medullary vessels. The microangiographic changes correlated with and were explained in part by the histologic changes in the renal parenchyma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号