With theoretic analysis, lab experiment and engineering application, it is indicated that the SZJ grounding system is a new type grounding system which distinctly reduces the grounding impedance of grounding grids, especially of grounding grids in the zones with high-resistivity or grounding grids with scanty area. The design and calculation method for application of SZJ grounding system is also studied.  相似文献   

2.
The aufhors calculate and analyze the arcing grounding overvoltage of 10 kV power network in case of neutral ungrounded and grounding through nonlinear resistance using EMTP, with a actual 10 kV power network of a substation in Guizhou province as an example. The emulational calculation results show that the grounding method which grounds through nonlinear resisitance has the advantages of the other two methods, can better limit the arcing grounding overvoltage and can not stop the power supply .even one phase is grounded by fault, so it can ensure the security of the power networkg supply . the network neutral grounding through nonlinear resistance needs more deep study and analysis as a new network neutral grounding mehtod.  相似文献   

3.
A new method is presented to calculate the non-uniform of current distribution on grounding electrode. Based on the equivalence of low frequency current field and static electric field, the electrode is simplified to he a line charge model with limited length. The charge distribution on the model is calculated by solving equilibrant equations, and the current distribution along the axis of electrode was got. The current density at the end of electrode can he several times of that in the middle, the non-uniformity get worse with the increasing of electrode length and numbers. This is what lead to several problems on grounding systems such as inefficiency, the partial overheat and the severe corrosion of electrode.  相似文献   

4.
The number of underdetermined equation, which is limited by the grounding down lines, reduces the grounding grid corrosion diagnostic precision. Based on the grounding grid fault diagnosis method and sensitivity analysis, the value of slip resistance change on the impact of the port resistance in several cases, such as small span, large span and edge, center and symmetrical cross line of the grounding grid, is analyzed. A new method which is used to select the node pairs to calculate the corrosion situation of grounding grid is presented. Based on this method, the simulation analysis and field test has been done. The experimental results show that this method could improve the accuracy and efficiency of grounding grid fault diagnosis.  相似文献   

5.
This paper discuses the method with which the corrosion of the grounding grid can be diagnosed .A grounding grid can handled as a circuit network. With the application of circuit network graph theory and the fault diagnosis theory of analog circuit and optimization, the fault diagnosis equations can be set up. This equations is figured out by Matlab, and the corrosion status of the grounding grid can be deduced from the result.  相似文献   

6.
Grounding grids are the guarantee of substation running safety. The fault of grounding grids is a threat to people and equipment in substations. A method to diagnose the fault of grounding grids based on magnetic field inverse problem. The inverse problem of magnetic field is established by injecting and extracting a low frequency current. The morbid of inverse problem is solved through regularization and Newton iteration method to obtain the distribution of the mesh currents. The approximate distribution of the magnetic field is calculated to diagnose the fault of the grounding grid. A 4×4 substation grounding grids is taken as an example. By comparison of the forward problem result, the error is under 3%, so the prposed method of inverse problem is verified. The selection of measurement point is discussed, and 40% of the number of meshes is accounted to approximate the real distribution of the magnetic field on the grounding grids.  相似文献   

7.
The paper studies the theory about the corrosion as well as the broken point of the grounding grid in power plants and substations. By using sensitivity analysis, failure diagnosis equation is put up through rigorous theoretical analysis. Meanwhile the problem of morbid equation is solved by introducing lowest energy theory and technique of optimiation to diagnosis equation solution of grounding grid combined with definite constraint condition and linear or non-linear objective function, the fault diagnosis equation is discussed. The results of emulation calculation and analogous experiments verify the correctness,feasibility and practicality of the theory and method.  相似文献   

8.
Erosion Optimized Diagnosis of Brand Grounding Grid   总被引:1,自引:0,他引:1  
To find the corrosion of the grid ,large area cutting has been adopting in practice for a very long time. But this method is blind, difficult and influences the system operating. The erosion diagnosis method in the past is effective for the smaller grid. To the brand ones, it can not take effect. The method of separating the grounding grid into several parts and diagnosing step by step is discussed by lots of simulation about middle or brand grounding grid erosion diagnosis. This method makes the brand grounding grid erosion diagnosis quick and truly without power cut and digging large area, satisfies the demand in practice. Putting this optimized diagnosis method into practice , the result is good.  相似文献   

9.
随着智能化GIS设备的发展,GIS设备上集成了大量电子设备。GIS设备开关操作产生的特快速瞬态电磁过程主要经由“传感器—二次电缆—智能组件”这段电路对电子设备产生电磁影响。笔者首先基于传输线网络理论建立了开关操作产生的地电位升对“传感器—二次电缆—智能组件”回路的耦合计算模型,然后通过验证实验证明了计算模型的有效性和准确性,最后对不同屏蔽层接地方式下的各传感器端口和智能组件各端口及端口间的骚扰电压进行了仿真研究。计算结果显示,各骚扰电压受接地方式的影响较大;通过选择合适的接地方式,可以有效地抑制开关操作电磁骚扰。  相似文献   

10.
冯鹤 《中国农学通报》2016,32(17):172-175
为了提高人员生命损失风险计算的针对性、准确性,为人工接地装置安全布设提出建设性的指导意见,通过对人工接地装置泄流时接触电压、跨步电压的计算方法的分析,确定了人工接地体泄流时接触电压、跨步电压导致人身伤亡的损害概率的定量计算方法。计算时,通过对接触电压、跨步电压计算值与人体耐受接触电压、跨步电压阈值的比较分析,确定能达到该阈值的最小雷电流幅值,再通过对项目所在位置雷电活动特征的分析,确定可能超过灾害阈值对应的雷电流幅值,即可能产生风险的雷电流所占的频率,认为该频率即为接触电压、跨步电压导致生物伤害的损害概率。对人工接地装置接触电压、跨步电压的计算以垂直接地极为例,同时考虑了冲击电流较工频电流对计算方法的影响。  相似文献   

11.
The USBCAN bus converter is a connector of USB bus and CAN bus.It is difficult to judge whether the device works well or not and meets design requirement or not by ordinary ways.Regarded the Matlab/Simulink/Stateflow toolbox as the platform,the model of a USBCAN bus converter is established.The model of the bus converter is tested and verified in the Matlab/Simulink simulation environment.The results of the simulation analysis show the model is suitable for simulating the working state of the device.A new simulation and judging method for bus converters is proposed.  相似文献   

12.
家庭阳台水培以观赏性强、整洁方便、绿色安全等特点拥有广阔的市场前景,以家庭阳台水培为设计目的、以用户需求为导向的家庭水培装置能够有效满足当前的市场需求。行为地图法与Kano模型的结合能够准确收集用户需求及重要度,QFD质量屋模型可将产品质量要素按照用户需求重要程度进行排序。据此进行方案优化,指导完成以用户需求为导向的装置设计。装置具有空间集约、造型美观、便于移动及固定、有效减轻水培液浪费污染、电线收纳便捷等优点,更适用于家庭水培。同时,新材料应用等也将成为装置未来提升的方向。  相似文献   

13.
To counteract capacitive current and resume power system, the neutral point of 35 kV power system at the mountainous area is grounding through the arc winding widely. In fact, there is great difficult in selecting the arc winding to satisfy the requirement of system. In a 35 kV power system which neutral point is grounding through the arc winding, the capacitance current are measured in site when a single-phase is grounding. From the measure data, the imbalance of three-phase voltage whether the arc winding exist or not and the operating situation of arc winding are discussed, and bring forward an attentive problem about operation of arc winding and decrease of lightning outage rates.  相似文献   

14.
This paper centers on the study of intelligentized fault lineselection when the small current grounding electric system is grounded in single-phase. Based on the known theories and methods of groundingline-selection, we propose a comprehensive neural-based intelligentized processing plan, which offers a new approach to improving accuracy rate of fault line selection andevaluating various arithmeticfor grounding protection in practice.  相似文献   

15.
A new grating tiling device with 2×2 gratings is developed to obtain a large aperture grating. For the stability of the device impacted by the HVAC vibration, a dynamic finite element analysis model is established. The random vibration response of the model under the measured power spectral density as stimulus has been carried out by the ANSYS software, and the data has been compared to the experimental data. The results show that the device can meet the stability requirements in the work environment.  相似文献   

16.
The unbalanced nature of 35 kV distribution system due to capacity values is difficult in neutral operation, which can not meet the demand of voltage balance in static state and arc distinct in fault. This paper proposes a new neutral operation as neutral insulation in static state and resonance grounding in fault , along with EMTP simulation acts. Simulation indicates that new neutral operation method can improve lightning withstand level and decrease trip-out rate of grids.  相似文献   

17.
Research on Lightning Intruded Wave for 500 kV Substations   总被引:1,自引:0,他引:1  
The study on overvoltage for 500 kV substation caused by lightning intruded wave is presented. In this paper, we calculate by using electromagnetic transient program (EMTP) and combine substation with incoming lines ,so some influence factors can be considered such as impulse voltage second characteristic of insulator strings, lightning stroke point on the incoming lines and impulse grounding resistance of towers. The results show that the method is close to the practice and some factors of incoming lines are important to overvoltage.  相似文献   

18.
The low voltage direct current(LVDC)distribution system has great potential and advantage to be applied to conventional areas, such as residential house, due to its characteristics of energy conservation and being eco-friendly, but there is no existing standard specifications to guide its application in practice to ensure the electrical safety of this system. The protection against electric shock is a key indicator of electric safety, but the effect of electric shocks on AC and DC are different. Refer to the international standard IEC60479-1 and analytical method in AC system, the protection against electric shock between DC 750, 400, 300, 220 V and AC 220 V systems are compared and analyzed based on ideal DC source model. It demonstrates that the negative grounded TT & TN DC distribution system has significant advantages over the traditional AC system, and the safety voltages are given, which could be a reference to develop the normative guidance for the application of LVDC in practical application.  相似文献   

19.
The iterative Lanczos-reduce method for sensitivity analysis, the Guyan condensed method and the iterative synchronous vector methods in finite element modal are studied in order to solve the dynamic characteristic of complicated machine system. The primary reasons influenced on calculation precision are pointed out. The principia of master freedom for Guyan condensed method are put forward. The calculation precision of three methods is compared with the same standard finite element model. The iterative Lanczos-reduce method for sensitivity analysis is proved to be optimum analysis and the eigenvalue of arm in work device of hydraulic excavator in finite element model is solved with iterative Lanczos-reduce method for sensitivity analysis. The theory basis is provided for reasonable choose to solve the dynamic of complicated machine structure.  相似文献   

20.
In this study, we developed an all-around 3D plant modeling system that operates using images and is capable of measuring plants non-destructively without any contact. During the fabrication of this device, we selected a method capable of performing 3D model reconstruction from multiple images. We then developed an improved SfM-MVS (Structure from Motion / Multi-View-Stereo) method that enables 3D reconstruction by simply capturing images with a camera. The resulting image-based method offers a high degree of freedom because the hardware and software can comprise commercially available products, and it permits the use of one or more cameras according to the shape and size of the plant. The advantages of the image-based method are that 3D reconstruction can be conducted at any time as long as the images are already taken, and that the desired locations can be observed, measured, and analyzed from 2D images and a 3D point cloud. The device we developed is capable of 3D measurements and modeling of plants from a few millimeters to 2.4 m of height using this method. This article explains this device, the principles of its composition, and the accuracy of the models obtained from it.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号