首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
Addressing the problem of choosing a fault line under single phase to ground of distribution network, we presented a new criterion based on analysis of the development of fault line selection and a method using wavelet packets. The feature frequency band, or the combined feature frequency bands of each line, in which the transient capacity current was concentrated was chosen for maximum energy. Based on the principle that the transient capacity current's energy of the fault line was larger than the that of normal lines, fault line selection can be carried out adaptively by contrasting the energy of the transient capacity currents of all lines in each chosen frequency band. The simulation results and spot testing data shows the proposed method can detect the fault line in distribution networks precisely and reliably.  相似文献   

2.
The problem of the faulty line selection with the arc suppression coil(ASC) has existed for a long time.On the basis of analyzing the relationships between the ASC admittance and the admittances of lines,including the faulty line and non-faulty lines,the calculation of the b parameter is presented,in which the state of the ASC is changed during the single-ground existing for the faulty line selection by adjusting its inductance.The value of b for the faulty line is much greater than that for non-faulty lines in both the direct ground and the ground with the resistance.The proposed method is verified with the simulation and is applied to the projection.It is proven that the proposed method is with the high reliability.  相似文献   

3.
A novel method for power transmission line monitoring and fault diagnosis is proposed based on non linear frequency response analysis. The power line carrier signal has been used for on line monitoring of power transmission line. As the non linear frequency response function describes the system inherent characterization, different frequency response patterns corresponding to different operation states of transmission line can be established. Based on the analysis of transmission line characteristics of fault modes, various fault features can be extracted, thereby achieve online monitoring and fault diagnosis on transmission line. Simulation experiments show the effectiveness of the proposed method.  相似文献   

4.
The radiation field created by the transmission line stroked by lightning far from the lightning channel has been analyzed by the FDTD method.The authors we establish the calculation model and FDTD calculation method of transmission line,and discusses the import of lightning excitation source.The simulation of lightning stroked on a single transmission line in free space or stroked on three-phase high voltage transmission lines in actual environments has been done,and gives the distribution of transient radiation field around the transmission lines when lightning overvoltage wave transmits along the transmission line.The simulation result shows that: the effect of the transient radiation field caused by lightning over voltage wave done with environment is obvious,and the high frequency component of transient radiation field may disturb or do harm to the electronic facility or communication facility around the transmission lines.  相似文献   

5.
The unbalanced nature of 35 kV distribution system due to capacity values is difficult in neutral operation, which can not meet the demand of voltage balance in static state and arc distinct in fault. This paper proposes a new neutral operation as neutral insulation in static state and resonance grounding in fault , along with EMTP simulation acts. Simulation indicates that new neutral operation method can improve lightning withstand level and decrease trip-out rate of grids.  相似文献   

6.
Helmholtz coils produce uniform sinusoidal magnetic field in the center region, and the direction of magnetic field is approximate straight line, to help simplify the complexity of inverse problems. The simulation models of an 8-channel magnetic induction tomography measurement system are built, reconstructing conductivity distribution with filtered back projection algorithm. In the filtered back projection algorithm, the detected data is supplemented by the linear interpolation first, and then filtered by the Hamming filter, while adding a window filter to reduce the impact of around the coil from the divergence of the magnetic field. The different noise ratio of noise is added in the detected data to test noise suppression ability of the algorithm. The experiment results show that this filtered back projection algorithm can reconstruct the conductivity distribution under this model.  相似文献   

7.
By analyzing shortages of current MSPCA model, an on line multi variable statistical process monitoring method is proposed, which uses some concepts from online multi scale filtering and can be applied to sensor fault diagnosis. In the method, wavelet decomposition is employed to the signals using edge correction filter in a fixed length data window, and then wavelet denoising is conducted with wavelet threshold filtering. Next, an on line multi scale model is constructed for data combining wavelet transformation and adaptive PCA in the previous data window. This model avoids time waste in direct signal denoising and reduces time cost in multi scale data with conventional PCA, which eventually increases accuracy in fault diagnosis. Experiments on eight vibration signals of 6135D diesel engine under severe leak condition prove the practicability and feasibility of the proposed method.  相似文献   

8.
This paper presents a transient mathematical model of the HVDC converters-Equivalent Circuit Method(ECM), which can describe all possible states of converter valves in a simple and explicit way. With the converter model, programs have been implemented for single and double bridge HVDC systems. The results of simulation to the normal and fault operation of HVDC system show that the method is flexible and reliable, and has the advantages of small calculation amount and less computer storage requirments. The programs based on this paper provide convenient, inexpensive and feasible tools for computer dynamic or transient analysis of the HVDC systems.  相似文献   

9.
深部逆断层圆弧形断面诱发煤岩动力灾害的力学分析   总被引:1,自引:0,他引:1  
为了探索逆断层附近易于发生煤岩动力灾害的力学机制,构建了由构造应力为主导的圆弧形断层面简化力学模型,得到了构造应力以及由其引起附加垂直应力的分布规律,进而建立了断层上盘逆冲滑动临界角度的数学模型。研究表明:水平构造应力与附加垂直应力随着断层倾角的增大而增大,当断层倾角接近90°时,附加垂直应力突然增大且其值数倍高于水平构造应力;基于逆断层滑动的力学分析,理论计算了煤层沿断层逆冲滑动的临界角度,这将对煤岩动力灾害的危险性预测有一定的参考意义。  相似文献   

10.
In accordance with the high and extra high voltage long distance transmission line,this paper presents a fault location method based on two terminal information of self synchronous rectification.We adopt the long transmission line model,consider the effect of distribution capacity and can correct the sample phase angle difference in the real time btween two terminals.So that this method can avoid the fault location error owing to asynchronous message on the two terminals.Tested by a lot of simulations,the results are very satisfied.  相似文献   

11.
This paper propsese a new method of getting fault superposed components,with which the high speed ralays can act correctly in the consequent transient process. Digital simul ations have proved the existent problem with the normal method and the correctness of the new proposed method.  相似文献   

12.
The number of underdetermined equation, which is limited by the grounding down lines, reduces the grounding grid corrosion diagnostic precision. Based on the grounding grid fault diagnosis method and sensitivity analysis, the value of slip resistance change on the impact of the port resistance in several cases, such as small span, large span and edge, center and symmetrical cross line of the grounding grid, is analyzed. A new method which is used to select the node pairs to calculate the corrosion situation of grounding grid is presented. Based on this method, the simulation analysis and field test has been done. The experimental results show that this method could improve the accuracy and efficiency of grounding grid fault diagnosis.  相似文献   

13.
为研究Bv-UNG蛋白在植物碱基切除修复(base-excision repair,BER)途径中的功能,以甜菜M14品系为材料,根据NCBI上二倍体栽培甜菜UDG编码基因Bv-UNG序列,利用同源序列克隆法获得甜菜M14品系BvM14-UNG基因cDNA全长,并对其进行生物信息学分析.结果 表明,该基因编码374个氨...  相似文献   

14.
The application of wavelet analysis in fault diagnosis is growing rapidly.There are many different wavelet base to use but no accepted procedure for choosing among them, the analysis results by using them have great difference. This paper describes the significant properties of wavelet base, and analysis behavior of transient signal in wavelet transform, result on some methods for how to choose wavelet base in analysis transient signal.  相似文献   

15.
Grain yields of seven barley cultivars (Hordeum vulgare L.) and 398 doubled-haploid lines derived from their diallel crosses were evaluated in hill plots at two locations in Ontario. Additive × additive epistasis and linkage disequilibrium were detected in the seven cultivars. Additive × additive genetic variance was significantly greater than zero but additive genetic variance was not significantly greater than zero. The narrow-sense heritability on the basis of line means was intermediate (0.33). It was predicted that 13.1% yield improvement could be realized in the next recurrent selection cycle using the doubled-haploid method.  相似文献   

16.
This paper summarizes two kinds of fault detection techniques for distribution automation, that is with and without communication in fault detection, and then analyzes their merits and shortcomings. Moreover, according to the development tendency of distribution automation techniques, this paper presents an approach, through which the noncommunication FTU devices can detect transient fault voltage of distribution systems effectually. To detect transient fault voltage without standby batteries, the PIC Single Chip microcomputer with low power consumption and DSP chip with powerful data processing capabilities are adopted to form a dual CPU system. To realize the communication between the two CPUs, the general I/O port,s of the DSP chip are firstly used to simulate the UART communication of the serial ports and communicate with the PIC Single Chip microcomputer. The novel FTU devices based on this approach are tested in static and dynamic simulation experiments, the results are satisfied.  相似文献   

17.
To solve the problem that the existing method of extracting fault components is easily affected by power system swing,a new methed has been proposed in this paper,which can be used in high speed protection of transmission lines. This proped method ean greatly decrease unbal-ance outputs under power swing condilions without frequency tracking circuits,therefore it can make the protection using fault compnents operate correctly.  相似文献   

18.
构建高羊茅光周期调控基因FaCONSTANS与绿色荧光蛋白基因GFP融合的植物表达载体P-FaCONSTA NS-hGFP,基因枪转化法转入洋葱表皮细胞,荧光显微镜检测融合基因的瞬时表达.并运用实时荧光定量PCR研究光周期调控基因FaCONSTANS在长日照与短日照条件下昼夜24 h的表达差异.结果表明:FaCONST...  相似文献   

19.
Transient analysis of transmission line has recently been received more attention because operating speeds in high-speed digital electronics are increasing. Transmission line equations are hyperbolic partial differential equations, firstly this paper deduces how to change transmission line equations into quasilinear differential equations , thus the transmission line equation numerical result is gotten by computing the differential formation of quasilinear differential equations. The constraint of voltage and current is be considered and lumped equivalent circuit mode at boundary network collaborated at the same time in finding boundary conditions. Finally the paper computes transient response of transmission line with two typical boundary conditions. Numerical result shows that this approach is an effective way. It is explicit algorithm with less CPU consumption which can get time field response directly. The agree-upon effective way does be frequency field method, however it could not get time response unless the numerical inverse laplace transformation (NILT) be introduced. Thus this approach is more effective than FFT algorithm.  相似文献   

20.
Building management control systems (BMCS) are widely employed in modern buildings. The huge amount of data available on central stations and outstations provide rich information for fault diagnosis of HVAC systems. An online fault diagnosis method for variable air volume air handling units was presented using self-tuning HVAC component models. The model parameters are tuned online by using a genetic algorithm (GA) which minimizes the error between measured and estimated performance data, so high modeling accuracy is assured. If the error between measured and estimated performance data exceeds preset thresholds, it means the occurrence of faults or abnormalities in the air handling unit system. The statistical method of selecting thresholds also is presented. The fault detection method was tested and validated using data collected from real HVAC systems. The results of validation show that the fault detection method can be integrated in BMCS systems to detect faults in air handling unit systems efficiently.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号