首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Measurement of glomerular filtration rate (GFR) via gamma camera uptake of 99mTc‐diethylenetriaminepentaacetic acid is a standard method for quantifying renal function. Aims of this retrospective, observer agreement study were to determine intra‐ and interobserver variation in GFR values for cats with chronic kidney disease and to determine whether renal insufficiency classification changed between observers. Guideline cut‐points were established for the difference in repeated GFRs to differentiate changes caused by therapeutic effect vs. inherent variation. Included cats had a diagnosis of chronic kidney disease and had undergone GFR examinations between the years of 2010 and 2013. Twenty‐nine GFR studies were sampled. Each study was read twice, 6 months apart, by two veterinary radiologists and one radiology resident. Modified Bland–Altman plots were used to investigate differences between readings 1 and 2 by observer and between pairs of observers by reading. Reliability of clinical classification was assessed through comparisons between readings and observers. Measurements were not systematically different between readings for the experienced observers but were higher in reading 1 than reading 2 for the inexperienced observer. Measurements were not systematically different between the experienced observers in reading 1 or between any two observers in reading 2. Reliability for GFR measurements was high among experienced observers; variations in GFR measurements rarely led to differences in clinical classification. Results suggested that, for experienced observers, changes in GFR values following treatment in cats with chronic kidney disease between ?0.4 and 0.4 mL/min/kg may be due to inherent variability rather than treatment effect.  相似文献   

2.
Measurement of the tibial plateau slope from lateral hind-limb radiographs is a preoperative requirement when performing tibial plateau leveling osteotomy (TPLO) for repair of the cruciate-deficient stifle in dogs. Two measurements of the tibial plateau slope in 312 stifles of 156 dogs were taken from lateral radiographs by each of three observers with varying degrees of experience in the measurement method. Intraobserver variability was +/-3.4 degrees, and interobserver variability was +/-4.8 degrees. No significant differences were identified for the intraobserver measurements; however, in evaluating interobserver variability, a significant difference was found between the inexperienced observer and the two experienced observers.  相似文献   

3.
OBJECTIVES: To determine the agreement between observers and to investigate the effect of observer experience in diagnosing canine hip dysplasia and providing final scoring of hips using the standard ventrodorsal hip-extended radiographic method. The agreement of the final scoring, with a presumed correct assessment based on the Norberg angle, is also investigated. METHODS: Thirty observers were requested to read 50 ventrodorsal hip-extended radiographs of 25 dogs according to Federation Cynologique International criteria. Groups of experienced (nine members) and inexperienced (21 members) observers were used. RESULTS: For providing the distinction between dysplastic versus non-dysplastic dogs, the average interobserver agreement was 72 per cent and was significantly higher (P<0.0001) than the score that could be expected by chance without any agreement between observers. For providing the final score (A, B, C, D or E), an average interobserver agreement of 43.6 per cent was found. In the experienced group, an agreement score of 76 per cent was found for the distinction between AB versus non-AB and an agreement score of 81 per cent was found for the distinction between C versus non-C. The agreement score was significantly higher (P<0.0001) for the experienced group than for the inexperienced group in all cases. Agreement between the presumed correct assessment based on the Norberg angle and the observer's evaluation was low (P=0.35), irrespective of whether the observers were experienced (71.8 per cent correct assessments) or inexperienced (69 per cent correct assessments). CLINICAL SIGNIFICANCE: Although interobserver agreement is low, observer experience increases agreement.  相似文献   

4.
Background – Cutaneous cytology is used in veterinary dermatology to assess bacteria and yeast on the skin surface and in the ears for diagnostic purposes and to monitor treatment success. A number of methods were used in reported studies to quantify micro‐organisms on cytology, but evaluation of the intra‐ and interobserver reliability of the methods is rare. Objective – The aim of this study was to evaluate the intra‐ and interobserver reliability of a semiquantitative cytology assessment method frequently used in practice. Methods – A total of 60 experienced and inexperienced veterinarians and veterinary students were asked to evaluate 10 glass slides and 18 photographs of cutaneous cytology twice. Cocci, rods, yeast, neutrophilic and eosinophilic granulocytes and macrophages were graded from 0 to 4+. Results – The intra‐observer reproducibility for evaluating the slides in the experienced group was 84.3%; in the inexperienced group it was 82.6%. For the photographs, the intra‐observer reproducibility was 92.1% in both groups. The interobserver reproducibility for evaluating the slides was 81.6 and 81.0% in the experienced and inexperienced group, respectively; corresponding values for the photographs were 91.0 and 90.0%. There was no significant difference between different participants or between the first and second evaluation by each participant for any of the parameters graded. Conclusion and clinical importance – Based on these results, this semiquantitative method of grading can be recommended for evaluating and monitoring of antimicrobial therapy in daily practice.  相似文献   

5.
The aim of the present study was to establish which adrenal gland measurement was characterized by the least variations. To do this, we quantified the variability of seven different size measurements of the canine adrenal gland (maximal length, maximal height at the cranial and caudal poles on longitudinal and transverse images, and maximal width of the cranial and caudal poles) within observer, between observer, and between dogs based on three different measurements made by each of the three observers in six healthy Beagle dogs. The height of the caudal pole of both adrenal glands measured on longitudinal images had the lowest intra‐ and interobserver variability, while measurements of the length had the highest intra‐ and interobserver variability. Other measurements that were characterized by low intra‐ and interobserver variability were: height and width of the caudal pole on transverse images and height of the cranial pole on longitudinal images only. These results provide a basis for further study of the changes in adrenal gland size in dogs with pituitary‐dependent hyperadrenocorticism.  相似文献   

6.
Joint effusion is one of the classic radiographic signs of osteoarthritis, but no information is available regarding clinicians' ability to detect joint effusion radiographically. This study determined the accuracy and precision of experienced and inexperienced observers in detecting joint effusion of the distal interphalangeal (DIP), metacarpophalangeal (MCP) and midcarpal joints on radiographs. Fresh cadaverous forelimbs were loaded in a material testing machine to mimic a standing horse. The joints were gradually distended and lateromedial and dorsopalmar radiographs were acquired. The images were assessed by three experienced and three inexperienced observers. This study showed that the sensitivity was high for both groups for all joints and projections. Specificity was high for the experienced group but low for the inexperienced group. There was a significant positive correlation between joint distension and severity of joint effusion when reported by experienced observersfor most views (except DIP joint), but only for the MCP joint for inexperienced observers. Interoperator agreement was poor to fair for the experienced group and poor for the inexperienced group. In conclusion, the accuracy and precision of grading joint effusion on radiographs was highly subjective and related to experience.  相似文献   

7.
Adrenal length and width were determined from two-dimensional ultrasound longitudinal images. In study 1, 540 measurements of adrenal glands were attempted from five healthy beagle dogs by three different observers with different levels of expertise in ultrasonography, to determine the variability of adrenal gland measurements. Of these, 484 measurements were included in the statistical analysis, since 16 measurements of the left adrenal gland and 40 for the right could not be visualised by the observer. In study 2, a single measurement of both adrenal glands was taken from each of 146 dogs by the most trained observer from study 1, and the effects of different health status (healthy dogs v dogs with non-adrenal diseases), bodyweight, age and sex were assessed. A total of 267 measurements were included in the statistical analysis. The lowest intra- and inter-day coefficient of variation values were observed for the left adrenal gland and by the most trained observer. The health status had no statistically significant effect on adrenal gland length or width, whereas age had a significant effect only for the left adrenal gland (the greater the age, the greater the width or length) and sex had a significant effect only for the right adrenal gland (the width was larger in males and the length larger in females). The bodyweight had a significant effect for the length of both adrenal glands (the greater the bodyweight, the greater the length), but not the width. The differences between sd and coefficient of variation values for the width of the left adrenal gland were not statistically significant between the three observers, whereas they were statistically significant for the right adrenal gland.  相似文献   

8.
OBJECTIVE: To evaluate the usefulness of high-resolution ultrasonography (HRUS) for measurements of anterior segment structures in canine eyes. ANIMALS: 4 clinically normal Beagles. PROCEDURE: Images were obtained from 8 eyes with a handheld 20-MHz transducer. Eleven anterior segment structures on each image were measured 5 times by 2 independent observers. Coefficients of variation (CVs) for measurements were used to assess intraobserver reliability. Interobserver reliability was assessed by comparing measurements obtained by the 2 observers from the same images. Five images were sequentially obtained from 2 locations (ie, superior and temporal) to evaluate image reproducibility. Anterior segment structures were measured once on each image; image reproducibility was assessed by use of the CV for each parameter measured. Imaging location was assessed by comparison of CV for measurements from each location. RESULTS: CVs were < 10% for observer A for all measurements except the ciliary cleft area (11.63%). The CVs were > 10% for observer B for measurements of the angle recess area (18.51%) and ciliary cleft width (17.44%) and area (16.01%). Significant differences in measurements between observers were found for 5 of 11 anterior segment structures. Imaging the superior aspect of the globe provided the most reproducible images, although image reproducibility was still somewhat variable, with the highest and lowest CVs for measurements of 33.01% and 11.32%, respectively, in the superior position. CONCLUSIONS AND CLINICAL RELEVANCE: High-resolution ultrasound images can be used to reliably measure various anterior segment structures. Clinically relevant findings in the anterior segment of canine eyes may be detectable by use of HRUS.  相似文献   

9.
The accuracy of the Rice pelvimeter for measuring pelvic area of double muscled Belgian Blue (BB) cattle was investigated by comparing measurements in the live animal with these obtained from the same animal after slaughter. Pelvic measurements from 466 BB-cows aged 2–10 years old and of an excellent carcass qualification (S and E in the SEUROP classification) were measured with the pelvimeter approximately 12 h prior to, and by graded ruler within 2 h after, slaughter. The mean difference of measurements between living and dead cattle were − 0.2 cm for pelvic width (95% limits of agreement − 2.5–2.1 cm), and 1.2 cm for pelvic height (95% limits of agreement − 1.8–4.1 cm). The correlation coefficient between all pelvic measurements was between 0.46 and 0.59 (p < 0.001). The age of the animals influenced only pelvic height whilst carcass weight influenced all the components of the pelvic area. There was a significant correlation between the pelvimetric measurements of the birth canal in living cattle obtained using a Rice pelvimeter compared to actual measurements obtained from the carcass. The Rice pelvimeter is a suitable tool for assessing accurate pelvic skeletal conformation and to select animals in this breed with a larger birth canal and hence less dystocia problems.  相似文献   

10.
Instantaneous intake is central to the understanding of large herbivore foraging strategies and rangeland ecology. Unfortunately, its measurement under field conditions remains challenging because of the difficulty of estimating bite mass. The hand plucking method provides a simple, noninvasive method of estimating bite masses and thus instantaneous intake of grazing herbivores. However, many authors questioned its accuracy and interobserver repeatability. In this study, we tested the accuracy and the repeatability of the hand plucking method using four observers and two herbivore species (i.e., cattle and goats). We compared hand plucked bite mass estimates to actual bite mass of bites taken by the herbivores on natural patches of grass. Training of the observers was fundamental to obtaining accurate bite mass measurements. The mean daily accuracy of the observers’ bite mass estimates increased from 60–80% to 80–94% within 5 d. After training, the relationship between bite mass estimates and actual bite mass was linear and not significantly different from a Y = X relationship. This means that individual bite mass estimates were centered on the real values and thus positive and negative errors canceled each other when combined. As a result, estimates of cumulative intake over about 10 feeding stations had accuracies of over 95%. Furthermore, neither the observer identity nor the herbivore species affected the accuracy of the measurements. The categorization of bites into different size categories proved to be essential in achieving accurate measurements. When observers are trained, hand plucking is a reliable and accurate method of estimating bites mass and instantaneous intake of grazing herbivores. This has important implications for rangeland research and management, as hand plucking is often the only practicable method available for estimating instantaneous intake of free-ranging herbivores.  相似文献   

11.
The repeatability of ultrasonographic measurements of the canine thyroid gland was evaluated. The variability of three different parameters (the maximal length, width, and height) within observer, between observer and between dogs was assessed based on three different measurements made by each of three observers infive healthy beagle dogs. From the three parameters, the volume of the gland was estimated using a formula of a rotation ellipse. The height and the volume had the lowest intra- and interobserver variability, while measurements of the length had the biggest intra- and interobserver variability. The mean values, with their 90% confidence interval were: height = 0.53cm [0.33-0.73], length = 2.45cm [2.04-2.85], width = 0.62cm [0.46- 0.78], volume = 0.38 cm3 [0.20-0.55].  相似文献   

12.
OBJECTIVE: To determine the reproducibility and accuracy of computed tomographic (CT) measurements of pituitary gland dimensions in healthy dogs. ANIMALS: 35 healthy sexually intact adult dogs. PROCEDURES: 2 observers independently viewed CT images of the skull in 35 dogs twice. Pituitary gland height, width, length, and volume and pituitary gland height-to-brain area ratio (P:B ratio) were measured or calculated. Intraobserver and interobserver agreement indexes (AIs) were calculated for pituitary gland dimensions. Computed tomography was performed also on 5 phantoms, and both observers measured phantom dimensions twice. True-value AIs were calculated for the phantom study. RESULTS: The mean +/- SD interobserver AI between observer 1 and 2 for pituitary gland height and the P:B ratio was 0.90 +/- 0.07. The intraobserver AI for pituitary gland height and the P:B ratio was 0.97 +/- 0.04 for observer 1 and 0.94 +/- 0.04 for observer 2. The intra and interobserver AIs for the other dimensions were lower than those for pituitary gland height and the P:B ratio. All phantom dimensions on CT images were underestimated significantly, compared with their true values. CONCLUSIONS AND CLINICAL RELEVANCE: The intra- and interobserver AIs for pituitary gland dimension measurements on CT images were high. However, the same observer preferably should perform serial measurements. Window settings influence pituitary gland dimension measurements, and predetermined window settings are recommended to make comparisons among dogs. Pituitary gland dimension measurements made from CT images in our study underestimated the true values.  相似文献   

13.
Some anatomical characteristics of 507 Belgian Blue (BB) cattle, withers height (WH), heart girth (HG), the distance between the two tubera coxae (TcTc) and the distance between the two tubera ischiadica (TiTi), were compared with the internal pelvic measurements of width, height and area. Mean values were 58.9 ± 6.2 cm for TcTc, 14.6 ± 2.3 cm for TiTi, 15.2 ± 2.1 cm for pelvic width (PW), 18.8 ± 1.9 cm for pelvic height (PH) and 288.5 ± 60.9 cm(2) for pelvic area (PA). Cows that calved per vaginam had larger WH (p < 0.05), TcTc (p < 0.05) and TiTi (p < 0.001) and internal pelvic measurements [PH and PA (p < 0.001)] compared with those whose parturition was managed by caesarean section (CS): Correlations between internal pelvic measurements and TcTc were higher (r = 0.58-0.63) than TiTi (r = 0.22-0.28). Correlations between other external body measures such as HG and WH with the internal pelvic measurements were even higher for HG (r = 0.69-0.74) and for WH (r = 0.67-0.74). HG and WH, together with internal pelvic measures, may be added to estimated breeding values (EBV's) that should assist breeders in selecting cows that can calve per vaginam, thereby reducing the breed's dependence on elective CS for maintaining its unique characteristics.  相似文献   

14.
Insufficient agreement on scoring hip quality might be caused by differences in the assessability of a radiograph (exposure, contrast, positioning, and diagnostic quality). We studied the agreement in assessability of standard ventrodorsal hip-extended radiographs by experienced (nine) and inexperienced (21) observers, using the standard subjective method of quality control, currently applied in screening programs. The effect of assessability on the agreement of scoring hip quality [dysplastic vs. nondysplastic and the final Federation Cinologique International (FCI) score] was also investigated. There was a significant difference ( P <0.0001) in agreement on assessability between the experienced and inexperienced observers. In 68% of evaluations, experienced observers stated that the radiograph was assessable. Inexperienced observers evaluated the radiographs as being assessable in only 46.5% of evaluations. Increased interobserver agreement on assessability of a radiograph did not increase the overall interobserver agreement in the diagnosis of hip dysplasia, nor did it result in consistent scoring of the hip status from that radiograph, despite a significant ( P <0.05) increase in agreement of FCI scoring with an increasing agreement on assessability at a one to five ratio in the experienced group. The inconsistent evaluation of radiographic quality, as well as the inconsistent evaluation of the hip quality, caused differences in diagnosing hip dysplasia and FCI scoring in the same dog ranging from excellent hips to moderate hip dysplasia. Therefore, the credibility of the FCI screening method for canine hip dysplasia, using the standard hip-extended radiographic view, as currently applied in most European countries, is questionable.  相似文献   

15.
The behaviour of sheep, goats and cattle on a shrub and tree savannah in the sub-humid zone of West Africa was studied during the dry (February to May), rainy (June to September) and cool season (October to January). Two mature females per animal species were followed by two observers during 3 days per month and behaviour activities were recorded every 15 min of the daily grazing time. When browsing, the plant name, plant part and plant height reached during prehension were recorded. The distance travelled and the grazing circuits were recorded with a step counter and a Geographic Position System device. The knowledge of farmers concerning appreciated browse species relative to the browse species consumed by animals in the area was also investigated.

During the dry season sheep, goats and cattle spent around 25% of their time browsing and 20%, 16% and 31%, respectively, of their time grazing. During the cool season, goats (17%) browsed more than sheep (7%) and cattle (5%) (P < 0.05). During the rainy season, sheep browsed 20% of the time while cattle spent only 7% of their time browsing, while goats were tied, with no opportunity for browsing. Browsing leaves was the most important part of the browsing activity. During the cool season, browsing height was the same (1.0 m) for cattle and goats, but lower for sheep (0.6 m) (P < 0.05). In the dry and cool season, sheep and goats walked shorter distances than cattle.

The plant species with the highest frequency of consumption were Acacia dudgeoni Craib, Ficus gnaphalocarpa (Miq.) A. Rich, Dioscorea togoensis Knuth, Cordia myxa L., and Manguifera indica L. for sheep and goats and Afzelia africana Sm., Kaya senegalensis (Desv.) A. Juss, Pterocarpus erinaceus Poir. and Dicrostachys cinerea (L.) Wight and Arn. for cattle. Species with a high frequency of citation by farmers were A. africana (92%), K. senegalensis (88%), P. erinaceus (86%), Faidherbia albida A. Chevalier (80%), A. dudgeoni (70%) and F. gnaphalocarpa (69%).

In conclusion, browse species make an important contribution to the diet of ruminant animals in the sub-humid zone and farmers are familiar with the species consumed by ruminant animals.  相似文献   


16.
Measurement of heart-girth (chest circumference) is commonly used to estimate dairy heifer body weight from previously derived equations or tables. In this experiment, variability of heart-girth measurements as they are taken in the field was analyzed to determine the standard deviation within a group of 26 Holstein heifers of various ages weighing 42–590 kg. Standard deviations were 2.19 cm among 26 observers and 2.74 cm within any one observer. Repeatability between two heart-girth measurements by an individual observer on the same animal using a blind heart-girth tape was >0.99. Correlation coefficients between two measurements by different observers using blind measuring tapes on the same animal also were >0.99, with 99% of total differences due to observer and heifer, indicating very little random variation. A second part of this study was the validation of the most recently derived equation to calculate body weight from heart-girth. The equation was validated with data sets from universities across the United States and field data collected specifically for this study. Experimental and field data comprised of heart-girth and body weight measurements upheld the previously derived equation and support its continued use. These results allow more precise interpretation of heart-girth data collected from field studies with Holstein dairy heifers and provide more complete validation of existing body weight-prediction equations.  相似文献   

17.
OBJECTIVE: To assess the accuracy and reliability of a visual method of evaluating horseshoe characteristics. ANIMALS: 1,199 Thoroughbred racehorses. PROCEDURE: Characteristics of 1 forelimb horseshoe were visually assessed on horses immediately prior to racing by 5 field observers at 5 major racetracks in California. Characteristics evaluated included horseshoe type; toe grab height; and the presence of a rim, pad, and heel traction devices. Sensitivity and specificity for observer assessment of horseshoe characteristics were calculated by comparing observer assessments to a postmortem laboratory standard for horses that died within 48 hours of a race. Intraobserver agreement was assessed in a subset of horses by comparing horseshoe observations made before and after the horse's race. Interobserver agreement was evaluated by comparing horseshoe assessment among observers who examined the same subset of horses prior to racing on select days. RESULTS: The sensitivity and specificity of this visual method of evaluating horseshoe characteristics were good and ranged from 0.75 to 1 and 0.67 to 1, respectively. Agreement beyond chance (weighted kappa values) between observers and the laboratory standard for toe grab height was fair (0.60 to 0.62). Intraobserver and interobserver agreements (kappa values) were high (0.86 to 0.99 and 0.71 to 1, respectively). CONCLUSIONS AND CLINICAL RELEVANCE: Visual observation of horseshoes can be a feasible and reproducible method for assessing horseshoe characteristics prospectively in a large cohort of horses under racing conditions.  相似文献   

18.
Reproductive efficiency is of economic importance in commercial beef cattle production, since failure to achieve pregnancy reduces the number of calves marketed. Identification of genetic markers with predictive merit for reproductive success would facilitate early selection of females and avoid inefficiencies associated with sub-fertile cows. To identify regions of the genome harboring variation affecting reproductive success, we applied a genome-wide association approach based on the >700,000 SNP marker assay. To include the largest number of individuals possible under the available budget, cows from several populations were assigned to extremes for reproductive efficiency, and DNA was pooled within population and phenotype before genotyping. Surprisingly, pools prepared from DNA of low reproductive cattle returned fluorescence intensity data intermediate between fertile females and males for SNP mapped to the Y chromosome (i.e., male sex chromosome). The presence of Y-associated material in low reproductive heifers or cows was confirmed by Y-directed PCR, which revealed that 21 to 29% of females in the low reproductive category were positive by a Y chromosome PCR test normally used to sex embryos. The presence of the Y chromosome anomaly was further confirmed with application of additional Y-specific PCR amplicons, indicating the likelihood of the presence of some portion of male sex chromosome in female cattle in various beef cattle herds across the U.S. Discovery of this Y anomaly in low reproductive females may make an important contribution to management of reproductive failures in beef cattle operations.  相似文献   

19.
OBJECTIVE: To assess intra- and interobserver repeatability of ocular biometric measurements obtained by means of high-resolution B-mode ultrasonography in dogs. Animals-6 Beagles without ocular abnormalities. PROCEDURES: B-mode ultrasonography was performed bilaterally with a 10.5-MHz broadband compact linear array transducer. All measurements were made on 2 different occasions by 2 observers. The Bland-Altman method was used to assess agreement between measurements obtained by the 2 observers and between the 2 sets of measurements obtained by each observer. RESULTS: Intra- and interobserver repeatability was highest for larger measurements, such as depth of the eye and depth of the anterior chamber. When repeatability was examined, bias was significantly different from 0 for only a few measurements, but the percentage difference between observations was as high as 180% for some measurements. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that most measurements of intraocular distances and structures obtained by means of high-resolution B-mode ultrasonography have acceptable intra- and interobserver repeatability. However, the percentage difference between observations can be high for smaller measurements.  相似文献   

20.
Sleep is one of the essential behaviors for mammals. The aims of this study were to validate the use of accelerometer for measuring sleeping posture of cattle. Duration of sleeping posture of seven Japanese Black cows from 19.00 to 07.00 hours was measured by both accelerometer and video, and a total of 67 accelerometer and video measurement sets were collected. We calculated Cohen's κ coefficient between accelerometer and video measurements and 91.5% of the κ‐values were >0.80. Intra‐ and inter‐observer coefficient of variance showed that specific acceleration waveform patterns of sleeping posture could be easily and accurately detected by independent observers. There were no significant differences in the frequency of sleeping posture occurrences between accelerometer and video measurements. We compared averaged sleeping posture bout, and the total sleeping posture time between accelerometer and video measurements using regression. In each trait, the slope was close to 1 and the intercept was not different from 0, which showed a strong agreement between accelerometer and video measurements. This shows that an accelerometer could accurately detect sleeping postures of cattle. We conclude that adequate measurements of sleeping postures can be made using an accelerometer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号