首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 781 毫秒
1.
Objective: To determine (1) the minimum number of throws to form secure Aberdeen (AB) and square knots to start (SS) and end (SE) continuous patterns, in fat‐ and plasma‐coated polydioxanone; and (2) compare relative knot security (RKS) and knot volumes of these secure SS, SE, and AB knots. Study Design: In vitro experimental materials testing. Sample Population: Polydioxanone suture material (3 metric). Methods: Each knot was tested 20 times, and throws incrementally added until secure SS, SE, and AB knots were found. RKS and knot volumes were calculated for SS, SE, and AB knots. Results: Secure SE knots needed 5 throws in plasma or fat. Secure SS knots needed 4 throws in plasma, but 5 in fat. The minimum AB configuration that was secure in plasma or fat was 3+1, however, the 4+1 AB knot was also secure in fat. Mean (SD) RKS of secure knots were: SE 59.69% (5.91), SS 67.92% (12.50), AB 81.08% (8.99). AB knots had significantly higher mean RKS than any SS or SE knot in plasma or fat (P<.001). Mean knot volume of 3+1 AB knot was significantly smaller than any secure SS or SE knots by 22.6–69.4% (P<.0001). Mean knot volume of 4+1 AB knots was significantly smaller than all fat secure SS and SE knots by 19.9–57.5% (P=.0001). Conclusion: The knot security of the SS knot was decreased by fat coating polydioxanone suture, requiring an additional throw to keep it secure. Secure AB knots had a higher breaking strength and smaller knot volume than secure SS and SE knots. Clinical Relevance: The AB may be preferable to square knots in continuous closures. As many body fluids contain lipid, surgeons should tie knot configurations considered secure in fat. We advise tying a 4+1 AB and placing a minimum of 5 throws to tie SS and SE knots using 3 metric polydioxanone.  相似文献   

2.
The knot security of chromic gut, polyglycolic acid, polyglactin 910, polydioxanone, polypropylene, and monofilament nylon size 2-0 suture materials were tested biomechanically in vitro. Twenty reproducible knots were tied and incubated in canine serum at 37 degrees for 24 hours before testing. A "secure knot" was defined as a knot that, when tested to failure, broke rather than untied by slippage. The minimum number of throws necessary to make a secure, snug (1500 g tension) square knot was three for gut, polyglycolic acid, polyglactin 910, and polypropylene and four for polydioxanone and nylon. All throws including the first were counted. With all suture materials tested, surgeon's knots were as secure as square knots. Only gut, polyglycolic acid, and polydioxanone granny knots were as secure as square knots; no loosely tied (500 g tension) asymmetric square knots were as secure as snug square knots, and only polydioxanone and polypropylene loose square knots were as secure as snug square knots. Square knots used to start a continuous pattern required one additional throw with gut, polydioxanone, and nylon. Square knots used to end a continuous pattern required two to three additional throws with all materials tested.  相似文献   

3.
OBJECTIVE: To determine a hand-tied ligature knot configuration, suture size, and suture type that would be an acceptable substitute to commercially available ligature knots for use in equine laparoscopic surgery. STUDY DESIGN: Three-factor ANOVA with the fixed effects being suture type, suture size, and knot type. The dependent variable was ligature security (load to failure). METHODS: Commercially available Endoloop and 4 hand-tied slipknot ligatures were compared with a 4-layer square knot. The hand tied ligature knots tested were the 4S modified Roeder knot, the Brooks knot, the modified Roeder knot, and the Weston knot. Two suture sizes (0, 2) of each of 2 suture types (polydioxanone, polyglactin 910) were tested with each hand tied knot. Two types (polydioxanone, polyglactin 910) of size 0 Endoloop were tested. Twenty repetitions of each knot suture type were tested for force to yield on a materials testing machine. Statistical analysis consisted of a 3-way ANOVA with individual comparisons made using the Bonferroni method. Significance was P< or = .05. RESULTS: Only the 4S modified Roeder knot in 2 polydioxanone (103 N) was comparable with the breaking strength of the square knots (157 N). All other knot suture combinations tested were significantly weaker than the square knot (range, 2-18 N). CONCLUSION: For equine laparoscopy, a 2 polydioxanone 4S modified Roeder knot would be an acceptable alternative to the commercially available Endoloop. CLINICAL RELEVANCE: Laparoscopic slip knots are commonly used in equine laparoscopic surgery. Various knot configuration and suture size and type combinations will affect the security of the slip knot.  相似文献   

4.
Objective —To test a crimp clamp system designed to secure monofilament nylon leader (MNL) material commonly used as lateral fabellotibial sutures (LFS) in extra-articular stabilization of the canine stifle joint.
Study Design — In vitro biomechanical tests of MNL loops secured with either the crimp clamp system or knots were performed. Suture loops (n = 94) were created from 27.3 kg tensile strength MNL and fastened with knots or crimp clamps. Tests were conducted on steam-sterilized, ethylene-oxide-sterilized, and nonsterilized MNL sutures. Loops were evaluated in single load tests and cycled tests. Values for load to failure, initial loop tension, loop elongation, mode of failure, and point of failure were determined.
Results —Crimp-clamped loops were superior to knotted loops in all parameters tested in both cycled and noncycled tests. Loop failure generally occurred by breaking within 3 mm of the fixation in both clamped and knotted tests. Loop elongation after cycling was greater in the knotted loops compared with clamped loops ( P < .001). Load to failure was greater in clamped tests than in knotted tests (P < .001), regardless of sterilization technique used. Significantly higher initial loop tension could be achieved with the clamp system compared with knot fixation ( P < .001).
Conclusions —The crimp clamp system provides superior in vitro loop fixation characteristics compared with knot fixation in 27.3 kg test MNL.
Clinical Relevance —Based on the results of biomechanical testing and the known biocompatibility of the system's implant components, clinical trials using the crimp clamp system are warranted.  相似文献   

5.
OBJECTIVE: To compare the peak force required for failure of hand-tied laparoscopic slipknot ligatures. STUDY DESIGN: In vitro mechanical evaluation of suture material/knot combinations. Sample POPULATION: Four hand-tied laparoscopic slipknots were studied. Three suture materials and 2 suture sizes were evaluated. Twenty samples of each group were tested, for a total of 400 samples. METHODS: The 4S modified Roeder, modified Roeder, and Weston and Brooks laparoscopic slipknots using 0 polyglyconate, 0 polyglycolic acid, 1 polyglyconate, and 1 polydioxanone (PDS) were tested. A vertical distracting force (5 mm/s) was applied until failure. Mean peak force to failure was obtained for each suture material, size, and knot combination. RESULTS: Mean (+/-SEM) peak force to failure of hand-tied ligatures ranged from 156.8+/-9.1 N to 4.8+/-.4 N. The 4S-modified Roeder had the highest mean peak force to failure. Ligatures tied with polyglyconate and size 1 suture had the highest mean peak force to failure. CONCLUSIONS: The 4S-modified Roeder was significantly and consistently stronger than the other slipknots. Polyglyconate was superior to other suture materials. The 1 polyglyconate had the highest mean peak force to failure followed by 0 polyglyconate that exceeded the 1PDS. CLINICAL RELEVANCE: The 4S-modified Roeder slipknot using 1 polyglyconate has the greatest breaking strength of sutures tested and should be considered when performing laparoscopic ligatures.  相似文献   

6.
Objective— To evaluate the effect of 6 different knotting methods on the mechanical properties of 3 large absorbable suture materials used in large animal surgery. Study Design— In vitro mechanical study. Sample Population— Knotted suture loops (n=15 per group). Methods— Suture loops were created between two low‐friction pulleys with either 2 polydioxanone, 2 polyglactin 910 or 3 polyglactin 910. Strands were tied using 1 of 6 knotting technique: square knot, surgeon knot, clamped surgeon's knot, sliding half‐hitch knot (HH), Delimar knot and self‐locking knot (SLK). A single cycle to failure test was performed on each suture loop with a distraction rate of 100 mm/min. Failure modes were evaluated and breaking strength, elongation to failure and stiffness were compared. Results— All loops except two HH failed at the knot by acute breaking. The double‐stranded SLK was both stronger and stiffer than all other knots for each suture material. Clamping the first throw of the surgeon knot decreased load to failure significantly (143.11 ± 8.64 N) compared with not clamping (159.21 ± 6.14 N) for polydioxanone. Stiffness and elongation to failure were respectively lower and increased for 2 polydioxanone compared with both polyglactin 910 materials for all knotting techniques. Conclusions— Knotting techniques do influence structural properties of suture loops. The double strand loop conferred stiffer and stronger properties to the SLK Clinical Relevance— Clamping the first throw of polydioxanone should be avoided when tying a suture under tension even using large diameter suture materials. Using a SLK might be considered as a useful alternative when excessive tension is present.  相似文献   

7.
Objective— To compare Chinese finger trap (CFT) and 4 friction suture (FFS) techniques to secure gastrostomy (GT), jejunostomy (JT), and thoracostomy (TT) tubes of different materials.
Study Design— Prospective experimental study.
Animals— Canine cadavers (n=20).
Methods— Randomly, GT (n=20), JT (20), and TT (20) were inserted using 2 different suture techniques (10 for each tube type) and either silicone or another material (10 for each type). Axial distraction was applied to each tube until failure. Force and displacement to failure and failure mode were recorded and compared between techniques and materials for GT, JT, and TT.
Results— CFT failed most commonly by suture breakage whereas FFS failed mainly by tube slippage ( P =.003). For GT, failure occurred more commonly by tube slippage (n=15; P <.001) whereas tube breakage was more common for JT (n=10; P <.001) and suture breakage for TT (n=14; P =.022). Silicone had higher force to failure than latex with GT, lower force to failure than red rubber with JT, and lower displacement to failure than polyvinylchloride with TT.
Conclusions— Different failure modes occurred for CFT (suture breakage) and FFS (tube slippage) and among different tube types (tube slippage with GT, tube breakage with JT, and suture breakage with TT). Based on study results, CFT is preferred to FFS for anchoring silicone GT and TT. Silicone GT, red rubber JT, and polyvinylchloride TT were more secure than latex GT, silicone JT, and silicone TT, respectively.
Clinical Relevance— CFT should be preferred over FFS based on force and displacement to failure, but tube type and tissue reaction could influence anchoring strength.  相似文献   

8.
OBJECTIVE: To evaluate the effect of knotting method on the mechanical properties of large diameter nonabsorbable monofilament suture materials. STUDY DESIGN: In vitro mechanical evaluation. METHODS: A conventional square knot was compared with the surgeon's knot, sliding half-hitch, and clamped square knot. Knotted suture loops were created in a uniform manner and acutely tensioned to failure (20 mm/min loading rate; n = 20 per knot type for each material). Stiffness, yield, and failure characteristics of USP #2 nylon, #2 polybutester, #2 polypropylene, 27 kg test monofilament nylon fishing line, and 27 kg nylon leader material were evaluated. RESULTS: Compared with a conventional square knot, a surgeon's knot decreased stiffness for #2 polypropylene, 27 kg fishing line, and 27 kg leader (P < .05). A sliding half-hitch weakened all materials except 27 kg leader (P < .05). Clamping the first throw of a square knot increased the stiffness of 27 kg leader loops (P < .05). CONCLUSIONS: Based on clinically relevant parameters (stiffness and yield), knotting method had no effect on #2 nylon and #2 polybutester. The surgeon's knot is not recommended for #2 polypropylene and 27 kg fishing line and leader material. A sliding half-hitch decreased the yield of leader material. Clamping the first throw of a square knot had no adverse effects on acute properties of tested materials; it increased the stiffness for leader material. CLINICAL RELEVANCE: Knotting method does influence the structural properties of suture materials and should be considered when tying knots under tension.  相似文献   

9.
O bjectives : To compare the results of urine and plasma ketone dip test in a group of diabetic cats with possible ketosis or ketoacidosis, using laboratory plasma β-hydroxybutyrate measurements as the gold standard.
M ethods : According to clinical examinations, plasma β-hydroxybutyrate measurements and venous blood gas analysis, 54 cats with diabetes mellitus were classified as non-ketotic (n=3), ketotic (n=40) or ketoacidotic (n=11). Plasma and urine acetoacetate concentrations were determined using urine reagent strips.
R esults : Although there was a significant positive correlation between blood and urine ketone measurements (r=0·695, P<0·001), the results differed significantly (Z=−3·494, P<0·001). Using the differential positive rates, the best cut-off value to detect cats with ketoacidosis was 1·5 mmol/l for urine and 4 mmol/l for plasma. The sensitivity/specificity was 82/95 per cent for urine and 100/88 per cent for plasma, respectively.
C linical S ignificance : The urine and plasma ketone dip tests have a different diagnostic accuracy, and results have to be interpreted differently. Because of its high sensitivity, the plasma ketone dip test performs better than the urine ketone dip test to identify cats with impending or established ketoacidosis.  相似文献   

10.
OBJECTIVE: To evaluate the mechanical properties of the 18 and 36 kg Securos Cranial Cruciate Ligament Repair System. STUDY DESIGN: In vitro mechanical evaluation. SAMPLE POPULATION: Loop constructs of 18, 27, and 36 kilogram test (kgt) nylon leader line (NLL) secured with Securos crimp-clamps (SCC, n=40 per NLL test weight) or by a clamped square knot (CSK; n=40/NLL test weight). METHODS: The 36 kg SCC were used for the 27 and 36 kgt NLL, and 18 kg SCC were used for the 18 kgt NLL. Loop constructs were mounted on a material testing machine, and distracted at 500 mm/min for static tests, and for cyclic tests at 500 mm/min to a distraction limit of 6 mm (18 kgt) or 7.5 mm (27 and 36 kgt) for 49 cycles, until failure. Constructs were tested at 20 degrees C except for 1 group of 27 kgt CSK loops tested at 40 degrees C. Load at failure, elongation, and stiffness was recorded and compared between groups under static or cyclic testing conditions. RESULTS: All 27 and 36 kgt loops failed by disruption of NLL contained within the knot or crimp-clamp, whereas 18 kgt SCC loops failed by the NLL pulling through the crimp-clamp. The 18 kg SCC loops had considerable variability in ultimate load and elongation (coefficient of variation 29.6% and 18.3%, respectively). There was no significant difference in elongation between 27.3 kgt CSK loops tested at 20 degrees C and 40 degrees C. Generally, in both static and cyclic testing, SCC constructs formed with 27.3 or 36.4 kgt NLL performed as well or better than CSK constructs, resulting in loops that were strong, underwent minimal elongation, and had high stiffness. CONCLUSION: The results support use of the 36 kg Securos system but not the 18 kg Securos system (with the clamp and crimping device used). The significantly lower load required for failure, slippage through the clamp, and substantial variability suggested that the crimp tube diameter or the crimping device tested may be inappropriate for use with 18 kgt NLL. CLINICAL RELEVANCE: Surgeons should be aware that crimp-clamp design is important in controlling suture slippage or breakage within the clamp, and that novel systems should undergo mechanical testing with the size suture material they are intended to secure before clinical use.  相似文献   

11.
Objective— To describe the safety, surgical time, and complications associated with 3 techniques for achieving hemostasis during laparoscopic-assisted ovariohysterectomy (LAOVH).
Study Design— Prospective, randomized clinical trial.
Animals— Female dogs ( n =30).
Methods— Dogs were randomly assigned to 1 of 3 methods for achieving ovarian pedicle hemostasis during LAOVH: extracorporeal modified Roeder knot application (suture group), metal clip application using a multifire 10 mm laparoscopic clip applier (clip group), or use of a novel 5 mm bipolar vessel-sealing device (vessel-sealing group). In all dogs a 3 median portal technique was used.
Results— Controlling for the dogs' bodyweights, there was a significant association between surgical time and which method for hemostasis was used. This association was different when comparing the first 5 procedures using each method to the second 5. For a 20 kg dog, the surgical time (95% CI) for the first 5 procedures was 80 (69–91), 68 (57–79), and 33 (21–45) minutes for the suture, clip, and vessel-sealing groups, respectively. For the second 5 procedures surgical time was 71 (60–81), 50 (39–60), and 40 (29–51) minutes. Pedicle hemorrhage occurred in all dogs in the clip group, 3 dogs in the suture group, and none of the dogs in the vessel-sealing group although in all cases was considered hemodynamically inconsequential. All dogs recovered uneventfully.
Conclusions— All methods of hemostasis were safe for pedicle sectioning. A learning curve exists for clip and suture methods.
Clinical Relevance— Use of a vessel-sealing device significantly shortens surgical time and provides excellent hemostasis during LAOVH.  相似文献   

12.
Objective— To compare mechanical stability between a novel polypropylene mesh repair (Mesh), a modified 3-loop pulley suture (Suture), and a combination of the techniques (Suture+Mesh) for the repair of distal canine Achilles' tendon ruptures.
Study Design— In vitro mechanical evaluation.
Sample Population— Cadaveric canine Achilles' tendon/calcaneus units (n=34).
Methods— Constructs were loaded under tension to failure in a materials testing machine with synchronized kinematic analysis. Ultimate load to failure, global construct stiffness, and force required to reach 1 and 3 mm gap formation was recorded.
Results— Ultimate load to failure was greatest for the Suture+Mesh group and lowest for the Suture group. The Suture+Mesh technique afforded a significantly greater global stiffness than the Suture or Mesh treatments. Force to generate 1 and 3 mm gap formation was greatest with the Suture group.
Conclusions— The Suture+Mesh group had the highest ultimate load to failure and afforded the greatest global stiffness though it had no added benefit to resist local gap formation at the repair.
Clinical Relevance— Achilles' ruptures repaired with suture can be augmented with mesh to increase the ultimate load to failure, but as currently tested, there was a decrease in resistance to gap formation At this time we cannot recommend Mesh or the Suture+Mesh techniques without further testing.  相似文献   

13.
O bjectives : The objective of this study was to describe initial and long-term results of open reduction and transarticular pinning for treatment of coxofemoral luxations in cats.
M ethods : Cats were treated by open reduction and transarticular pinning for coxofemoral luxation over a five year period at two institutions. Follow-up assessment included orthopaedic examination, radiography and owner questionnaires.
R esults : Twenty cats were included in the study (14 males and six females). One cat was affected bilaterally. Mean time to follow-up was 21 months. Seventeen joints were stabilised with a 1·6 mm pin, three with 2·0 mm pins and a 1·2 mm pin was used in the remaining joint. An Ehmer sling was not utilised in any case. All transarticular pins except one were removed (mean 3·5 weeks), with all hips still in reduction The overall success rate was 77 per cent, with two reluxations and one resorbed femoral head noted on radiographs of 13 joints followed long term. All 20 owners reported good to excellent long-term functional outcome for their cats.
C linical S ignificance : Results from this study indicate that transarticular pinning for stabilisation of coxofemoral luxation in cats can provide a good long-term outcome without sacrificing the integrity of the coxofemoral joint.  相似文献   

14.
OBJECTIVE: To compare bursting strength and failure modes of ventral median abdominal incisions closed with loop suture in a simple continuous pattern using two different suture-bite intervals. STUDY DESIGN: In vitro experiment. SAMPLE POPULATION: Equine cadavers (n=14; weighing >318 kg; postmortem interval <2 hours). METHODS: A template was used to make a 25 cm incision with suture interval and bite size of either 1.0 cm x 1.5 cm or 1.5 cm x 1.5 cm. A 200 L polyurethane bladder was inserted within the abdomen and insufflated to create abdominal wall tension. Celiotomies were closed with a #2 braided lactomer 9-1 continuous pattern with a loop suture. Deviation from the linea, closure time (minutes), total suture length (cm), suture length to wound ratio (SL:WL), bursting pressure (mm Hg), and failure modes (fascial or suture) were compared between groups using a Mann-Whitney U test. Significance was set at P<.05. RESULTS: No significant differences were identified between closing time, total suture length used, SL:WL, bursting pressure, or failure mode. Fascial failure was the main failure mode for both techniques; suture failure occurred rarely and knot failure did not occur. CONCLUSION: Based on the overall bursting pressure and failure mode, #2 braided lactomer loop suture placed in a continuous pattern should provide sufficient security for closure of the equine linea alba during recovery and the immediate postoperative period. CLINICAL RELEVANCE: Although there were no significant differences in the 2 patterns evaluated, the 1.5 cm x 1.5 cm pattern may have potential advantages for closure time, less total suture remaining in the wound, and strength.  相似文献   

15.
O bjectives : To assess rate and quality of recovery from anaesthesia where isoflurane was delivered in oxygen or oxygen/nitrous oxide.
M ethods : Dogs anaesthetised with propofol were randomly allocated to receive isoflurane maintenance in either 100 per cent oxygen (group 1) or 66 per cent nitrous oxide (N2O)/34 per cent oxygen (group 2). Time from end of anaesthesia to achieving sternal recumbency was recorded. Incidence of adverse behaviours (vocalisation, uncontrolled head movement and restlessness) were assessed. Recovery quality was recorded on a visual analogue scale (VAS) (anchored at 0 with "best possible" recovery and "did not recover" at 100 mm). Age, weight, gender, anaesthetic duration, mean vaporiser setting, VAS scores, recovery times, postoperative temperature and behavioural scores were compared (chi-squared test, Mann-Whitney U test or t -test as appropriate, significance P≤0·05).
R esults : Objective data from 54 dogs were analysed, only VAS data where the observer was unaware of treatment group were used (n=33). Recovery was faster in group 2 dogs (median 10 min [range 4 to 31] compared with 14 minutes [3 to 43] in group 1, P=0·049) with less restlessness (0 [0 to 4] compared with 2 [0 to 4] in group 1, P=0·013) and uncontrolled head movement (0 [0 to 4] compared with 1 [0 to 3] in group 1, P<0·001). However, VAS scores were not statistically different between groups (group 1: mean 39·4 mm [s.d. 24·0)]; group 2: 30·1 mm [25·9]; P=0·303).
C linical S ignificance : Addition of N2O to isoflurane anaesthesia results in a lower incidence of adverse behaviour (for example restlessness) and marginally faster recovery.  相似文献   

16.
OBJECTIVE: To evaluate the effects of ethylene oxide and gas-plasma sterilization on the failure strength and failure mode of pre-tied monofilament ligature loops. STUDY DESIGN: A randomized block design was used by blocking for suture (size 1 polyglyconate, size 2 polydioxanone) and sterilization technique (control, ethylene oxide, gas plasma). SAMPLE POPULATION: Twenty replicates of each suture-sterilization technique combination. METHODS: Ligature loops were pre-tied using a 4S-modified Roeder knot then exposed to 1 of 3 treatments (control, ethylene oxide, or gas-plasma sterilization). Ligature loops were mounted onto a mechanical testing machine to evaluate the effects of sterilization on failure strength and failure mode (disruption, untying). RESULTS: There were no differences between polydioxanone and polyglyconate suture materials in failure strength or mode within sterilization methods. Both sterilization methods significantly increased the likelihood that suture loops would untie compared with controls subjects. Ligature loops that disrupted had a greater breaking strength than those that untied, regardless of sterilization method or suture type. CONCLUSIONS/CLINICAL RELEVANCE: Sterilization with either ethylene oxide or gas plasma of pre-tied, polyglyconate, or polydioxanone ligature loops significantly increases the in vitro likelihood of a modified Roeder knot untying. Further studies need to be conducted to determine the in vivo requirements for ligature loops.  相似文献   

17.
O bjectives : To investigate whether elevated canine pancreatic lipase immunoreactivity (CPLI) concentrations in dogs with inflammatory bowel disease (IBD) is associated with a worse clinical outcome.
M ethods : Serum CPLI assays were performed on serum stored from cases diagnosed with IBD. Thirty-two dogs with CPLI results within the reference range were designated as the control group and 15 dogs had CPLI above the reference range. Clinical signs, age, serum lipase and amylase activities, serum albumin and cobalamin concentrations, abdominal ultrasound examination, histopathology on small intestinal biopsies, management of IBD and outcome were compared between the two groups.
R esults : No significant differences were found in clinical activity score (P=0·54), number of antibiotic-responsive disease cases (P=0·480), number of steroid-responsive disease cases (P=0·491), serum amylase activity (P=0·058), serum cobalamin concentration (P=0·61), serum albumin concentration (P=0·052), abdominal ultrasound score (P=0·23) and histopathology scores for IBD (P=0·74) between the two groups. Dogs with increased CPLI concentration were significantly older and had a higher serum lipase activity than dogs with a CPLI concentration within the normal reference range (P=0·001, P=0·001, respectively). Moreover, dogs with increased CPLI concentration responded poorly to steroid treatment (P=0·01) and were significantly more likely to be euthanased at follow-up (P=0·02).
C linical S ignificance : CPLI should be measured in cases of canine IBD as elevated CPLI was associated with a worse outcome.  相似文献   

18.
O bjectives : To characterise the distribution of meticillin-resistant Staphylococcus aureus within the environment of a university small animal hospital and compare this with the distribution among staff.
M ethods : Samples were collected from 140 environmental sites and the anterior nares of 64 staff members at the University of Glasgow Small Animal Hospital on a single day (d1). Sixty of the environmental sites were resampled 14 days later (d14).
R esults : Meticillin-resistant S aureus was isolated from two of 140 (1·4 per cent; 95 per cent confidence interval: 1·7 to 5·1) environmental sites on d1 and one of 60 (1·7 per cent; 95 per cent confidence interval: 0·4 to 8·9) on d14. Two of the 64 staff sampled were positive for meticillin-resistant S aureus (3·1 per cent; 95 per cent confidence interval: 0·4 to 8·4).
C linical S ignificance : A lower prevalence of meticillin-resistant S aureus was observed in the environment than previously reported. The location, relatedness between isolates and the presence of Panton-Valentine leucocidin indicates that the source of the environmental meticillin-resistant S aureus was most likely to have been human rather than animal in these cases. This study presents important information regarding the potential source and distribution of meticillin-resistant S aureus within veterinary hospital environments and highlights potential variability of prevalence of meticillin-resistant S aureus within and between veterinary institutions.  相似文献   

19.
O bjectives : To establish the proportion of cytology samples sent to a commercial veterinary laboratory that yields diagnostically useful information in the context of current use and perceptions of cytology.
M ethods : Nine hundred and forty-five cytology submissions were retrospectively collected and categorised according to diagnostic utility. A survey into the use and perceptions of cytology was distributed at the British Small Animal Veterinary Association Congress 2008.
R esults : A specific diagnosis was reached in 23·1 per cent of samples and a cytological diagnosis in 35·3 per cent. 22·4 per cent of samples yielded some useful information, but 19·2 per cent were unacceptable. Seventy-four participants in the survey took an average of 3·9 cytological samples per week, of which they examined 27·0 per cent in-house only, 21·6 per cent in-house before sending to an external laboratory and 51·4 per cent were sent externally without prior examination. "To obtain a definitive diagnosis" was the principal reason cited for performing cytology.
C linical S ignificance : Results suggest that cytology is underused and may be applied in an inappropriate context in the UK. It is hoped that illustrating the diagnostic outcome of samples received by a commercial laboratory will encourage increased, appropriate use of cytology.  相似文献   

20.
O bjectives : Dyspnoea is an unspecific severe presenting sign, which can be life threatening and requires prompt treatment. Dyspnoeic cats often have significant underlying disease. Underlying aetiologies in cats that presented with dyspnoea were reviewed, and associations with patient signalment and outcome were investigated.
M ethods : The case records of 90 dyspnoeic cats were retrospectively reviewed and separated into different groups depending on aetiology (cardiac, respiratory, neoplastic and trauma). Duration of clinical signs, presentation, hospitalisation length and survival were analysed.
R esults : Cardiac (38 per cent), respiratory (32 per cent) and neoplastic (20 per cent) diseases were common causes of feline dyspnoea. Cats with respiratory causes had longer duration of clinical signs (P<0·001) before presentation. Cats with neoplasia were significantly older (P<0·001). No significant difference in respiratory rates was present between the groups (P = 0·154). High heart rates (P<0·001) and abnormalities on cardiac auscultation were more likely in the cardiac group.
Clinical Significance: Frequent causes of dyspnoea in cats were cardiac disease followed by respiratory causes and neoplastic conditions. Heart rate on presentation and presence of heart murmurs or gallops are useful to identify cardiac causes. Improved proportion surviving was found in the respiratory group (P = 0·027), whereas cats with neoplasia had the worst outcome.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号