首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Objective: To describe successful treatment of third-degree atrioventricular (AV) block using temporary noninvasive transthoracic pacing and placement of a permanent transvenous pacemaker in a case of suspected lily-of-the-valley ( Convallaria majalis ) intoxication in a dog.
Case summary: A 2-year-old neutered male Beagle weighing 17.8 kg was presented to the emergency service for treatment of bradycardia, vomiting, and lethargy. An electrocardiogram revealed third-degree AV block that was nonresponsive to atropine. Ten hours after admission, the dog became obtunded. Treatment initially consisted of temporary noninvasive transthoracic pacing and eventually placement of a permanent transvenous pacemaker. The initial history did not suggest that the dog had access to any known cardiotoxins. However, C. majalis , which contains cardiac glycosides, was identified within the dog's environment and the dog's serum did contain digoxin or an immunologically cross-reactive compound.
New or unique information provided: This is the first reported successful management of C. majalis toxicosis in a dog. Temporary noninvasive transthoracic pacing was used in the management of this case as a safe and effective bridge to permanent pacemaker implantation.  相似文献   

2.
Difficulty was encountered with the insertion of a right atrial pacing lead via the left jugular vein during lead and pacemaker implantation in a clinically normal goat as part of an ongoing rapid atrial pacing – induced atrial fibrillation research project. Fluoroscopic visualization of an abnormal lead advancement path prompted angiographic assessment which revealed a persistent left cranial vena cava (PLCVC) and prominent coronary sinus communicating with the right atrium. Angiography facilitated successful advancement and securing of the pacing lead into the right side of the interatrial septum. Cardiac magnetic resonance imaging/magnetic resonance angiography (MRI/MRA) allowed further characterization of this rare venous anomaly. Even though PLCVC has been reported once in a goat, to the authors' knowledge this is the first report to include MRI/MRA characterization of PLCVC and prominent coronary sinus with successful cardiac pacemaker implantation using the PLCVC.  相似文献   

3.
Permanent Transvenous Pacemaker Implantation in Forty Dogs   总被引:1,自引:0,他引:1  
Permanent transvenous cardiac pacemakers were implanted in 40 dogs. Electrocardiographic diagnoses included persistent atrial standstill (3 dogs), sick sinus syndrome (8 dogs), and high-grade second-degree or third-degree atrioventricular (AV) block (29 dogs). Thirteen dogs were alive and well 4 to 42 months after pacemaker implantation (mean, 16.9 months). The mean and median survival times of the 26 dogs that died or were euthanatized during the study were 17.9 months and 13 months, respectively. Most of these dogs succumbed to problems unrelated to the arrhythmia and pacemaker implant. One dog was lost to follow-up. Complications associated with permanent transvenous pacemaker implantation included lead dislodgement, infection, hematoma formation, skeletal muscle stimulation, ventricular arrhythmia, migration of the pulse generator, and skin erosion. Lead dislodgement was the most common complication, occurring in 7 of 9 dogs paced using untined electrode leads and in 6 of 30 dogs paced using tined leads. Lead dislodgement did not occur in the only dog paced using an actively fixed endocardial lead. It was concluded that permanent transvenous cardiac pacing is a feasible, less traumatic alternative to epimyocardial pacing in dogs, but that successful use of this technique requires careful implantation technique and anticipation of the potential complications.  相似文献   

4.
Transvenous pacing therapy is a life-saving technique for patients with clinically significant bradyarrhythmias. For most symptomatic bradyarrhythmias in small animals, there is no effective substitute for cardiac pacing. The methods employed for pacemaker placement, although potentially time-consuming, are not technically difficult. This article discusses the indications, techniques, clinical decision-making, and potential complications associated with temporary and permanent transvenous cardiac pacing.  相似文献   

5.
Transvenous cardiac pacing in 19 dogs and one cat   总被引:2,自引:0,他引:2  
Eighteen dogs and one cat with symptomatic bradycardias were equipped with cardiac pacemakers. One further dog died during anaesthesia for pacemaker placement. Each animal was sedated, and a ‘tined’ transvenous pacing lead was passed to the apex of the right ventricle from the jugular vein. Following temporary pacing and general anaesthesia, the permanent pacemaker was placed subcutaneously at the neck in the dogs and at the abdominal wall in the cat. In 11 dogs and the cat, the pacemaker was implanted in a dacron pouch. Complications (mainly serous reaction to the pacemaker) developed in four out of seven dogs in which no pouch had been employed. The pacing lead was retained after discharge from hospital in all except one dog. Pacing successfully relieved clinical signs in all cases. Fifteen out of 18 dogs and the cat survived one year after pacing and the mean survival time was greater than 18 months. Transvenous pacing is a simple and reliable technique that avoids transthoracic or transabdominal surgery for pacemaker lead placement.  相似文献   

6.
OBJECTIVE: To determine whether dobutamine stress tests (DST) can be used to detect cardiac dysfunction in dogs with early left ventricular dysfunction (ELVD) induced by rapid right ventricular pacing (RRVP). ANIMALS: 7 adult male Beagles. PROCEDURE: A pacemaker was surgically implanted in each dog at the level of the right ventricular apex. Electrocardiography, Doppler sphygmomanometry, and Doppler echocardiography were performed before and during a DST prior to activation of the pacemaker and every 3 to 4 days during the period of RRVP. Dobutamine stress tests were performed by infusing dobutamine at incremental dosages ranging from 12.5 to 42.5 microg/kg of body weight/min. RESULTS: Clinical signs of congestive heart failure were not observed during the pacing period. However, all dogs developed ELVD associated with significant changes in values for most Doppler echocardiographic variables obtained prior to DST Adverse cardiac effects were not detected during DST. Most Doppler echocardiographic indices of cardiac function were significantly altered in response to dobutamine infusion during the pacing period, compared with prepacing values. However, a dobutamine-induced 2-fold increase in cardiac output was maintained. CONCLUSIONS AND CLINICAL RELEVANCE: Dobutamine stress tests can be safely performed in dogs with experimentally induced ELVD. Dobutamine stress tests may be a sensitive, noninvasive diagnostic method, complementary to standard clinical examinations, for detection of early cardiac dysfunction in dogs asymptomatic for dilated cardiomyopathy.  相似文献   

7.
Background: Pacemaker implantation is the treatment of choice for symptomatic bradyarrhythmias. In dogs, a single chamber system is commonly used. In human patients with high-grade 2nd- or 3rd-degree atrioventricular (AV) block, physiologic pacing is recommended, because it improves cardiac output, blood pressure, exercise tolerance, and quality of life. In dogs, this type of pacing is seldom used.
Hypothesis: The implantation of a dual chamber pacemaker in dogs with AV block is a feasible procedure for restoring AV synchrony.
Animals: Thirty-three privately owned dogs with high-grade 2nd- or 3rd-degree AV block were included.
Methods: Patient data of all dogs with AV block presented for pacemaker implantation between December 1997 and November 2004 were reviewed.
Results: Dual chamber pacemaker implantation with AV synchronous stimulation was successfully performed in 33/33 dogs (100%). In 9/33 (27%) major and in 12/33 (36%) minor complications were observed. Mean survival time for the patients discharged from hospital (n = 32) was 33.6 ± 20.4 months (range, 3.9–83.5 months).
Conclusion and Clinical Importance: Dual chamber pacing is a feasible procedure in dogs with 2nd- or 3rd-degree AV block and is not associated with a higher complication rate compared with single chamber pacemaker systems. A major advantage over ventricular demand pacemaker systems is the restoration of AV synchrony for a substantial period of time.  相似文献   

8.
A 14.5-kg, 13-year-old female spayed Cocker spaniel was evaluated because of episodic hind limb weakness. Results of examination were consistent with sick sinus syndrome with intermittent second-degree atrioventricular block. Transesophageal atrial pacing was successful in providing chronotropic support during permanent pacemaker implantation. Transesophageal atrial pacing appears to be a viable option for temporary atrial pacing in dogs with hemodynamically marked bradycardia without significant atrioventricular blockade.  相似文献   

9.
Temporary cardiac pacing is used in the emergency treatment of life-threatening bradyarrhythmias and for the support of heart rate and blood pressure of patients with sick sinus syndrome or high-grade atrioventricular (AV) block undergoing general anesthesia, typically for permanent pacemaker implantation. We retrospectively evaluated the safety and efficacy of a noninvasive transthoracic external cardiac pacing system in 42 dogs treated for bradyarrhythmias. Optimal placement of the patch electrodes on the skin of the thorax was initially established on 2 anesthetized normal dogs. The optimal electrode placement was determined to be on the right and left hemithoraces, directly over the heart. Afterward, by means of this electrode placement all 42 dogs treated for bradyarrhythmias in this study were successfully paced with the noninvasive transthoracic system. Dogs ranged in age from 1 to 15 years and weighed between 3.2 and 40 kg. Miniature Schnauzers, German Shepherds, and mixed breeds were most common in the study population. Indications for noninvasive transthoracic pacing included emergency treatment of hemodynamically unstable 3rd-degree AV block (2 dogs): support of heart rate during general anesthesia for permanent pacemaker implantation or lead-wire adjustment (38 dogs): and support of heart rate during general anesthesia for ophthalmologic surgery in dogs with sick sinus syndrome (2 dogs). Complications included pain and skeletal muscle stimulation, which required general anesthesia. We conclude that the noninvasive transthoracic pacing system evaluated is satisfactory for clinical veterinary use.  相似文献   

10.
Objective: This case report presents the clinical findings of a dog with diltiazem intoxication and the utilization of temporary transvenous pacing for management of high‐grade second‐degree atrioventricular (AV) block with associated bradycardia and hypotension. Case summary: A nine‐year‐old spayed female Basset Hound, who ingested between 95 and 109 mg/kg of sustained‐release diltiazem exhibited clinical signs of cardiac arrhythmias, bradycardia, hypotension, mental depression and gastrointestinal (GI) upset. Bradycardia was present initially, then was followed by high‐grade second‐degree AV block with ventricular escape. Traditional medications to treat calcium channel blocker (CCB) intoxication, including atropine, calcium gluconate, dopamine and glucagon were initially successful in managing the cardiac rhythm disturbances and hypotension. Twenty‐two hours post‐ingestion, however, the dog became refractory to these medications following sedation for GI decontamination and a temporary transvenous pacemaker was placed. The dog was paced for 19 hours. Transvenous pacing effectively increased heart rate, which increased blood pressure into an acceptable range. The dog was successfully discharged from the hospital following treatment. New or unique information provided: The use of a temporary pacemaker should be considered an acceptable treatment for bradycardia, AV block and hypotension associated with CCB intoxication when conventional medical therapy fails.  相似文献   

11.
Pacemakers are commonly implanted by veterinary cardiologists in dogs with bradyarrhythmias. In the past, these pacemakers were placed with little attention to programming except for the basic heart rate. However, the availability of pacing programmers has permitted a better appreciation of the needs for proper and safe pacing in dogs. An awareness of the problems that can result from improper programming is imperative. We report the identification of noise reversion (inappropriate asynchronous pacing) in 42% of dogs consecutively paced (n = 19) at Cornell University during a 2 year period. Noise reversion is the operation that causes the pacemaker to switch to asynchronous pacing with repetitive refractory sensing. It was developed as a protective mechanism against noise being mistaken for cardiac events with the consequence of inhibition of pacing. However, in the dog, this operation can cause inappropriate, and potentially dangerous pacing. In the dog, this common complication is associated with the coexistence of a bradycardia and tachycardia. Proper programming of the refractory period (shortening) in conjunction with the sensitivity (decreasing the sensitivity) can eliminate noise reversion in dogs with both ventricular and atrial pacing.  相似文献   

12.
A collie-cross dog with syncopal attacks associated with total atrioventricular heart block was successfully fitted with a programmable, ‘physiological’ pacemaker, employing atrial sensing and ventricular pacing leads. Transvenous placement of leads under sedation and local analgesia, followed by temporary pacing, then general anaesthesia for the fitting of a permanent pacemaker, offers advantages over epicardial pacing. The use of a ‘tined’ ventricular lead appears to reduce the risk of lead displacement.  相似文献   

13.
A 10-year old male mongrel dog was presented to the University Veterinary Teaching Hospital with a two-month history of episodic syncope. Twenty-four hr Holter electrocardiographic (ECG) recording revealed frequent episodes of advanced atrioventriculer block with long periods of ventricular asystole. The cause of syncope was determined to be Adams-Stokes syndrome exhibited bradyarrhythmia. After the animal failed to respond to medical therapy, permanent transvenous pacemaker implantation was performed. Postoperative Holter ECG showed 100 beat per min programmed pacemaker rhythm, which indicated successful capture of the artificial pacing. The dog recovered smoothly from the operation and syncopal episodes completely disappeared. Six months after the surgery, no complications were observed and the dog's quality of life has dramatically improved.  相似文献   

14.
Historically, ventricular demand, nonphysiologic (VVI) pacing has been the most commonly used modality to treat 3rd-degree atrioventricular (AV) block. The goal of this study was to determine the feasibility of using a commercial, single-lead, physiologic (VDD) pacemaker in dogs with 3rd-degree AV block. Furthermore, we hoped to characterize and identify differences in the radiographic, echocardiographic, neurohormonal, and quality of life consequences of physiologic versus nonphysiologic pacing. We evaluated 10 dogs during a 12-week crossover study. Acutely, rate-matched physiologic pacing reduced pulmonary capillary wedge pressure by 19% compared with nonphysiologic pacing. VDD pacing significantly reduced left atrial size normalized to body weight, left atrial-to-aortic root ratio, and left ventricular end-systolic dimension and increased fractional shortening, aortic Doppler velocity, cardiac output, and stroke volume compared with VVI pacing. Variable rate VDD pacing resulted in a significantly slower heart rate (HR) during echocardiography than fixed-rate (100 bpm) VVI pacing. AV synchronous pacing reduced circulating N-terminal proatrial natriuretic peptide (ANP), norepinephrine (NOR), and epinephrine (EPI) concentrations compared with asynchronous pacing. There were no significant differences in systemic blood pressure, thoracic radiographs, or owner-perceived quality of life. The median percentage of AV synchronous pacing during the VDD modality was 99.8% (range, 1.2 to 99.9%). This study confirms the potential to achieve physiologic pacing with a commercial, single-lead system in dogs. VDD pacing improved hemodynamics and neurohormonal profiles over asynchronous pacing although the long-term clinical benefits of these changes remain to be determined.  相似文献   

15.
ObjectiveThere is little information in the veterinary literature about the perioperative management of small animal patients with previously implanted pacemakers undergoing elective or emergency non-cardiac procedures. The purpose of this article is to review the current literature with regard to human patients, with previously implanted pacemakers, undergoing general anaesthesia. Using this and the current information on pacemakers and anaesthesia in dogs and cats, we provide recommendations for small animal patients in this situation.Databases usedGoogle Scholar, PubMed and CAB Abstracts using and interlinking and narrowing the search terms: “dog”, “cat”, “small animals”, “anaesthesia”, “pacemaker”, “perioperative”, “transvenous pacing”, “temporary pacing”. Scientific reports and human and small animal studies from the reference lists of the retrieved papers were reviewed. In addition, related human and veterinary cardiology and anaesthesia textbooks were also included to create a narrative review of the subject.ConclusionsThe best perioperative care for these animals comes from a multidisciplinary approach involving the anaesthetist, cardiologist, surgeon and intensive care unit team. When such an approach is not feasible, the anaesthetist should be familiar with pacemaker technology and how to avoid perioperative complications such as electromagnetic interference, lead damage and reprogramming of the device. The preanaesthetic assessment should be thorough. Information regarding the indication for pacemaker placement, complications during the procedure, location, type and programming of the pacemaker should be readily available. The anaesthetic management of these veterinary patients aims to preserve cardiovascular function while avoiding hypotension, and backup pacing should be available during the perioperative period. Further prospective studies are needed to describe the best perioperative care in small animals with a previously implanted pacemaker.  相似文献   

16.
BACKGROUND: Extradural lidocaine exerts several adverse effects which are seldom fatal. While cardiac arrest following extradural lidocaine injection has been reported in human beings, it has not hitherto been reported in dogs. OBSERVATIONS: The emergency management of a dog with complete urethral obstruction is described. We intended to perform vaginoscopy and cystostomy under extradural lidocaine anaesthesia, but cardiac asystole occurred a few minutes after injection. Resuscitation was successful. About 20 minutes later cardiac arrest recurred, and was treated successfully. The dog remained hypothermic for approximately 7 hours. Complete recovery without neurological deficit occurred the next day and the dog remained normal for at least 3 months. The probable cause of the problem was cranial lidocaine dispersion causing a drop in cardiac preload and cardiac arrest. The successful neurological outcome was attributed to early diagnosis and effective treatment. Hypothermia may have conferred cerebral protection during ischemia. CONCLUSIONS: Extradural local anaesthetic administration is not without risk and the technique should be tailored to individual animals. Constant monitoring is required to detect potentially fatal complications and increase the likelihood of successful outcome.  相似文献   

17.
IntroductionIn dogs, single lead ventricular pacing, ventricular sensing, inhibition response, rate adaptive (VVIR) pacemakers are routinely used to treat third degree atrioventricular block. The objectives of this study were to investigate the heart rate distribution in dogs with VVIR pacemakers, and report changes when activity settings were adjusted.AnimalsEighteen client-owned dogs with VVIR pacemakers for third degree atrioventricular block.Materials and methodsThis observational study consisted of a review of medical records of dogs with VVIR pacemakers. For dogs with >50% of paced beats at the lower pacing rate, the activity daily living (ADL) and exertion responses were increased. Re-evaluations were performed after 6–12 months.ResultsHeart rate distribution similar to healthy dogs was absent for all dogs. In nine dogs, the ADL and exertion responses were increased to the highest level. Of these, three dogs showed no improvement in heart rate distribution; for two dogs, one with an epicardial pacemaker, several activity settings were adjusted and pacing at higher heart rates was observed at re-evaluation. Four dogs died or were lost to follow-up. Clinical signs had resolved for all dogs after pacemaker implantation.ConclusionDefault activity settings of VVIR pacemakers do not result in heart rate distribution equivalent to healthy dogs. Increasing the ADL and exertion response settings to the highest levels did not improve the pacemaker rate response. Further investigations into the role of dog size, generator positioning, pacemaker settings, and whether rate responsiveness is required for dogs' quality and quantity of life are warranted.  相似文献   

18.
The case reported herein describes the placement of a permanent transvenous pacemaker in an older dog with a previously undiagnosed persistent left cranial vena cava (PLCVC) and recent onset symptomatic third-degree atrioventricular (AV) block. On presentation the dog was found to have atrial flutter and third-degree AV block and echocardiography demonstrated evidence of chronic valvular disease and pulmonary arterial hypertension. The persistent left cranial vena cava was discovered via angiography when difficulties were encountered with pacemaker placement. Successful right ventricular pacing necessitated passage of the lead through the coronary sinus. The attendant complications in pacemaker placement in the presence of a PLCVC are well-described in man but, to the authors' knowledge, have not been described in companion animals.  相似文献   

19.

Background

Increased cardiac troponin I (cTnI) concentration has been reported in dogs with atrioventricular (AV) block before and shortly following pacemaker implantation. The role of AV dyssynchrony, age, or concurrent cardiac disease on cTnI concentration remains unknown.

Objectives

To investigate change in cTnI concentration following dual-chamber pacemaker implantation on short- and long-term follow-up and to compare cTnI values to a case-matched control group.

Animals

Thirty-eight client-owned dogs with permanent AV block and 38 matched control dogs.

Methods

Retrospective review of medical records. Pacemaker group consisted of dogs with AV block and dual-chamber pacing. Control group matched the study population in age and cardiac disease. cTnI was compared between pacemaker and control group on short- and long-term follow-up. Different lead types and influence of arrhythmia on cTnI were tested.

Results

cTnI was high at presentation (median 0.66 ng/ml; range 0.03–18.6) and showed a significant reduction over time after pacemaker implantation (p < 0.0001). Median cTnI values were significantly different between pacemaker and control group on short-term (p = 0.0004; 0.11 ng/ml, range 0.03–1.36 versus 0.06 ng/ml, range 0.03–0.46), but not on long-term follow-up (p = 0.0547; 0.14 ng/ml, range 0.03–0.73 versus 0.07 ng/ml, range 0.03–0.46). Lead type and severity of arrhythmia did not show a significant correlation to cTnI concentration.

Conclusions

On long-term follow-up, cTnI remained mildly elevated in some of the pacemaker dogs but was not significantly different to the matched control group.  相似文献   

20.
Transcutaneous cardiac pacing (TCP) can be used in dogs with a high risk for bradyarrhythmias prior to anesthesia, either in an emergency room or intensive care unit setting. Furthermore, TCP can also be used on patients diagnosed with bradyarrhythmias that require temporary pacing at the induction of anesthesia for the implantation of a permanent pacemaker. Despite the importance of TCP in emergency medicine, no studies have evaluated the optimal size and placement of the transdermal electrodes crucial for the efficacy of TCP in dogs.This study evaluated four different sizes of electrodes (10.5, 20, 30 and 40 cm2), and four different anatomical sites (anterior–posterior, left–right, apex–base, modified left–right) in order to optimize the efficacy of TCP in dogs. Electrodes with a surface area of 20 cm2 and a modified left–right placement minimized the pacing current and involuntary skeletal muscular contraction (muscular twitching) and so achieved the most optimal effect of TCP in dogs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号