首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
To adapt to the continuous improvement of rural power consumption level in the new rural construction,in particular,with the continuous development of the rural economy,the actual operation of the rural power network has emerged as the high loss of electrical power which leads to a greater cost of the electricity,lower power supply reliability,the supply voltage and frequency do not satisfiy with requirements,etc.Through analysis of a typical rural power network,from the overall planning of the transmission to distribution equipments(such as lines,transformers and reactive-load compensation devices),the author proposes some specific measures such as reducing power loss and improving the voltage quality and reliability methods.Through calculation for lines power loss rate and percent of voltage pass,the results show that the methods proposed by the author are effective.The directions to the development trend of the rural power network is given.  相似文献   

2.
The voltage instability of power system often occurs when the active power on one or more weak branches exceeds its transfer capability. A preventive control model for static voltage stability is proposed using the active power transfer capability of weak branches as static voltage stability constraints. A local line based voltage stability index is used to determine the critical contingencies, weak branches and transfer capability of each weak branch. A static security analysis method, which is based on DC power flow equations, is used to establish the non linear active power flow expressions on weak branches following each critical contingency. The active power constraints on weak branches can be obtained from the active power flow expressions and transfer capabilities of weak branches. A quadratic optimal model for preventive control including the proposed active power constraints on weak branches is presented. The simulation results for IEEEE14 bus system and IEEE118 bus system demonstrate the correctness and effectiveness of the proposed preventive control model.  相似文献   

3.
Focusing on a continuously variable transmission(CVT) hybrid electric vehicle with integrate starter generator(ISG), modeling and simulating of engine braking was conducted. An optical control strategy of regenerative braking was put forward. When there is no regenerative braking, engine brake force can be used effectively by changing the CVT ratio to reduce the braking force requirements for wheel brakes based on the calculated results of engine braking. When there is regenerative braking, the braking priority sequence is generator braking, engine braking, and finally frictional braking. A forward simulation model for regenerative braking system of hybrid electric vehicle was built. The simulation and analysis under typical driving cycles was conducted. The result shows the control strategy and the models are reasonable and feasible.  相似文献   

4.
dSPACE is a prototype development and real-time control testing platform which is based on MATLAB/Simulink software. By establishing mathematic model of hydraulic automatic transmission system, the shift rules are achieved. A testing platform for hydraulic automatic transmission system is developed whose control software is programmed by simulink and using the dSPACE as the centre controller. The experiment of electric throttle control and power performance matching control of hydraulic automatic transmission system is carried out. the result shows that well matching performance of hydraulic automatic transmission system can be realizedby using the control strategy proposed in this paper, it provides a fast and efficient approach for researching and developing the hydraulic automatic transmission system.  相似文献   

5.
A new approach based on sensitivity method for the optimal power flow is presented in the paper. This method has the following advantages: it is suitable to solve a 200-node power system on the microcomputer; the convergence is easy to reach and the computation speed is quick; it is possible to reduce 8-14% power loss and to get maximum economic benefit by using this method; in power system dispatch center it can be used as an on-line voltage and reactive power control program to keep good voltage level. The proposed method has been proved successful by IEEE 118-node test system and the several real power systems such as 49-node, 61-node, 99-node and 200-node systems.  相似文献   

6.
Secondary Voltage Control is a new way of voltage control,firstly the power system is divided into many control areas whose electric distance is remote.The partitioning method of secondary voltage control is studied and an algorithm that combination of the threshold search and dynamic scatter is presented.That is,the initial grouping scheme is obtained by searching the threshold value.The dynamic scatter method then is used to regulate and improve the initial results.The method is based on system's physical character,it's unnecessary to modify the network's model and analysis the eigenvalue,so the compute rate is fast.Through comparing the method and the traditional methods,this method is proved to be a reasonable and feasible partitioning scheme.  相似文献   

7.
Based on the reactive surplus of Chongqing 220 kV main electric power network under low water and low load, and on state of higher system voltage, a thorough research is done on voltage and reactive power of the system power network by means of calculation,analysis and experiments. A main network calculating equivalence model of power network in Chongqing is constructed. And reactive power optimizing calculation is figured out on the Chongqing power network on condition that the loss minimum of the active power network is object function. Several optimizing compensatory schemes are put forward. Based on the calculation result and the analysis of all schemes, the most reasonable and feasible optimizing scheme could be achieved. Meanwhile, the feasibility that the system voltage could be adjusted when generator operating under excitation was demonstrated. According to the experience of under-excitation operation of the same type units , it decreases the system voltage, improves Chongqing power network running performance, and strengthens the coordination and stabilization of system.  相似文献   

8.
A FPGA based multi channel cortical stimulator system for cortical visual prosthesis was designed. devised for generating a sequence of electrical pulses for cortical stimulation. The simulator is composed of a FPGA and voltage/current converters. The FPGA comprises a spike generator to generate various electrical pulse sequences and some multiplexers to select signals. The prototype based on an Altera Cyclone EP1C6 FPGA with four channels is developed to perform the experimental evaluation. Two electrode chips ane put out of the left and right dura of cortex of a cat. The electrical stimulation is connected to the left one, while the visual electrically evoked potential (EEP) is recorded by the right one. The experimental results on cat's cortex show that the cortex can respond to the current stimulation.  相似文献   

9.
This paper proposes a control scheme for a doubly-fed induction generator (DFIG) wind farm with VSC-HVDC grid integration to ensure secure and reliable operation of power system with fluctuated wind power penetration. The whole system dynamic models are respectively described. Based on vector control system with a virtual voltage orientation, a steady-state voltage control block and a dynamic voltage control block with a cross-product term of d-q currents are separately designed for WFVSC to control the corresponding parts of the wind farm voltage. Meanwhile, with the consideration of AC and DC side parameter variation and external disturbance, an improved backstepping control scheme with Lyapunov stability provement is also proposed for the GSVSC. The combination of the two schemes makes up the new control design of this study. Besides, to verify the performance of the proposed new control design, three different cases are suggested which contain the AC and DC side parameter variation and external disturbance such as local load cut off-in, grid voltage harmonics. Finally, numerical simulations using MATLAB/Simulink are presented for a 200MW DFIG wind farm with VSC-HVDC grid integration to validate the proposed control scheme and demonstrate the improved system operation performance. Moreover, the corresponding discussions are also presented for further illustrations.  相似文献   

10.
To solve the problem of low control accuracy and low stability of current X-ray machines, a kind of digital power supply for X-ray machine is introduced. In the digital power supply, some key technologies are used to improve the output stability of the high frequency inverter, including improved BUCK circuit for voltage regulating circuit, high frequency inverter and soft switching technology for the high-voltage generator. The PWM control technology is used to control the switch transistor of voltage regulating circuit and inverter circuit, which makes the drive waveform output stable and easy to control. In order to improve the control accuracy, reduce the volume and change high voltage consecutively, the software PID of the microcomputer is used to control the feedback circuit. The high-accuracy power chip is used for the filament power supply to make the filament electric current stable. Through the analysis of the circuit, the parameters of the circuit are calculated and the circuit is simulated by PSPICE software. The results show that the theoretical analysis is consistent with the practical simulation results. The design can meet the requirement of the technology indices of the power supply of the X-ray machines.  相似文献   

11.
针对DFIG(double fed induction generator)风电机组低电压穿越能力(LVRT,low voltage ride through)问题,笔者基于STATCOM研究了一种电压外环与电流内环相结合的双闭环反馈控制策略,并仿真验证了所提出方法的有效性。将STATCOM分别安装风电机组机端、并网点高压侧和低压侧,且设置不同电压跌落深度,比较其补偿效果。实验结果表明,安装在风电机组机端时补偿效果最好。在电网电压跌落时,STATCOM能快速为电网输入无功,抬高风力机的机端电压,从而提高风电场的LVRT能力,从STATCOM输出无功大小和风电场机端电压被抬升的比例两方面分析,对于不同深度的电压跌落,STATCOM补偿效果都较为显著。  相似文献   

12.
It is very difficult to build the accurate mathematical model of the wind turbine generator system because of the uncertainty of air kinetics and the complexity of power electronics, especially when the wind speed changes abruptly or there is a disturbance. But the classical control needs the model. Using neural network controller to the wind turbine generator system can overcome these difficulties. The wind speed can be followed and the maximum power can be obtained under low wind speed by using the power coefficient curve BP neural network and the optimum pitch angle BP neural network. The maximum power can be kept and under the allowed range in the condition of high wind speed. The simulation model and result are given under the environment of MATLAB. The fluctuation of wind speed can be controlled and the disturbance can be cancelled by BP neural network controller.  相似文献   

13.
The utilization of Flexible AC Transimssion System(FACTS)technology has significant impact on power system reliability performance.Series FACTS devices such as Thyristor Controlled Phase Shifting Transformers(TCPSTs) and Thyristor Controlled Series Compensators(TCSCs) can change the natural allocation of the power flow and effectively alleviate transmission congestion.Parallel FACTS devices such as Static Var Compensators(SVCs)can provide reactive power support and maintain voltage stability.So it is important to quantitatively evaluate their benefits to the power system reliability.The traditional models of the composite generation and transmission system reliability evaluation are mainly focused on conventional generation and transmission facilities.This paper researches the power flow model of TCPST and TCSC,and then presents the optimal load shedding model incorporating TCPSTs,TCSCs and SVCs and effectively incorporates them into the reliability evaluation model.The proposed method is tested on the RBTS and the obtained results show that the system reliability can be improved effectually by FACTS devices.  相似文献   

14.
This paper researches the fuzzy control and simulation of regulating system for PMSM in electrical vehicle. The mathematics model is set up.The PMSM,the PMSM measures demux, dq to abc converter and the three phrase PWM converter models are set up in MATLAB/ Simulink. The fuzzy controller is designed with two dimension fuzzy design method, and take E and EC as input variable, U is the output variable. According to the controller and models, the fuzzy control model of regulating system for PMSM is created in matlab/simulink. At last, to test the accuracy of the control method with the simulation result.  相似文献   

15.
提出了一种包含了逆变器接口(voltage source inverter,VSI)、同步电机接口(synchronous generator,SG)的独立微网控制策略,并分析了其小信号稳定性。VSI接口和SG接口的分布式电源均采用下垂控制策略,二者之间无需实时通信,可实现负荷功率共享。建立了系统的小信号状态空间模型,主要包括:同步发电机及其控制器的小信号模型、逆变器及其控制器的小信号模型、电网络及负荷小信号模型。计算了下垂增益变化时的根轨迹,得到了系统主特征值随参数变化的根轨迹,计算了不同状态变量对特征值的参与因子。稳定性分析结果表明:当所有分布式电源采用下垂控制时,引入同步发电机接口的分布式电源,系统频率小信号稳定性大大增强。PSCAD时域仿真验证了特征值计算的正确性。  相似文献   

16.
In order to resolve the hazard of biofouling and scale in circulating cooling water system of power stations, this paper takes the lead in combining high voltage pulses and high frequency pulses for sterilization and descaling process. It analyzes both electromagnetic effects and biochemical effects on sterilizing and descaling process caused by the high voltage pulses and high frequency pulses respectively. The pulse generator is designed according to the requirements of electromagnetic parameters for effective operation. The design and improvement of process chambers are assisted by electromagnetic field simulation technology. Experimental data prove that the system can output high voltage pulse whose maximum peak value reaches 7 kV and high frequency pulse whose maximum peak value reaches 100 V the frequency ranges from 500 kHz to 2 MHz. The rate of sterilization can be as high as 91,and the rate of descaling reaches 71. This system is expected to achieve the standards of industrial water treatment through further research.  相似文献   

17.
In need of ultra-high frequency partial discharge location and correction of electrical equipment, we designed a sub-nanosecond steep pulse generator, and constructed the corresponding circuit model through the circuit simulation software Pspice. The influence of the storage capacitor and the supply voltage to the pulse waveform is analyzed. When the storage capacitor is 10 pF and 20pF respectively, the output pulse waveforms have been measured in the conditions of pulse rise time being 0.68 ns and 0.90 ns, pulse width being 0.98 ns and 1.18 ns, pulse peek being 8.72 V and 12.2 V respectively, and partical discharge capacity of charge being 320 pC and 600 pC. The picked multi-pulse singnals are steady with the developped sleeve monopole antenna, the error is less than 70 ps. It can be used for the experimental study of ultra-high frequency partial discharge location and correction of electrical equipment.  相似文献   

18.
Yangtze River is abundant of water and can provide enough water as cooling and heating source for water source heat pumps (WSHP). A pair of contrast experiments with open loop system and close loop system of WSHP were finished in order to get the heat pump's COP, the system's COP and the distribution of water temperature in the heat exchanger etc. This paper compared the characteristic and the COP of these two kinds of system. The heat pump's COP of the open loop system and close loop System are 3.08 and 3.77 respectively, and the system's COP are 2.83 and 2.80 respectively. At last, applications of open loop system and close loop System of WSHP at Yangtze River were analyzed and the key problem for attention was pointed out in the paper.   相似文献   

19.
The governing system of hydraulic turbine generator plays an important role in power system. It is significant to find out the faults of governing system and remove them quickly. This paper sets up a new fault diagnosis model of the hydraulic turbine generator governing system with the advanced ANN (artificial neural net). This 17-in-13-out model consists of three layers. It is proved that this model can find the fault accurately.  相似文献   

20.
陈钊 《保鲜与加工》2016,(2):58-63,106
针对国内冲击发电机性能参数不足,以国外冲击发电机作为试验电源,建立基于直接试验法的矿用高压开关电器短路开断与关合试验系统,提出了一种新的技术解决方案。仿真试验结果表明,该方案满足综合性煤矿高压电气实验室建设项目技术指标和试验标准要求,为大容量开断与关合试验系统设计和建造提供一种技术思路。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号