共查询到17条相似文献,搜索用时 15 毫秒
1.
A method is described for preparing latex particles sensitized with IgG antibody (IgG-sensitized latex) applicable to the slide reversed passive agglutination (RPLA) test. Soap-free latex (latex) was sensitized with IgG which had been isolated from rabbit anti-bovine lactoferrin serum using protein A Sepharose CL 4B. Unadsorbed protein-binding sites on the surface of latex were blocked with bovine serum albumin (BSA). IgG-sensitized latex that gave better agglutination in RPLA could be selectively obtained by centrifugation at 19 900g for 15 min in 0.01 mol/L glycine buffer (pH 7.3; specific gravity 1.042) containing 3% NaCl, 5% saccharose and 2% choline chloride. By dispersing this IgG-sensitized latex in 0.01 mol/L glycine buffer (pH 7.3) containing 1–2% BSA, a uniformly suspended, highly reactive, readily agglutinable preparation was obtained. 相似文献
2.
用血凝抑制试验 (HI)和乳胶凝集试验 (LAT)两种方法检测乙型脑炎弱毒疫苗免疫猪血清 ,结果均呈阳性反应。用LAT对来自 12个猪场的 94份猪血清进行了乙型脑炎病毒 (JEV)抗体检测 ,并与HI进行了对比 ,两种方法检测结果阳性符合率和总符合率分别为 90 .3% (5 6 /6 2 )和 88.3% (83/94 ) ,两种方法检测结果差异不显著 (p >0 .0 5 )。对来自无乙型脑炎的 12头健康猪血清进行检测 ,两种方法检测结果均为阴性。结果表明 ,用LAT与HI检测乙型脑炎结果符合 ,前者更为简便和实用。 相似文献
3.
Differences in antigenicity between human and canine C-reactive proteins were investigated by Western blotting analysis. It was confirmed that several commercial anti-human CRP sera reacted with canine CRP. However, 34 anti-canine CRP sera prepared by immunization of rabbits and goats with canine CRP all reacted with canine CRP but not with human CRP in either immunoelectrophoresis or Western blotting.Immunization with human CRP produced a cross-reacting antibody that reacted with canine CRP. Conversely, immunization with canine CRP did not produce a cross-reacting antibody that reacted with human CRP. These findings may be interpreted as showing that, while canine and human CRPs do not share common antigenicity, they do contain structurally similar antigenic determinants.Abbreviations CRP
C-reactive protein
- PBS
phosphate-buffered saline
- SDS-PAGE
sodium dodecyl sulphate-polyacrylamide gel electrophoresis 相似文献
4.
Background: Serum C-reactive protein (CRP) is an acute phase marker in dogs that is useful for the diagnosis and monitoring of inflammatory disease. Rapid, reliable, and automated assays are preferable for routine evaluation of canine serum CRP concentration. Objective: The aim of this study was to evaluate whether canine serum CRP concentration could be measured reliably using an automated turbidometric immunoassay (TIA) designed for use with human serum. Methods: A commercially available TIA for human serum CRP (Bayer, Newbury, UK) was used to measure canine serum CRP concentration. Cross-reactivity of antigen was evaluated by the Ouchterlony procedure. Intra-and interassay imprecision was investigated by multiple measurements on canine serum samples and serum pools, respectively. Assay inaccuracy was investigated by linearity under dilution and comparison of methodologies (canine CRP ELISA, Tridelta Development Ltd, Kildare, UK). Then the assay was applied to serum samples from 14 clinically healthy dogs, 11 dogs with neoplasia, 13 with infections, 8 with endocrine or metabolic diseases, and 10 with miscellaneous diseases. Results: Cross-reactivity between canine serum CRP and the anti-human CRP antibody was found. Intra-and interassay imprecision ranged from 5.2% to 10.8% and 3.0% to 10.2%, respectively. Serum CRP concentration was measured in a linear and proportional manner. There was no significant disagreement and there was linear correlation of the results in the comparison of methodologies, except for a slight proportional discrepancy at low CRP concentrations (<10 μg/mL). Dogs with infections had a significantly higher concentration of serum CRP than did all other dogs, and dogs with neoplasia had a significantly higher concentration of serum CRP than did clinically healthy dogs. Conclusions: Canine serum CRP concentration can be measured reliably using the commercially available TIA designed for human CRP. 相似文献
5.
Study objectives were to investigate whether C-reactive protein (CRP) in pig saliva could be quantified using an adapted, time-resolved immunofluorometry assay (TR-IFMA), and to determine whether the assay could distinguish healthy from diseased animals. The test method had intra- and inter-assay coefficients of variation of 5.75% and 9.73%, respectively, the limit of detection was 0.47 ng/mL and the coefficient of determination was 0.98. Analysis of CRP concentrations in paired serum and saliva samples from 50 pigs gave a positive correlation ( r = 0.702, P < 0.01) and the salivary CRP concentration was able to distinguish healthy from diseased animals in 62 samples from pigs with naturally occurring or experimentally-induced inflammation. The results suggest that this minimally invasive, straightforward and sensitive assay may be useful in pig health and welfare monitoring. 相似文献
6.
OBJECTIVE: To compare a recently developed recombinant MSP-5 competitive inhibition ELISA with a card agglutination test for detection of antibodies to Anaplasma marginale and Anaplasma centrale in Australian cattle. MATERIALS AND METHODS: The ELISA was compared with the card agglutination test using 208 sera from cattle in Anaplasma-free herds, 86 sera from cattle experimentally infected with A marginale or A centrale and 757 sera from cattle in areas endemic for A marginale. RESULTS: The specificity of the ELISA, based on testing 208 sera from cattle in Anaplasma-free areas, was 99.5%, and the sensitivities for detection of antibodies to A marginale and A centrale in sera from the experimentally infected cattle were 98.0% and 100%, respectively. For the same sets of sera, the specificity of the card agglutination test was 98.6% and the sensitivities for detection of antibodies to A marginale and A centrale were 98.0% and 100%, respectively. For the 757 sera collected from cattle in areas endemic for A marginale, the agreement between the ELISA and the card agglutination test depended on the positive threshold selected for the ELISA. The maximum achievable agreement was 91.5% (kappa = 0.73; 95% confidence interval 0.66, 0.79). CONCLUSION: We conclude that the competitive inhibition ELISA is a useful alternative to the card agglutination test for detection of A marginale or A centrale infection in cattle. The assay should be particularly useful for epidemiological applications such as prevalence studies and control programs. 相似文献
7.
Leptospirosis is an exacerbating factor responsible for the drastic decline of sloth bear population in India. In this study, a multipronged approach based on antigen detection using Polymerase Chain Reaction (PCR) employing G1/G2 and LigBF/LigBR primers, antibody detection using Microscopic Agglutination Test (MAT) and recombinant LigBCon1-5 antigen based Latex Agglutination Test (rLigBCon1-5 LAT), serum biochemistry using hepatic (serum glutamate oxalo acetic transaminase (SGOT) and serum glutamate pyruvic transaminase (SGPT) and renal biomarkers (blood urea nitrogen (BUN) and Creatinine) and gross/histopathological evidence in liver and kidneys were employed to investigate leptospirosis in captive sloth bears. A total of 133 serum samples collected from Agra (n=113) and Bannerghatta (n=20) sloth bear rescue centers were screened using MAT and rLigBCon1-5 LAT. A total of 87 and 78 sera tested positive by MAT and LAT respectively. Pyrogenes was the leading serovar obtained using MAT followed by Icterohaemorrhagiae, Javanica, Grippotyphosa, Canicola and Tarassovi. The relative sensitivity, specificity and accuracy of rLigBCon1-5 LAT in comparison to MAT were 89.66%, 100% and 93.23% respectively. PCR performed on hepatic and renal tissues showed amplicon of 285 and 219 base pairs for G1/G2 and LigBF/LigBR primers respectively. Gross evidence (icteric liver, severely engorged hepatic sinusoids, congested kidneys with necrotic white spots on sub capsular surface), histopathology (severe hepatic degeneration and tubulointerstitial nephritis) and elevated hepatic/renal biomarkers were suggestive of leptospirosis. This study suggests that rLigBCon1-5 LAT can be employed as a pen-side test for detecting leptospirosis in sloth bears. 相似文献
8.
Eight Beagle dogs were inoculated intrabronchially with 5×10 9 live, avirulent cells of Bordetella bronchiseptica L-414 strain (phase I cells) ( B. bronchiseptica) to investigate the serum levels of their C-reactive protein, the white blood cell counts, the antibody responses to B. bronchiseptica in the sera and tracheal secretions, and the effects of prednisolone given to four of the dogs on C-reactive protein (CRP), white blood cells (WBC) and immune responses. In two Beagle dogs inoculated intrabronchially with sterile physiological saline, the concentrations of CRP and the WBC counts did not increase. CRP was markedly increased one day after inoculation in the dogs inoculated with B. bronchiseptica to 385.0–720.0 µg/ml (mean 498±132 µg/ml) in the group given the B. bronchiseptica inoculation only, and to 372.0–649.0 µg/ml (mean 551±106 µg/ml) in the group treated with prednisolone following inoculation of B. bronchiseptica, as determined by an enzyme-linked immunosorbent assay (ELISA). The CRP levels were 23–95 times the pre-inoculation values, which indicated that prednisolone had no effect on the production of CRP. In the prednisolone-treated group, the WBC count increased and stayed at an increased level for approximately 12 days. An indirect fluorescent antibody test led to the detection of anti- B. bronchiseptica IgM and IgG antibodies in the sera from 5 days after B. bronchiseptica inoculation and S-IgA and IgG anti- B. bronchiseptica antibodies in the tracheal secretions on the day after the challenge exposure to B. bronchiseptica. The increase in CRP after challenge exposure to B. bronchiseptica was significantly ( p<0.05) smaller than that found after the first inoculation of B. bronchiseptica.Abbreviations CRP
C-reactive protein
- ELISA
enzyme-linked immunosorbent assay
- FHA
filamentous haemagglutinin
- IFA
indirect fluorescent antibody
- WBC
white blood cell(s) 相似文献
10.
A time-resolved immunofluorometric assay (TR-IFMA) was developed for the determination of C-reactive protein (CRP) in canine
serum. CRP was isolated from canine acute-phase serum by affinity chromatography on agarose coupled with phosphorylethanolamine.
This isolated dog CRP was used as standard to calibrate the assay. Intra-assay and inter-assay coefficients of variation were
in the ranges 5.3–7.1% and 4.8–13.3%, respectively. Accuracy, evaluated by adding 2 and 10 μg/ml of CRP to serum samples,
provided recoveries of 99.9% and 106.8%. High correlation was found between CRP measurements by TR-IFMA and a by commercial
enzyme-linked immunosorbent assay ( R2 = 0.98). The limit of detection for the TR-IFMA method was 0.000067 μg/ml and the measurement of CRP in serial dilutions
of acute-phase dog sera generated curves with the same slope as the one constructed with purified CRP. The TR-IFMA provides
a precise, accurate and highly sensitive assay for CRP determination in dog samples. CRP levels in dogs with different diseases
ranged between 10.2 and 210.7 μg/ml and were significantly higher than those observed in healthy dogs (< 7.1 μmg/ml). 相似文献
11.
BACKGROUND: Anaplasma phagocytophilum (formerly known as the human granulocytic ehrlichia, Ehrlichia equi and Ehrlichia phagocytophila) is an obligate intracellular organism causing clinical disease in humans and various species of domestic animals. OBJECTIVES: The objectives of this investigation were to sequence and clone the major surface protein 5 (MSP5) of A phagocytophilum and to evaluate the suitability of this antigen in the serologic diagnosis of anaplasmosis in humans and dogs. METHODS: The msp5 gene of A phagocytophilum was sequenced, cloned, and expressed in Escherichia coli. The predicted amino acid sequence homology of the various MSP5/major antigenic protein 2 orthologs was compared among various Anaplasma and Ehrlichia species. Recombinant MSP5 of A phagocytophilum was used in an ELISA to detect antibodies in serum samples from humans and dogs infected with the organism. RESULTS: Serum samples from 104 individuals previously diagnosed with A phagocytophilum infection, as well as samples from clinically healthy humans, were tested. In addition, multiple samples from 4 dogs experimentally infected with 2 different geographic isolates of A phagocytophilum and 5 dogs naturally infected with a Swiss isolate were tested using ELISA. Using this group of immunofluorescent antibody test-positive and immunofluorescent antibody test-negative samples, we found the overall agreement between assays to be >90%. CONCLUSIONS: These results indicate that recombinant MSP5 has potential for use as a diagnostic test antigen to detect infection with A phagocytophilum in both dogs and humans. However, sequence similarities among orthologs of MSP5 in related species of anaplasma and ehrlichia suggest that cross-reactivity among these pathogens is likely if the entire peptide is used as a test antigen. 相似文献
12.
A sheep trial was performed to standardise a coproantigen reduction test (CRT) protocol for the diagnosis of resistance to triclabendazole (TCBZ) in Fasciola hepatica). The CRT employs the BIO K201 Fasciola coproantigen ELISA (Bio-X Diagnostics, Jemelle, Belgium) to test for the presence of F. hepatica coproantigens in a faecal sample. If it is coproantigen-positive, the CRT protocol recommends that faecal samples are re-tested for coproantigens at 14 days post-treatment (dpt), with negative testing at this point indicating TCBZ success. Initial work aimed to confirm the sensitivity of the BIO K201 ELISA for Fasciola infection and investigate whether coproantigens represent a robust reduction marker of TCBZ efficacy. Thirty-eight, indoor-reared sheep were artificially infected with F. hepatica isolates known to be susceptible (Cullompton) and resistant (Sligo) to TCBZ action, respectively. Treatment was administered at 12 weeks post-infection (wpi), with 2 sheep groups, infected with each isolate, culled at 2 and 4 weeks post-treatment (wpt), respectively. Necropsy was performed to confirm treatment efficacy. Individual faecal samples were collected twice-weekly throughout the trial period. Additional work focused on the effect of temperature on faecal sample collection and storage. Faecal samples collected from sheep positive for F. hepatica infection were sub-sampled and left at room temperature. Individual sub-samples were tested by ELISA on consecutive days and these readings compared to the original test result on the day of collection. In addition, ELISA values were compared between faecal sub-samples prepared on the day of sampling and post storage at -20°C. Also, an immunocytochemical study was performed to determine the tissue site of origin of the coproantigen protein in the fluke. Results showed that the BIO K201 ELISA was sensitive for Fasciola coproantigens, with coproantigens detectable from 5 wpi onwards. The suitability of coproantigens as a diagnostic marker of TCBZ efficacy was supported by the absence and presence of coproantigens in TCBZ-treated Cullompton (TCBZ-susceptible) and Sligo (TCBZ-resistant) F. hepatica infections at 2 and 4 wpt, respectively. Study results suggest that low to moderate temperature has little, if any, impact on coproantigen stability in faecal samples, but that higher temperatures may have. Immunolabelling for the coproantigen showed that it was specific to the gastrodermal cells of both adult and juvenile flukes. 相似文献
13.
The diagnostic accuracies of the modified agglutination test (MAT) and indirect ELISA test for the detection of serum antibodies against Toxoplasma gondii in sheep were evaluated through Bayesian approaches on two populations of sheep created from three different groups of animals (T. gondii-aborted ewes, colostrums-deprived newborn lambs, and ewe-lambs and adult ewes with unknown T. gondii infection status). Tests showed a high degree of agreement (kappa statistic = 0.93; 95% confidence interval = 0.87, 0.98) and a significant specificity (Sp) correlation (gamma(Sp) = 0.26; 95% credibility interval = 0.017, 0.61). When prior information was used for all unknown parameters the posterior medians for the sensitivity (Se) and Sp of the MAT and ELISA were, respectively, 92.6% (95% credibility interval = 85.2, 96.9), 95.5% (89.9, 98.7), 90.5% (83.4, 95.6), and 97.8% (94.2, 99.5). These estimates remained similar when uninformative priors were included. The Se estimates of the MAT and ELISA were higher than those obtained on pigs in other study using the same approach (Se = 80.6% and Sp = 89.5% for the MAT, and Se = 71.5% and Sp = 85.5% for the ELISA [Georgiadis, M.P., Wesley, O.J., Gardner, I.A., Singh, R., 2003. Correlation-adjusted estimation of sensitivity and specificity of two diagnostic tests. Appl. Stat. 52, 63-78]. This finding supported the believe that test performances may vary when applied on different animal species. Thus, if these tests are planned to be used on animal species other than sheep or pigs, their diagnostic accuracy should be re-assessed to prevent biased inferences from their results. 相似文献
14.
Abstract AIM: To make valid recommendations on the use of serological test methods for the detection of serum antibodies in ruminants against Coxiella burnetii (Q-fever), by comparing the performance of the complement fixation test (CFT) and two ELISA, and by identifying reasons for discrepancies between the test methods. METHODS: A total of 73 serum samples from infected cattle, 69 from infected goats, and 100 samples from non-infected cattle and 57 samples from non-infected sheep, as well as 95 samples from infected cattle herds (mix of seropositive and seronegative samples), were tested using the CFT, the IDEXX ELISA (I-ELISA) and the Pourquier ELISA (P-ELISA). A mixed panel of 12 serum samples from sheep from inter-laboratory proficiency testing (proficiency panel) was also tested using the CFT and both ELISA, and further investigated using IgG- and IgM-specific ELISA. RESULTS: Generally, the two commercial ELISA were more sensitive than the CFT for the detection of infected ruminants. Good agreement between ELISA for positive and negative results was found for samples from the infected herd, while results for the positive panels varied between the two ELISA. For the total of the positive serum panels, the I-ELISA detected 95% of samples as positive or suspicious, while the P-ELISA detected only 81%. In the P-ELISA, more samples were considered suspicious (18%) than in the I-ELISA (14%). All sera from noninfected sheep and cattle tested negative in the serological test methods employed, except for one positive sample from a sheep in the P-ELISA. Further investigation revealed that a CFT-positive but ELISA-negative result was due to high IgM and low IgG reactivity. CONCLUSIONS: The two commercial ELISA were more sensitive than the CFT in all panels from infected ruminants. However, they could only detect IgG. The I-ELISA should be the serological test method of choice for cattle, sheep and goats for import testing of animals into New Zealand because it was more sensitive than the P-ELISA and was equally specific to the PELISA and the CFT. For other animal species, such as deer and camelids, the CFT should still be used since none of the ELISA has been evaluated for these species. This study has shown that the two commercial ELISA will detect the majority of infected ruminants but may miss animals that have not developed an IgG response. 相似文献
15.
Latent-class models were used to determine the sensitivity, specificity and predictive values of a polyclonal blocking enzyme-linked immunosorbent assay (ELISA) and a modified complement-fixation test (CFT) when there was no reference test. The tests were used for detection of antibodies against Actinobacillus pleuropneumoniae serotype 2 in a survey of respiratory diseases in Danish finishing pigs. The estimates were obtained by maximum-likelihood and also by a Bayesian method (implemented with Gibbs sampling). Possible dependence of diagnostic errors was investigated by comparing models where independence was assumed to models allowing for conditional dependence, given the true disease status. No strong evidence of conditional dependence in either test sensitivity or specificity was found. Assuming independence, maximum-likelihood estimates and 95% confidence intervals of the sensitivity and specificity of the ELISA were 100% and 92.8% (90.1–95.5%) and the corresponding values of the CFT were 90.6% (85.8–95.4%) and 98.6% (98.0–99.3%), respectively. Bayesian estimates and posterior 95% credible intervals of the sensitivity and specificity of the ELISA were 99.7% (98.7–100%) and 92.7% (89.9–95.3%) and of the CFT were 90.6% (86.0–95.3%) and 98.7% (98.0–99.3%). The sensitivity and specificity of a combined test, where the CFT is subsequently applied to the pig sera that test positive in the ELISA, were estimated at 90.2% (85.6–95.0%) and 99.9% (99.8–100%), respectively. The cost of the combined test was less than the cost of the use of the CFT alone, at prevalences <54%. Prevalences and predictive values and their 95% limits were estimated in six sub-samples of data. The estimates of sensitivity and specificity obtained in the present investigation generally validate those reported from other sources. 相似文献
16.
Latent-class models were used to determine the sensitivity, specificity and predictive values of a polyclonal blocking enzyme-linked immunosorbent assay (ELISA) and a modified complement-fixation test (CFT) when there was no reference test. The tests were used for detection of antibodies against Actinobacillus pleuropneumoniae serotype 2 in a survey of respiratory diseases in Danish finishing pigs. The estimates were obtained by maximum-likelihood and also by a Bayesian method (implemented with Gibbs sampling). Possible dependence of diagnostic errors was investigated by comparing models where independence was assumed to models allowing for conditional dependence, given the true disease status.No strong evidence of conditional dependence in either test sensitivity or specificity was found. Assuming independence, maximum-likelihood estimates and 95% confidence intervals of the sensitivity and specificity of the ELISA were 100% and 92.8% (90.1–95.5%) and the corresponding values of the CFT were 90.6% (85.8–95.4%) and 98.6% (98.0–99.3%), respectively. Bayesian estimates and posterior 95% credible intervals of the sensitivity and specificity of the ELISA were 99.7% (98.7–100%) and 92.7% (89.9–95.3%) and of the CFT were 90.6% (86.0–95.3%) and 98.7% (98.0–99.3%). The sensitivity and specificity of a combined test, where the CFT is subsequently applied to the pig sera that test positive in the ELISA, were estimated at 90.2% (85.6–95.0%) and 99.9% (99.8–100%), respectively. The cost of the combined test was less than the cost of the use of the CFT alone, at prevalences <54%. Prevalences and predictive values and their 95% limits were estimated in six sub-samples of data. The estimates of sensitivity and specificity obtained in the present investigation generally validate those reported from other sources. 相似文献
17.
From a series of studies on single nucleotide polymorphisms (SNPs) in the bovine growth hormone (GH) gene of Japanese Black cattle, the type‐C (127 Val and 172 Met) that is specific for this breed has been intensively focused upon because of the economic importance for carcass traits, such as intramuscular oleic acid contents. In the present study, we intended to analyze the 3‐D structure of GH of haplotype C, and developed a novel method to detect the type C gene. Three‐D analysis of the type C protein showed that the amino acid residues (127 Val and 172 Met), which are present in the third and fourth helixes, respectively, and are important for binding with GH receptors, are shifted to deeper positions in the molecule compared with that for type A (127 Leu and 172 Thr), implying the alteration of binding interaction with receptors. A novel, efficient and cost‐effective method (Dot‐blot‐SNP technique) for type C genotyping was successfully established, of which the basal method was a reported genotyping of SNPs for a large number of plants, reducing the cost to 10% or less of direct sequencing. 相似文献
|