首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A rapid immunochromatographic lateral flow test strip of competitive format has been developed for the specific determination of olaquindox (OLA) residues in pig urine and muscle tissues. The sensitivity of the test strip was found to be 1.58 ± 0.27 μg/kg and 1.70 ± 0.26 μg/kg of OLA in pig urine and muscle tissues, and the lower detection limit was 0.27 ± 0.08 μg/kg and 0.31 ± 0.07 μg/kg respectively. For negative pig urine and muscle samples spiked with 4, 12, and 36 μg/kg, the recovery range was 83.0-94.0% and 78.8-87.4% and the coefficient of variation scope [CV (%)] was 3.17-7.41% and 4.66-7.64% respectively. Parallel analysis of OLA samples from pig urine and muscle tissue showed comparable results from the test strip and HPLC. Each test requires 5-8 min, and the test strip can provide a useful screening method for quantitative, semiquantitative, or qualitative detection of OLA residues.  相似文献   

2.
A highly sensitive and rapid biosensor test based on disposable screen-printed thick-film electrodes was developed, which is suitable for monitoring organophosphate and carbamate residues in foods of animal origin with increased fat contents such as milk. The wild-type enzyme was combined with three engineered variants of Nippostrongylus brasiliensis acetylcholinesterase (NbAChE), to obtain enhanced sensitivity. The sample pretreatment could be reduced to a minimum. There was no extraction or fat removal necessary. With the biosensor test paraoxon concentrations down to 1 microg/L could be detected in milk. The detection limit for carbaryl was 20 microg/L. Recovery rates for paraoxon and carbaryl in milk samples lay between 89 and 107%. Ten milk samples from local markets were tested both with the biosensor test and with standard chromatographic multiresidue methods. Two milk samples caused AChE inhibition rates of >50%. Accordingly, 4 microg/L tebufenpyrad, 4 microg/L tetraconazole, and 2 microg/L bifenthrin were detected in one of these milk samples. The other milk sample contained 2 microg/L tebufenpyrad.  相似文献   

3.
This article presents the generation of monoclonal antibodies (mAbs) with high specificity against 19-nortestosterone (NT) through cell fusion techniques and the development of a mAb-based indirect competitive ELISA (icELISA) method and colloidal gold-based immuno-chromatographic assay to detect NT residues in beef and pork samples. A modified carbodiimide method was employed to synthesize the artificial antigen, and BALB/c mice were used to produce anti-NT mAbs. On the basis of the checkerboard titration, an indirect competitive ELISA standard curve was established. This assay was sensitive and had a linear range from 0.03 to 38 ng/mL in phosphate buffered saline (PBS), with IC(50) and LOD values of 0.52 ng/mL and 0.01 ng/mL, respectively. Of all the competitive analogues, the produced mAb exhibited a high cross-reactivity to 17α-nortestosterone (83.6%), the main metabolite of NT in animal tissues. Except for moderate cross-reactivities with trenbolone (22.6%) and β-boldenone (13.8%), the other interference to the assay was negligible (<0.05%). In contrast, the strip test had a visual detection limit of 1 ng/mL in PBS, 2 μg/kg in beef, and 2 μg/kg in pork, respectively, and the results can be judged within 10 min. The ELISA and GC-MS results showed close correlation in beef (R2=0.9945) and in pork (R2=0.9977). Therefore, the combination of two immunoassays provides a useful screening method for quantitative or qualitative detection of NT residues in animal-origin products.  相似文献   

4.
An immunochromatography (ICG) strip test for rapid detection of atrazine in water samples was developed. A monoclonal antibody (MAb) specific to atrazine was produced from the cloned hybridoma cell (AT-1-M3) and used to develop a direct competitive enzyme-linked immunosorbent assay (DC-ELISA) and ICG strip. MAb conjugated to colloidal gold, and that was applied to the conjugate pad of the ICG strip. The visual detection limit for the ICG strip was 3 ng/mL. This test required only 10 min to get results and one step of sample to perform the assay. The results of water samples spiked with 5, 10, 20, and 50 ng/mL of atrazine by ICG strip were in good agreement with those obtained by DC-ELISA. The ICG strip was sufficiently sensitive and accurate to be useful for rapid screening of atrazine in various water samples.  相似文献   

5.
该研究探索并构建一种基于历史数据分析的安全预警方法,对生鲜乳中兽药残留情况进行识别、控制与评价,以便在风险发生之前做出准确判断。首先利用高效液相色谱-高分辨飞行时间串联质谱(High Performance Liquid Chromatography-high Resolution Time-of-flight Tandem Mass Spectrometry,HPLC-TOF-MS/MS)方法对上海市各牧场的生鲜乳进行兽药残留筛查,然后以生鲜乳中泼尼松(Prednisone,Pre)残留检出数为例,利用休哈特控制图(Shewhart control charts)构建风险预警体系。结果表明:在300个生鲜乳样品中共筛查出42种兽药残留,涉及类固醇类(12种)、糖皮质类(6种)和镇静剂(5种)等12大类;在筛查的6个星期中,泼尼松检出数(Number of Prednisone Detected,Pn)控制图呈现稳定的状态;当假设第7周泼尼松检出数为6时,Pn控制图呈现稳态,未触发预警;当假设第7周泼尼松检出数为10时,Pn控制图出现异常,稳态遭到破坏,此时该批样品触发风险预警。综上,利用HPLC-TOF-MS/MS能对生鲜乳样品进行高通量的兽药残留筛查,再利用休哈特控制图结合历史数据可以对生鲜乳样品的兽药残留进行有效的风险监测和预警。  相似文献   

6.
A reliable, rapid, and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of chloramphenicol and aflatoxin M(1) in milk has been developed. This method includes simple extraction of sample with acetonitrile, separation on a MGIII-C(18) column using 5 mM ammonium acetate aqueous solution/methanol (60:40, v/v) as mobile phase, and MS/MS detection using multiple reaction monitoring mode. The method was validated according to Commission Decision 2002/657/EC. The limits of detection (LODs) were 0.05 μg/kg for chloramphenicol and 0.005 μg/kg for aflatoxin M(1.) The limits of quantification (LOQs) were 0.2 μg/kg for chloramphenicol and 0.02 μg/kg for aflatoxin M(1). The recovery values ranged from 88.8% to 100.6%, with relative standard deviation lower than 15% in all cases, when samples were fortified at three different concentrations. The decision limits (CCα) and detection capability (CCβ) of the method were also reported. This method has been successfully applied for simultaneous analysis of chloramphenicol and aflatoxin M(1) residues in milk from local supermarkets in China.  相似文献   

7.
An inexpensive and portable surface plasmon resonance (SPR) sensor, SPReeta Evaluation Kit SPR3, has been used to develop a biosensor for the determination of fluoroquinolone antibiotics (FQs) and to demonstrate its performance analyzing FQ residues in milk samples. The SPReeta three-channel gold chips were activated with a mixed self-assembled monolayer (m-SAM) and functionalized with a FQ haptenized protein. Binding of the antibody produced a concentration-dependent increase of the SPR signal as a result of the change in the refraction index. Similarly, the presence of the FQ produced a dose-dependent decrease of the response, which allowed a good limit of detection (LOD) to be obtained (1.0 ± 0.4 μg L(-1) for enrofloxacin in buffer). The response was reproducible in all three channels, on different injections and days, and also between chips. Milk samples could be analyzed after a simple sample treatment involving fat removal by centrifugation and dilution with water. Under these conditions calibration curves were obtained showing that FQ residues can be analyzed in milk samples with an IC(50) value of 26.4 ± 7.2 μg L(-1) and a LOD of 2.0 ± 0.2 μg L(-1) (for enrofloxacin), far below the European Union regulations for this antibiotic family in this matrix. Finally, the paper also demonstrates that the biosensor is able to selectively detect the presence of FQs in milk samples, even in the presence of other antibiotics. Enrofloxacin, ciprofloxacin, and norfloxacin residues were detected in blind samples supplied by Nestle? Co.  相似文献   

8.
Liquid chromatography-ion trap tandem mass spectrometry (LC-MS/MS) with electrospray ionization was used to identify cephapirin metabolites and degradants in milk from cows dosed with cephapirin. The milk was extracted according to a previously published procedure. Structures for various components were tentatively identified by their molecular weight, product ion mass spectra, and/or correspondence to standard mass spectra. These components may have occurred as metabolites or as degradants that occurred on storage or during extraction. Compounds identified in the milk included cephapirin, desacetylcephapirin, cephapirin lactone, hydrolyzed cephapirin, and a reduced cephapirin lactone that has not previously been reported. Methylcephapirin was also identified, possibly as a trace contaminant in the formulation. Analysis of incurred milk extracts showed that cephapirin and desacetylcephapirin are the major residues in milk. Desacetylcephapirin residues persisted about as long as the parent drug. The detection limit for both residues by LC-MS/MS was approximately 1 ng/mL in milk. These results have implications for microbiological methods or rapid test kits, if such methods or kits respond to cephapirin metabolites and degradants present in the milk.  相似文献   

9.
A new, rapid, and sensitive method was proposed for the determination of sulfonamide residues in milk and chicken muscle samples by microchip electrophoresis with laser-induced fluorescence detection. Separation of fluorescamine-labeled sulfonamides was accomplished by using a buffer containing 5 mmol/L boric acid and 1% (w/v) polyvinyl alcohol (PVA). The pH, amount of PVA, and concentration of boric acid in the running buffer were found to have great influence on the separation. By optimizing these conditions, the separation of four sulfonamides, sulfamethazine, sulfamethoxazole, sulfaquinoxaline, and sulfanilamide, was achieved within 1 min with limits of detection (S/N = 3) of 0.2-2.3 μg/L, which are well below the maximum residue limit. The proposed method also exhibited very good repeatability; the relative standard deviations for both within-day and between-day measurements were ≤3.0%. With a simplified sample pretreatment protocol, fast determination of sulfonamides in real samples was successfully performed with standard addition recoveries of 93.3-100.8 and 82.9-92.3%, respectively.  相似文献   

10.
The development of an assay for the detection of streptomycin residues in pasteurized whole milk using an optical biosensor (Biacore) is reported. Streptomycin-adipic hydrazide coupled to bovine thyroglobulin was used to produce a sheep polyclonal antibody. The antibody displayed excellent cross-reactivity with dihydrostreptomycin (106%). There was no significant cross-reaction with other aminoglycosides or common antibiotics. Streptomycin was also immobilized onto a CM5 sensor chip to provide a stable, reusable surface. The developed assay permitted the direct analysis of whole milk samples ( approximately 3.5% fat) without prior centrifugation and defatting. Results were available in 5 min. The limit of detection of the assay was determined as 4.1 ng/mL, well below the European maximum residue limit (MRL) of 200 ng/mL. Repeatability (or coefficient of variation) between runs was determined as 3.5% (100 ng/mL; 0.5 x MRL), 5.7% (200 ng/mL; MRL), and 7.6% (400 ng/mL; 2 x MRL).  相似文献   

11.
A gas chromatographic method is described for the analysis of human milk to determine polychlorinated biphenyls (PCBs) as 72 congeners plus p,p'-DDE, mirex, hexachlorobenzene, and octachlorostyrene. The detection limit for individual compounds is about 0.05 ng/g when 30 g milk is analyzed. Total PCBs can be estimated with a detection limit of 1-5 ng/mL milk. Analytical precision is better than +/- 10% for all compounds at 20-50 ng/mL whole milk.  相似文献   

12.
A method was developed and validated to determine 5-hydroxyflunixin in raw bovine milk using liquid chromatography tandem mass spectrometry (LC/MS/MS). The mean recovery and percentage coefficient of variation (%CV) of 35 determinations for 5-hydroxyflunixin was 101% (5% CV). The theoretical limit of detection was 0.2 ppb with a validated lower limit of quantitation of 1 ppb and an upper limit of 150 ppb. Accuracy, precision, linearity, specificity, ruggedness, and storage stability were demonstrated. A LC/MS/MS confirmatory method using the extraction steps of the determinative method was developed and validated for 5-hydroxyflunixin in milk from cattle. Briefly, the determinative and confirmatory methods were based on an initial solvent (acetone/ethyl acetate) precipitation/extraction of acidified whole milk. The solvent precipitation/extraction effectively removed incurred ((14)C) residues from milk samples. The organic extract was then purified by solid phase extraction (SPE) using a strong cation exchange cartridge (sulfonic acid). The final SPE-purified sample was analyzed using LC/MS/MS. The methods are rapid, sensitive, and selective and provide for the determination and confirmation of 5-hydroxyflunixin at the 1 and 2 ppb levels, respectively.  相似文献   

13.
用BSA-pAPB免疫Balb/c小鼠,用细胞融合技术制备并用间接ELISA和阻断ELISA筛选抗苯巴比妥单克隆抗体(PB mAb)杂交瘤细胞株,体内诱生腹水法生产PB mAb,应用PB mAb研制PB残留竞争ELISA(ciELISA)快速检测试剂盒(PB-Kit),并测定其性能。结果表明,筛选出3株杂交瘤细胞,最好的3F6-C4株的PB mAb间接ELISA效价为1∶6.4×105,亲和常数(Ka)为1.96×1010 L/moL,半数抑制浓度(IC50)为5.7 μg/L,与巴比妥的交叉反应率(CR%)12.4%,与其它化合物无CR;PB-Kit的线性检测范围1.0~81 μg/L,灵敏度0.75 μg/L,检测限1 μg/L;饲料样和猪尿样的平均添加回收率85.8%和91.3%,平均批内和批间变异系数均<15%。PB-Kit具有快速、敏感、特异、简便等特点,适合PB残留快速检测的推广应用。  相似文献   

14.
A rapid and simple immunochemical method was developed for the assessment of the creatine kinase (MM) isoenzyme [CK(MM)], a protein marker linked with animal welfare and meat quality. The one-step time-resolved immunofluorometric assay produced quantitative results from serum or whole blood samples in 20 min. The analytical limit of detection (mean + 2s) for the immunoassay was 17 ng/mL (n = 6), and the functional limit of detection for the analysis of porcine whole blood samples was 426 ng/mL (n = 24). The working range of the method was linear up to 50 micro g/mL, and the within-assay precision varied between 2.1 and 10.9%. The analysis of porcine serum samples showed that the results from the immunoassay method and colorimetric CK enzyme activity determination were highly correlated (r(2) = 0.965, n = 17, p < 0.001). The practicability of the assay was demonstrated by the analysis of 300 porcine whole blood samples in a slaughterhouse environment.  相似文献   

15.
The potentiality of using a luminescent Escherichia coli strain for the specific detection of tetracycline residues in raw bovine milk was investigated. The sensor cells contain a reporter plasmid carrying the bacterial luciferase operon of Photorhabdus luminescens under the control of the tetracycline responsive control region from transposon Tn10. Incubation of the cells with the sample containing tetracyclines increases the light emission of the sensor cells. The most sensitive tetracycline detection was achieved in 120 min and by using CDTA as a chelating agent in the assay. Heat-treatment of milk before the assay decreased the variations in background luminescence signals and in tetracycline-induced luminescence between different milk samples. The detection limits for tetracycline, oxytetracycline, chlortetracycline, doxycycline, methacycline, demeclocycline, and minocycline were between 2 and 35 ng/mL. Nontetracycline antibiotics did not significantly interfere with the detection of tetracyclines.  相似文献   

16.
A rapid analytical method for determining chlorinated pesticide residues in milk was developed. Thirteen pesticides were almost completely extracted. Ten mL samples of fortified milk were extracted 3 times with 20 mL portions of n-hexane as follows: (A) in the absence of water-soluble solvent; in the presence of (B) 1 mL acetonitrile; (C) 3 mL acetonitrile; (D) 5 mL acetonitrile; (E) 5 mL ethanol; (F) 5 mL acetonitrile and 1 mL ethanol. System F produced the highest pesticide recoveries but the lowest fat extraction, thus eliminating the necessity for liquid-liquid partitioning and minimizing Florisil column cleanup. Pesticide recoveries throughout the procedure were 94--103%. It was noticed, however, that the fat in high fat-containing raw milk is more readily extracted than that in commercial milk.  相似文献   

17.
A recently developed confirmatory LC-MS method has been applied to the quantification of five major beta-lactam antibiotics in suspect raw bovine milk samples that gave a positive response with receptor-based (BetaStar) and rapid microbial inhibitory screen tests (Delvotest SP). In total, 18 presumptive positive raw milk samples were reanalyzed; 16 samples showed traces of antibiotic residues that could be identified and quantified by the LC-MS method, ranging from the limits of confirmation up to 38 microg/kg. Of the positive samples, only five (approximately 30%) were found to be violative of EU maximum residue limits. The most frequently detected antibiotic residues were cloxacillin and penicillin G, the former often in combination with amoxicillin or ampicillin. This study compares the results obtained by the three methods on identical samples and addresses how these relate to certain criteria such as sensitivity and selectivity. Furthermore, the limitations of the LC-MS method and the potential impact of the presence of frequently more than one residue in the same milk sample on the response of the rapid test methods are discussed.  相似文献   

18.
Nitroxynil is an anthelmintic used in the treatment of liver fluke. In this study, six dairy cows were treated during lactation with Trodax, a 34% solution containing nitroxynil as its N-ethylglucamine salt, indicated for the treatment of fascioliasis in cattle and sheep. Samples were collected twice daily for 16 days and later at weekly intervals up to 58 days post-treatment. Nitroxynil residues were extracted from milk samples using acetonitrile; magnesium sulfate and sodium chloride were added to induce liquid-liquid partitioning and purified by dispersive solid phase extraction for clean-up. Nitroxynil was determined by ultra performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) in negative ionization mode. The limit of detection (CCα) of the method is 0.24 μg/kg. Maximum concentration of nitroxynil in the samples was in the range of 688-1358 μg/kg, with levels persisting for 58 days in four of the six lactating cows. Incurred nitroxynil samples were treated with sulfatase and β-glucuronidase from Helix pomatia ; the results indicated the presence of glucuronide conjugates in samples at early withdrawal times. At later withdrawal times the concentration of free nitroxynil was lower than the concentration in the control samples, indicating potential degradation during enzymatic treatment.  相似文献   

19.
A rapid immunochromatographic lateral-flow test strip was developed in the competitive reaction format for the detection of sulfonamides in eggs and chicken muscle. A monoclonal antibody against the common structure of sulfonamides was conjugated to colloidal gold particles as the detection reagent and an N-sulfanilyl-4-aminobenzoic acid (SUL)-bovine serum albumin (BSA) conjugate was immobilized to a nitrocellulose membrane as the capture reagent to prepare the test strip. With this method, it required only 15 min to accomplish the semiquantitative or quantitative detection of sulfonamides. The sensitivity to sulfonamides (sulfamonomethoxine, sulfamethoxydiazine, sulfadimethoxine, and sulfadiazine) was at least 10 ng/mL, as determined with an optical density scanner. By eye measurement, the sensitivity was 20 ng/mL for sulfamonomethoxine, sulfamethoxydiazine, and sulfadimethoxine and 40 ng/mL for sulfadiazine. On the basis of a sulfamonomethoxine standard curve, recoveries were from 89.5 to 95.6% for sulfamonomethoxine, from 89.5 to 95.1% for sulfamethoxydiazine, from 85.0 to 95.6% for sulfadimethoxine, and from 44.8 to 60.9% for sulfadiazine in egg and chicken muscle samples. A parallel analysis of 27 egg samples and 28 chicken muscle samples from the animal experiment showed that the differences between test strips and high-performance liquid chromatography (HPLC) were from 0.8 to 11.2% for egg samples and from 2.2 to 34% for chicken muscle samples for the quantitative detection, and the agreement rates between test strips and HPLC were 100%, based on the maximum allowed residue level of sulfadiazine (100 ng/g) established by the European Union and China. In conclusion, the method is rapid and accurate for the detection of sulfonamides in eggs and chicken muscles.  相似文献   

20.
A rapid confirmatory method for monitoring chloramphenicol (CAP) residues in honey, whole milk, and eggs is presented. This method is based on the polymer monolith microextraction (PMME) technique and high-performance liquid chromatography (HPLC)-electrospray ionization mass spectrometry (MS). A poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was selected as the extraction medium. To obtain optimum extraction efficiency, several parameters related to PMME were investigated. After dissolution in 20 mM phosphate solution at pH 4.0 and centrifugation, honey, eggs, or milk samples were directly passed through the extraction tube. The LC-MS instrument was equipped with an electrospray ion source and a single quadrupole. The eluates were analyzed by LC-MS in the negative-ion mode and by monitoring a pair of isotopic ions for the target compound. The in-source collision-induced dissociation process produced confirmatory ions. The recoveries of CAP from real samples spiked at 0.1-10 ng/g (honey), 0.2-10 ng/mL (milk), and 0.2-10 ng/g (egg) were in the range of 85-102%, with relative standard deviations ranging between 2.1% and 8.9%. The limits of detection (S/N = 3) were 0.02 ng/g, 0.04 ng/mL, and 0.04 ng/g in honey, milk, and eggs, respectively. The proposed method was proved to be robust in monitoring CAP residue in honey, milk, and eggs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号