首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectiveTo design and construct an affordable simulator of the cat larynx for training intubation maneuvers and to share the designs for its fabrication.Study designResearch and development study.AnimalsA domestic cat.MethodsThe cadaver of a cat, dead by natural causes, was frozen in sternal recumbency with the neck extended and the mouth wide open. A computed tomography image was acquired and used to construct a digital three-dimensional (3D) model of the pharynx and trachea. A digitally adapted model was 3D-printed and used to generate a silicone model of these structures, which was placed within a wooden container. The quality of the simulator was assessed by 46 veterinary anesthesiologists and veterinarians with experience in tracheal intubation maneuvers, and their opinions were obtained through an anonymous questionnaire.ResultsSeveral preliminary prototypes were assessed regarding stability, texture and cost. Finally, a silicone model of a cat larynx (LaryngoCUBE) was produced and encased in a wooden container. Results from the questionnaire showed high scores regarding anatomy, tissue texture and intubation maneuver realism, compared with the real procedure.Conclusionsand clinical relevance Use of LaryngoCUBE as a training tool may improve the skills of students and reduce the use of animals for teaching endotracheal intubation. Blueprints and computational models are provided online so that the simulator can be fully reproduced.  相似文献   

2.
Objective To evaluate the endotracheal tube cuff pressure achieved by four different inflation methods. Study design Prospective clinical study. Animals Eighty client owned dogs. Methods After anaesthesia induction, endotracheal intubation was performed using plastic or silicone tubes. A clinician unaware of tube type inflated the cuff by simple digital palpation (method A), thereafter the cuff was deflated and inflated again by a second clinician who tried to reproduce a previously learned cuff pressure of between 19 and 24 mmHg (method B). During method C the cuff was inflated to the minimum occlusive volume at an airway pressure of 20 cm H2O, and in method D the cuff was incrementally deflated until an audible air leak could be heard from the oral cavity at an airway pressure of 25 cm H2O. For all the methods, an operator recorded the actual cuff pressure obtained using a manometer. Heart rate, respiratory rate and mean arterial pressure were monitored throughout the procedure. Results The mean inflation pressure for plastic tubes was 56 ± 28 mmHg for method A, 20 ± 9 mmHg for method B, 35 ± 32 mmHg for method C and 46 ± 39 mmHg for method D. Pressures using silicone tubes were significantly higher than for plastic tubes, the mean registered pressures being 79 ± 39, 33 ± 16, 77 ± 50 and 92 ± 56 mmHg for methods A, B, C and D. Conclusions and Clinical Relevance None of the methods evaluated in this study can be considered effective for inflating the endotracheal tube cuff to within the optimal range when using silicone tubes. Direct measurement of the cuff pressure with a manometer is therefore recommended.  相似文献   

3.
4.
OBJECTIVE: To compare the doses of propofol required for insertion of the laryngeal mask airway (LMA) with those for endotracheal intubation in sedated dogs. STUDY DESIGN: Randomized prospective clinical study. Animals Sixty healthy dogs aged 0.33-8.5 (3.0 +/- 2.3, mean +/- SD) years, weighing 2.2-59.0 (23.4 +/- 13.6, mean +/- SD) kg, presented for elective surgery requiring inhalation anaesthesia. METHODS: Animals were randomly assigned to receive either a LMA or an endotracheal tube. Pre-anaesthetic medication was intravenous (IV) glycopyrrolate (0.01 mg kg(-1)) medetomidine (10 microg kg(-1)) and butorphanol (0.2 mg kg(-1)). Repeated IV propofol injections (1 mg kg(-1) in 30 seconds) were given until LMA insertion or endotracheal intubation was achieved, when the presence or absence of laryngospasm, the respiratory rate (fr) and the total dose of propofol used were recorded. RESULTS: The total propofol dose (mean +/- SD) required for LMA insertion (0.53 +/- 0.51 mg kg(-1)) was significantly lower than for endotracheal intubation (1.43 +/- 0.57 mg kg(-1)). The LMA could be inserted without propofol in 47% of dogs; the remainder needed a single 1 mg kg(-1) bolus (n = 30). Endotracheal intubation was possible without propofol in 3.3% of the dogs, 47% needed one bolus and 50% required two injections (n = 30). The f(r) (mean +/- SD) was 18 +/- 6 and 15 +/- 7 minute(-1) after LMA insertion and intubation, respectively. CONCLUSION AND CLINICAL RELEVANCE: Laryngeal mask airway insertion requires less propofol than endotracheal intubation in sedated dogs therefore propofol-induced cardiorespiratory depression is likely to be less severe. The LMA is well tolerated and offers a less invasive means of securing the upper airway.  相似文献   

5.
ObjectiveTo assess the effects of intravenous (IV) fentanyl on cough reflex and quality of endotracheal intubation (ETI) in cats.Study designRandomized, blinded, negative controlled clinical trial.AnimalsA total of 30 client-owned cats undergoing general anaesthesia for diagnostic or surgical procedures.MethodsCats were sedated with dexmedetomidine (2 μg kg–1 IV), and 5 minutes later either fentanyl (3 μg kg–1, group F) or saline (group C) was administered IV. After alfaxalone (1.5 mg kg–1 IV) administration and 2% lidocaine application to the larynx, ETI was attempted. If unsuccessful, alfaxalone (1 mg kg–1 IV) was administered and ETI re-attempted. This process was repeated until successful ETI. Sedation scores, total number of ETI attempts, cough reflex, laryngeal response and quality of ETI were scored. Postinduction apnoea was recorded. Heart rate (HR) was continuously recorded and oscillometric arterial blood pressure (ABP) was measured every minute. Changes (Δ) in HR and ABP between pre-intubation and intubation were calculated. Groups were compared using univariate analysis. Statistical significance was set as p < 0.05.ResultsThe median and 95% confidence interval of alfaxalone dose was 1.5 (1.5–1.5) and 2.5 (1.5–2.5) mg kg–1 in groups F and C, respectively (p = 0.001). The cough reflex was 2.10 (1.10–4.41) times more likely to occur in group C. The overall quality of ETI was superior in group F (p = 0.001), with lower laryngeal response to ETI (p < 0.0001) and ETI attempts (p = 0.045). No differences in HR, ABP and postinduction apnoea were found.Conclusions and clinical relevanceIn cats sedated with dexmedetomidine, fentanyl could be considered to reduce the alfaxalone induction dose, cough reflex and laryngeal response to ETI and to improve the overall quality of ETI.  相似文献   

6.
7.
8.
Endotracheal intubation is commonly performed in horses undergoing general anaesthesia to avoid fluid aspiration and provide mechanical ventilation and inhalational anaesthetic agents. Secondary laryngeal and tracheal trauma following intubation is not rare. This case report describes the successful treatment of a horse with laryngeal and tracheal trauma secondary to intubation during myelography. Based on other clinical reports and clinical experience, movement of the endotracheal tube during myelography was considered the most likely cause of the damage. This case underscores the importance of monitoring horses for development of respiratory signs after general anaesthesia for computerised tomography and myelography.  相似文献   

9.
10.
OBJECTIVE: To compare the cardiorespiratory effects and incidence of gastroesophageal reflux with the use of a laryngeal mask airway (LMA) or endotracheal tube (ET) in anesthetized cats during spontaneous (SV) or controlled ventilation (CV). STUDY DESIGN: Prospective randomized experimental trial. ANIMALS: Thirty-two adult crossbred cats, weighing 2.7 +/- 0.4 kg. METHODS: The cats were sedated with intramuscular (IM) methotrimeprazine (0.5 mg kg(-1)) and buprenorphine (0.005 mg kg(-1)), followed 30 minutes later by induction of anesthesia with intravenous (IV) thiopental (12.5-20 mg kg(-1)). An ET was used in 16 cats and an LMA in the remaining 16 animals. Anesthesia was maintained with 0.5 minimum alveolar concentration (0.6%) of halothane in oxygen using a Mapleson D breathing system. Cats in both groups were further divided into two equal groups (n = 8), undergoing either SV or CV. Neuromuscular blockade with pancuronium (0.06 mg kg(-1)) was used to facilitate CV. Heart and respiratory rates, direct arterial blood pressure, capnometry (PE'CO2) and arterial blood gases were measured. Gastric reflux and possible aspiration was investigated by intragastric administration of 5 mL of radiographic contrast immediately after induction of anesthesia. Cervical and thoracic radiographs were taken at the end of anesthesia. Data were analyzed using anova followed by Student-Newman-Keuls, Kruskal-Wallis or Friedman test where appropriate. RESULTS: Values for PaCO2 and PE'CO2 were higher in spontaneously breathing cats with the LMA when compared with other groups. Values of PaO2 and hemoglobin oxygen saturation did not differ between groups. Gastroesophageal reflux occurred in four of eight and two of eight cats undergoing CV with ET or LMA, respectively. There was no tracheal or pulmonary aspiration in any cases. CONCLUSIONS AND CLINICAL RELEVANCE: The use of an LMA may be used as an alternative to endotracheal intubation in anesthetized cats. Although aspiration was not observed, gastric reflux may occur in mechanically ventilated animals.  相似文献   

11.
ObjectiveTo compare blind and endoscopic-guided techniques for orotracheal intubation in rabbits and the number of intubation attempts with laryngeal/tracheal damage.Study designProspective, randomized experimental study.AnimalsA total of 24 healthy, intact female New Zealand White rabbits, weighing 2.2 ± 0.2 kg (mean ± standard deviation).MethodsRabbits were randomly assigned to blind (group B) or endoscopic-guided (group E) orotracheal intubation with a 2.0 mm internal diameter uncuffed tube. Intramuscular (IM) alfaxalone (7 mg kg–1), hydromorphone (0.1 mg kg–1) and dexmedetomidine (0.005 mg kg–1) were administered, and additional IM alfaxalone (3–5 mg kg–1) and dexmedetomidine (0.025 mg kg–1) were administered to rabbits with strong jaw tone. An intubation attempt was defined as the advancement of the endotracheal tube from the incisors to the laryngeal entrance. Tracheal intubation was confirmed via capnography and anesthesia was maintained with isoflurane for 2 hours. Following euthanasia, laryngeal and tracheal tissues were submitted for histopathology. Quality of anesthesia for orotracheal intubation, intubation procedure and tissue damage were numerically scored. Data were analyzed using Poisson regression, Spearman’s correlation, t test, mixed anova, Mann–Whitney U test, Friedman and Chi square tests as appropriate.ResultsMedian (range) intubation attempts were 2 (1–8) and 1 (1–3) for groups B and E, respectively. More rabbits in group E (91.6%) required additional alfaxalone and dexmedetomidine than in group B (16.7%). Median (range) cumulative histopathology scores were 6 (3–10) and 6 (2–9) for groups B and E, respectively. Scores were highest in the cranial trachea, but there was no difference between groups and no correlation between laryngeal/tracheal damage and the number of intubation attempts.Conclusions and clinical relevanceBoth orotracheal intubation techniques were associated with laryngeal/tracheal damage. Although blind orotracheal intubation was associated with a higher number of attempts, the tissue damage was similar between groups.  相似文献   

12.
13.
This case report describes the death of a yearling Thoroughbred colt due to segmental severe necrotising tracheitis with stenosis of the tracheal lumen, 19 days after endotracheal intubation for elective endoscopic surgery. The stenosis of the trachea leading to asphyxiation was caused by an inflammatory process accompanied by massive accumulation of necrotic material, fibrinous inflammatory exudate, oedema and granulation tissue. The cause of this inflammation was likely to be a bacterial infection secondary to traumatic damage of the tracheal mucosa. Given the clinical history and location of the lesion, the endotracheal tube used for general anaesthesia was hypothesised to be responsible for this damage. Delayed tracheal necrosis as a fatal complication of endotracheal intubation has not previously been described in the horse and should be considered as a potential catastrophic consequence following relatively innocuous clinical signs.  相似文献   

14.
15.
OBJECTIVE: To compare the ease of placement and ventilatory parameters of a laryngeal mask airway (LMA) with an endotracheal tube (ETT) in anesthetized swine during positive-pressure ventilation (PPV). STUDY DESIGN: Prospective, randomized, experimental trial. ANIMALS: Nine young domestic swine, weighing between 40 and 49 kg (mean 45.1 kg), being used for a separate terminal surgical study. METHODS: The pigs were immobilized with tiletamine/zolazepam, 2.7-3.6 mg kg(-1), intramuscularly, followed by isoflurane in oxygen delivered by facemask. The lungs were mechanically ventilated through an ETT or an LMA, in random order, during the anesthetic period. Positive-pressure ventilation was adjusted to maintain end-tidal CO2 (Pe'CO2) between 35 and 45 mmHg, with peak inspiratory pressure (P(insp)) of 15-23 cmH2O. Buprenorphine, 0.3 mg intramuscularly, was given to each pig after instrumentation. Isoflurane vaporizer settings were adjusted to maintain a surgical plane of anesthesia. Respiratory rate (RR), tidal volume (V(T)), minute volume (V(E)), and Pe'CO2 were measured and recorded at 5-minute intervals. After the collection of 1 hour of data, the alternate airway was placed. Swine were given at least 30 minutes to stabilize and another hour of data were recorded. At the time of airway placement, the ease of placement was assessed based on time and the number of personnel required. Data were analyzed using paired Student's t-test or Wilcoxon signed rank test where appropriate. RESULTS: Laryngeal mask airways were significantly easier to place than ETT. Values for V(T) and V(E) were not significantly different between treatments. Peak inspiratory pressures were higher in ETT-ventilated swine. CONCLUSIONS AND CLINICAL RELEVANCE: An LMA may be used as an alternative to an ETT in mechanically-ventilated anesthetized swine. Use of an LMA may reduce time and personnel required for placement of an airway.  相似文献   

16.
OBJECTIVE: To investigate the effect of endotracheal tube cuff inflation pressure on the occurrence of liquid aspiration and tracheal wall damage. STUDY DESIGN: Prospective, randomized experimental study. ANIMALS: Ten healthy horses, weighing 535 +/- 55 kg. METHODS: Horses were anesthetized, orotracheally intubated, placed in dorsal recumbency, and maintained on isoflurane in oxygen with controlled ventilation for 175 +/- 15 minutes. The horses were randomly assigned to an endotracheal cuff pressure of 80-100 or 120 cm H2O. The cuff pressure was continuously monitored and maintained at a constant pressure. Methylene blue in saline was instilled proximal to the cuff. After euthanasia, the trachea was opened distal to the endotracheal tube tip to check for evidence of dye leaking past the cuff. The cervical trachea was then resected and opened longitudinally for gross and histologic examinations. RESULTS: No blue staining was found distal to the cuff in any horse. Visual examination of the tracheal mucosa revealed hyperemic and hemorrhagic lesions at the site of the cuff contact. Histologic changes included epithelium attenuation or erosion, submucosal neutrophilic infiltration, and submucosal hemorrhages. Lesions were absent or less extensive in the lower cuff pressure group as compared to the high cuff pressure group. CONCLUSIONS: The endotracheal tube cuff produced a seal sufficient to prevent leakage in both groups. Tracheal wall damage was more severe and occurred more frequently in the higher cuff pressure group. CLINICAL RELEVANCE: Tracheal mucosal damage induced by cuff inflation is pressure-dependent. Cuff pressure monitoring is recommended.  相似文献   

17.

Objective

The effect of user experience and inflation technique on endotracheal tube cuff pressure using a feline airway simulator.

Study design

Prospective, experimental clinical study.

Methods

Participants included veterinary students at the beginning (group S1) and end (group S2) of their 2-week anaesthesia rotation and veterinary anaesthetists (group A). The feline airway simulator was designed to simulate an average size feline trachea, intubated with a 4.5 mm low-pressure, high-volume cuffed endotracheal tube, connected to a Bain breathing system with oxygen flow of 2 L minute?1. Participants inflated the on-endotracheal tube cuff by pilot balloon palpation and by instilling the minimum occlusive volume (MOV) required for loss of airway leaks during manual ventilation. Intracuff pressures were measured by manometers obscured to participants and ideally were 20–30 cm H2O. Student t, Fisher exact, and Chi-squared tests were used where appropriate to analyse data (p < 0.05).

Results

Participants were 12 students and eight anaesthetists. Measured intracuff pressures for palpation and MOV, respectively, were 19 ± 12 and 29 ± 19 cm H2O for group S1, 10 ± 5 and 20 ± 11 cm H2O for group S2 and 13 ± 6 and 29 ± 18 cm H2O for group A. All groups performed poorly at achieving intracuff pressures within the ideal range. There was no significant difference in intracuff pressures between techniques. Students administered lower (p = 0.02) intracuff pressures using palpation after their training.

Conclusions and clinical relevance

When using palpation and MOV for cuff inflation operators rarely achieved optimal intracuff pressures. Experience had no effect on this skill and, as such, a cuff manometer is recommended.  相似文献   

18.
A peri-carinal tracheal laceration was produced in a 11-year-old cat during tracheal intubation. Before reconstructive surgery began, the leak was bypassed with an endobronchial tube positioned using endoscopy and direct vision. However, single-lung ventilation could not be sustained because the tube became dislodged and could not be repositioned. Consequently, surgery was completed with periods of intermittent apnoea interspersed with manually controlled hyperventilation. Cardiovascular variables were stable during anaesthesia and no signs of hypoxia were detected. The difficulties in maintaining endobronchial tube position resulted from the animal's small size relative to the dimensions of the endotracheal tube.  相似文献   

19.
ObjectiveTo compare ultrasonography with computed tomography (CT) for assessment of tracheal diameter as a feasibility study for endotracheal tube selection.Study designProspective study.AnimalsA total of nine Beagle dogs with a median (interquartile range) weight of 7.4 (7.2–7.7) kg.MethodsTracheal diameter measurements were obtained at two locations: 1 cm proximal to caudal border of the cricoid cartilage (sublaryngeal; SL) and dorsal to above cranial border of the manubrium (thoracic inlet; TI). For CT, dogs were anesthetized with propofol and sevoflurane, in sternal recumbency, and measurements obtained after controlled ventilation–induced apnea and the endotracheal tube cuff was deflated. Transverse diameter, right and left 45° oblique diameters were measured. For ultrasonography, unsedated dogs were standing with slight neck extension, and images obtained in ventrodorsal, 45° right and left oblique ways after expiration. Diameters between the tracheal lumen mucosal borders were measured. The degree of agreement between the tracheal diameters measured at SL and TI locations with CT (TDCT-SL and TDCT-TI) and ultrasonography (TDUS-SL and TDUS-TI) was verified using the Bland-Altman method.ResultsThe agreement between the measurements obtained with CT and ultrasonography was revealed by Bland-Altman analyses, although ultrasonography tended to slightly underestimate the tracheal diameter.Conclusions and clinical relevanceUltrasonography can be applied for tracheal diameter measurement. Although further studies are required, an endotracheal tube selection method, using ultrasonography, could be proposed.  相似文献   

20.
Objective  To compare the incidence of gastro-oesophageal reflux (GOR) during anaesthesia in the kitten when using a laryngeal mask airway (LMA) or an endotracheal tube (ET).
Study design  Prospective randomized cross-over experimental study.
Animals  Forty Domestic Short Hair laboratory cats, 19 females and 21 males, aged 12–15 weeks and weighing 0.57–1.73 kg (mean 1.13 ± SD 0.26).
Methods  Kittens were anaesthetized twice, once using the LMA and once the ET. Following induction of anaesthesia with isoflurane in an anaesthetic chamber and intubation of the trachea with the ET or placement of the LMA, a pH-electrode was introduced into the lower oesophagus. Monitoring of the oesophageal pH was performed for 45 minutes while anaesthesia was maintained with isoflurane. At the end of the experiment, gastric pH was measured. Kittens that had GOR during the experiment were treated with sucralfate, cisapride and ranitidine for 15 days.
Results  Oesophageal pH was 6.51 ± 0.76 and gastric pH was 1.54 ± 0.59. GOR was observed in nine kittens when the ET was used, and in 20 kittens when the LMA was used, the difference being significant ( p  =   0.013). The refluxate nearly always was acidic, being alkaline in only one kitten. Most of the GOR episodes occurred shortly after induction of anaesthesia and the oesophageal pH remained below 4.0 until the end of the experiment. No regurgitation was observed.
Conclusions and clinical relevance  The use of the LMA is associated with an increased incidence of GOR during anaesthesia in the kitten, which is not detected by observation. That this may have occurred should be considered if the kitten demonstrates signs of oesophagitis in the postoperative period.  相似文献   