首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Contamination of food products with pepsin resistant allergens is generally believed to be a serious threat to patients with severe food allergy. A sandwich type enzyme-linked immunosorbent assay (ELISA) was developed to measure pepsin resistant hazelnut protein in food products. Capturing and detecting rabbit antibodies were raised against pepsin-digested hazelnut and untreated hazelnut protein, respectively. The assay showed a detection limit of 0.7 ng/mL hazelnut protein or <1 microg hazelnut in 1 g food matrix and a maximum of 0.034% cross-reactivity (peanut). Chocolate samples spiked with 0.5-100 microg hazelnut/g chocolate showed a mean recovery of 97.3%. In 9/12 food products labeled "may contain nuts", hazelnut was detected between 1.2 and 417 microg hazelnut/g food. It can be concluded that the application of antibodies directed to pepsin-digested food extracts in ELISA can facilitate specific detection of stable proteins that have the highest potential of inducing severe food anaphylaxis.  相似文献   

2.
An indirect competitive ELISA was developed allowing the detection of hidden peanut protein residues down to 2 ppm (micorgrams per gram) in various foods. The high-titer, peanut-specific polyclonal antiserum used recognized potentially allergenic proteins in both native and roasted peanuts. In the absence of a food matrix, extractable protein from roasted peanuts was detected at 104 +/- 13%. From various food items, peanut protein at > or =13 ppm was recovered between 84 and 126%, and at 2 ppm of peanut protein recovery was 143 +/- 6%. Intra- and interassay precision was <15%. In 5 of 17 commercial food products without declaration of peanut components, between 2 and 18 ppm of peanut protein was detected. This is the first assay based on commercially available reactants that allows the reliable determination of trace amounts of hidden peanut allergens in a variety of complex food matrices.  相似文献   

3.
Hidden allergens in food products are, especially for peanut-allergic consumers, a serious problem because even low amounts (approximately 200 microg) of peanut can elicit allergic reactions. Undeclared peanut traces can be found in processed food products, because contaminations with peanut during production processes are frequent. To minimize the risk of such cross-contaminations, it is necessary to develop sensitive analytical methods for the detection of hidden allergens in foods. For this approach we developed two peanut-specific assays based on the detection of peanut protein by specific antibodies (sandwich ELISA) and by the detection of peanut-specific DNA (part of the coding region of Ara h 2) by a real-time PCR. Both tests did not show any cross-reactivity with 22 common food ingredients (cereals, nuts, legumes), and the limit of detection is <10 ppm peanut in processed foods. Thirty-three random samples of food products were tested for the presence of peanut to compare both assay types with each other and to evaluate the percentage of foods on the German market that are contaminated with peanut traces. We found that four products (13.3%) without peanut in the list of ingredients contained peanut protein in a range from 1 to 74 ppm peanut protein and that the results of both tests correlated well. The real-time PCR was able to detect one more positive sample than the sandwich ELISA. In conclusion, both assays are sensitive and specific tools for the detection of hidden allergens in processed foods.  相似文献   

4.
A hazelnut-specific sandwich-type ELISA based on polyclonal antisera was developed for detection of hidden hazelnut protein residues in complex food matrixes. In the absence of a food matrix, extractable protein from different native and toasted hazelnuts was detected at rates of 94 +/- 13 and 96 +/- 7% applying standards prepared from native and toasted hazelnuts, respectively. From complex food matrixes, 0.001-10% of hazelnut was recovered between 67 and 132%, in average by 106 +/- 17%. Depending on the food matrix, hazelnut protein could be detected down to the ppb (ng/g) level. Intraassay precision was <6% for hazelnut >/= 0.001% and interassay precision was <15% for hazelnut >/= 0.01%. In 12 of 28 commercial food products without labeling or declaration of hazelnut components, between 2 and 421 ppm of hazelnut protein was detected, demonstrating a remarkable presence of potentially allergenic hazelnut protein "hidden" in commercial food products.  相似文献   

5.
Allergen detection is of increasing interest for food labeling purposes. A comparative study with a commercial hazelnut-specific PCR-ELISA and a sandwich-type ELISA detecting hazelnut protein was performed to investigate to what extent immunochemical and DNA-based techniques would correlate in the detection of trace amounts of potentially allergenic hazelnut residues. Both methods were highly sensitive and allowed the detection of even <10 ppm of hazelnut in complex food matrixes. The protein-ELISA was highly specific for hazelnut. However, some foods could lead to false-positive results at the 10 ppm level. The PCR-ELISA did not show any cross-reactions with non-hazelnut foods, thus reducing the probability of having false positives at the trace level. Forty-one commercial food products with and without hazelnut components on their labels were analyzed for the presence of hazelnut. Of the 27 products in which hazelnut components were detected, two samples were not identified by the protein-ELISA, and only one sample, namely one white chocolate having <1 ppm of hazelnut protein, was not detected by PCR-ELISA. The good correlation of the results of PCR-ELISA and protein-ELISA suggested that both PCR-based and immunochemical techniques are suitable for reliable detection of potentially allergenic hazelnut residues in foods at the trace level.  相似文献   

6.
Detection of peptides from the peanut allergen Ara h 1 by liquid chromatography-mass spectrometry (LC-MS) was used to identify and estimate total peanut protein levels in dark chocolate. A comparison of enzymatic digestion subsequent to and following extraction of Ara h 1 from the food matrix revealed better limits of detection (LOD) for the pre-extraction digestion (20 ppm) than for the postextraction digestion (50 ppm). Evaluation of LC-MS instruments and scan modes showed the LOD could be further reduced to 10 ppm via a triple-quadrupole and multiple-reaction monitoring. Improvements in extraction techniques combined with an increase in the amount of chocolate extracted (1 g) improved the LOD to 2 ppm of peanut protein. This method provides an unambiguous means of confirming the presence of the peanut protein in foods using peptide markers from a major allergen, Ara h 1, and can easily be modified to detect other food allergens.  相似文献   

7.
Hazelnuts (Corylus avellana) are used widely in the food industry, especially in confectionery, where they are used raw, roasted, or in a processed formulation (e.g., praline paste and hazelnut oil). Hazelnuts contain multiple allergenic proteins, which can induce an allergic reaction associated with symptoms ranging from mild irritation to life-threatening anaphylactic shock. To date, immunochemical (e.g., ELISA or dipstick) and PCR-based analyses are the only methods available that can be applied as routine tests. The aim of this study is to make a comparative evaluation of the effectiveness of ELISA and real-time PCR in detecting and correctly quantifying hazelnut in food model systems. To this end, the performances of two commercial ELISAs were compared to those of two commercial and one in-house-developed real-time PCR assays. The results showed that although ELISA seemed to be more sensitive compared to real-time PCR, both detection techniques suffered from matrix effects and lacked robustness with regard to food processing. As these impacts were highly variable among the different evaluated assays (both ELISA and real-time PCR), no firm conclusion can be made as to which technique is suited best to detect hazelnut in (processed) food products. In this regard, the current lack of appropriate DNA calibrators to quantify an allergenic ingredient by means of real-time PCR is highlighted.  相似文献   

8.
A gas chromatographic/mass spectrometric (GC/MS) method for determining daminozide in high protein products has been developed. Daminozide is hydrolyzed in the presence of a strong base to form unsymmetrical dimethylhydrazine (UDMH) which is then distilled from the food matrix. A stable derivative is formed by reacting UDMH with salicyladehyde to form salicyaldehyde dimethylhydrazone. This derivative is separated and quantitated by GC/MS using selected ion monitoring (SIM) of key ions in the fragmentation pattern: m/z 164 (molecular ion of hydrazone) and m/z 120 (C7H6ON). An internal standard, 4-nitroanisole, is monitored at m/z 153 (molecular ion) and m/z 123 (C6H5O2N). The limit of detection is 0.01 ppm daminozide in a 50 g sample; however, because of variation at low levels, the limit of quantitation is 0.1 ppm. Recoveries are 90% or greater from peanuts and peanut butter spiked at the 0.1-2 ppm level. Reproducibility of the method depends on the food matrix and is 26% RSD in the worst case. Data are compared for the GC/MS method and the official EPA colorimetric procedure. Results showed a high bias in the colorimetric method, especially when roasted peanut products were analyzed.  相似文献   

9.
Determination of sulfite in food by flow injection analysis   总被引:3,自引:0,他引:3  
A method is described for the determination of sulfite levels in food products by flow injection analysis (FIA). The method is based on the decolorization of malachite green by SO2, which is isolated from the flowing sample stream by means of a gas diffusion cell. The FIA method has a detection limit in food sample extracts of 0.1 ppm SO2 (3 times peak height of blank), which corresponds to 1-10 ppm SO2 in a food product, depending on the extraction procedure used. At the 5 ppm SO2 level in a food extract, the precision of replicate injections is +/- 1-2%. The method was tested on a variety of both sulfite-treated and untreated food products and the results compared favorably with those obtained by the Monier-Williams, colorimetric (pararosaniline), and enzymatic (sulfite oxidase) methods. The average differences from the FIA results were 19, 11, and 12%, respectively, for those samples (n = 12) above 50 ppm SO2. At lower levels the results were somewhat more erratic due to inaccuracies of the various methods at low concentrations.  相似文献   

10.
Hazelnut is one of the most commonly consumed tree nuts, being largely used by the food industry in a wide variety of processed foods. However, it is a source of allergens capable of inducing mild to severe allergic reactions in sensitized individuals. Hence, the development of highly sensitive methodologies for hazelnut traceability is essential. In this work, we developed a novel technique for hazelnut detection based on a single-tube nested real-time PCR system. The system presents high specificity and sensitivity, enabling a relative limit of detection of 50 mg/kg of hazelnut in wheat material and an absolute limit of detection of 0.5 pg of hazelnut DNA (1 DNA copy). Its application to processed food samples was successfully achieved, detecting trace amounts of hazelnut in chocolate down to 60 mg/kg. These results highlight the adequacy of the technique for the specific detection and semiquantitation of hazelnut as potential hidden allergens in foods.  相似文献   

11.
Methoxyfenozide [3-methoxy-2-methylbenzoic acid 2-(3,5-dimethylbenzoyl)-2-(1,1-dimethylethyl) hydrazide; RH-2485], in the formulation of INTREPID, was applied to various crops. Analysis of methoxyfenozide was accomplished by utilizing liquid-liquid extraction and partitioning, followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Method validations for fruits, vegetables, and mint are reported. Methoxyfenozide mean recoveries ranged from 72 to 129% over three levels of fortification. The overall average of mean recoveries is 97 +/- 10%. The limit of quantitation for fruits, artichoke, cucumber, squash, and refined sugar was 0.010 ppm, with a detection limit of 0.005 ppm. For all other crops, the limit of quantitation was 0.050 ppm, with a detection limit of 0.025 ppm. No residues were found greater than the limit of quantitation in control samples. Residues above the limit of quantitation were found in all matrices except refined sugar. Foliage (bean, beet, pea, and radish) had greater residue levels of methoxyfenozide residue than their corresponding roots or pods. Other crop matrices contained <1.0 ppm of methoxyfenozide except artichoke, which had a mean of 1.10 ppm.  相似文献   

12.
A modified version of the Conditt and Baumgardner gas chromatographic/mass spectroscopic (GC/MS) method for determination of daminozide in peanut butter and raw peanuts is described. Daminozide in the food product is hydrolyzed to unsymmetrical dimethylhydrazine (UDMH) by sodium hydroxide digestion. The generated UDMH is distilled from the food matrix and captured by reaction with salicylaldehyde in a condensation trap. Resulting high pH distillates generated by peanuts and peanut products are adjusted back to a pH of 5-6 through addition of glacial acetic acid. After thermal incubation and extraction into methylene chloride, salicylaldehyde dimethylhydrazone is separated from interferences by capillary GC and quantitated by MS using the selective ion monitoring (SIM) mode. Quantitation of daminozide is based on the ratio of the salicylaldehyde dimethylhydrazone molecular ion (m/z 164) to the molecular ion (m/z 153) of the internal standard, 4-nitroanisole. Confirmation of daminozide identity is determined by relative intensity of the m/z 164 ion to the m/z 120 (C7H4ON) ion. Improved m/z 164 ion intensity and reduction of neighboring interferences due to acetic acid treatment permitted a daminozide detection limit of 0.005 ppm in a 50 g sample and an associated 0.02 ppm limit of quantitation. This modification is specific for high protein samples that generate high pH distillates such as peanuts and peanut products and is not specifically intended for analysis of low protein samples.  相似文献   

13.
Compliance with the European allergen labeling legislation (Directive 2007/68/EC) is only possible when coupled with appropriate methods to detect allergens in food. The aim of the current study was to develop new real-time PCR assays for the detection of hazelnut and soy and evaluate these assays via comparison with commercially available kits. Although the new assays were not as sensitive as the commercial qualitative assays, they proved to be more specific. Moreover, the cross-reactivity study indicated contamination of some of the food products used with either hazelnut or soy, which presents a risk for the allergic consumer. The assays were able to quantify as few as 5-15 genome copies. This unit, used to express analytical results for allergen detection by means of PCR, needs to be converted to a unit expressing the amount of allergenic ingredient in order to be informative. This study emphasizes that the use of real-time PCR for allergen quantification is complicated by the lack of appropriate reference materials for allergens.  相似文献   

14.
A new method is proposed for the determination of the enantiomeric composition of gamma-lactones in different vegetable edible oils (i. e., olive oil, almond oil, hazelnut oil, peanut oil, and walnut oil), and its potential for authenticity control is underlined for a limited number of samples. The method is based on the direct injection (i.e., without requiring a sample pretreatment step) in on-line coupled reversed phase liquid chromatography to gas chromatography (RPLC-GC) using a chiral stationary phase in the GC-step. Different experimental values for both speed of sample introduction into GC and volume of the transferred fraction are considered to improve the recoveries obtained. Relative standard deviations lower than 10% and detection limits ranging from 0.06 to 0.22 mg/L were achieved for the investigated gamma-lactones.  相似文献   

15.
Two direct enzyme-linked immunosorbent assays (ELISAs) have been developed for detection of sulfonamide antibiotic residues in milk samples. One of them is using magnetic nanoparticles (MNP) for target capture/enrichment (Ab-MNP-ELISA), and the second is performed using microtiter plates. Selective polyclonal antibodies, raised against 5-[6-(4-amino-benzenesulfonylamino)-pyridin-3-yl]-2-methyl-pentanoic acid (SA1), used in combination with an enzyme tracer prepared with the same hapten, has allowed us to reach a limit of detection (LOD) lower than 0.5 microg L(-1) for both ELISA formats. Sulfapyridine, sulfamethoxypyridazine, sulfathiazole, and sulfachloropyridazine are detected below the maximum residue limits established by the European Union for these antibiotics in milk (100 microg L(-1)). Matrix effects and accuracy studies performed with full-cream milk and hair extracts indicated a lack of interference from these sample matrices and very good recovery values, especially when using the Ab-MNP format. Milk samples and hair extracts can be measured without any previous treatment. The results demonstrate the high potential of these methods as screening tools for food safety and inspection controls.  相似文献   

16.
A wide variety of enzyme‐linked immunosorbent assays (ELISAs) are commercially available for gluten detection in food, including new formats and assays with antibodies against relevant gluten epitopes. Nevertheless, problems persist to accurately determine the gluten content of products. In this study, the performance of a set of 14 ELISA kits for gluten detection, representative of the current ELISA methods available on the market, was evaluated. These tests were used to determine gluten content in a series of relevant food matrices varying in complexity. Our results show that, currently, there is no single ELISA method that can accurately detect and quantify gluten in all different matrices. This includes the current type I method R5 as recommended by Codex Alimentarius. We conclude that further improvements are urgently needed and recommend focusing on competitive formats, improving extraction methods, and the detection of relevant gluten peptides (in order of priority).  相似文献   

17.
A method using gel permeation and Florisil column chromatographic cleanup techniques is described for determination of residues of nonpolar organohalogen pesticides and pesticide alteration products in vegetable oils and their refinery by-products. Supplemental Florisil separation and alkali cleanup techniques are used to facilitate determinations. Residues are determined with a 63Ni electron capture gas chromatographic detection system used in conjunction with 3 different gas chromatographic columns. Residue identities are confirmed by gas chromatography-mass spectrometry. Recoveries of 7 organohalogen pesticides, ranging from 90 to 103%, were determined by the supplemental Florisil separation technique to augment previously reported recovery data determined for initial GPC and Florisil cleanup steps. Soybean, peanut, and cottonseed deodorizer distillates and crude and refined oil, as well as additional refinery by-products, were analyzed. Nine to 13 organohalogen residues ranging from 0.5 to 6.3 ppm were determined in the 2 soybean deodorizer distillate samples used to develop and test the method. Identities of residues present at greater than or equal to 0.3 ppm were confirmed by gas chromatography-mass spectrometry. An intralaboratory trial of the method provided additional recovery and residue determination data as follows: Recoveries ranging from 102 to 116% were obtained for 4 pesticides added to peanut oil deodorizer distillate. Residues determined in 1 soybean deodorizer distillate sample supported previously obtained data for this sample.  相似文献   

18.
A screening method for aflatoxins was collaboratively tested on 11 different agricultural and food products: white and yellow corn, peanuts, peanut butter, pistachio nuts, peanut meal, cottonseed meal, chicken, pig, and turkey starter rations, and dairy cattle feed. The method involves a rapid extraction and cleanup procedure followed by the detection of total aflatoxins (B1 + B2 + G1 + G2) as a fluorescent band on the Florisil layer of a Velasco-type minicolumn. The results of 32 collaborators from 10 different countries are presented. Samples containing 0, 5, 10, 15, 20, and 25 mug aflatoxins/kg were analyzed. Eighty-four per cent of the negative samples and 89% of the samples containing 10-25 mug total aflatoxins/kg were correctly identified. This method has been adopted as official first action for the detection of aflatoxins in corn, peanuts, peanut butter, peanut meal, cottonseed meal, mixed feeds, and pistachio nuts.  相似文献   

19.
Enzymatic digestion of total protein along with liquid chromatography/tandem mass spectrometry (LC/MS/MS) was used to confirm the presence of a major peanut allergen in food. Several peptides obtained from the enzymatic digestion of the most abundant peanut allergen, Ara h 1, were identified as specific peptide biomarkers for peanut protein. Using ice cream as a model food matrix, a method was developed for the detection of the allergen peptide biomarkers. A key component of the method was the use of molecular mass cutoff filters to enrich the Ara h 1 in the protein extracts. By applying the method to ice cream samples containing various levels of peanut protein, levels as low as 10 mg/kg of Ara h 1 could routinely be detected. This method provides an unambiguous means of confirming the presence of the peanut allergen, Ara h 1, in foods and can easily be modified to detect other food allergens.  相似文献   

20.
The development of a DNA microarray method on a digital versatile disk (DVD) is described for the simultaneous detection of traces of hazelnut ( Corylus avellana L.), peanut ( Arachis hypogaea ), and soybean ( Glycine max ) in foods. After DNA extraction, multiplex PCR was set up using 5'-labeled specific primers for Cor a 1, Ar h 2, and Le genes, respectively. Digoxin-labeled PCR products were detected by hybridization with 5'-biotinylated probes immobilized on a streptavidin-modified DVD surface. The reaction product attenuates the signal intensity of the laser that reached the DVD drive used as detector, correlating well with the amount of amplified sequence. Analytical performances showed a detection limit of 1 μg/g and good assay reproducibility (RSD 8%), suitable for the simultaneous detection of the three targeted allergens. The developed methodology was tested with several commercially available foodstuffs, demonstrating its applicability. The results were in good agreement, in terms of sensitivity and reproducibility, with those obtained with ELISA, PCR-gel agarose electrophoresis, and RT-PCR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号