首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
In veterinary patients, postgastric feeding is indicated for uncontrollable gastric vomiting, gastroparesis, biliary tract disease, pancreatitis, and for patients at increased risk for aspirating secondary to decreased mentation, prolonged recumbency, or an unprotected airway. Postgastric feeding may be implemented via the placement of a jejunal feeding tube. These tubes can be placed surgically (jejunostomy tubes) or with fluoroscopic or endoscopic guidance. This article will focus on methods of jejunal feeding-tube placement, advantages and disadvantages of the methods described, and complications associated with jejunal feeding.  相似文献   

2.
Five male crossbred dogs successfully underwent surgical placement of button enterostomy tubes to evaluate the placement technique, maintenance and complications of these tubes. Surgical placement was quick, technically straightforward and similar to techniques used for other feeding tubes. None of the dogs experienced life-threatening complications during the 10 month follow-up period. One device required replacement as it was removed by the dog before a permanent fistula had formed. Open tubes due to loose safety plugs and focal cellulitis surrounding the exit sites of these tubes were noted in all dogs. The button tube may be a feasible option for long-term nutritional support in patients with pancreatic, hepatobiliary or gastrointestinal conditions.  相似文献   

3.
Objective: The purpose of this study was to determine the effect of timing of analysis, collection tube type and repeated opening of sample tubes on venous PCO2, pH, HCO3, and base excess (BE) results. Design: Prospective experimental study, paired sample analysis. Setting: Veterinary Medical Teaching Hospital. Animals: Twenty dogs. Interventions: Jugular venous blood samples. Measurements and main results: PCO2, pH, HCO3, and BE were determined immediately following collection (control) and at selected times up to 30 minutes after placement in either screw top or vacuum heparin collection tubes. A different set of screw top and vacuum heparin collection tubes were sampled repeatedly over time for up to 15 minutes. In the screw top delayed analysis group, only pH changed significantly at one time point. PCO2 decreased significantly in all other groups and resulted in a significant reciprocal pH change in the vacuum tubes with either delayed single analysis or repeated sampling. HCO3 and BE declined significantly in multi‐sampled vacuum tubes and HCO3 also decreased significantly in multi‐sampled screw top tubes. Conclusions: Analysis of acid–base status is optimally performed on freshly drawn blood. However, when it is anticipated there will be a delay in analysis of samples kept at room temperature, the use of 2.0 mL plastic screw top heparin anticoagulant tubes may result in fewer pre‐analytical errors than 3.5 mL glass vacuum tubes.  相似文献   

4.
Candida krusei was isolated from a gastrostomy tube that failed 175 d after placement in a 13-year-old cat. Fungal colonization of gastrostomy tubes is common in humans and a contributor to tube failure. Veterinarians should be aware of this phenomenon in patients that have long-term indwelling feeding tubes.  相似文献   

5.
The medical records of 39 dogs and 8 cats which had jejunostomy feeding tubes placed using modifications of a previously described surgical technique were retrospectively reviewed. Modifications included the addition of a suture to anchor the feeding tube to the jejunum, the use of a continuous circumferential suture to pexy the jejunum to the abdominal wall, and the placement of a skin suture that penetrated deep into the abdominal wall fascia. All tubes were placed during surgical treatment of a primary intraabdominal disease. Tubes were used for feeding from 1 to 41 days (average 9.7 days). Sixteen patients (34%) developed mild to moderate complications such as chewing at the tube, inadvertent tube removal, tube obstruction, and cellulitis around the ostomy site. Three patients (6%) developed severe complications associated with breakdown of the surgical site. The modified jejunostomy technique was effective for placement of jejunostomy tubes as a complementary procedure to exploratory celiotomy.  相似文献   

6.
OBJECTIVE: To evaluate feasibility of performing laparoscopic-assisted placement of a jejunostomy feeding tube (J-tube) and compare complications associated with placement, short-term feedings, and medium-term healing with surgically placed tubes in dogs. DESIGN: Prospective study. ANIMALS: 15 healthy mixed-breed dogs. PROCEDURES: Dogs were randomly allocated to undergo open surgical or laparoscopic-assisted J-tube placement. Required nutrients were administered by a combination of enteric and oral feeding while monitoring for complications. Radiographic contrast studies documented tube direction and location, altered motility, or evidence of stricture. RESULTS: Jejunostomy tubes were successfully placed in the correct location and direction in all dogs. In the laparoscopic group, the ileum was initially selected in 2 dogs, 2 dogs developed moderate hemorrhage at a portal site, and 2 J-tubes kinked during placement but were successfully readjusted postoperatively. All dogs tolerated postoperative feedings. All dogs developed minor ostomy site inflammation, and 1 dog developed bile-induced dermatitis at the ostomy site. Despite mild, transient neutrophilia, no significant difference was noted in WBC counts between groups. No dog had altered gastric motility or evidence of stricture, although the jejunopexy site remained identifiable in several dogs at 30 days. CONCLUSIONS AND CLINICAL RELEVANCE: Requirements for successful J-tube placement were met by use of a laparoscopic-assisted technique, and postoperative complications were mild and comparable to those seen with surgical placement. Laparoscopic-assisted J-tube placement compares favorably to surgical placement in healthy dogs and should be considered as an option for dogs requiring enterostomy feeding but not requiring a celiotomy for other reasons.  相似文献   

7.
The purpose of this study was to evaluate complications and owner impressions of a low profile gastrostomy device (LPGD) for enteral feeding in dogs. Medical records of dogs that had placement of a percutaneous endoscopic gastrostomy tube followed by a LPGD between 1995 and 2003 were reviewed. Fifteen dogs had 29 devices placed for a variety of disease states in which enteral nutritional support was indicated. The individual tubes were placed for a median duration of 212 d. Most complications occurred more than 15 d after placement and were of no health risk to the animals. The most common reason for LPGD replacement was leakage through the 1-way antireflux valve. Fourteen of 15 owners that were contacted were supportive of the device. Based on its durability, ease of placement, minor complications, and positive owner impressions, we conclude that the LPGD is a valuable device for long-term enteral nutritional support of dogs.  相似文献   

8.
OBJECTIVE: To evaluate complications and outcomes associated with use of gastrostomy tubes in dogs with renal failure. DESIGN: Retrospective study. ANIMALS:56 dogs. PROCEDURE: Medical records were reviewed for dogs with renal failure that were treated by use of gastrostomy tubes. RESULTS: Mean +/- SD BUN concentration was 134 +/- 79 mg/dl and mean serum creatinine concentration was 9.0 +/- 3.8 mg/dl. Low-profile gastrostomy tubes were used for initial placement in 10 dogs, and traditional gastrostomy tubes were used in 46 dogs. Mild stoma-site complications included discharge, swelling, erythema, and signs of pain in 26 (46%) of dogs. Twenty-six gastrostomy tubes were replaced in 15 dogs; 11 were replaced because of patient removal, 6 were replaced because of tube wear, and 3 were replaced for other reasons. Six tubes were replaced by low-profile gastrostomy tubes. Gastrostomy tubes were used for 65 +/- 91 days (range, 1 to 438 days). Eight dogs gained weight, 11 did not change weight, and 17 lost weight; information was not available for 20 dogs. Three dogs were euthanatized because they removed their gastrostomy tubes, 2 were euthanatized because of evidence of tube migration, and 1 died of peritonitis. CONCLUSIONS AND CLINICAL RELEVANCE: Gastrostomy tubes appear to be safe and effective for improving nutritional status of dogs with renal failure.  相似文献   

9.
Interest in noninvasive feeding tube placement in companion animals led to the adaption of a human technique utilizing endoscopy to place nasojejunal feeding tubes. Data from medical records in which nasojejunal feeding tubes were attempted were reviewed. Feeding tubes were attempted and successfully placed in five dogs within a median of 35 min. Feeding tubes remained in place for approximately 7 days. Complications included facial irritation (5/5), sneezing (5/5), fractured facial sutures (4/5), vomiting (3/5), diarrhea (3/5), crimping of feeding tube (3/5), regurgitation (1/5), epistaxis (1/5), clogging of the feeding tube (2/5), and oral migration with premature removal of the feeding tube (1/5). The deployment technique used in this study was found to be cumbersome. Despite minor complications, endoscopy can be used to rapidly and accurately place nasoenteric feeding devices.  相似文献   

10.
A new percutaneous insertion technique for esophageal feeding tubes in cats is presented. The technique has been successfully applied in 12 feline patients. The placement technique is relatively simple, takes approximately five minutes to perform, and requires a scalpel blade, a curved hemostat, and an applicator for the insertion of the feeding tube. In contrast to other esophageal tube placement techniques, the tube is inserted into the definitive aboral position in a one-step procedure. Because of its shoehorn shape, the applicator allows the tube to be inserted into the esophagus safely and precisely. Placement of the tube in the midcervical area does not interfere with the function of the pharynx and avoids having the animal irritated by the presence of the tube. The chosen diameter of the tube is large enough to permit feeding of diluted, blended, commercial canned food. For the patients of this study, feeding was started after recovery from anesthesia, and tubes were removed without complications once the animals had started to eat voluntarily.  相似文献   

11.
Objective – To evaluate a method for endoscopically guided nasojejunal tube placement allowing short‐term postduodenal feeding and chyme withdrawal in dogs. Design – Pilot study. Setting – University teaching hospital. Animals – Three healthy Beagle dogs with jejunal nipple valve fistulas. Interventions – After the dogs were anesthetized, an 8 Fr, 250‐cm polyvinyl chloride catheter was advanced through a gastroscope into the jejunum. Correct jejunal placement was established using endoscopic visualization and confirmed by fluoroscopy and radiography. The proximal end of the tube was pulled out through 1 nostril and sutured to the skin of the forehead. Thereafter, jejunal feeding was administered for 4 days. Follow‐up examinations included daily confirmation of the tube's position using radiography, physical examination, and blood analyses. Withdrawal of jejunal chyme was performed after jejunal and oral feeding. Measurements and Main Results – Fluoroscopic examination confirmed that endoscopic visualization alone allowed correct jejunal placement. During a 4‐day postduodenal feeding period, repeated radiographic examination revealed stable positioning of the tubes within the jejunum with minor cranial displacement. The tubes were functional throughout the study without causing identifiable problems. Repeated physical examinations and blood analysis showed no abnormalities. We were able to administer the daily caloric requirements as a liquid diet. Jejunal chyme was successfully withdrawn via the tube. Conclusions – Endoscopically guided nasojejunal tube placement was shown to be a minimally invasive, well‐tolerated method for short‐term jejunal feeding in healthy dogs. This technique is a viable option for dogs requiring jejunal feeding but not laparotomy. The feasibility of chyme sampling is another unique application of the procedure.  相似文献   

12.
Objective— To report a technique for tube cystostomy placement via a minimally invasive inguinal approach and outcome in 9 dogs and 6 cats with urinary tract obstruction or detrusor atony.
Study Design— Case series.
Animals— Dogs (n=9) and cats (6).
Methods— Medical records (January 2004–January 2008) of dogs and cats that had tube cystostomy via an inguinal approach were reviewed. Retrieved data included signalment, diagnosis, surgical technique, and complications. Access to the bladder was through a muscle splitting approach in the inguinal region with the cystostomy tube placed through a skin incision made several centimeters proximal to this incision and secured in the bladder by a purse string suture. Cystopexy during closure of the muscle layers ensured secure closure and minimized the likelihood of uroabdomen if tube dislodgment occurred.
Results— Cystostomy tubes were placed in 5 cats as an emergency procedure for treatment of acute urinary tract obstruction or urethral rupture, and as an elective procedure in 9 dogs and 1 cat. No complications occurred during cystostomy tube placement. Postprocedural complications were minor (peristomal irritation in 2 dogs with latex catheters, catheter laceration, premature removal) and only occurred when tubes were retained for >4 weeks. Urinary tract infection at catheter removal in 6 dogs resolved with antibiotic administration.
Conclusions— An inguinal approach for cystostomy tube placement facilitated rapid catheter placement into the bladder with minimal soft tissue dissection. Cystopexy during abdominal wall closure provided peritoneal protection should premature dislodgement of the cystostomy tube occur.
Clinical Relevance— An inguinal approach should be considered for rapid tube cystostomy particularly in metabolically compromised animals.  相似文献   

13.
Nonendoscopic tube gastrostomy was performed on 41 anesthetized dogs using the technique of Fulton and Dennis with or without gastric insufflation prior to tube placement. Immediately after tube placement, dogs were euthanized and postmortem examinations performed. When gastric insufflation was not performed (group I), gastrostomy tubes penetrated the visceral surface of the stomach in 25% of dogs. The deep leaf of the omentum was interposed between stomach and body wall in the majority of these dogs, exposing other intra-abdominal organs to potential injury. Additionally, displacement and tethering of the spleen cranial to the gastrostomy site were observed in 33% of dogs in group I. Similar results were obtained when preplacement gastric insufflation was performed after the orogastric tube was inserted sufficiently far to displace the stomach laterally against the body wall (group II). In contrast, consistent positioning of gastrostomy tubes through the parietal surface of the stomach was achieved when the stomach was insufflated prior to lateralizing the left abdominal wall with the gastric end of the orogastric tube (group III). It was concluded that the blind percutaneous gastrostomy technique is made safer by insufflating the stomach immediately prior to pushing the gastric wall laterally into contact with the parietal peritoneum. J Vet Intern Med 1996;10:15–20. Copyright © 1996 by the American College of Veterinary Internal Medicine .  相似文献   

14.
OBJECTIVE: To determine indications for cystostomy tube use in dogs and cats, complications associated with their use, and outcome of dogs and cats in which cystostomy tubes had been inserted. DESIGN: Retrospective case series. ANIMALS: 37 dogs and 39 cats. PROCEDURES: Information was obtained from medical records. Long-term follow-up information was obtained by use of a client questionnaire. RESULTS: Indications for cystostomy tube placement were bladder dysfunction, urinary tract rupture, obstructive urinary tract neoplasia, urinary diversion following urogenital surgery, obstructive urolithiasis, and feline lower urinary tract disease. Median time tubes were in place was 11 days, but duration of tube use was significantly longer for animals with bladder dysfunction than for animals with urinary tract trauma, urinary diversion, or urinary tract obstruction. Thirty-seven (49%) animals had tube complications. Development of complications was not significantly associated with species, age, body weight, duration of tube use, or tube type, except that animals were significantly more likely to develop complications following long-rather than short-term use. In 42 animals, the underlying condition resolved and the tube was removed; 22 animals died or were euthanatized with the tube in place. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that cystostomy tubes may be used for animals with various conditions related to problems with urine outflow. Nearly half the animals in the study developed complications related to the cystostomy tube, suggesting that potential complications should be discussed with owners prior to tube placement. However, most complications were easily resolved.  相似文献   

15.
Objective – To describe the clinical use of a novel, minimally invasive fluoroscopic technique for the wire‐guided placement of nasojejunal tubes (NJT) in dogs. Design – Retrospective study (September 22, 2006–October 2, 2010). Setting – University veterinary teaching hospital. Animals – Twenty‐six consecutive dogs with intolerance of, or contraindications to gastric feeding that underwent attempted fluoroscopic NJT placement. No dogs were excluded from analysis. Interventions – All dogs underwent attempted fluoroscopic NJT placement using a novel fluoroscopic wire‐guided technique. Measurements and Main Results – Patient data were collected in concert with information about the NJT placement procedure as well as the maintenance and utilization of the tube. The primary diagnosis in dogs undergoing NJT placement was pancreatitis in 60%. The ability to achieve transpyloric passage of the tube was 92.3% (24/26) and the ability to achieve jejunal access was 78.2%. In the second half of the study period, the ability to achieve jejunal access was significantly higher than in the first half of the study period suggesting that technical proficiency improves over time. Mean duration of the procedure was 35.3±20 minutes. Significant oral migration was a complication of NJT placement in some dogs. The median duration of feeding was 3.3 days (range 0.3–10.5). Conclusions – Fluoroscopic wire‐guided NJT placement is a viable method for sustained postpyloric feeding in dogs. Success in acquiring jejunal access improves with experience. The NJT may be utilized as a strategy to provide enteral nutritional support to the population of dogs with contraindications to, or intolerance of gastric feeding.  相似文献   

16.
Established procedures for nasogastric intubation are difficult to perform in dogs because of anatomic variation of nasal passages and turbinate structures. Twenty-five clinically normal dogs were used to improve and refine the technique of nasogastric tube placement, and 13 clinical patients at our teaching hospital were evaluated for malnutrition and were considered candidates for nutritional support by nasogastric tube feeding. An improved method for the placement of nasogastric tubes in dogs was used. By pushing the external nares dorsally while advancing the tube in a caudoventral, medial direction, the tube passed through the ventral meatus and into the oropharynx and esophagus easily. The procedure does not require chemical restraint, and the complication of epistaxis was not observed in any dog. Materials required to perform this technique are inexpensive, and the method can be used for the administration of nutritional support, fluids, drugs, or contrast material.  相似文献   

17.
The objective of this study was to describe method of placement, and frequency and severity of complications associated with a subpalpebral lavage system placed in the medial aspect of the equine inferior eyelid. The inferomedial subpalpebral lavage (ISPL) tube is positioned deep in the medial aspect of the inferior conjunctival fornix so that the footplate lies flat between the lower eyelid and the anterior surface of the nictitans. Retrospective data from the placement of 92 ISPL systems placed in 86 horses during a 31-month period were examined. Tube placement was performed using sedation and regional anesthesia only in 59% of horses. The median duration of tube placement was 19 days (range: 1-61 days). Seventy-one horses were treated for up to 55 days following discharge from hospital with an ISPL tube in place. No complications were reported with 59% of ISPL systems. Non-ocular complications were found in 38% of ISPL systems and included tube displacement from the conjunctival fornix (18%), suture loss requiring resuturing of the system to the horse's head (14%), and damage necessitating replacement of the injection port (6%). Ocular complications were recorded in 3% of horses and were limited to inferior eyelid swelling. Vision was retained in 88% of horses. The ISPL system is easily and safely placed, and well tolerated for extended periods. It appears to be associated with infrequent and minor complications when compared with placement of subpalpebral lavage tubes in the superior eyelid.  相似文献   

18.
Traditional cystostomy tubes (used for temporary or permanent diversion of urine in dogs and cats) are long (> or = 22 cm) and cumbersome to stabilize, requiring sutures or bandages to hold the tube against the body. Use of a low-profile gastrostomy port system as a low-profile cystostomy tube (LPCT) in 4 dogs and a cat was investigated; owner satisfaction with the device was assessed. Technical difficulty associated with placement and management of LPCTs was similar to that for traditional cystostomy tubes; with LPCTs, activity and mobility of pets was not compromised, and bandaging was not required. Complications included lower urinary tract infection, mild peristomal leakage of urine and leakage from components of the system, and subcutaneous peristomal infection. Four of 5 owners considered the tube to be easy to use; all owners said they would be comfortable repeating their decision to use the LPCT in their pet.  相似文献   

19.
Percutaneous gastrostomy tubes were placed non-endoscopically in 31 cats and 10 dogs using either a rigid insertion tube (n=13) or an Eld gastrostomy tube applicator (n=28). Tubes were placed successfully in 38 of the 41 animals and the consequent feeding was of therapeutic benefit to 31 of the animals. Six of 41 died or were euthanased for reasons unrelated to gastrostomy. In four cases (10 per cent), gastrostomy failed with respect to correct tube placement or tube feeding. Overall complications occurred in 18 of 41 animals. Severe procedural complications occurred in two cats; a cardiorespiratory arrest during pharyngeal manipulation and erroneous tube placement through the distal oesophagus. Moderate late complications included peristomal food leakage (n=2), peristomal abscess (n=2) and pyloric outflow obstruction by a migrated tube (n=1). Complications associated with the feeding procedure, nausea and vomiting (n=3), led to aspiration pneumonia in one case.  相似文献   

20.
A method for locating an electrode catheter for observing electrical activities of the fasciculus atrioventricularis (bundle of His) without fluoroscopic guidance is described. A catheter which contains 4 electrodes and 2 internal capillary tubes was developed; the catheter has 2 distal orifices 18 mm apart. The position of the catheter tip is determined by observing blood pressure recordings from the two internal capillary tubes; when the tip is positioned properly, the proximal orifice will monitor atrial pressure and the distal orifice will detect ventricular pressure. This catheter was utilized on 14 mongrel dogs (19 to 27 kg). Recordings of atrioventricular bundle activities were successfully obtained from 12 of 14 dogs without any fluoroscopic guidances.  相似文献   