首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Insufficient agreement on scoring hip quality might be caused by differences in the assessability of a radiograph (exposure, contrast, positioning, and diagnostic quality). We studied the agreement in assessability of standard ventrodorsal hip-extended radiographs by experienced (nine) and inexperienced (21) observers, using the standard subjective method of quality control, currently applied in screening programs. The effect of assessability on the agreement of scoring hip quality [dysplastic vs. nondysplastic and the final Federation Cinologique International (FCI) score] was also investigated. There was a significant difference ( P <0.0001) in agreement on assessability between the experienced and inexperienced observers. In 68% of evaluations, experienced observers stated that the radiograph was assessable. Inexperienced observers evaluated the radiographs as being assessable in only 46.5% of evaluations. Increased interobserver agreement on assessability of a radiograph did not increase the overall interobserver agreement in the diagnosis of hip dysplasia, nor did it result in consistent scoring of the hip status from that radiograph, despite a significant ( P <0.05) increase in agreement of FCI scoring with an increasing agreement on assessability at a one to five ratio in the experienced group. The inconsistent evaluation of radiographic quality, as well as the inconsistent evaluation of the hip quality, caused differences in diagnosing hip dysplasia and FCI scoring in the same dog ranging from excellent hips to moderate hip dysplasia. Therefore, the credibility of the FCI screening method for canine hip dysplasia, using the standard hip-extended radiographic view, as currently applied in most European countries, is questionable.  相似文献   

2.
Experienced and inexperienced observers evaluated the assessability of 50 radiographs (25 dogs) and determined the hip status (dysplasia/nondysplasia and final scoring according Fédération Cynologique Internationale [FCI]‐criteria) individually. A radiographic technical quality assessment was performed in a separate reading session. Interobserver agreement in determining dysplasia/nondysplasia and FCI‐scoring did not significantly increase with the increasing quality of a radiograph, irrespective whether these observers are experienced or not. There was a significant agreement between the technical quality assessment and assessability (P<0.0005). Despite the effort to objectify radiographic quality and to present high‐quality radiographs to observers, interobserver agreement on dysplasia/nondysplasia and final scoring, remains low, even in the experienced group. Although increased radiographic quality narrows the range of scoring, the range remains unacceptably high.  相似文献   

3.
A qualitative scoring method was devised to describe foot shape in dairy cattle, which relied solely on visual observations. Four independent trained observers used the method to assess the foot shape of 248 cows located on three farms on two different occasions, and the percentages of agreement and near-agreement for intra-observer and interobserver variation on scores for foot shape were calculated. Score assessment methods were suitable for describing features with a broad variation within one score value; reducing the number of observers did not improve best agreement between separate observations by more than 80 per cent.  相似文献   

4.
OBJECTIVE: To determine whether results of the Ortolani method of hip joint palpation in dogs were related to distraction index (DI), Norberg angle, or radiographic hip score. DESIGN: Cross-sectional study. ANIMALS: 459 clinically normal dogs. PROCEDURE: Dogs were sedated for radiography and palpation of the hip joints. Results of hip joint palpation were classified as negative, mild positive, moderate positive, or severe positive. Distraction indices were measured for all dogs. Norberg angles were measured for 380 dogs for which ventrodorsal hip-extended radiographic projections were available. Hip scores assigned by the Orthopedic Foundation for Animals (OFA) were available for 95 dogs. RESULTS: Age, weight, and sex were not significantly associated with results of hip joint palpation. There was moderate correlation between results of hip joint palpation and DI (r = 0.636), low-moderate correlation between results of hip joint palpation and OFA hip scores (rs = 0.437), and weak negative correlation (r = -0.236) between results of hip joint palpation and Norberg angle. For joints without degenerative joint disease (DJD), there was a significant linear relationship between results of hip palpation and DI; however, for joint with DJD, there was not. Results of hip joint palpation were 5.3-fold as likely to be negative for dogs with DJD as for dogs without. CLINICAL IMPLICATIONS: Results of hip joint palpation were at best moderately correlated with radiographic measures of hip joint laxity. Therefore, hip joint palpation should be combined with hip-extended and stress radiography when assessing hip joint quality.  相似文献   

5.
Measurement of glomerular filtration rate (GFR) via gamma camera uptake of 99mTc‐diethylenetriaminepentaacetic acid is a standard method for quantifying renal function. Aims of this retrospective, observer agreement study were to determine intra‐ and interobserver variation in GFR values for cats with chronic kidney disease and to determine whether renal insufficiency classification changed between observers. Guideline cut‐points were established for the difference in repeated GFRs to differentiate changes caused by therapeutic effect vs. inherent variation. Included cats had a diagnosis of chronic kidney disease and had undergone GFR examinations between the years of 2010 and 2013. Twenty‐nine GFR studies were sampled. Each study was read twice, 6 months apart, by two veterinary radiologists and one radiology resident. Modified Bland–Altman plots were used to investigate differences between readings 1 and 2 by observer and between pairs of observers by reading. Reliability of clinical classification was assessed through comparisons between readings and observers. Measurements were not systematically different between readings for the experienced observers but were higher in reading 1 than reading 2 for the inexperienced observer. Measurements were not systematically different between the experienced observers in reading 1 or between any two observers in reading 2. Reliability for GFR measurements was high among experienced observers; variations in GFR measurements rarely led to differences in clinical classification. Results suggested that, for experienced observers, changes in GFR values following treatment in cats with chronic kidney disease between ?0.4 and 0.4 mL/min/kg may be due to inherent variability rather than treatment effect.  相似文献   

6.
Measurement of the tibial plateau slope from lateral hind-limb radiographs is a preoperative requirement when performing tibial plateau leveling osteotomy (TPLO) for repair of the cruciate-deficient stifle in dogs. Two measurements of the tibial plateau slope in 312 stifles of 156 dogs were taken from lateral radiographs by each of three observers with varying degrees of experience in the measurement method. Intraobserver variability was +/-3.4 degrees, and interobserver variability was +/-4.8 degrees. No significant differences were identified for the intraobserver measurements; however, in evaluating interobserver variability, a significant difference was found between the inexperienced observer and the two experienced observers.  相似文献   

7.
Objectives : The objectives of this study were to quantify the sensitivity and specificity of visual assessment of radiographs of the canine elbow in detecting ulnar trochlear notch sclerosis, to establish interobserver and intra‐observer variation for the presence and grade of sclerosis and to quantify the effect of radiographic exposure on observer grading. Methods : Mediolateral elbow radiographs were obtained from Labrador retrievers (n=34) aged between six and 18 months. Radiographs from dogs with an arthroscopic diagnosis of fragmented medial coronoid process (n=17) and those from a control population (n=17) were subjected to observer grading for the presence or absence of and the grade of ulnar trochlear notch sclerosis. Interobserver and intra‐observer variation and observer sensitivity and specificity were calculated. Digital data from the ulnar trochlear notch were correlated with mean observer grade to quantify the effect of radiographic exposure on observer grade. Results : Interobserver agreement was “fair” (kappa=0·251 to 0·369) and intra‐observer agreement was “moderate” to “substantial” (kappa=0·462 to 0·667). The sensitivity of observer assessment was 72 per cent with a specificity of 22 per cent. Mean observer grade was not significantly correlated with the degree of radiographic exposure (P=0·70). Clinical Significance : Ulnar trochlear notch sclerosis is a phenomenon associated with fragmented medial coronoid process. However, interobserver agreement in grading this feature is only fair, being identified by observers with moderate sensitivity but with relatively poor specificity. This low specificity may predispose to overdiagnosis in clinical cases. Intra‐observer agreement is moderate to substantial, suggesting that individuals can reliably quantify this radiological feature on multiple occasions. The ability of observers to assess the degree of sclerotic change is not significantly affected by radiographic exposure.  相似文献   

8.
Background – Cutaneous cytology is used in veterinary dermatology to assess bacteria and yeast on the skin surface and in the ears for diagnostic purposes and to monitor treatment success. A number of methods were used in reported studies to quantify micro‐organisms on cytology, but evaluation of the intra‐ and interobserver reliability of the methods is rare. Objective – The aim of this study was to evaluate the intra‐ and interobserver reliability of a semiquantitative cytology assessment method frequently used in practice. Methods – A total of 60 experienced and inexperienced veterinarians and veterinary students were asked to evaluate 10 glass slides and 18 photographs of cutaneous cytology twice. Cocci, rods, yeast, neutrophilic and eosinophilic granulocytes and macrophages were graded from 0 to 4+. Results – The intra‐observer reproducibility for evaluating the slides in the experienced group was 84.3%; in the inexperienced group it was 82.6%. For the photographs, the intra‐observer reproducibility was 92.1% in both groups. The interobserver reproducibility for evaluating the slides was 81.6 and 81.0% in the experienced and inexperienced group, respectively; corresponding values for the photographs were 91.0 and 90.0%. There was no significant difference between different participants or between the first and second evaluation by each participant for any of the parameters graded. Conclusion and clinical importance – Based on these results, this semiquantitative method of grading can be recommended for evaluating and monitoring of antimicrobial therapy in daily practice.  相似文献   

9.
Pelvis size plays an important role to prevent dystocia in cattle caused by the foeto-maternal disproportion in commonly primiparous females. The reproducibility and repeatability are two important aspects for the reliability of the measurements to use in the selection of cattle for culling. Pelvic measures were taken with a Rice pelvimeter from 224 young cattle (180 females and 44 males) of four beef breeds in South Africa. One experienced and two inexperienced observers each measured pelvic height and width twice. The proportion measurements with a maximum difference of 0.5 cm within animal compared with the first measurement by the experienced observer are around 80% and by the inexperienced observers around 50% for pelvic height and around 60% for pelvic width. Breed and sex do not affect the reliability of pelvimetry by an experienced observer. Under- and overestimation of pelvis size were observed in inexperienced observers, which seems to be unrelated to breed and sex.  相似文献   

10.
Joint effusion is one of the classic radiographic signs of osteoarthritis, but no information is available regarding clinicians' ability to detect joint effusion radiographically. This study determined the accuracy and precision of experienced and inexperienced observers in detecting joint effusion of the distal interphalangeal (DIP), metacarpophalangeal (MCP) and midcarpal joints on radiographs. Fresh cadaverous forelimbs were loaded in a material testing machine to mimic a standing horse. The joints were gradually distended and lateromedial and dorsopalmar radiographs were acquired. The images were assessed by three experienced and three inexperienced observers. This study showed that the sensitivity was high for both groups for all joints and projections. Specificity was high for the experienced group but low for the inexperienced group. There was a significant positive correlation between joint distension and severity of joint effusion when reported by experienced observersfor most views (except DIP joint), but only for the MCP joint for inexperienced observers. Interoperator agreement was poor to fair for the experienced group and poor for the inexperienced group. In conclusion, the accuracy and precision of grading joint effusion on radiographs was highly subjective and related to experience.  相似文献   

11.
Intracranial hypertension is a cause of cerebral ischemia and neurologic deficits in dogs. Goals of this retrospective study were to test interobserver agreement for MRI measurements of optic nerve sheath diameter and associations between optic nerve sheath diameter, signalment data, and presumed intracranial hypertension status in a cohort of dogs. A veterinary radiologist interpreted scans of 100 dogs and dogs were assigned to groups based on presence or absence of at least two MRI characteristics of presumed intracranial hypertension. Two observers who were unaware of group status independently measured optic nerve diameter from transverse T2‐weighted sequences. Mean optic nerve sheath diameter for all dogs was 3 mm (1–4 mm). The mean difference between observers was 0.3 mm (limits of agreement, ?0.4 and 1.0 mm). There was no correlation between optic nerve sheath diameter and age for either observer (r = ?0.06 to 0.00) but a moderate positive correlation was observed between optic nerve sheath diameter and body weight for both observers (r = 0.70–0.76). The 22 dogs with presumed intracranial hypertension weighed less than the 78 dogs without (P = 0.02) and were more often female (P = 0.04). Dogs with presumed intracranial hypertension had a larger ratio of optic nerve sheath diameter to body weight for each observer‐side pair (P = 0.01–0.04) than dogs without. Findings indicated that the ratio of MRI optic nerve sheath diameter relative to body weight may be a repeatable predictor of intracranial hypertension in dogs.  相似文献   

12.
The objectives of this study were to assess the reliability of a numerical rating scale (NRS) and a verbal rating scale (VRS) for the assessment of lameness in horses and to determine whether they can be used interchangeably. Sixteen independent observers graded the severity of lameness in 20 videotaped horses, and the agreement between and within observers, correlation and bias were determined for each scale. The observers agreed with each other in 56 per cent of the observations with the NRS and in 60 per cent of the observations with the VRS, and the associated Kendall coefficient of concordance was high. Similar trends were evident in the agreement between two observations by each observer. The correlation between and within observers was high for both scales. There were no significant differences (bias) among the observers' mean scores when using either scale. There was a significant correlation between the lameness scores attributed when using the two scales, but the differences between the scores when plotted against their overall mean were unacceptable for clinical purposes. The results indicate that the NRS and VRS are only moderately reliable when used to assess lameness severity in the horse, and that they should not be used interchangeably.  相似文献   

13.
OBJECTIVE: To determine the value of oblique versus ventrodorsal myelographic views for lesion lateralisation in canine thoracolumbar disc disease. METHODS: The ventrodorsal and oblique views from 196 lumbar myelograms of dogs with single thoracolumbar disc extrusions or protrusions were blindly and independently reviewed by two of the authors for evidence of lesion lateralisation. Medical records were reviewed for details regarding hemilaminectomy surgery. The side (left versus right) of the surgery and whether or not the disc material was retrieved were noted. RESULTS: Both reviewers lateralised significantly more disc lesions from the oblique views (93 and 95 per cent) than from the ventrodorsal views (59 and 70 per cent) (P<0.001). Using a combination of oblique and ventrodorsal views, 194 (99 per cent) and 195 (99.5 per cent) lesions were lateralised. Unilateral hemilaminectomy was performed in 193 dogs with myelographic lateralisation and in one dog without myelographic lateralisation. The side of spinal cord decompression corresponded with the myelographic findings in all dogs showing lateralisation on myelography. In the dog without myelographic lateralisation, a left (randomly chosen) hemilaminectomy revealed dorsal protrusion of the annulus fibrosus. CLINICAL SIGNIFICANCE: Myelography, including oblique, ventrodorsal and lateral views, is an accurate method for determining lateralisation of extruded or protruded disc material in the vertebral canal before decompressive surgery. Combined oblique and ventrodorsal views are more useful than either view alone and should be routinely obtained in all lumbar myelographic studies when investigating thoracolumbar disc disease.  相似文献   

14.
Computed tomography (CT) provides excellent bony detail, whereas magnetic resonance (MR) imaging is superior in evaluating the neural structures. The purpose of this prospective study was to assess interobserver and intermethod agreement in the evaluation of cervical vertebral column morphology and lesion severity in Great Danes with cervical spondylomyelopathy by use of noncontrast CT and high‐field MR imaging. Fifteen client‐owned affected Great Danes were enrolled. All dogs underwent noncontrast CT under sedation and MR imaging under general anesthesia of the cervical vertebral column. Three observers independently evaluated the images to determine the main site of spinal cord compression, direction and cause of the compression, articular process joint characteristics, and presence of foraminal stenosis. Overall intermethod agreement, intermethod agreement for each observer, overall interobserver agreement, and interobserver agreement between pairs of observers were calculated by use of kappa (κ) statistics. The highest overall intermethod agreements were obtained for the main site of compression and direction of compression with substantial agreements (κ = 0.65 and 0.62, respectively), whereas the lowest was obtained for right‐sided foraminal stenosis (κ = 0.39, fair agreement). For both imaging techniques, the highest and lowest interobserver agreements were recorded for the main site of compression and degree of articular joint proliferation, respectively. While different observers frequently agree on the main site of compression using both imaging techniques, there is considerable variation between modalities and among observers when assessing articular process characteristics and foraminal stenosis. Caution should be exerted when comparing image interpretations from multiple observers.  相似文献   

15.
Investigation of temporomandibular joint (TMJ) disease requires a clear diagnostic image, which can be challenging to obtain using conventional radiography. The aim of this study was to compare five different oblique radiographic views with the head in lateral recumbency, assessing the clarity of visualization of the normal TMJ anatomy. The views under investigation were the laterorostral-laterocaudal oblique at a 10° and 20° rotation of the head ("nose-up" view), laterorostral-laterocaudal oblique with a rostrocaudal X-ray beam angulation of 10° and 20°, and a parallax view with the beam centered over C2 and collimated to include the TMJ region, using the divergence of the X-ray beam to project the TMJs separately on the radiograph. The views were performed on both TMJs of thirty canine cadavers and were graded independently by experienced and inexperienced observers. Grading was performed on the mandibular fossa, condylar process, joint space, retroarticular process, and the overall TMJ, and was based on a four-point scale. Mean grades for each component and for the overall joint were compared for each observer and each projection. Mean grades were significantly (P < 0.05) higher for the "Nose-up" projections than the angled beam or parallax projections, as was interobserver agreement, and both observers showed significantly higher (P < 0.05) mean grades for the 20(o) "Nose-up" angulation than the 10(o) "Nose-up" angulation. These results suggest that a latero 20(o) rostral-laterocaudal oblique gives the best representation of the anatomy of the TMJ of the dog of the projections assessed, and should be considered when investigating clinical cases of TMJ disease.  相似文献   

16.
Reasons for performing study: Criteria for the radiographic evaluation of navicular bones in horses have been published to standardise classification of radiographic signs. However, intra‐ and interobserver agreement have not been established. Objective: To determine intra‐ and interobserver agreement in the evaluation of radiographic and computed tomographic (CT) navicular changes. It was hypothesised that: 1) intraobserver agreement would be better than interobserver agreement; 2) agreement would be better for CT than for radiography; and 3) pathological changes would be recognised with greater certainty with CT. Methods: Radiographs and CT scans of 60 cadaver navicular bones were evaluated by 3 observers using published criteria. A subset of 30 studies was evaluated twice by one observer. Agreement was tested using the kappa statistic. Certainty about pathological changes was evaluated by giving the observers the option to choose ‘not sure’. Results: Agreement varied from poor to almost perfect for radiographic evaluation and from poor to substantial for CT evaluation. For radiographic evaluation mean interobserver agreement was fair, as it was for CT evaluation. For radiographic evaluation mean intraobserver agreement was moderate as it was for CT evaluation. Pathological changes were evaluated with greater certainty on CT scans compared to radiographs; however, this was not associated with improved agreement. Conclusions: Variations in classification of navicular lesions in radiographic and CT studies were considerable between and within observers and challenge the use of such studies for diagnostic and prognostic purposes. Potential relevance: The results of this study allowed the identification of evaluation criteria with sufficient precision to be useful for navicular bone evaluation.  相似文献   

17.
OBJECTIVE: To determine the reproducibility and accuracy of computed tomographic (CT) measurements of pituitary gland dimensions in healthy dogs. ANIMALS: 35 healthy sexually intact adult dogs. PROCEDURES: 2 observers independently viewed CT images of the skull in 35 dogs twice. Pituitary gland height, width, length, and volume and pituitary gland height-to-brain area ratio (P:B ratio) were measured or calculated. Intraobserver and interobserver agreement indexes (AIs) were calculated for pituitary gland dimensions. Computed tomography was performed also on 5 phantoms, and both observers measured phantom dimensions twice. True-value AIs were calculated for the phantom study. RESULTS: The mean +/- SD interobserver AI between observer 1 and 2 for pituitary gland height and the P:B ratio was 0.90 +/- 0.07. The intraobserver AI for pituitary gland height and the P:B ratio was 0.97 +/- 0.04 for observer 1 and 0.94 +/- 0.04 for observer 2. The intra and interobserver AIs for the other dimensions were lower than those for pituitary gland height and the P:B ratio. All phantom dimensions on CT images were underestimated significantly, compared with their true values. CONCLUSIONS AND CLINICAL RELEVANCE: The intra- and interobserver AIs for pituitary gland dimension measurements on CT images were high. However, the same observer preferably should perform serial measurements. Window settings influence pituitary gland dimension measurements, and predetermined window settings are recommended to make comparisons among dogs. Pituitary gland dimension measurements made from CT images in our study underestimated the true values.  相似文献   

18.
OBJECTIVE: To assess intra- and interobserver repeatability of ocular biometric measurements obtained by means of high-resolution B-mode ultrasonography in dogs. Animals-6 Beagles without ocular abnormalities. PROCEDURES: B-mode ultrasonography was performed bilaterally with a 10.5-MHz broadband compact linear array transducer. All measurements were made on 2 different occasions by 2 observers. The Bland-Altman method was used to assess agreement between measurements obtained by the 2 observers and between the 2 sets of measurements obtained by each observer. RESULTS: Intra- and interobserver repeatability was highest for larger measurements, such as depth of the eye and depth of the anterior chamber. When repeatability was examined, bias was significantly different from 0 for only a few measurements, but the percentage difference between observations was as high as 180% for some measurements. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that most measurements of intraocular distances and structures obtained by means of high-resolution B-mode ultrasonography have acceptable intra- and interobserver repeatability. However, the percentage difference between observations can be high for smaller measurements.  相似文献   

19.
Lameness scoring is a routine procedure in dairy industry to screen the herds for new cases of lameness. Subjective lameness scoring, which is the most popular lameness detection and screening method in dairy herds, has several limitations. They include low intra-observer and inter-observer agreement and the discrete nature of the scores which limits its usage in monitoring the lameness. The aim of this study is to develop an automated lameness scoring system comparable with conventional subjective lameness scoring by means of artificial neural networks. The system is composed of four balanced force plates installed in a hoof-trimming box. A group of 105 dairy cows was used for the study. Twenty-three features extracted from ground reaction force (GRF) data were used in a computer training process which was performed on 60 per cent of the data. The remaining 40 per cent of the data were used to test the trained system. Repeatability of the lameness scoring system was determined by GRF samples from 25 cows, captured at two different times from the same animals. The mean sd was 0.31 and the mean coefficient of variation was 14.55 per cent, which represents a high repeatability in comparison with subjective vision-based scoring methods. Although the highest sensitivity and specificity values were seen in locomotion score groups 1 and 4, the automatic lameness system was both sensitive and specific in all groups. The sensitivity and specificity were higher than 72 per cent in locomotion score groups 1 to 4, and it was 100 per cent specific and 50 per cent sensitive for group 5.  相似文献   

20.
A visual analog scale and a numeric scoring scale were designed for the assessment of dynamic intraoperative mesenteric portovenography in the dog and cat. Two independent observers evaluated both scoring scales for reproducibility (differences between observers) and repeatability (within-observer differences) in the assessment of 60 trial portovenograms. Agreement (interchangeability) of both scales was evaluated by comparing the scores obtained in the assessment of 200 portovenograms obtained from 100 dogs and cats. There was no statistical difference between the two observers when scoring the same portovenogram for either the visual analog scale (p = .730, reproducibility coefficient = 17.85 units) or the numeric scoring scale (scores identical, reproducibility coefficient = 0). There was no statistical difference, for either of the observers, when the same portovenogram was assessed on two separate occasions using the visual analog scale (observer 1, p = .35, repeatability coefficient = 17.93 units; observer 2, p = .42, repeatability coefficient = 8.27 units) or the numeric scoring scale (scores given by both observers were identical, repeatability coefficient = 0 for both observers). The results of comparison between the visual analog scale and numeric scoring scale confirmed that the two scoring systems were not directly interchangeable. Although both scoring systems demonstrated good reproducibility and repeatability, the numeric scoring scale possessed a number of inherent deficiencies that suggested it was not the method of choice for the assessment of the subjective data obtained from dynamic intraoperative mesenteric portovenography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号