首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到6条相似文献,搜索用时 0 毫秒
1.
In six normal beagles and 27 dogs with spontaneous focal or multifocal liver lesions, contrast-enhanced ultrasonography using Sonazoid® was performed. Sonazoid® is a newly developed second-generation contrast agent with the ability to be used for real-time contrast imaging along with parenchymal imaging. An appropriate protocol for the evaluation of all three phases (arterial, portal, and parenchymal) was established based on the results for normal beagles. By evaluation of the echogenicity of hepatic nodules during the arterial and parenchymal phases it was possible to differentiate malignant tumors from benign nodules with very high accuracy. In 15 of 16 dogs diagnosed as malignant tumors, nodules were clearly hypoechoic to the surrounding normal liver during the parenchymal phase. Additionally, malignant tumors had different echogenicity compared with the surrounding normal liver during the arterial phase in 14 of 15 dogs. In the portal phase, there were no characteristic findings. Contrast-enhanced ultrasonography with Sonazoid® appears to improve the characterization of canine focal and multifocal hepatic lesions.  相似文献   

2.
Eight adult dogs with no evidence of liver disease, weighing between 8 and 25 kg were imaged after injection of a microbubble contrast medium using harmonic ultrasound imaging. All dogs received three separate bolus contrast injections, and six dogs also received three separate constant rate infusions each. Time/Mean Pixel Value curves were generated for selected regions of the liver. Upslope, downslope, baseline, peak, change, and time to peak were calculated. For bolus injection (averaging all subjects), upslope was 3.85 +/- 1.50 Mean Pixel Values/s, downslope was -0.71 +/- 0.30 Mean Pixel Values/s, baseline was 72.38 +/- 17.82 Mean Pixel Values, peak was 120.26 +/- 17.44 Mean Pixel Value, change from baseline to peak was 47.88 +/- 6.92 Mean Pixel Values, time to peak (from injection) was 22.88 +/- 6.79 s, and time to peak (from first upslope) was 13.88 +/- 1.55 s. Data acquisition and analysis from constant rate infusions was more cumbersome than for bolus, and results were less repeatable. There were significant differences (p < .005) in upslope, downslope, peak values, and time to peak between the two methods. These baseline data may prove useful in the evaluation of dogs with diffuse hepatic disease.  相似文献   

3.
Modern ultrasound contrast media are gas-containing stabilized microbubbles that remain intact in the circulating blood for several minutes after intravenous injection and increase the intensity of the backscattered ultrasound. When the microbubbles disappear from the blood, they can be detected in the parenchyma of the liver and the spleen for about 30 more minutes (late liver- and spleen-specific phase). The insonated microbubbles produce second harmonic ultrasound frequencies, whose detection requires nonconventional ultrasound modalities such as pulsed inversion imaging. Nonconventional ultrasound techniques can also be used without microbubbles because second harmonics can be generated by ultrasound in tissues as well. The physical principles and advantages of nonconventional ultrasound techniques are described. The circulating microbubbles can be used not only to enhance weak Doppler signals, but also to perform dynamic contrast studies. Contrast-enhanced dynamic ultrasound studies--similar to contrast-enhanced CT and MRI examinations--have been used in humans to characterize lesions noninvasively (i.e., without biopsies) found during conventional ultrasound examinations. To map the distribution of contrast medium in a nodule or in an organ, specific scanning techniques such as stimulated acoustic emission have been developed. Stimulated acoustic emission occurs when high acoustic pressure ultrasonic waves disrupt the stationary or slowly moving microbubbles. This results in the release of a large amount of harmonic ultrasound frequencies. When the stimulated acoustic emission technique is used for dynamic studies, scanning must be interrupted several times to allow the microvasculature of the lesion to refill with microbubbles (interval delay imaging). The contrast patterns of malignant and benign hepatic nodules in humans have been the most intensively studied. Another type of dynamic study in humans measures the transit time of the contrast medium; that is, how fast the peripherally injected microbubbles reach the hepatic veins. Hepatic cirrhosis can be differentiated from other diffuse parenchymal liver diseases by a shorter transit time. Introducing nonconventional ultrasound techniques and ultrasound contrast media in veterinary diagnostic imaging may have potential value; however, intensive research should be carried out before ultrasound contrast agents can routinely be used in clinical practice.  相似文献   

4.
Ultrasonography of the liver of 181 Holstein-Friesian cows was performed and blood samples were collected for analysis. The hepatic ultrasonograms were evaluated and the echoes were analyzed digitally. After slaughter, liver specimens were taken and examined histopathologically. Of the 181 animals, 120 had a normal liver and 61 had hydropic degeneration of the liver, diagnosed through histopathologic examination. Diagnostic accuracy rates for hydropic degeneration were determined based on the following test positive conditions: a) for biochemical analysis—high levels of aspartate aminotransferase, alanine aminotransferase, total bilirubin and non-esterified fatty acids; b) for ultrasonography—presence of dark pattern and blurring of edges; and c) for digital analysis—low echo means at 1 cm and 3 cm from the hepatic surface. Digital analysis had the highest overall specificity, accuracy and positive predictive values for hydropic degeneration, followed by ultrasonography. The results suggest that ultrasonography and digital analysis of hepatic ultrasonograms can be used for diagnosis of hydropic degeneration of the liver in place of biochemical analysis.  相似文献   

5.
Diagnostic imaging techniques are an important part of the diagnostic workup and staging of cancer patients. Ultrasound is of particular interest in this respect. In so far as tumor metastases are concerned, ultrasonography of regional lymph nodes and of the liver can provide valuable information. In humans many criteria, some of them objective, have been evaluated as indicators of malignancy. The most diagnostically helpful of these include the short/long axis ratio of the lymph node, the pattern of distribution of the blood vessels within the lymph node, and to some extent the calculated values for resistive and pulsatility indices. Putative objective criteria to improve the specificity of ultrasound for metastases detection in the liver have also been evaluated. These include perfusion indices, primarily using analysis of Doppler frequencies (Doppler perfusion index) and hepatic venography using an ultrasound contrast agent. Contrast-enhanced ultrasonography is a new and promising area to help the initial diagnosis and characterization of malignancy, particularly for focal lesions in the liver. This review discusses the use of ultrasound for detection of metastases and presents material from four veterinary cases.  相似文献   

6.
Diagnosis of unilateral diaphragmatic paralysis in dogs is currently based on fluoroscopic detection of unequal movement between the crura. Bilateral paralysis may be more difficult to confirm with fluoroscopy because diaphragmatic movement is sometimes produced by compensatory abdominal muscle contractions. The purpose of this study was to develop a new method to evaluate diaphragmatic movement using M‐mode ultrasonography and to describe findings for normal and diaphragmatic paralyzed dogs. Fifty‐five clinically normal dogs and two dogs with diaphragmatic paralysis were recruited. Thoracic radiographs were acquired for all dogs and fluoroscopy studies were also acquired for clinically affected dogs. Two observers independently measured diaphragmatic direction of motion and amplitude of excursion using M‐mode ultrasonography for dogs meeting study inclusion criteria. Eight of the clinically normal dogs were excluded due to abnormal thoracic radiographic findings. For the remaining normal dogs, the lower limit values of diaphragmatic excursion were 2.85–2.98 mm during normal breathing. One dog with bilateral diaphragmatic paralysis showed paradoxical movement of both crura at the end of inspiration. One dog with unilateral diaphragmatic paralysis had diaphragmatic excursion values of 2.00 ± 0.42 mm on the left side and 4.05 ± 1.48 mm on the right side. The difference between left and right diaphragmatic excursion values was 55%. Findings indicated that M‐mode ultrasonography is a relatively simple and objective method for measuring diaphragmatic movement in dogs. Future studies are needed in a larger number of dogs with diaphragmatic paralysis to determine the diagnostic sensitivity of this promising new technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号