首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE: To analyze and compare the geometry of the anterior segment of rabbit and human eyes, with relevance for the evaluation of intraocular lenses, and to review rabbit models used in our laboratory for the evaluation of different ophthalmic devices and solutions. PROCEDURES: Fifteen rabbit and 15 human eyes (10 phakic and 5 pseudophakic/group) obtained postmortem were used. Anterior-posterior length, equatorial diameter, and white-to-white (corneal diameter) were measured with calipers. The eyes were then analyzed with a very high-frequency ultrasound (Artemis, Ultralink) for measurements of the anterior chamber depth, and anterior chamber and ciliary sulcus diameters. The capsular bag diameter was measured with calipers from a posterior view, and the diameter and thickness of the crystalline lenses were measured after their excision from the phakic eyes. RESULTS: Although the size of the rabbit eye is overall smaller than the size of the human eye, the dimensions of the anterior segment of rabbit eyes are generally larger. The differences between rabbit and human eyes were statistically significant (Wilcoxon rank sum test) in terms of anterior-posterior length, equatorial diameter, white-to-white measurements (P < 0.0001), anterior chamber diameter (P = 0.0004), ciliary sulcus diameter (P = 0.0012), and crystalline lens diameter and thickness (P = 0.0003). CONCLUSIONS: Experimental evaluation of design features of new phakic intraocular lenses in rabbit eyes may be inconclusive without adaptation of their size/design, contrary to the evaluation of new pseudophakic lenses by implantation in the capsular bag. The rabbit is a very valuable model for the experimental evaluation of different ophthalmic devices and solutions.  相似文献   

2.
OBJECTIVE: To determine the reproducibility and accuracy of computed tomographic (CT) measurements of pituitary gland dimensions in healthy dogs. ANIMALS: 35 healthy sexually intact adult dogs. PROCEDURES: 2 observers independently viewed CT images of the skull in 35 dogs twice. Pituitary gland height, width, length, and volume and pituitary gland height-to-brain area ratio (P:B ratio) were measured or calculated. Intraobserver and interobserver agreement indexes (AIs) were calculated for pituitary gland dimensions. Computed tomography was performed also on 5 phantoms, and both observers measured phantom dimensions twice. True-value AIs were calculated for the phantom study. RESULTS: The mean +/- SD interobserver AI between observer 1 and 2 for pituitary gland height and the P:B ratio was 0.90 +/- 0.07. The intraobserver AI for pituitary gland height and the P:B ratio was 0.97 +/- 0.04 for observer 1 and 0.94 +/- 0.04 for observer 2. The intra and interobserver AIs for the other dimensions were lower than those for pituitary gland height and the P:B ratio. All phantom dimensions on CT images were underestimated significantly, compared with their true values. CONCLUSIONS AND CLINICAL RELEVANCE: The intra- and interobserver AIs for pituitary gland dimension measurements on CT images were high. However, the same observer preferably should perform serial measurements. Window settings influence pituitary gland dimension measurements, and predetermined window settings are recommended to make comparisons among dogs. Pituitary gland dimension measurements made from CT images in our study underestimated the true values.  相似文献   

3.
By using ultrasound biomicroscopy (UBM), the cross-sectional structures of the entire iridocorneal angle (ICA) which are unable to assess with gonioscopic examination were evaluated objectively and quantitatively in live healthy and glaucomatous dogs. The ICAs of normotensive eyes in healthy dogs with normal open angle (NOR), a predisposition to primary closed angle glaucoma (PCAG) (PREDIS) and suffering from unilateral PCAG (UNI), as well as the ICAs of hypertensive eyes with acute and chronic PCAG (ACG and CRG), were assessed. The opening of the ciliary cleft in PREDIS was smaller than that in NOR. In UNI, the opening and area of the ciliary cleft were significantly decreased compared with those of NOR and PREDIS. ACG had widespread structural abnormalities including marked decrease in the ciliary cleft and scleral venous plexus, and a thinner sclera than those in normotensive eyes, whereas the ICA collapsed in CRG with the thinnest sclera. Medical therapy-responsive glaucomatous cases had wider ciliary cleft and scleral venous plexus than unresponsive ones. These findings suggest that the ciliary cleft and scleral venous plexus of the ICA are key structures contributing to not only the pathophysiology of canine glaucoma but also the responsiveness to medical therapy in glaucomatous eyes, and cross-sectional entire structures of the ICA should be evaluated quantitatively with UBM when diagnosing and managing canine glaucoma.  相似文献   

4.
OBJECTIVE: To assess intra- and interobserver repeatability of ocular biometric measurements obtained by means of high-resolution B-mode ultrasonography in dogs. Animals-6 Beagles without ocular abnormalities. PROCEDURES: B-mode ultrasonography was performed bilaterally with a 10.5-MHz broadband compact linear array transducer. All measurements were made on 2 different occasions by 2 observers. The Bland-Altman method was used to assess agreement between measurements obtained by the 2 observers and between the 2 sets of measurements obtained by each observer. RESULTS: Intra- and interobserver repeatability was highest for larger measurements, such as depth of the eye and depth of the anterior chamber. When repeatability was examined, bias was significantly different from 0 for only a few measurements, but the percentage difference between observations was as high as 180% for some measurements. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that most measurements of intraocular distances and structures obtained by means of high-resolution B-mode ultrasonography have acceptable intra- and interobserver repeatability. However, the percentage difference between observations can be high for smaller measurements.  相似文献   

5.
Pelvis size plays an important role to prevent dystocia in cattle caused by the foeto-maternal disproportion in commonly primiparous females. The reproducibility and repeatability are two important aspects for the reliability of the measurements to use in the selection of cattle for culling. Pelvic measures were taken with a Rice pelvimeter from 224 young cattle (180 females and 44 males) of four beef breeds in South Africa. One experienced and two inexperienced observers each measured pelvic height and width twice. The proportion measurements with a maximum difference of 0.5 cm within animal compared with the first measurement by the experienced observer are around 80% and by the inexperienced observers around 50% for pelvic height and around 60% for pelvic width. Breed and sex do not affect the reliability of pelvimetry by an experienced observer. Under- and overestimation of pelvis size were observed in inexperienced observers, which seems to be unrelated to breed and sex.  相似文献   

6.
The iridocorneal angle of the left eye was investigated in 203 Samoyeds. Comparison was made of judgements of the width of the anterior opening of the ciliary cleft when performing gonioscopy with an objective method of estimation based on measurements on goniophotographs. Results indicated high degree of correlation. Various degrees of narrowness of the iridocorneal angle width were revealed and clinical glaucoma with total-angle closure was found in 6 of 203 dogs. The intraocular pressure was significantly (P less than 0.01) higher in eyes with closed iridocorneal angles than in eyes with any other width of the angle. Appearance of the structures of the iridocorneal angle, particularly the pigment bands, indicated extensive individual variation. In approximately 25% of the eyes, dysplasia of the pectinate ligaments of variable degree existed, indicating that this anomaly is common in the Samoyed breed. Significant difference was not evident in intraocular pressure in eyes with different degrees of dysplasia of the pectinate ligaments.  相似文献   

7.
A 34‐day‐old, male, white‐bellied caique (Pionites leucogaster) was presented for a complaint of bilateral buphthalmos. Clinical examination was unremarkable apart from the ophthalmic findings. The ophthalmologic examination was negative for direct, consensual, and dazzle reflexes in both eyes. The intraocular pressure exceeded 40 mm Hg OU. Fluorescein stain demonstrated corneal surface lesions suggestive of exposure keratopathy subsequent to bilateral buphthalmos. Diagnostic imaging tests were conducted to perform ocular biometric measurements and investigate the intraocular structures, including the iridocorneal angle and lens, by means of high‐resolution ultrasonography (HRUS). The presence of congenital glaucoma in this young parrot was strongly suspected after clinical and ophthalmological examination and the results of diagnostic imaging. Pharmacological treatment to reduce intraocular pressure was initiated using dorzolamide hydrochloride 2% and timolol maleate 0.5%. A month later, the parrot's eyes did not show any visual improvement, but the intraocular pressure had returned to normal. The parrot was unable to feed itself and died during a feeding procedure. Postmortem examination revealed ab ingestis pneumonia. Both eyes were submitted for histopathology, with severe anterior segment dysplasia and goniodysgenesis found OU. Histological findings added to the clinical presentation, the ophthalmologic examination and the imaging findings, confirmed the presence of congenital glaucoma.  相似文献   

8.
Objective— To compare the intra‐ and interobserver variability occurring when observers with differing experience levels measure tibial plateau angles (TPAs) with a novel digital radiographic projection program (tibial plateau leveling osteotomy [TPLO] planning program), the Kodak Picture Archiving and Communications System (PACS), and standard sized printed films (SF). Study Design— Cross‐sectional study. Sample Population— Dogs (n=36) with cranial cruciate ligament (CCL) rupture that had a TPLO. Methods— Six observers, divided into 3 equal groups based on experience level, measured TPA on 36 digitally captured radiographic images of tibiae of dogs clinically affected with CCL rupture. Each observer used 3 methods of measuring TPA and repeated the measurements 3 times with each method. The intra‐ and interobserver variability was compared using the coefficient of variation. Results— Averaged over all replications and images, there was no significant difference (P>.05) in the average variability occurring with each method for all but 1 observer. There was no effect of experience level on measurement variability; however, interobserver variability was significantly less with measurements made with the PACS and TPLO planning program compared with measurements made from SF (P<.05). Conclusions— Repeated measurements of TPA made using digital images and computer‐based measurement programs were significantly less variable between observers than those made from images printed on standard radiographic films. Clinical Relevance— Digital radiography and computer‐based measurement programs are effective for determining the TPA, allowing less variability in measurements compared with SF. The ability to manipulate the image may allow better identification of anatomic landmarks.  相似文献   

9.
Transabdominal ultrasonography was performed to visualize the development of intraocular structures of both eyes of four different fetuses in each of two pregnant beagles. Postnatally the development of both eyes of 11 pups was visualized with ultrasonography. Furthermore, biometric measurements of the length of the eye, the depth of cornea, the anterior chamber, the lens (anteroposterior depth and equatorial diameter), and the vitreous body of the fetuses and pups were obtained when these structures could be identified with ultrasonography. In all fetuses the eyes with lens, vitreous body, hyaloid artery, and scleroretinal rim could be clearly identified from day 37 of pregnancy. Postnatally also the cornea, anterior chamber, iris, ciliary body, and optic disc were visible. Biometric measurements revealed, both pre- and postnatally, a continuous growth of the depth of the eye, anterior chamber, lens (anteroposterior depth and equatorial diameter), and vitreous body.  相似文献   

10.
The aims of this study were to establish a normal reference range (mean ± 2 SD) and assess reliability of renal dimensions obtained using transabdominal ultrasonography in Thoroughbred horses (n = 7). A minimum of three ultrasonographic cineloops were obtained from each intercostal space and the left paralumbar fossa by two observers daily for three consecutive days. Renal length, width, and thickness and cortex, medulla, and pelvic dimensions were obtained. Measurements were undertaken by both observers, who were unaware of prior measurements, to assess reproducibility and measured on three separate occasions to evaluate short-term measurement repeatability. Measurements from images obtained by both operators were compared to evaluate image repeatability. The left kidney was consistently identified in the left 15th-17th intercostal space and the paralumbar fossa with maximal length in the 16th intercostal space (12.7 ± 2.0 cm) and maximal width in the paralumbar fossa (7.9 ± 1.1 cm). The right kidney was consistently identified in the right 15th-17th intercostal space with maximal length and maximal width in the 15th intercostal space (16.0 ± 0.7 cm and 7.9 ± 1.0 cm). Reproducibility, image repeatability, measurement repeatability were good to excellent, although were less good for the smaller structures. There were no differences in renal dimensions between horses. Overall renal ultrasonography was reliable and a normal reference range for Thoroughbred horses was established. Renal dimensions vary between rib spaces. As repeatability and reproducibility were excellent for renal length and width, it may be prudent to use those measurements in rib spaces where parameters were maximal.  相似文献   

11.
The aims of this study were to assess the repeatability and reproducibility of transabdominal ultrasonography to assess intestinal wall thickness in adult Thoroughbred horses (n=8). Ultrasonographic cineloops were captured by one examiner from each horse for five consecutive days. During each examination at least three cineloops were obtained for five different intestinal tract locations. Measurements were performed by three separate observers to assess reproducibility and measured on three separate occasions by three observers to evaluate short‐term repeatability. The repeatability of measurements from the duodenum (0.3 ± 0.04 cm), jejunum (0.29 ± 0.05 cm), ventral colon (0.37 ± 0.01 cm), and cecum (0.42 ± 0.03 cm) were good ( P >0.291). The reproducibility of measurements from the duodenum, jejunum, and ventral colon were good ( P >0.394). Reproducibility of measurement of the cecal wall was inadequate ( P =0.01), although the maximum difference between observers was 0.07 cm. It was possible to image all areas on all days, with the exception of the duodenum, which could not be imaged in one horse, on 1 day. Equine intestinal wall measurements are therefore repeatable and reproducible with the exception of reproducibility of the measurements of cecal wall. Although an accepted clinical technique, measurement of cecal wall thickness from intestinal ultrasound images in a clinical setting must be interpreted with care.  相似文献   

12.
ObjectiveTo compare two echocardiographic methods of measuring aortic diameter in short-axis projections.MethodsRight-parasternal short-axis 2-dimensional projections of the left atrium and aorta were obtained from dogs and cats undergoing routine cardiac evaluation. Two investigators measured the aortic valve linear dimension using 2 methods: along the commissure between the non-coronary and right-coronary cusps and along the commissure between the non-coronary and left-coronary cusps. Inter-observer and intra-observer variability and agreement were assessed by comparing blinded measurements with each method by 4 trained observers on a standardized set of images. Measurements were compared for agreement using the limits of agreement analysis. Variability between observers was compared by examining residuals and intraclass correlation.Results274 canine and 100 feline aortic valve images were measured in the first part of the study. One observer demonstrated slight proportional bias, while the other observer showed more variability (less agreement). When results were pooled for both investigators, no bias was identified, and 95% limits of agreement were ±10% of the mean measurement for both species. In the second part of the study, 106 images were measured. Intraobserver variability was <4% for all observers. Inter-observer agreement was very high. Individual bias was identified in some observers, but was considered clinically inconsequential. Normalized differences between the 2 methods of measurement were below ±15% of the measured value for all observers.ConclusionsOur results show sufficient agreement between two common methods used to measure aortic linear dimensions to suggest that these methods are interchangeable.  相似文献   

13.
OBJECTIVE: To assess the intra- and interobserver repeatability of 2-dimensional (2-D) kinematic analysis of walk and sit-to-stand motions in dogs. ANIMALS: 10 healthy adult Labrador Retrievers. PROCEDURES: 10 dogs were filmed during walk and sit-to-stand motions. Five trials were recorded for each dog, 3 of which were digitized. Two observers manually marked 15 landmarks on each frame during the motions of interest for these 3 trials. Each observer repeated the procedure approximately 1 week later. The 2-D joint angles were calculated. Intra- and interobserver coefficients of multiple correlations (CMCs) were calculated for each joint angle-time history. RESULTS: Intraobserver repeatability, assessed as the mean CMCs of 12 joint angle measurements made for 10 dogs by 2 observers, was good or excellent in 23 of 24 (96%) mean CMCs of the joints measured. Interobserver variation, assessed by comparing CMCs of measurements made by 2 observers on 10 dogs on 2 days, was good or excellent in 161 of 240 (67%) CMCs of joints measured. CONCLUSIONS AND CLINICAL RELEVANCE: Intraobserver repeatability of 2-D kinematic measurements made on digitized videotapes was excellent. Interobserver repeatability of these measurements was acceptable.  相似文献   

14.
Objective To determine whether the distance between Schwalbe’s line (the peripheral termination of Descemet’s membrane, i.e., the borderline between the cornea and sclera) and the anterior lens capsule (SLD) is an applicable parameter for correcting raw ultrasound biomicroscopic values of the canine iridocorneal angle (ICA) and to establish a comparative system for the ICA values in different canine breeds with varied body sizes/weights. Animal studied The dogs were divided into four groups based on body weight (BW): <4 kg, 4–8 kg, 8–20 kg, and >20 kg, and 180 normotensive eyes were studied. Procedures The ICA microstructure was examined by ultrasound biomicroscopy (UBM) using 40‐MHz probes in dogs with or without anesthesia/sedation. Linear regression analysis and correlation coefficients were evaluated between SLD or SLD2 and UBM measurements; subsequently, noncorrected and SLD‐corrected UBM values were statistically assessed. Results Significant linear correlations were detected between SLD and the ciliary cleft width, the minimum distance between the angle recess and the scleral venous plexus, and the scleral thickness. Positive linear correlations were also demonstrated between SLD2 and the ciliary cleft area as well as the scleral venous plexus area. Raw UBM measurements were corrected by using a ratio with SLD on the distance or SLD2 on the area. Although noncorrected UBM measurements increased with canine BW, SLD‐corrected UBM values remained similar with no significant statistical differences in any of the dogs. Conclusions Correction with SLD would be clinically useful for comparing UBM measurements of the ICA in dogs with different body sizes/weights.  相似文献   

15.
The aim of the present study was to establish which adrenal gland measurement was characterized by the least variations. To do this, we quantified the variability of seven different size measurements of the canine adrenal gland (maximal length, maximal height at the cranial and caudal poles on longitudinal and transverse images, and maximal width of the cranial and caudal poles) within observer, between observer, and between dogs based on three different measurements made by each of the three observers in six healthy Beagle dogs. The height of the caudal pole of both adrenal glands measured on longitudinal images had the lowest intra‐ and interobserver variability, while measurements of the length had the highest intra‐ and interobserver variability. Other measurements that were characterized by low intra‐ and interobserver variability were: height and width of the caudal pole on transverse images and height of the cranial pole on longitudinal images only. These results provide a basis for further study of the changes in adrenal gland size in dogs with pituitary‐dependent hyperadrenocorticism.  相似文献   

16.
Between 1989 and 1995 nine Great Danes were presented to the small animal clinic of the University of Zurich Teaching Hospital with glaucoma and multiple cysts in the anterior and posterior chamber. In four of the nine dogs cysts were present in both eyes; however, bilateral glaucoma was seen in one case only. Mean intraocular pressure (IOP) at initial presentation was 42 mmHg measured by applanation tonometry. With the exception of one dog, all animals were treated medically for a minimum of 13 days. Two animals were subsequently lost to follow up. Two dogs underwent evisceration with implantation of a silicone prosthesis. The glaucomatous globe was enucleated in three dogs. One owner declined surgery and the dog remained buphthalmic with a poorly controlled IOP. One animal remained visual after trans-scleral diode laser cyclophotocoagulation. Histopathology of the three enucleated globes showed multiple cysts originating from the ciliary body epithelium. The mechanism of IOP elevation is probably by anterior displacement of the iris with narrowing of the angle and collapse of the ciliary cleft. A delicate pre-iridal fibrovascular membrane was also seen in each case, which could have also contributed to the elevation of IOP. The high odds ratio of 2.23 (CI 95% 1.14, 3.99) for glaucoma and 37.01 (CI 95% 16.42, 77.81) for ciliary body cysts suggests they are both inherited in this breed. Pedigree analysis of the affected dogs failed to definitely reveal the mode of inheritance.  相似文献   

17.
The vertebral heart size (VHS) method by Buchanan is based on anatomic landmarks. A potential source of variation among observers is differences in the selection of measurement points. The objective was to test variability between observers with different levels of training in thoracic radiology and small animal clinical practice. Fifty sets of thoracic radiographs of cavalier King Charles spaniels, were divided into five groups; (Normal) normal cardiopulmonary structures, (I) slight cardiomegaly, (II) moderate cardiomegaly, (II +) moderate cardiomegaly with congestive heart failure, and (III +) severe cardiomegaly with congestive heart failure. Cardiomegaly was confirmed by echocardiography to be caused by mitral regurgitation because of myxomatous mitral valve disease. Sixteen observers representing four levels of experience (four observers/level) evaluated the radiographs; (1) European Diplomates in Veterinary Diagnostic Imaging, (2) Experienced small animal clinicians, (3) Trainees in small animal clinical practice (4) Veterinary students. Almost identical mean VHS values were found among the four experience levels for each of the five groups of radiographs with a low coefficient of variation, range 1.5-3.2%. Mean difference among the 16 observers was 1.05 +/- 0.32 vertebrae (v). Mean difference among individuals in each observer group was approximately 0.5 v for all but the groups of trainees were the difference was 0.6-0.9 v. The conclusion is that VHS method for heart size is independent of observer experience but dependent of individual observers selection of reference points and transformation of long and short axis dimensions into VHS units.  相似文献   

18.
Measurements of intestinal wall thicknesses from ultrasound imaging (US) are routinely used to support diagnoses of intestinal disorders in cats, however published studies describing observer agreement are currently lacking. The aim of this retrospective, observer agreement study was to quantify inter- and intraobserver repeatability and agreement in the measurement of intestinal wall layer thicknesses and the segmentation of transverse sections of small intestines in US images of 20 cats. Intestinal wall layer thickness measurements of the mucosa, submucosa, muscularis, serosa layer, and total thickness of these layers were performed on five cats with small cell epitheliotropic lymphoma, five with inflammatory bowel disease, and 10 with other conditions. Thickness measurements and the segmentation encompassing the serosa layer were obtained from five observers four times non-sequentially. The average standard deviation in thickness measurements (95% confidence interval) in the mucosa, submucosa, muscularis, serosa, and total thickness were 0.35 (0.07–0.95), 0.24 (0.07-0.52), 0.22 (0.06-0.49), 0.20 (0.05-0.49), and 0.57 (0.11-1.60) mm, respectively. The average intraclass correlation coefficients, which estimates the degree of consistency in thickness measurements and segmentation areas for each observer, ranged from 0.355 to 0.870 and 0.850 to 0.993, respectively. The interclass correlation coefficient, which estimates the degree of consistency when measuring a thickness or segmentation area over all observers ranged from 0.115 to 0.753, and 0.811 to 0.902, respectively. The overall average Dice Coefficient, which estimates the extent of overlap of the segmentations for all observers was 0.957 (0.933 to 0.972). Our results suggest segmentations of small intestines have a higher interobserver agreement than measurements of intestinal wall thicknesses.  相似文献   

19.
Computed tomography (CT) provides excellent bony detail, whereas magnetic resonance (MR) imaging is superior in evaluating the neural structures. The purpose of this prospective study was to assess interobserver and intermethod agreement in the evaluation of cervical vertebral column morphology and lesion severity in Great Danes with cervical spondylomyelopathy by use of noncontrast CT and high‐field MR imaging. Fifteen client‐owned affected Great Danes were enrolled. All dogs underwent noncontrast CT under sedation and MR imaging under general anesthesia of the cervical vertebral column. Three observers independently evaluated the images to determine the main site of spinal cord compression, direction and cause of the compression, articular process joint characteristics, and presence of foraminal stenosis. Overall intermethod agreement, intermethod agreement for each observer, overall interobserver agreement, and interobserver agreement between pairs of observers were calculated by use of kappa (κ) statistics. The highest overall intermethod agreements were obtained for the main site of compression and direction of compression with substantial agreements (κ = 0.65 and 0.62, respectively), whereas the lowest was obtained for right‐sided foraminal stenosis (κ = 0.39, fair agreement). For both imaging techniques, the highest and lowest interobserver agreements were recorded for the main site of compression and degree of articular joint proliferation, respectively. While different observers frequently agree on the main site of compression using both imaging techniques, there is considerable variation between modalities and among observers when assessing articular process characteristics and foraminal stenosis. Caution should be exerted when comparing image interpretations from multiple observers.  相似文献   

20.
The causes of glaucoma in cats   总被引:2,自引:0,他引:2  
The cause of glaucoma in 131 enucleated eyes from 128 cats was determined in a retrospective histologic study. Obliteration of the ciliary cleft by diffuse iridal melanoma (38 eyes), or other neoplasms (14 eyes), or by the presence of idiopathic lymphocytic-plasmacytic anterior uveitis (53 eyes) were the most frequent lesions likely to explain the development of glaucoma. Secondary changes of inner retinal atrophy, optic disc cupping, scleral thinning with megaglobus, and atrophy of ciliary processes were similar to those described in dogs and human beings with chronic glaucoma. In light of the duration and severity of the glaucoma, the degree of inner retinal atrophy was often less than expected. Diffuse corneal edema and breaks in Descemet's membrane, changes typical of glaucoma in other species, were rarely detected. Eyes with chronic uveitis and glaucoma had collapsed ciliary clefts, iridoscleral adhesions, and posterior displacement of the iris. We were unable to determine whether these changes were consequences of the uveitis and thus responsible for the development of glaucoma, or if they were merely the result of the chronic glaucoma itself.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号