首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
With the development of genetically modified organism (GMO) detection techniques, the Polymerase Chain Reaction (PCR) technique has been the mainstay for GMO detection, and real-time PCR is the most effective and important method for GMO quantification. An event-specific detection strategy based on the unique and specific integration junction sequences between the host plant genome DNA and the integrated gene is being developed for its high specificity. This study establishes the event-specific detection methods for TC1507 and CBH351 maizes. In addition, the event-specific TaqMan real-time PCR detection methods for another seven GM maize events (Bt11, Bt176, GA21, MON810, MON863, NK603, and T25) were systematically optimized and developed. In these PCR assays, the fluorescent quencher, TAMRA, was dyed on the T-base of the probe at the internal position to improve the intensity of the fluorescent signal. To overcome the difficulties in obtaining the certified reference materials of these GM maizes, one novel standard reference molecule containing all nine specific integration junction sequences of these GM maizes and the maize endogenous reference gene, zSSIIb, was constructed and used for quantitative analysis. The limits of detection of these methods were 20 copies for these different GM maizes, the limits of quantitation were about 20 copies, and the dynamic ranges for quantification were from 0.05 to 100% in 100 ng of DNA template. Furthermore, nine groups of the mixed maize samples of these nine GM maize events were quantitatively analyzed to evaluate the accuracy and precision. The accuracy expressed as bias varied from 0.67 to 28.00% for the nine tested groups of GM maize samples, and the precision expressed as relative standard deviations was from 0.83 to 26.20%. All of these indicated that the established event-specific real-time PCR detection systems and the reference molecule in this study are suitable for the identification and quantification of these GM maizes.  相似文献   

2.
To fulfill labeling and traceability requirement of genetically modified (GM) maize for trade and regulation, it is essential to develop an event-specific detection method for monitoring the presence of transgenes. In pursuit of this purpose, we systematically optimized and established a combined event- and construct-specific multiplex polymerase chain reaction (mPCR) technique for simultaneous detection of 8 GM maize lines. Altogether 9 sets of primers were designed, including six that were event-specific for Event176, Bt11, TC1507, NK603, MON863, and Mon810; two that were construct-specific for T25 and GA21, and one for an endogenous zein gene. The transgene in each GM maize line and the endogenous zein gene could be clearly detected and distinguished according to the different sizes of PCR amplicons. The limit of detection (LOD) was approximately 0.25% (v/v), although the detection can be as sensitive as 0.1% as demonstrated by the International Seed Testing Association (ISTA) proficiency test. This study further improves the current PCR-based detection method for GM maize. The method can be used in an easy, sensitive, and cost and time effective way for the identification and quality screening of a specific GM maize line.  相似文献   

3.
As more and more genetically modified (GM) crops are approved for commercialization and planting, the development of quick and on-spot methods for GM crops and their derivates is required. Herein, we established the polymerase chain reaction and agarose gel electrophoresis-free system for the identification of seven GM maize events (DAS-59122-7, T25, BT176, TC1507, MON810, BT11, and MON863) employing a loop-mediated isothermal amplification (LAMP) technique. The LAMP assay was performed using a set of four specific primers at 60-65 °C in less than 40 min, and the results were observed by direct visual observation. In these developed assays, the specificity targeted at each GM maize event based on the event-specific sequence was well confirmed, and the limits of detection were as low as four copies of maize haploid genomic DNA with an exception of 40 copies for MON810 assay. Furthermore, these developed assays were successfully used to test six practical samples with different GM maize events and contents (ranged from 0.0 to 2.0%). All of the results indicated that the established event-specific visual LAMP assays are more convenient, rapid, and low-cost for GM maize routine analysis.  相似文献   

4.
In this study, we developed a novel multiplex polymerase chain reaction (PCR) method for simultaneous detection of up to eight events of genetically modified (GM) maize within a single reaction. The eight detection primer pairs designed to be construct specific for eight respective GM events (i.e., Bt11, Event176, GA21, MON810, MON863, NK603, T25, and TC1507) and a primer pair for an endogenous reference gene, ssIIb, were included in the nonaplex(9plex) PCR system, and its amplified products could be distinguished by agarose gel and capillary electrophoreses based on their different lengths. The optimal condition enabled us to reliably amplify two fragments corresponding to a construct specific sequence and a taxon specific ssIIb in each of the eight events of GM maize and all of nine fragments in a simulated GM mixture containing as little as 0.25% (w/w) each of eight events of GM maize. These results indicate that this multiplex PCR method could be an effective qualitative detection method for screening GM maize.  相似文献   

5.
Many countries have introduced mandatory labeling requirements on foods derived from genetically modified organisms (GMOs). Real-time quantitative polymerase chain reaction (PCR) based upon the TaqMan probe chemistry has become the method mostly used to support these regulations; moreover, event-specific PCR is the preferred method in GMO detection because of its high specificity based on the flanking sequence of the exogenous integrant. The aim of this study was to evaluate the use of very short (eight-nucleotide long), locked nucleic acid (LNA) TaqMan probes in 5'-nuclease PCR assays for the detection and quantification of GMOs. Classic TaqMan and LNA TaqMan probes were compared for the analysis of the maize MON810 transgene. The performance of the two types of probes was tested on the maize endogenous reference gene hmga, the CaMV 35S promoter, and the hsp70/cryIA(b) construct as well as for the event-specific 5'-integration junction of MON810, using plasmids as standard reference molecules. The results of our study demonstrate that the LNA 5'-nuclease PCR assays represent a valid and reliable analytical system for the detection and quantification of transgenes. Application of very short LNA TaqMan probes to GMO quantification can simplify the design of 5'-nuclease assays.  相似文献   

6.
Polymerase chain reaction (PCR) methods have been the main technical support for the detection of genetically modified organisms (GMOs). To date, GMO-specific PCR detection strategies have been developed basically at four different levels, such as screening-, gene-, construct-, and event-specific detection methods. Event-specific PCR detection method is the primary trend in GMO detection because of its high specificity based on the flanking sequence of exogenous integrant. GM canola, event T45, with tolerance to glufosinate ammonium is one of the commercial genetically modified (GM) canola events approved in China. In this study, the 5'-integration junction sequence between host plant DNA and the integrated gene construct of T45 canola was cloned and revealed by means of TAIL-PCR. Specific PCR primers and TaqMan probes were designed based upon the revealed sequence, and qualitative and quantitative TaqMan real-time PCR detection assays employing these primers and probe were developed. In qualitative PCR, the limit of detection (LOD) was 0.1% for T45 canola in 100 ng of genomic DNA. The quantitative PCR assay showed limits of detection and quantification (LOD and LOQ) of 5 and 50 haploid genome copies, respectively. In addition, three mixed canola samples with known GM contents were detected employing the developed real-time PCR assay, and expected results were obtained. These results indicated that the developed event-specific PCR methods can be used for identification and quantification of T45 canola and its derivates.  相似文献   

7.
Because of the genetically modified organisms (GMOs) labeling policies issued in many countries and areas, polymerase chain reaction (PCR) methods were developed for the execution of GMO labeling policies, such as screening, gene specific, construct specific, and event specific PCR detection methods, which have become a mainstay of GMOs detection. The event specific PCR detection method is the primary trend in GMOs detection because of its high specificity based on the flanking sequence of the exogenous integrant. This genetically modified maize, MON863, contains a Cry3Bb1 coding sequence that produces a protein with enhanced insecticidal activity against the coleopteran pest, corn rootworm. In this study, the 5'-integration junction sequence between the host plant DNA and the integrated gene construct of the genetically modified maize MON863 was revealed by means of thermal asymmetric interlaced-PCR, and the specific PCR primers and TaqMan probe were designed based upon the revealed 5'-integration junction sequence; the conventional qualitative PCR and quantitative TaqMan real-time PCR detection methods employing these primers and probes were successfully developed. In conventional qualitative PCR assay, the limit of detection (LOD) was 0.1% for MON863 in 100 ng of maize genomic DNA for one reaction. In the quantitative TaqMan real-time PCR assay, the LOD and the limit of quantification were eight and 80 haploid genome copies, respectively. In addition, three mixed maize samples with known MON863 contents were detected using the established real-time PCR systems, and the ideal results indicated that the established event specific real-time PCR detection systems were reliable, sensitive, and accurate.  相似文献   

8.
The quantification of GMOs by real-time PCR relies on an external calibrant. In this paper the suitability of two DNA calibrants, genomic DNA from plant leaves and plasmidic DNA, was investigated. The PCR efficiencies, the correlation coefficients of the calibration curves, and the ratios between PCR efficiencies of transgenic and endogenous sequences were compared for both calibrants using 59 data sets produced by 43 laboratories. There were no significant differences between plasmidic and genomic DNA except for the PCR efficiencies of the calibration curves for the transgene of the construct-specific real-time PCR method. In the GM system investigated, PCR efficiencies of plasmidic calibrants were slightly closer to the PCR efficiencies observed for the unknowns than those of the genomic DNA calibrant. Therefore, plasmidic DNA was the more suitable calibrant for the PCR measurements on genomic DNA extracted from MON 810 seeds. It is shown that plasmidic DNA is an appropriate choice for the calibration of measurements of MON 810 corn with respect to the DNA copy number ratio.  相似文献   

9.
As more genetically modified plant events are approved for commercialization worldwide, the event-specific PCR method has become the key method for genetically modified organism (GMO) identification and quantification. This study reveals the 3' flanking sequence of the exogenous integration of Oxy-235 canola employing thermal asymmetric interlaced PCR (TAIL-PCR). On the basis of the revealed 3' flanking sequence, PCR primers and TaqMan probe were designed and qualitative and quantitative PCR assays were established for Oxy-235 canola. The specificity and limits of detection (LOD) and quantification (LOQ) of these two PCR assays were validated to as low as 0.1% for the relative LOD of qualitative PCR assay; the absolute LOD and LOQ were low to 10 and 20 copies of canola genomic DNA in quantitative PCR assay, respectively. Furthermore, ideal quantified results were obtained in the practical canola sample detection. All of the results indicate that the developed qualitative and quantitative PCR methods based on the revealed 3' integration flanking sequence are suitable for GM canola Oxy-235 identification and quantification.  相似文献   

10.
Quenching probe (QProbe) polymerase chain reaction (PCR) is a simple and cost-effective real-time PCR assay in comparison with other real-time PCR assays such as the TaqMan assay. We used QProbe-PCR to quantify genetically modified (GM) soybean (Roundup Ready soybean). We designed event-specific QProbes for Le1 (soy endogenous gene) and RRS (recombinant gene), and we quantified certified reference materials containing 0.1, 0.5, 1, 2, and 5% GM soybean. The TaqMan assay was also applied to the same samples, and the results were compared. The accuracy of QProbe-PCR was similar to that of TaqMan assay. When GM soybean content was 0.5% or more, the relative standard deviations of QProbe-PCR were less than 20%. QProbe-PCR is sensitive enough to monitor labeling systems and has acceptable levels of accuracy and precision.  相似文献   

11.
As the genetically modified organisms (GMOs) labeling policies are issued in many countries, qualitative and quantitative polymerase chain reaction (PCR) techniques are increasingly used for the detection of genetically modified (GM) crops in foods. Qualitative PCR and TaqMan real-time quantitative PCR methods to detect and identify three varieties of insect resistant cotton, i.e., Mon531 cotton (Monsanto Co.) and GK19 and SGK321 cottons (Chinese Academy of Agricultural Sciences), which were approved for commercialization in China, were developed in this paper. Primer pairs specific to inserted DNAs, such as Cowpea trypsin inhibitor (CpTI) gene of SGK321 cotton and the specific junction DNA sequences containing partial Cry1A(c) gene and NOS terminator of Mon531, GK19, and SGK321 cotton varieties were designed to conduct the identified PCR assays. In conventional specific identified PCR assays, the limit of detection (LOD) was 0.05% for Mon531, GK19, or SGK321 in 100 ng of cotton genomic DNA for one reaction. Also, the multiplex PCR method for screening the three GM cottons was also established, which could save time and cost in practical detection. Furthermore, a real-time quantitative PCR assay based on TaqMan chemistry for detection of insect resistant gene, Cry1A(c), was developed. This assay also featured the use of a standard plasmid as a reference molecule, which contained both a specific region of the transgene Cry1A(c) and an endogenous stearoyl-acyl carrier protein desaturase (Sad1) gene of the cotton. In quantitative PCR assay, the quantification range was from 0.01 to 100% in 100 ng of the genome DNA template, and in the detection of 1.0, 3.0, and 5.0% levels of three insect resistant cotton lines, respectively, all of the relative standard deviations (RSDs) were less than 8.2% except for the GM cotton samples with 1.0% Mon531 or GK19, which meant that our real-time PCR assays involving the use of reference molecule were reliable and practical for GM insect resistant cottons quantification. All of these results indicated that our established conventional and TaqMan real-time PCR assays were applicable to detect the three insect resistant cottons qualitatively and quantitatively.  相似文献   

12.
To enforce the labeling regulations of genetically modified organisms (GMOs), the application of reference molecules as calibrators is becoming essential for practical quantification of GMOs. However, the reported reference molecules with tandem marker multiple targets have been proved not suitable for duplex PCR analysis. In this study, we developed one unique plasmid molecule based on one pMD-18T vector with three exogenous target DNA fragments of Roundup Ready soybean GTS 40-3-2 (RRS), that is, CaMV35S, NOS, and RRS event fragments, plus one fragment of soybean endogenous Lectin gene. This Lectin gene fragment was separated from the three exogenous target DNA fragments of RRS by inserting one 2.6 kb DNA fragment with no relatedness to RRS detection targets in this resultant plasmid. Then, we proved that this design allows the quantification of RRS using the three duplex real-time PCR assays targeting CaMV35S, NOS, and RRS events employing this reference molecule as the calibrator. In these duplex PCR assays, the limits of detection (LOD) and quantification (LOQ) were 10 and 50 copies, respectively. For the quantitative analysis of practical RRS samples, the results of accuracy and precision were similar to those of simplex PCR assays, for instance, the quantitative results were at the 1% level, the mean bias of the simplex and duplex PCR were 4.0% and 4.6%, respectively, and the statistic analysis ( t-test) showed that the quantitative data from duplex and simplex PCR had no significant discrepancy for each soybean sample. Obviously, duplex PCR analysis has the advantages of saving the costs of PCR reaction and reducing the experimental errors in simplex PCR testing. The strategy reported in the present study will be helpful for the development of new reference molecules suitable for duplex PCR quantitative assays of GMOs.  相似文献   

13.
A novel analytical procedure based on the combination of multiplex PCR, restriction analysis, and CGE-LIF to unambiguosly and simultaneously confirm the presence of multiple lines of genetically modified corn is proposed. This methodology is based on the amplification of event-specific DNA regions by multiplex PCR using 6-FAM-labeled primers. Subsequently, PCR products are digested by a mixture containing specific restriction endonucleases. Thus, restriction endonucleases selectively recognize DNA target sequences contained in the PCR products and cleave the double-stranded DNA at a given cleavage site. Next, the restriction digest is analyzed by CGE-LIF corroborating the length of the expected restriction fragments, confirming (or not) the existence of GMOs. For accurate size determination of the DNA fragments by CGE-LIF a special standard DNA mixture was produced in this laboratory for calibration. The suitability of this mixture for size determination of labeled DNA fragments is also demonstrated. The usefulness of the proposed methodology is demonstrated through the simultaneous detection and confirmatory analysis of samples containing 0.5% of GA21 and MON863 maize plus an endogenous gene of maize as control.  相似文献   

14.
For implementation of the issued regulations and labeling policies for genetically modified organism (GMO) supervision, the polymerase chain reaction (PCR) method has been widely used due to its high specificity and sensitivity. In particular, use of the event-specific PCR method based on the flanking sequence of transgenes has become the primary trend. In this study, both qualitative and quantitative PCR methods were established on the basis of the 5' flanking sequence of transgenic soybean A2704-12 and the 3' flanking sequence of transgenic soybean A5547-127, respectively. In qualitative PCR assays, the limits of detection (LODs) were 10 copies of haploid soybean genomic DNA for both A2704-12 and A5547-127. In quantitative real-time PCR assays, the LODs were 5 copies of haploid soybean genomic DNA for both A2704-12 and A5547-127, and the limits of quantification (LOQs) were 10 copies for both. Low bias and acceptable SD and RSD values were also achieved in quantification of four blind samples using the developed real-time PCR assays. In addition, the developed PCR assays for the two transgenic soybean events were used for routine analysis of soybean samples imported to Shanghai in a 6 month period from October 2010 to March 2011. A total of 27 lots of soybean from the United States and Argentina were analyzed: 8 lots from the Unites States were found to have the GM soybean A2704-12 event, and the GM contents were <1.5% in all eight analyzed lots. On the contrary, no GM soybean A5547-127 content was found in any of the eight lots. These results demonstrated that the established event-specific qualitative and quantitative PCR methods could be used effectively in routine identification and quantification of GM soybeans A2704-12 and A5547-127 and their derived products.  相似文献   

15.
Qualitative and quantitative analytical methods were developed for the new event of genetically modified (GM) maize, MON863. One specific primer pair was designed for the qualitative polymerase chain reaction (PCR) method. The specificity and sensitivity of the designed primers were confirmed. PCR was performed on genomic DNAs extracted from MON863, other GM events, and cereal crops. Single PCR product was obtained from MON863 by the designed primer pair. Eight test samples including GM maize MON863 were prepared at 0.01 approximately 10% levels and analyzed by PCR. Limit of detection of the method was 0.01% for GM maize MON863. On the other hand, another specific primer pair and probe were also designed for quantitative method using a real-time polymerase chain reaction. As a reference molecule, a plasmid was constructed from a taxon-specific DNA sequence for maize, a universal sequence for a cauliflower mosaic virus (CaMV) 35S promoter used in most genetically modified organisms, and a construct-specific DNA sequence for the MON863 event. Six test samples of 0.1, 0.5, 1.0, 3.0, 5.0 and 10.0% of GM maize MON863 were quantitated for the validation of this method. At the 3.0% level, the bias (mean vs true value) for MON863 was 3.0%, and its relative standard deviation was 5.5%. Limit of quantitation of the method was 0.5%. These results show that the developed PCR methods can be used to qualitatively and quantitatively detect GM maize MON863.  相似文献   

16.
To meet the labeling and traceability requirement of genetically modified (GM) maize and their products for trade and regulation, it is essential to develop a specific detection method for monitoring the presence of GM content. In this work, six GM maize lines, including GA21, Bt11, NK603, Bt176, Mir604, and Mon810, were simultaneously detected by universal primer-multiplex-polymerase chain reaction (UP-M-PCR), and the amplicons for the six event-specific genes as well as the endogenous Ivr gene were successfully separated by the method of capillary electrophoresis-laser-induced fluorescence (CE-LIF). The UP-M-PCR method overcame the disadvantages in conventional M-PCR, such as complex manipulation, lower sensitivity, amplification disparity resulting from different primers, etc., and in combination with CE-LIF, it obtained a high sensitivity of 0.1 ng for both single and mixed DNA samples. The established method can be widely used for the qualitative identification of the GM maize lines.  相似文献   

17.
We have developed a new immunoassay method to detect genetically modified (GM) maize and rape containing phosphinothricin-N-acetyltransferase (PAT). PAT encoded by Bialaphos resistance gene (bar) was highly expressed in soluble form in Escherichia coli BL21(DE3) and purified to homogeneity by Ni2+ affinity chromatography. A simple and efficient extraction and purification procedure of PAT from GM maize and rape was developed by means of the immunoaffinity column (IAC) as a cleanup tool. Purified polyclonal antibodies against PAT was produced and coupled covalently to CNBr-activated Sepharose 4B. Both the binding conditions and elution protocols were optimized. The IAC was successfully employed to isolate and purify the PAT from the various tissues of GM maize (Bt11 and Bt176) and rapes (MS1/RF1 and MS8/RF3). Enzyme linked immunosorbent assay (ELISA) procedures were established further on to measure the PAT protein. GM maize cannot be differentiated from non-GM maize by ELISA. But IAC-ELISA allowed 0.5% GMOs to be detected in MS1/RF1 and MS8/RF3 and 10% GMOs to be detected in Bt11 and Bt176, which makes this method an acceptable method to access PAT protein in GM rapes and maize.  相似文献   

18.
根据七种转基因玉米的重组DNA结构分别对Bt11、Bt176 、Mon810 、Mon863 、TC1507、 GA21 和NK603设计转化体特异性引物,进行多重PCR检测。在此基础上分别设计和筛选了七种转基因玉米转化体特异性oligo探针,制备转基因玉米的寡核苷酸芯片。实验表明,该探针特异性好,同常用的凝胶电泳检测方法相比,芯片杂交的灵敏度(0.01%),优于凝胶电泳检测(0.1%),由于采用了多重PCR技术一次可同时检测多个基因,提高了检测的准确率和效率。  相似文献   

19.
Since the 18th of April 2004, two new regulations, EC/1829/2003 on genetically modified food and feed products and EC/1830/2003 on traceability and labeling of GMOs, are in force in the EU. This new, comprehensive regulatory framework emphasizes the need of an adequate tracing system. Unique identifiers, such as the transgene genome junction region or a specific rearrangement within the transgene DNA, should form the basis of such a tracing system. In this study, we describe the development of event-specific tracing systems for transgenic maize lines Bt11, Bt176, and GA21 and for canola event GT73. Molecular characterization of the transgene loci enabled us to clone an event-specific sequence into a plasmid vector, to be used as a marker, and to develop line-specific primers. Primer specificity was tested through qualitative PCRs and dissociation curve analysis in SYBR Green I real-time PCRs. The primers were then combined with event-specific TaqMan probes in quantitative real-time PCRs. Calibration curves were set up both with genomic DNA samples and the newly synthesized plasmid DNA markers. It is shown that cloned plasmid GMO target sequences are perfectly suitable as unique identifiers and quantitative calibrators. Together with an event-specific primer pair and a highly specific TaqMan probe, the plasmid markers form crucial components of a unique and straighforward tracing system for Bt11, Bt176, and GA21 maize and GT73 canola events.  相似文献   

20.
Because of the increasing use of maize hybrids with genetically modified (GM) stacked events, the established and commonly used bulk sample methods for PCR quantification of GM maize in non-GM maize are prone to overestimate the GM organism (GMO) content, compared to the actual weight/weight percentage of GM maize in the grain sample. As an alternative method, we designed and assessed a group testing strategy in which the GMO content is statistically evaluated based on qualitative analyses of multiple small pools, consisting of 20 maize kernels each. This approach enables the GMO content evaluation on a weight/weight basis, irrespective of the presence of stacked-event kernels. To enhance the method's user-friendliness in routine application, we devised an easy-to-use PCR-based qualitative analytical method comprising a sample preparation step in which 20 maize kernels are ground in a lysis buffer and a subsequent PCR assay in which the lysate is directly used as a DNA template. This method was validated in a multilaboratory collaborative trial.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号