首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 0 毫秒
1.
The purpose of this project was to establish a procedure and reference values for glomerular filtration rate (GFR) using contrast-enhanced computed tomography (CT) in eight healthy dogs. A single section of the kidney was scanned sequentially after bolus injection (3 ml/s) of iohexol (300 mg/kg). Time-attenuation curves were constructed and the GFR per volume of kidney was calculated using Patlak graphical analysis software. The GFR was then converted from contrast clearance per unit volume (ml/min/ml) to contrast clearance per body weight (ml/min/kg). Individual kidney and global GFR were calculated using both CT and nuclear scintigraphy. Global GFR for each dog was also determined by plasma iohexol clearance. Contrast-enhanced CT underestimated the global GFR compared with the other two methods. The average global GFR was 2.57 +/- 0.33 ml/ min/kg using functional CT and 4.06 +/- 0.37 ml/min/kg using plasma iohexol clearance. There was significant (P < 0.05) interobserver variability of CT GFR of the right kidney and total GFR. There was decreased interobserver variability for the left kidney. There was no difference in the intraobserver variability for CT-determined individual kidney and global GFR. There was no difference between the motion corrected and nonmotion corrected values for individual and global CT GFR. Nuclear scintigraphy produced a slightly higher coefficient of variation than contrast-enhanced CT, 2.9% and 1.0%, respectively. It is hypothesized that altered renal blood flow, hematocrit of the small vessels, and nephrotoxicity play a role in the underestimation of GFR by contrast-enhanced CT.  相似文献   

2.
The scintigraphically measured percentage dose uptake of 99mTc-DTPA by the kidneys and the plasma clearance of 99mTc-DTPA have been reported to correlate well with inulin clearance. These two parameters were evaluated in seven dogs with known or suspected naturally occurring renal disease and compared to simultaneously measured renal inulin clearance. Correlation between inulin clearance and the 99mTc-DTPA plasma clearance was better ( p =.0016) than the correlation between the percentage DTPA uptake by the kidney. It was concluded that measurement of 99mTc-DTPA plasma clearance is a more accurate method to estimate global glomerular filtration rate (GFR) than the percentage kidney uptake.  相似文献   

3.
Naruepon  Kampa  DVM  Ursula  Wennstrom  DVM  Peter  Lord  BVSc  FRCVS  Robert  Twardock  DVM  PhD  Enn  Maripuu  BSc  Per  Eksell  DVM  PhD  Sten-Olof  Fredriksson  BSc 《Veterinary radiology & ultrasound》2002,43(4):383-391
Determinations of different methods of measurement of uptake of 99mTc-DTPA using scintigraphy of glomerular filtration rate (GFR) were made from 29 studies on 10 healthy beagle dogs. GFR was measured by calculating the percentage dose uptake (integral method) and rate of uptake (slope method) of 99mTc-DTPA using manual kidney regions of interest (ROI) and automatic kidney and background ROIs at different time periods of the uptake phase. These results were compared using linear regression analysis to the GFR obtained from 99mTc-DTPA plasma clearance using multiple blood samples. The best correlation coefficient between percentage DTPA uptake and GFR by DTPA clearance (r = 0.84, P < 0.001) was derived from time intervals between 30s-120s with a perirenal background ROI at 1 or 2 pixels out from the kidney ROI using automatic kidney ROI at 20% threshold. With the slope method, the best correlation coefficient (r = 0.85, P < 0.001) was obtained from time intervals between 30s-peak with the background ROI at 2 pixels out from the kidney ROI using automatic ROI at 35% threshold. The offset was higher, and the correlation varied more with different ROIs and the method was unreliable at time intervals extending beyond the peak radioactivity. Manual kidney ROIs with automatic background ROIs had slightly lower correlations. With DTPA renography both integral and slope uptake method with automatic kidney and background ROIs are accurate methods to estimate the GFR, but that the integral method is much more stable to variations in ROI size and the duration of the uptake phase of the renogram.  相似文献   

4.
The current standard scintigraphic method for estimating glomerular filtration rate (GFR) in dogs is the integral method, which normalizes renal GFR to body weight. The plasma volume method, that is normalizing GFR to plasma volume, has been reported to be more physiologically correct. The aim of this prospective study was to test the effect of hydration status on GFR measured by these two methods in a group of dogs with suspected renal disease. Eleven dogs were recruited. All dogs underwent standardized scintigraphic examinations before and after 15 ml/kg of fluid was administered intravenously at 5–7 ml/kg/min. Individual kidney GFR estimates (n = 22) were calculated using both methods and a consensus of two observers who were unaware of clinical findings. Individual kidney GFR increased significantly (P = 0.0008) after fluid administration using the integral method and individual kidney GFR using the plasma volume method remained constant. Percentage differences for individual kidney GFR before and after fluid administration were 31.4 ± 58.1% (change ± 95% CI) for the integral method and 0.1 ± 70% (change ± 95% CI) for the plasma volume method. Intravenously administered fluid increased individual kidney GFR from low to normal in 10 of 22 kidneys using the integral method and in 1 of 22 kidneys using the plasma volume method. Findings supported the use of the plasma volume method for scintigraphic calculation of GFR in dogs with suspected renal disease and indicated that errors of kidney status classification may more likely occur when the integral method is used.  相似文献   

5.
Scintigraphy is currently the reference standard for diagnosing feline hyperthyroidism; however, computed tomography (CT) is more widely available in veterinary practice. The purposes of this prospective study were to describe the CT appearance of thyroid glands in cats with hyperthyroidism and compare CT findings with findings from 99mTc–pertechnetate scintigraphy. Twenty‐five adult hyperthyroid cats were included. Plain CT images were acquired for each cat and the following characteristics recorded for each thyroid lobe: visibility, delineation, position, attenuation, shape, and subjective size. Scintigraphic images were also acquired and the following characteristics recorded: radiopharmaceutical uptake, delineation, ectopic foci, shape, and subjective size. In CT images, thyroid lobes were most commonly found between the second and fourth cervical vertebrae, dorsolateral to the trachea. Affected thyroid lobes (based on scintigraphy reference standard) were most commonly oval and moderately enlarged in CT images. A heterogeneous attenuation pattern (isoattenuating to adjacent soft tissues with hypo‐ and hyperattenuating foci) was most commonly found in affected thyroid lobes. A positive correlation (P < 0.01) was identified between CT and scintigraphy for left‐to‐right thyroid lobe size relationship and subjective size of the larger thyroid lobe. The CT estimated mass was significantly higher (median = 148.8; range = [0;357.6]) for the more active thyroid lobe compared to the less active thyroid lobe (median = 84.6; range = [0;312.3]); (W = 154; P < 0.01). Findings indicated that CT may not reliably differentiate unilateral vs. bilateral hyperthyroidism in cats; however, CT may be a reliable alternative test for correctly identifying the more active thyroid lobe.  相似文献   

6.
Thyroid scintigraphy is commonly used for evaluation of cats with hyperthyroidism, with the thyroid‐to‐salivary ratio (T/S) being the most common method to quantify the degree of thyroid activity and disease. Calculation of thyroid‐to‐background ratios (T/B) or percent thyroidal uptake of 99mTcO?4 (TcTU) has only been reported in a few studies. The purpose of this prospective, cross‐sectional study was to evaluate a number of quantitative scintigraphic indices as diagnostic tests for hyperthyroidism, including the T/S, three different T/B, TcTU, and estimated thyroid volume. Of 524 cats referred to our clinic for evaluation of suspected hyperthyroidism, the diagnosis was confirmed (n = 504) or excluded (n = 20) based on results of a serum thyroid panel consisting of thyroxine (T4), triiodothyronine (T3), free T4 (fT4), and thyroid‐stimulating hormone (TSH) concentrations. In the hyperthyroid cats, median values for TcTU, T/S, and three T/B ratios were all significantly higher (P < 0.001) than values in euthyroid suspect cats or clinically normal cats. All scintigraphic parameters were relatively sensitive and specific as diagnostic tests for hyperthyroidism, but the T/S ratio had the highest test accuracy. The T/S ratio correlated strongly with the TcTU (r = 0.85). However, the TcTU had a higher and more significant correlation (P < 0.01) with serum T4 (r = 0.76 vs. 0.64), T3 (r = 0.77 vs. 0.64), and estimated thyroid volume (r = 0.62 vs. 0.38). Overall, calculation of TcTU is an accurate diagnostic test, but also appears to be the best parameter to predict the functional volume and metabolic activity of the feline adenomatous thyroid gland.  相似文献   

7.
X‐ray attenuation of the liver has been measured using computed tomography (CT) and reported to decrease in cats with experimentally induced hepatic lipidosis. To assess the clinical utility of this technique, medical records and noncontrast CT scans of a series of cats were retrospectively reviewed. A total of 112 cats met inclusion criteria and were stratified into three hepatic lipidosis risk groups. Group 1 cats were considered low‐risk based on no history of inappetence or weight loss, and normal serum chemistry values; Group 2 cats were considered intermediate risk based on weight loss, serum hepatic enzymes above normal limits, or reasonably controlled diabetes mellitus; and Group 3 cats were considered high risk based on poorly controlled diabetes mellitus due to hypersomatotropism. Mean CT attenuation values (Hounsfield units, HU) were measured using regions of interest placed within the liver and cranial pole of the right kidney. Hepatic and renal attenuation were weakly positively correlated with each other (r = 0.2, P = 0.03) and weakly negatively correlated with body weight (r = ?0.21, P = 0.05, and r = ?0.34, P = 0.001, respectively). Mean (SD) hepatic and renal cortical attenuation values were 70.7 (8.7) HU and 49.6 (9.2) HU for Group 1 cats, 71.4 (7.9) HU and 48.6 (9.1) HU for Group 2, and 68.9 (7.6) HU and 47.6 (7.2) HU for Group 3. There were no significant differences in hepatic or renal attenuation among groups. Findings indicated that CT measures of X‐ray attenuation in the liver and kidney may not be accurate predictors of naturally occurring hepatic lipidosis in cats.  相似文献   

8.
Hyperthyroidism is the most common feline endocrinopathy; thyroid computed tomography (CT) may improve disease detection and methimazole dose selection. Objectives of this experimental pre‐post with historical case‐control study were to perform thyroid CT imaging in awake or mildly sedated hyperthyroid cats, compare thyroid gland CT appearance in euthyroid and hyperthyroid cats pre‐ and postmethimazole treatment, and determine whether thyroid size or attenuation correlate with methimazole dose needed for euthyroidism. Premethimazole treatment, eight hyperthyroid cats received CT scans from the head to heart, which were compared to CT of seven euthyroid cats. Total thyroxine levels were monitored every 3–4 weeks. Postmethimazole CT was performed 30 days after achieving euthyroid status. Computed tomography parameters recorded included thyroid length, width, height, attenuation, and heterogeneity. Median time between CT was 70 days (53–213 days). Mild sedation was needed in five hyperthyroid cats premethimazole, and none postmethimazole. Thyroid volume was significantly larger in hyperthyroid cats compared to euthyroid cats (785.0 mm3 vs. 154.9 mm3; P = 0.002) and remained unchanged by methimazole treatment (?4.5 mm3; P = 0.50). Thyroid attenuation and heterogeneity decreased with methimazole treatment (96.1 HU vs. 85.9 HU; P = 0.02. 12.4 HU vs. 8.1 HU; P = 0.009). Methimazole dose ranged from 2.5 to 10 mg daily with a positive correlation between pretreatment thyroid gland volume and dose needed to achieve euthyroidism (P = 0.03). Euthyroid and hyperthyroid cats are easily imaged awake or mildly sedated with CT. Methimazole in hyperthyroid cats significantly lowers thyroid attenuation and heterogeneity, but not size.  相似文献   

9.
The aims of this study were to evaluate left atrial size in cats with acute left‐sided congestive heart failure. We hypothesized that left atrial size as determined by thoracic radiography can be normal in cats with acute left‐sided congestive heart failure. One hundred cats with acute left‐sided congestive heart failure in which thoracic radiography and echocardiography were performed within 12 h were identified. Left atrial size was evaluated using right lateral and ventrodorsal radiographs. Measurements were compared to two‐dimensional echocardiographic variables of left atrial size and left ventricular size. On echocardiography, left atrial enlargement was observed in 96% cats (subjective assessment) whereas maximum left atrial dimension was increased (>15.7 mm) in 93% cats. On radiographs left atrial enlargement (subjective assessment) was found in 48% (lateral view), 53% (ventrodorsal view), and 64% (any view) of cats whereas left atrial enlargement was absent in 36% of cats in both views. Agreement between both methods of left atrial size estimation was poor (Cohen's kappa 0.17). Receiver operating characteristic curve analysis identified a maximum echocardiographic left atrial dimension of approximately 20 mm as the best compromise (Youden index) between sensitivity and specificity in the prediction of radiographic left atrial enlargement. Left atrial enlargement as assessed by thoracic radiography may be absent in a clinically relevant number of cats with congestive heart failure. Therefore, normal left atrial size on thoracic radiographs does not rule out presence of left‐sided congestive heart failure in cats with clinical signs of respiratory distress.  相似文献   

10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号