共查询到20条相似文献,搜索用时 0 毫秒
1.
G Shan D W Stoutamire I Wengatz S J Gee B D Hammock 《Journal of agricultural and food chemistry》1999,47(5):2145-2155
A competitive enzyme-linked immunosorbent assay was developed for the detection of the pyrethroid insecticide esfenvalerate. Two haptens containing amine or propanoic acid groups on the terminal aromatic ring of the fenvalerate molecule were synthesized and coupled to carrier proteins as immunogens. Five antisera were produced and screened against eight different coating antigens. The assay that had the least interference and was the most sensitive for esfenvalerate was optimized and characterized. The I(50) for esfenvalerate was 30 +/- 6.2 microg/L, and the lower detection limit (LDL) was 3.0 +/- 1.8 microg/L. The assay was very selective. Other pyrethroid analogues and esfenvalerate metabolites tested did not cross-react significantly in this assay. To increase the sensitivity of the overall method, a C(18) sorbent-based solid-phase extraction (SPE) was used for water matrix. With this SPE step, the LDL of the overall method for esfenvalerate was 0.1 microg/L in water samples. 相似文献
2.
Development of a lateral flow colloidal gold immunoassay strip for the rapid detection of olaquindox residues 总被引:1,自引:0,他引:1
Song C Liu Q Zhi A Yang J Zhi Y Li Q Hu X Deng R Casas J Tang L Zhang G 《Journal of agricultural and food chemistry》2011,59(17):9319-9326
A rapid immunochromatographic lateral flow test strip of competitive format has been developed for the specific determination of olaquindox (OLA) residues in pig urine and muscle tissues. The sensitivity of the test strip was found to be 1.58 ± 0.27 μg/kg and 1.70 ± 0.26 μg/kg of OLA in pig urine and muscle tissues, and the lower detection limit was 0.27 ± 0.08 μg/kg and 0.31 ± 0.07 μg/kg respectively. For negative pig urine and muscle samples spiked with 4, 12, and 36 μg/kg, the recovery range was 83.0-94.0% and 78.8-87.4% and the coefficient of variation scope [CV (%)] was 3.17-7.41% and 4.66-7.64% respectively. Parallel analysis of OLA samples from pig urine and muscle tissue showed comparable results from the test strip and HPLC. Each test requires 5-8 min, and the test strip can provide a useful screening method for quantitative, semiquantitative, or qualitative detection of OLA residues. 相似文献
3.
Effect of bensulfuron-methyl (a sulfonylurea herbicide) on the soil bacterial community of a paddy soil microcosm 总被引:2,自引:0,他引:2
The effect of bensulfuron-methyl (BSM) on a soil microbial community in a model paddy microcosm was studied. Total bacterial numbers in the overlying water and surface soil were monitored for 2 months after the application of BSM at the field rate and a ten-fold field rate. Pentachlorophenol (PCP) was used for comparison. Neither chemical affected the total bacterial numbers remarkably, either in the overlying water or in the surface soil. In contrast, the nitrification potential was significantly suppressed by the BSM application. The bacterial community structure, as evaluated by the denaturing gradient gel electrophoresis (DGGE) of PCR amplification products from bacterial 16S rDNA, was unaffected by the BSM treatments over 8 weeks in the surface soil, compared with the control (no pesticide). In contrast, the surface soil exposed to PCP at a ten-fold field rate showed different patterns from the controls at 4 weeks and 8 weeks after application. The DGGE patterns of the overlying water were much more variable than those of the surface soil in any treatments. Cluster analysis showed that the BSM plots were classified within the same group as the control at 1 week after application and that the BSM and PCP plots from 2 weeks onward after application were grouped differently from the control. Of 22 clones excised from the DGGE gels, 20 clones belonged to the Proteobacteria and two belonged to the Verrucomicrobia. It was considered that the impact of BSM on the overall microbial community (total numbers, community structure of soil) was negligible, although BSM had an impact on some specific functions of the soil microbial community (nitrification) and a part of the community (overlying water). 相似文献
4.
Methylcarbamates affect acylanilide herbicide residues in soil 总被引:1,自引:0,他引:1
5.
Enzyme immunoassay for screening sulfamethazine residues in swine blood 总被引:12,自引:0,他引:12
J R Fleeker L J Lovett 《Journal of the Association of Official Analytical Chemists》1985,68(2):172-174
An enzyme immunoassay (EIA) was developed to screen for residues of sulfamethazine (SMT) and its metabolites in swine blood. Swine blood was treated with perchloric acid and centrifuged. The supernatant solution was neutralized with K2HPO4, centrifuged, and applied to a reverse phase C8 cartridge. The analytes were eluted with methanol-water (2 + 3), and the eluate was diluted and assayed. Average recoveries, using 14C-labeled compounds, were 73, 72, 61, and 62% for SMT, N4-glucosylSMT, N4-acetylSMT, and N4-desaminoSMT, respectively. Tubes coated with antibody were incubated with the eluate and an SMT-beta-galactosidase conjugate. Bound enzyme was detected with fluorogenic substrate. When blood was fortified with 0.1 ppm SMT or a molar equivalent of metabolite, the average relative response of the EIA was 100%, control blood; 61%, SMT; 66%, glucosylSMT; 60%, acetylSMT; and 77% desaminoSMT. 相似文献
6.
7.
Queffelec AL Boisdé F Larue JP Haelters JP Corbel B Thouvenot D Nodet P 《Journal of agricultural and food chemistry》2001,49(4):1675-1680
Two competitive immunoassays, a laboratory assay based on microwell plates and a field test based on the use of polystyrene tubes, have been developed for the quantification of thiram in lettuces. Concerning the laboratory assay, the calibration curve for thiram had a linear range of 11 to 90 ng/mL and a detection limit of 5 ng/mL. Precision of the assay presented coefficient of variation values <9% and the recovery of thiram from lettuce averaged 89% across the range of the immunoassay method using 30 min extraction with water/acetone (50:50, v/v). The tube-based method was developed in order that an extract of lettuce, containing thiram at the MRL (8 ppm), would be found on the linear part of the standard curve. The calibration curve for thiram has a linear range of 100 to 800 ng/mL (1.39 to 11.1 ppm in lettuce) and a detection limit of 40 ng/mL. 相似文献
8.
Development of an ELISA for the detection of the residues of the fungicide iprovalicarb 总被引:3,自引:0,他引:3
Lee JK Park SH Lee EY Kim YJ Kyung KS 《Journal of agricultural and food chemistry》2004,52(22):6680-6686
A competitive indirect enzyme-linked immunosorbent assay was developed for the fungicide iprovalicarb, using a polyclonal antibody produced against a hapten conjugated through the carboxyl group on the benzene ring to keyhole limpet hemocyanin. Under an optimized condition using a heterologous format, an IC(50) of 3.51 ng/mL and the lowest detection limit of 0.065 ng/mL were obtained. When the isopropoxy group was removed from the iprovalicarb structure for the synthesis of a hapten, the resulting hapten was not successful as an immunogen, indicating that the isopropyl moiety was an important epitope, as evidenced by the cross-reactivities of some structurally related compounds. When applied to the real crop and water samples, the recoveries were in the range of 80.52-144.70% (n = 4) and 72.11-100.43% (n = 4), respectively. Accordingly, this ELISA can be used as a useful method for monitoring iprovalicarb residues in crop and water samples. 相似文献
9.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) was used to determine photochemically cutin-bound residues of chlorothalonil in enzymatically isolated tomato and apple fruit cuticles. The samples were spiked, irradiated, exhaustively extracted, and depolymerized with boron trifluoride complex resulting in a soluble depolymerisate. With this procedure, the ELISA could be calibrated with free target molecules for the quantification of originally bound chlorothalonil residues. In fruit cuticles that were irradiated for 8 h by simulated sunlight, 0.030 and 0.068 mg/g photoinduced cutin-bound residues of wax-free cuticles (calculated as chlorothalonil) were determined for tomatoes and apples, respectively. For the used antibody mAb chl. 4/11, cross-reactivities with derivatives of chlorothalonil simulating different types of cuticle-bound residues are given and discussed. 相似文献
10.
Extraction methods for quantitation of gentamicin residues from tissues using fluorescence polarization immunoassay 总被引:1,自引:0,他引:1
S A Brown D R Newkirk R P Hunter G G Smith K Sugimoto 《Journal of the Association of Official Analytical Chemists》1990,73(3):479-483
Sodium hydroxide digestion of unhomogenized kidney and skeletal muscle for 20 min at 70 degrees C was a superior method for extracting gentamicin from tissues, compared with simple homogenization, trichloroacetic acid precipitation of homogenized tissue, and sodium hydroxide digestion of homogenized tissue. Fluorescence polarization immunoassay was used to quantitate gentamicin. Sodium hydroxide digestion of unhomogenized tissue allowed for the recovery of 90.0 +/- 5.9% (means +/- SD) from renal cortex and 79.9 +/- 3.5% from skeletal muscle. The limit of sensitivity was 17.4 ng/g kidney tissue, 15.8 ng/g digested muscle, and 39.0 ng/g digested heart. The within-assay coefficient of variation (CV) at 100 ng/g kidney was 9.2%; at 500 ng/g kidney, the CV was 2.5%; and at 2000 ng/g kidney, the CV was 1.5%. The between-assay coefficient of variation was less than 7.5% for all concentrations from kidney, and the 99% confidence interval at 100 ng/g kidney was 71.7-112.4 ng gentamicin/g kidney. The within-assay coefficient of variation (CV) at 100 ng/g muscle was 15%; at 500 ng/g muscle, the CV was 2.6%; and at 2000 ng/g muscle, the CV was 2.3%. The between-assay coefficient of variation was less than 15% for all concentrations from muscle, and the 99% confidence interval at 100 ng/g muscle was 72.5-136.8 ng gentamicin/g muscle. Gentamicin-free milk could be distinguished from milk containing gentamicin concentrations of 10 ng/mL milk with 95% confidence, and from milk containing concentrations of 30 ng gentamicin/mL milk with 99% confidence. Quantitative results at or below the tolerance level can be obtained within 90 min of sample acquisition using these extraction and assay methods. 相似文献
11.
12.
Xu T Shao XL Li QX Keum YS Jing HY Sheng W Li J 《Journal of agricultural and food chemistry》2007,55(10):3764-3770
A competitive enzyme-linked immunosorbent assay (ELISA) for pentachloronitrobenzene (PCNB), a fungicide and chemical intermediate, was developed using a polyclonal antiserum produced against a hapten-protein conjugate of pentachlorophenoxypropionic acid-bovine serum albumin (BSA). An indirect competitive ELISA of PCNB showed an IC50 of 37 ng/mL and a limit of detection (LOD) of 7 ng/mL. The ELISA can tolerate up to 10% (v/v) methanol, 5% (v/v) acetonitrile, or 5% (v/v) acetone without significant fluctuation of Amax and IC50. The assay sensitivity showed little change in a range of pH from 6 to 8 and concentrations of 0.05-0.2 M NaCl in the assay buffer. Very low cross-reactivities were observed for some structurally related compounds except for hexachlorobenzene (12%). The average recoveries of PCNB from fortified well water, river water, and soil samples were in ranges of 88-94, 80-91, and 70-81%, respectively. The correlations between the gas chromatographic and ELISA results were excellent (r 2 >or= 0.97, slopes from 0.86 to 1.10) for those fortified samples. The ELISA is a good alternative tool for monitoring PCNB residues in environmental samples. 相似文献
13.
Zhao J Yi GX He SP Wang BM Yu CX Li G Zhai ZX Li ZH Li QX 《Journal of agricultural and food chemistry》2006,54(14):4948-4953
Hybridomas secreting a monoclonal antibody (mAb) against the herbicide chlorimuron-ethyl (CE) were produced by fusing the mouse myeloma cell line (SP2/0) with splenocytes from a mouse immunized against the conjugate of the sulfonamide moiety of CE and bovine serum albumin (BSA). The mAb, designated 1F5C5A10, had very weak affinity with metsulfuron, ethametsulfuron, pyrazosulfuron, bensulfuron, and chlorsulfuron. Two mAb-based indirect competitive enzyme-linked immunosorbent assays (icELISA) were developed. A conventional icELISA (icELISA-I) showed a concentration of half-maximum inhibition (IC(50)) of 11.6 ng/mL with a dynamic range of 1.6-84 ng/mL. A simplified icELISA (icELISA-II) had an IC(50) of 28.7 ng/mL and a dynamic range of 2.2-372 ng/mL. The two assays were tested on spiked water and soil samples. CE (1-500 ng/mL) fortified in water samples could be analyzed directly without any sample preparation by both immunoassays with an average recovery between 74 and 114%. icELISA-II, but not icELISA-I, was able to accurately analyze the herbicide residues in the crude soil extracts with recoveries between 99 and 129% without obvious matrix effects due to its lesser amount of sample used. In contrast to icELISA-I, icELISA-II is more convenient, whereas it consumes more reagents of coating antigen and goat anti-mouse IgG-peroxidase. 相似文献
14.
Development and validation of an ultrasensitive chemiluminescent enzyme immunoassay for aflatoxin M1 in milk 总被引:1,自引:0,他引:1
Magliulo M Mirasoli M Simoni P Lelli R Portanti O Roda A 《Journal of agricultural and food chemistry》2005,53(9):3300-3305
A fast and ultrasensitive chemiluminescent enzyme immunoassay for aflatoxin M(1) in milk samples has been developed and validated. The method is an indirect competitive type format involving the immobilization of an aflatoxin M(1)-bovine serum albumin conjugate on 384 well black polystyrene microtiter plates and the use of a secondary antibody labeled with horseradish peroxidase detected with a luminol-based substrate. Aflatoxin M(1) standard solutions were prepared in milk-based buffer, and milk samples were analyzed without any cleanup procedure. The limit of quantification was 1 ppt, the coefficient of variation was below 9% for both intra- and interassay precision, and the recovery ranged from 96 to 122%. The method is specific, and other aflatoxins do not significantly cross-react with the antibody. Twenty-four milk samples were analyzed, and a good correlation was observed (y = 0.98x + 1.71, r(2) = 0.98, n = 24) when the data were compared with a reference high-performance liquid chromatography method with a fluorescent detector. The developed method is suitable for an accurate, sensitive, and high-throughput screening of aflatoxin M(1) in milk samples with a reduction of costs and increased detectability, as compared with previously developed immunoassays. 相似文献
15.
Development and validation of an optical SPR biosensor assay for tylosin residues in honey 总被引:3,自引:0,他引:3
Caldow M Stead SL Day J Sharman M Situ C Elliott C 《Journal of agricultural and food chemistry》2005,53(19):7367-7370
In recent years there has been an increase in the use of tylosin in apiculture as bacterial brood diseases become resistant to oxytetracycline. Confirmatory mass spectrometry based methods have been developed but up until now there has been no complementary screening method available capable of sub 10 microg kg(-1) detection limits. In this paper the development and validation of a screening method using optical biosensor technology is presented. The honey was first dissolved in a phosphate buffer and following solid-phase extraction (SPE) cleanup was analyzed using a Biacore Q instrument. Using the criteria specified in European Commission Decision 2002/657/EC for qualitative screening methods, the detection capability (CCbeta) of the method was determined to be 2.5 microg kg(-)(1). Honey samples containing trace residue levels of tylosin were analyzed by both the biosensor screening method and a LC-MS/MS confirmatory procedure; the results were in good agreement. 相似文献
16.
Development of an indirect competitive ELISA for ciprofloxacin residues in food animal edible tissues 总被引:16,自引:0,他引:16
An indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed to detect ciprofloxacin (CPFX) in food animal edible tissues. CPFX was converted by an active ester method into conjugates CPFX-bovine serum albumin (CPFX-BSA) and CPFX-human serum albumin (CPFX-HSA), which both allowed production of CPFX-specific rabbit antisera. In the ELISA, CPFX-HSA was coated onto the microtiter plate, followed by incubation with standard CPFX and anti-CPFX antibody. The indirect competitive ELISA revealed that the antisera have no cross-reactivity with penicillin, gentamicin, neomycin, sulfadiazine, and chlortetracycline. The antisera cross-reacted with enrofloxacin and norfloxacin about 69.8 and 44.6% as much as they did with CPFX. This ELISA was highly sensitive (0.32 ng/mL) to CPFX determination. Recovery of CPFX at 40 microg/kg was 75.58% in pork, 81.29% in chicken, and 84.30% in milk. The coefficients of variation varied from 3.7 to 9.2% over the range of CPFX concentrations studied. The linear detection range was between 1.6 and 1000 ng/mL. The results suggest that this ELISA is a specific, accurate, and convenient method for the detection of CPFX residues in food animal edible tissues. 相似文献
17.
Development of an ELISA for the detection of the residues of the insecticide imidacloprid in agricultural and environmental samples 总被引:3,自引:0,他引:3
Lee JK Ahn KC Park OS Kang SY Hammock BD 《Journal of agricultural and food chemistry》2001,49(5):2159-2167
A competitive enzyme-linked immunosorbent assay (ELISA) for the chloronicotinyl insecticide imidacloprid was developed using a polyclonal antibody produced against a hapten conjugated through the imidazolidine to keyhole limpet hemocyanin. In the standard curve of imidacloprid, an IC(50) of 17.3 ng/mL was obtained using a competitive heterologous system at pH 10. Very low cross-reactivity was found for some structurally related compounds including the insecticide thiacloprid. The high cross-reactivity with a metabolite containing the carbonyl group in the imidazolidine moiety suggests the involvement of its polarity and stereochemical fitness in forming the antibody--antigen complex. The effects of various assay conditions, including organic solvents, detergent content, salt concentration, and pH on the sensitivity were evaluated. High-performance liquid chromatography was run for comparison to validate the ELISA with fortified water samples, the correlation being 0.997-0.998 (n = 15) with a slope of 1.10--1.38. The ELISA turned out to be a convenient tool for monitoring imidacloprid residues in agricultural and environmental samples. 相似文献
18.
Capillary column gas chromatographic determination of trace residues of the herbicide chlorsulfuron in agricultural runoff water 总被引:1,自引:0,他引:1
I Ahmad 《Journal of the Association of Official Analytical Chemists》1987,70(4):745-748
A capillary column gas chromatographic method is described for determining parts-per-trillion (ppt) levels of chlorsulfuron in agricultural runoff water. The water sample is acidified with acetic acid and extracted with methylene chloride. The chlorsulfuron in the extracts derivatized to its monomethyl derivative. After Florisil column cleanup, the methylated chlorsulfuron is determined by electron-capture gas chromatography. Recovery of chlorsulfuron from fortified water samples is greater than 80%. Detection limit of the method is 25 ng chlorsulfuron/L water (25 ppt). There are 2 reaction sites on the chlorsulfuron molecule, both of which are susceptible to methylation leading to monomethyl chlorsulfuron and dimethyl chlorsulfuron. A procedure is described to methylate selectively the sulfonamide nitrogen of chlorsulfuron. 相似文献
19.
Development of a monoclonal immunoassay selective for chlorinated cyclodiene insecticides 总被引:3,自引:0,他引:3
Manclús JJ Abad A Lebedev MY Mojarrad F Micková B Mercader JV Primo J Miranda MA Montoya A 《Journal of agricultural and food chemistry》2004,52(10):2776-2784
Organochlorine pesticides still generate public health concerns because of their unresolved health impact and their persistence in living beings, which is demanding appropriate analytical techniques for their monitoring. In this study, an enzyme-linked immunosorbent assay based on monoclonal antibodies (MAbs) for the detection of an important group of organochlorine pesticides, the cyclodiene group, has been developed. With this aim, several hapten-protein conjugates, characterized by exposure of the common hexachlorinated bicyclic (norbornene) moiety and differing in the linking structure to the carrier protein, were prepared. From mice immunized with these conjugates, several MAbs with the ability to sensitively bind the majority of cyclodienes were obtained. Among them CCD2.2 MAb displaying the broadest recognition to cyclodiene compounds (endosulfan, dieldrin, endrin, chlordane, heptachlor, aldrin, toxaphene: I(50) values in the 6-25 nM range) was selected for the assay. Interestingly, this MAb showed certain stereospecificity toward other polychlorinated cycloalkanes because the gamma-isomer of hexachlorocyclohexane (lindane) was also very well recognized (I(50) value of 22 nM). This immunoassay is potentially a very valuable analytical tool for the rapid and sensitive determination of cyclodiene insecticides and related compounds, which in turn may contribute to the understanding of the biological activities and of the overall environmental impact of these persistent organic pollutants. 相似文献
20.
Development and comparison of three diagnostic immunoassay formats for the detection of azoxystrobin 总被引:1,自引:0,他引:1
The currently accepted method of detection for azoxystrobin, a strobilurin fungicide, involves a labor-intensive organic solvent extraction and gas chromatography analysis. Three diagnostic assay formats, i.e., enzyme-linked immunosorbent assay (ELISA), fluorescence polarization (FP), and time-resolved fluorescence (TR-FIA), were developed and compared with regard to detection and quantification of azoxystrobin in grape extract and river, lake, and well water samples. These three assay formats require no initial sample extraction and were not affected by any of the environmental matrices tested, and each had a linear working range of 0-400 pg/mL. The polyclonal antibodies used for each of the immunoassays were specific to azoxystrobin; that is, the highest cross-reactivity to other pesticides observed was 5.7%. The limits of detection of the immunoassays were similar at 3 (ELISA), 46 (FP), and 28 (TR-FIA) pg/mL, as were the respective IC50 values of 306, 252, and 244 pg/mL. Each of the three immunoassays developed was less labor-intensive and approximately 100-fold more sensitive than the gas chromatographic method. While the three formats were comparable in terms of performance, the fluorescence polarization assay was the least labor-intensive and required the least time to perform. 相似文献