首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Objective

To characterize the ocular surface parameters and determine the prevalence of ocular pathology in Shih Tzu dogs.

Animal Studied

Fifty Shih Tzu dogs (28 male, 22 female).

Procedures

Each dog underwent a complete ophthalmic examination (recording any pathology) and a series of diagnostics, allowing for a 10 min-interval between tests: intraocular pressure (IOP), blink rate, palpebral fissure length (PFL), corneal tactile sensation (CTS), Schirmer tear test and nasolacrimal reflex without (STT-1, NL-STT1) and with topical anesthesia (STT-2, NL-STT2), tear ferning, strip meniscometry test (SMT), tear film breakup time (TFBUT), and punctate fluorescein staining (PFS) of the cornea.

Results

Mean ± SD test values were as follows: IOP (17.9 ± 3.7 mmHg), blink rate (2.4 ± 1.4 blinks/min), PFL (23.8 ± 1.8 mm), CTS (1.8 ± 0.7 cm), STT-1 (22.0 ± 5.5 mm/min), NL-STT1 (24.2 ± 4.7 mm/min), STT-2 (16.9 ± 6.5 mm/min), NL-STT2 (18.5 ± 7.5 mm/min), SMT (7.5 ± 3.5 mm/5 s), TFBUT (5.3 ± 2.4 s), tear ferning (1.3 ± 0.7), and PFS (1.6 ± 0.6). PFL was significantly greater in male vs. female Shih Tzus (p< .001). Age was negatively correlated with TFBUT results (r = −0.31, p = .027). Lagophthalmos was observed in 82% eyes. Ocular surface pathology was common, including adnexal abnormalities (100% eyes with caruncular trichiasis and medial lower lid entropion) and corneal opacification (27% pigmentation, 20% fibrosis, 12% neovascularization).

Conclusions

Qualitative tear film deficiency (low TFBUT), along with several anatomical abnormalities that promote ocular irritation and reduce globe protection, together help explain the concerningly high prevalence of ocular surface disease in the Shih Tzu breed. Prophylactic measures (e.g., medial canthoplasty, topical lubrication) could be considered to improve ocular health in Shih Tzus.  相似文献   

2.
Purpose To perform selected ophthalmic diagnostic tests in healthy capuchin monkeys (Cebus apella) with the aim of establishing normal physiological reference values for this species. Methods A total of 15 healthy, capuchin monkeys were used to test most of the parameters in this investigation. Five of the 15 monkeys were used for the evaluation of normal conjunctival flora. Ages varied from 6 to 20 years of age. Selected diagnostic ocular tests were performed including Schirmer tear test (STT), tonometry using an applanation tonometer (Tonopen®), central corneal thickness (CCT) using an ultrasonic pachymeter (Sonomed, Micropach®, Model 200P+) and culture of the normal conjunctival bacterial flora. Results and discussion Results for selected ocular diagnostic tests investigated here for the capuchin monkey eye were as follows: IOP: 18.4 ± 3.8 mmHg; STT: 14.9 ± 5.1 mm/min; CCT: 0.46 ± 0.03 mm. No statistically significant differences between ages or genders were found for any of the results. Streptococcus sp. and Corynebacterium sp. were isolated from healthy conjunctival and eyelid margins, suggesting they are normal constituents of the conjunctival flora of the capuchin monkey. The data obtained in this investigation will help veterinary ophthalmologists and laboratory animal medicine specialists to more accurately diagnose ocular diseases in the capuchin monkey. These ophthalmic reference values will be particularly useful to diagnose discrete or unusual pathological changes of the capuchin monkey eye.  相似文献   

3.
OBJECTIVE: To develop and compare 3 techniques for retrobulbar injection of local anesthetic agents for ocular surgery and analgesia in dogs. DESIGN: Prospective study. ANIMALS: 17 dogs (including 9 cadavers). PROCEDURES: Inferior-temporal palpebral (ITP), perimandibular, and combined superior-inferior peribulbar injection techniques were compared by assessing the distribution of latex after injection into the orbits of 5 canine cadavers; magnetic resonance imaging (MRI) evaluation of the distribution of contrast agent after injection in the retrobulbar space of 4 canine cadavers; and assessment of the efficacy and MRI evaluation of the anatomic distribution of injections of a lidocainecontrast agent mixture in 4 anesthetized, nonrecovery dogs. By use of the preferred technique (ITP), the ocular effects of lidocaine anesthesia were evaluated in 4 dogs; during a 2-week period after treatment, dogs underwent ophthalmic examination, Schirmer tear testing (STT), intraocular pressure (IOP) measurement, and Cochet-Bonnet esthesiometry. RESULTS: Of the 3 techniques, the ITP technique was the preferred method for retrobulbar administration of anesthetic agent in dogs because it was efficacious (pupil dilation and central rotation of the globe achieved in all eyes), easiest to perform, and provided thorough coverage of the intraconal retrobulbar space without complication. During the 2-week follow-up period, the ITP injection did not significantly affect STT, IOP, or Cochet-Bonnet esthesiometry values in dogs. CONCLUSIONS AND CLINICAL RELEVANCE: In dogs, retrobulbar administration of anesthetic agents via the ITP technique is a potential alternative to systemic administration of neuromuscular blocking agents for ophthalmic surgery and provides the additional benefit of local ocular analgesia.  相似文献   

4.
Objective To establish reference values for the Schirmer tear test I (STT I), the phenol red thread tear test (PRTT), the intraocular pressure (IOP) with rebound tonometry, to determine the corneal sensitivity for healthy chinchillas, and to describe clinical aspects of normal chinchilla eyes. Animals One hundred and twenty‐two eyes of 61 healthy pet chinchillas of different age and gender were investigated. Procedures A full ophthalmic exam including slit lamp biomicroscopy, ophthalmoscopy, measurement of STT I, PRTT, determination of the corneal touch threshold (CTT), and the measurement of the IOP (TonoVet®) was performed. The normal appearance of the lid, the iris, the lens, the fundus, and the optic nerve disc was evaluated. Results The results of the STT I were very low and not reliable, and the measurement was discontinued. The median value of PRTT was 14.0 mm wetting/15 s (mean 14.6 ± 3.5 mm wetting/15 s). The median CTT was 32.5 mm (mean 31.2 ± 7.0 mm) respectively 1.2 g/mm2 (mean 1.5 ± 0.9 g/mm2). The median IOP was 3.0 mmHg (mean 2.9 ± 1.8 mmHg). The predominating iris color was brown. The fundus pigmentation varied. Few lens alteration were seen in otherwise healthy chinchilla eyes. Most chinchillas had myelinated discs. Optic nerve cupping was present in 62% of the animals. Conclusion Because of the small amount of tears, the PRT test is recommended for tear measurements in chinchillas. The IOP in chinchillas seems to be quiet is low in comparison to other rodents.  相似文献   

5.
Objective To estimate mean Schirmer tear test (STT) and intraocular pressure (IOP) values in healthy koalas both conscious and anesthetized. Methods Data were gathered from koalas in Victoria, Australia. Conscious examinations were performed on captive koalas. Free‐ranging (wild) koalas were examined under anesthesia. Anesthesia was induced using alfaxalone, and animals were maintained on oxygen and isoflurane if required. All animals were healthy and had no surface ocular pathology detectable during slit lamp biomicroscopy. STT I tests were performed using commercial STT test strips placed in the lower fornix for 1 min. IOP was measured using an applanation tonometer after topical anesthesia. The higher value of the two eyes for both STT and IOP was analyzed. STT was measured in 53 koalas (34 conscious, 19 anesthetized) and IOP was measured in 43 koalas (30 conscious, 13 anesthetized). A two‐sample t‐test was used to compare means. A P‐value <0.05 was regarded as significant. Mean ± SD is presented. Results The mean higher STT in conscious koalas was 10.3 ± 3.6 mm wetting/min and in anesthetized koalas it decreased to 3.8 ± 4.0 mm wetting/min (P < 0.0001). The mean higher IOP in conscious koalas was 15.3 ± 5.1 mmHg, and in anesthetized koalas it was 13.8 ± 3.4 mmHg (P = 0.32). There was no effect of sex on either STT or IOP. Conclusions The mean and SD of STT and IOP values for koalas both conscious and anesthetized were reported. The mean STT was significantly reduced by alfaxalone anesthesia.  相似文献   

6.
Objective The present study was undertaken to establish reference values for Schirmer tear test (STT) and intraocular pressure (IOP) in the long‐eared hedgehog (Hemiechinus auritus). Animals Fourteen healthy long‐eared hedgehogs (H. auritus) of either sex were studied. Procedures The hedgehogs were individually immobilized with an intramuscular injection of combined Ketamine (20 mg/kg) and Diazepam (0.5 mg/kg), and each animal underwent ophthalmic examinations including: STT, tonometry, biomicroscopy, and indirect ophthalmoscopy. Results No significant effects of animal gender, weight, side (right vs. left eye) were found in this study. Mean (SD) STT values for all eyes (n = 28) were 1.7 ± 1.2 mm/1 min with a range of 0–4 mm/1 min. Mean STT in male animals was 2.2 ± 1.2. Mean STT in female Hedgehogs was 1.3 ± 1.1. Mean (SD) IOP values by applanation tonometry were 20.1 ± 4.0 mmHg (range 11.5–26.5 mmHg). Mean (SD) IOP values by applanation tonometry were 18.2 ± 4.0 and 22.0 ± 3.2 mmHg for males and females, respectively. Conclusions This study reports STT and IOP findings in long‐eared hedgehogs (H. auritus).  相似文献   

7.

Objective

To describe normative ocular surface and aqueous tear testing data for cats of various cephalic conformation.

Animals studied

Fifty-three healthy adult cats (11 British Shorthair, 11 Burmese, 10 Devon Rex, 10 Scottish Fold, and 11 Sphynx).

Procedures

Blink rate, corneal tactile sensation (CTS), and Schirmer tear test with or without topical anesthesia (STT-1, STT-2) and with nasolacrimal stimulation (NL-STT1, NL-STT2) were assessed. Palpebral fissure length (PFL) and skull morphology were measured, and cephalic index (CI) and craniofacial ratio (CFR) calculated.

Results

Mean ± SD test results were as follows: blink rate (5.0 ± 2.3 blinks/min), CTS (3.2 ± 0.7 cm), STT-1 (11.2 ± 4.3 mm/min), STT-2 (6.7 ± 3.6 mm/min), NL-STT1 (13.4 ± 5.7 mm/min), NL-STT2 (13.5 ± 5.2 mm/min), and PFL (2.0 ± 0.2 cm). Corneal sensitivity did not differ significantly among breeds (p = .152) but was negatively correlated with body weight (r = −.32, p = .019). STT-1 significantly differed among breeds (p < .001) and was lowest in Sphynx cats (8.7 ± 4.3 mm/min). A positive correlation was detected between STT-1 values at 30 and 60 s (r = .98; p < .001). The nasolacrimal reflex significantly increased STT in anesthetized and unanesthetized eyes (approximately +100% and +20%, respectively; p ≤ .002). STT-1 tended to be higher in intact versus neutered cats (p = .062). Age did not impact any test result (p ≥ .085).

Conclusions

Normative data described here serve as a baseline for future studies assessing ocular surface disease in multiple feline breeds. Unlike dogs, brachycephalic cats did not have lower CTS or STT-1 than non-brachycephalic cats.  相似文献   

8.
9.
Objectives To establish normal reference ranges of ocular parameters including phenol read thread, palpebral fissure length, horizontal and vertical corneal diameter, upright and hanging intraocular pressure (IOP) and to report ophthalmic examination findings of the anterior segment and lens, in a population of captive fruit bats. Animals studied Eyes of 30 bats of three species were included in this study: 10 (5 males, 5 females) Malayan Flying Foxes (Pteropus vampyrus), 10 (5 males, 5 females) Little Golden‐mantled Flying Foxes (Pteropus pumilus), and 10 (4 males, 6 females) Island Flying Foxes (Pteropus hypomelanus). Results The most common ophthalmic examination findings included iris‐iris persistent pupillary membranes (83%), nuclear sclerosis (56.7%), prominent arterial circle (40%), iridal hyperpigmented foci (30%), pupillary margin cysts (27%), and third eyelid defects (20%). The mean, among all species for: phenol red thread was 20.23 ± 1.28 mm/15 s both eyes (OU); palpebral fissure length was 13.34 ± 0.33 mm for OU; for horizontal corneal diameter was 10.72 ± 0.32 mm for OU; for vertical corneal diameter was 9.90 ± 0.30 mm for OU; for the hanging intraocular pressures was 19.38 ± 0.77 mmHg for OU; for upright IOP was 13.95 ± 0.60 mmHg for OU. Measurements for the individual species groups and eyes were also calculated. Conclusions Results revealed the IOP of bats in a hanging position were significantly higher than the IOP of bats in an upright position. The size of the bat, between the species, affected palpebral fissure length, horizontal corneal diameter, and vertical corneal diameter. Information about the ocular structures and normal ophthalmic parameters for the Pteropus species is crucial for species protection because of dependence on vision for survival.  相似文献   

10.
Objective To report ophthalmic findings in the Screech owl (Megascops asio). Sample population Twenty‐three, apparently healthy adult captive Screech owls in Maryland. Procedures OU of all owls underwent complete ophthalmic examination. One randomly assigned eye of each bird was measured by phenol red thread tear test (PRT), and the other eye by Schirmer tear test (STT). TonoVet® rebound tonometry and TonoPen‐XL® applanation tonometry were performed in each eye to measure IOP. Conjunctival swabs were cultured from one eye of 10 birds, corneal diameter was measured in OU of eight birds, and streak retinoscopy was performed on OU of seven birds. Ten birds were anesthetized, and A‐scan ultrasonography using a 15‐MHz probe was performed to obtain axial intraocular measurements. Results Ophthalmic abnormalities were noted in 24/46 (52%) of eyes. Median STT result was ≤ 2 mm/min, ranging ≤ 2–6 mm/min, and mean ± SD PRT was 15 ± 4.3 mm/15 s. Mean ± SD IOP were 9 ± 1.8 mmHg TonoVet®‐P, 14 ± 2.4 mmHg TonoVet®‐D, and 11 ± 1.9 mmHg TonoPen‐XL®. Coagulase negative staphylococcal organisms were cultured from all conjunctival swabs. Mean ± SD corneal dimensions were 14.5 ± 0.5 mm vertically and 15.25 ± 0.5 mm horizontally. All refracted birds were within one diopter of emmetropia. Mean ± SD axial distance from the cornea to the anterior lens capsule was 4.03 ± 0.3 mm, from cornea to the posterior lens capsule was 10.8 ± 0.5 mm, and from cornea to sclera was 20.33 ± 0.6 mm. Conclusions This study reports ophthalmic examination findings in Screech owls, and provide means and ranges for various ocular measurements. This is the first report of rebound tonometry and PRT in owls.  相似文献   

11.
Objective To determine reference values for Schirmer tear tests I and II in clinically normal pigs. Animal studied Twenty clinically normal Landrace pigs (10 males and females) without ocular abnormalities were used in this study. Procedures In all pigs, Schirmer tear tests (STT) I and II were performed by using a sterile Schirmer tear test standardized strip (Schirmer‐Tränentest®, Germany) placed in the lower conjunctival fornix for 1 min. Results For each test (STT I and STT II), no differences were observed between the right and left eyes (P ≥ 0.5). The mean ± SD STT I value was 15.6 ± 3.7 mm/min (range, 10–22 mm/min), while the mean STT II value was 12.4 ± 3.8 mm/minute (range, 5–18 mm/min). The mean STT II value was significantly lower than the STT I level (P < 0.001). Animal gender did not have a significant effect on STT I and II values (P = 0.52). The mean ± SD STT I/II values of 10 juvenile pigs were significantly lower than the mean ± SD STT I/II values of 10 adult pigs (P < 0.001). Conclusions This study of 20 Landrace pigs provided valuable information on normal STT I/II in this species. Knowledge of normal STT reference values in pigs enables the clinician to evaluate corneal pathology and diagnose tear deficiency syndromes with greater accuracy.  相似文献   

12.
Purpose To determine the normal reference range for Schirmer tear test (STT) values in clinically normal llamas (Lama glama) Animals Nine captive llamas (Lama glama) (seven females and two males) were used in this study. Procedure Complete ophthalmic examinations were performed without chemical restraint. STT I values were evaluated in both eyes of all llamas using a commercial STT strip of a single lot number (Schirmer‐Tränentest®, Germany). STT II value was also measured in both eyes of seven female llamas. Results No statistically significant differences among ages or between right and left eyes were found for any of the results. The mean ± SD STT I of 18 eyes of nine llamas was 17.3 ± 1.1 mm/min (Range 15–19 mm/min). The mean ± SD STT II of 14 eyes of seven llamas was 15.4 ± 1.7 mm/min (Range 12.5–17.5 mm/min). A paired samples t‐test demonstrated that there was a significant difference between the STT I and II values (P = 0.001). Conclusion This study provides novel data for normal reference ranges of STT I and II values in healthy llamas. Results of this study may assist veterinarians in the diagnosis of ocular surface disease and syndromes affecting the tear film in these species.  相似文献   

13.
Ophthalmic examination findings in adult pygmy goats (Capra hicus)   总被引:1,自引:1,他引:0  
Objective To document normal ophthalmic findings and ocular abnormalities in captive adult pygmy goats. Animals studied Ten healthy adult pygmy goats (five male, five female; 5–11 years of age; 26–45 kg body mass) underwent complete ophthalmic examinations. Procedure Direct illumination, diffuse and slit‐beam biomicroscopy, indirect ophthalmoscopy, IOP measurements and Schirmer tear tests were performed. TonoVet® rebound tonometry, followed by topical application of 0.5% ophthalmic proparacaine, and Tono‐Pen XL® applanation tonometry were performed in each eye to obtain estimates of IOP. Results Ophthalmic abnormalities included corneal scars and pigmentation, incipient cataracts, lenticular sclerosis, and vitreal veiling. Mean STT values were 15.8 mm/min, with a range of 10–30 mm/min. Mean IOP values were 11.8 mmHg for TonoVet®‐D, with a range of 9–14 mmHg; 7.9 mmHg for TonoVet®‐P, with a range of 6–12 mmHg; and 10.8 mmHg for Tono‐Pen XL®, with a range of 8–14 mmHg. Conclusions Ophthalmic examination findings in adult pygmy goats, including normal means and ranges for STT and IOP measurements, using applanation and rebound tonometry, are provided.  相似文献   

14.
Infrared thermography was used to measure temperature differences of the corneal surface between nasal and temporal limbus regions and central cornea of normal dogs and dogs with keratoconjunctivitis sicca (KCS), in order to establish temperature values in normal canine eyes and in patients with decreased Schirmer tear tests (STT) values. Dogs investigated were all either patients seen at the Veterinary Teaching Hospital of Federal University of Paraná or normal dogs that belonged to the same institution. STT were performed in all eyes. A total of 40 control eyes (STT ≥15 mm/min) and 20 eyes with low STT values (STT ≤14 mm/min) were examined. The mean STT value for eyes with normal STT values was 22.9 ± 3.9 mm/min (mean ± standard deviation), and the mean STT value for eyes with low STT value was 7.2 ± 4.8 mm/min. The mean corneal temperature was significantly lower in eyes with low STT values than in control eyes (< 0.0001). The following significant correlations were found: (i) Schirmer and breakup time (BUT) (= 0.0001, = 0.5); (ii) STT values and corneal surface temperature (= 0.001, = 0.256); (iii) STT values and age (= 0.0001, = ?0.448); (iv) age and corneal surface temperature (= 0.0001, = ?0.281); and (v) BUT and corneal surface temperature (= 0.0001, = 0.36). Thermography is a method that can differentiate between eyes with normal and abnormal STT values. In the future, thermography might be incorporated as part of the ophthalmic examination and perhaps become a popular ancillary test for the diagnoses of ocular surface disorders.  相似文献   

15.
The purpose of this study was to establish normal physiologic reference values for intraocular pressure (IOP) and Schirmer tear test (STT) results in clinically normal ostriches (Struthio camelus). Twenty ostriches of both sexes, 10 juveniles (1.5-2 yr of age) and 10 adults, were included in this study. Complete ophthalmic examination was performed prior to this investigation. STT was performed by inserting a standard sterile STT strip over the ventral lid margin into the ventral conjunctival sac for 60 sec. Following the STT, IOP was measured using applanation tonometry with the Tono-Pen Vet tonometer after topical instillation of one drop of 0.5% proparacaine ophthalmic solution. The mean +/- SD and range of Tono-Pen readings of IOP for all birds was 18.8 +/- 3.5, with a range of 12-24. Mean IOP in juvenile ostriches was 19.7 +/- 3.6. Mean IOP in adult ostriches was 16.9 +/- 2.9. There was no statistically significant difference between young and adult birds (P = 0.07). The mean STT values in the present study were 16.3 +/- 2.5 mm/1 min when measurements from both eyes were averaged. Mean STT in juvenile and adult ostriches was 15.4 +/- 1.8 and 17.2 +/- 2.9 mm/1 min, respectively. There was no statistically significant difference between young and adult birds (P = 0.11). No statistically significant differences between genders were found for any of the results (P > or = 0.41). In conclusion, this study provides normal reference range values for STT and IOP in clinically healthy ostriches.  相似文献   

16.
Objective To compare the tear‐film osmolarity of normal cats and cats with conjunctivitis. Animal studied The population consisted of shelter, research, and privately owned cats. Procedures Cats were classified as normal or having conjunctivitis. An ophthalmic examination including Schirmer tear test (STT), fluorescein staining, tear‐film break‐up time (TFBUT), intraocular pressure (IOP), and slit‐lamp biomicroscopy of the anterior segment was performed. The severity of conjunctivitis was graded and assigned a numerical score. The Tear LabTM Osmolarity System was utilized to determine the tear‐film osmolarity. Unpaired t‐tests were used to compare tear‐film osmolarity, TFBUT, IOP, and STT of the two groups. Results A total of 93 cats (186 eyes) were examined. There were 37 normal cats (74 eyes) and 39 conjunctivitis cats (78 eyes). The mean age was 2.34 years. There was no statistical difference (P = 0.2065) between the median tear‐film osmolarity of normal cats (328.5 ± 17.94 mOsms/L) and conjunctivitis cats (325.0 ± 24.84 mOsms/L). Cats with conjunctivitis had an accelerated TFBUT (P < 0.0001) and lower IOPs (P < 0.0001) as compared to normal cats. No statistical difference was found between STT values (P = 0.1304). Conclusions The median tear‐film osmolarity of normal cats was 328.5 mOsms/L. Despite the accelerated TFBUT, conjunctivitis did not cause a statistically significant change in tear‐film osmolarity. The Tear LabTM Osmolarity System was easily used and well tolerated by the cats in the study.  相似文献   

17.
Objective To measure changes in the ocular and orbital blood flow velocities by color Doppler imaging (CDI) in beagles with primary open angle glaucoma as the disease progressed from early to advanced stages. Methods CDI measurements were performed periodically on 13 glaucomatous Beagles during the nontreated mild, moderate and advanced stages of POAG over the course of 4 years. CDI was performed with the dogs lightly anesthetized (butorphanol 0.1 mg/kg IV, acepromazine maleate 0.02 mg/kg IV, and atropine sulfate 0.05 mg/kg) while the CD transducer was placed directly on the cornea anesthetized with 0.5% tetracaine hydrochloride. Intraocular pressure (IOP) by pneumatonography or TonoPen XL, heart rate and mean arterial blood pressure were measured at the beginning, middle and end of each study. The ophthalmic vessels examined included: external ophthalmic arteries and veins, long and short posterior ciliary arteries, anterior ciliary arteries and veins, primary retinal arteries, and vortex veins. Recordings of each vessel included peak systolic velocity (PSV), end diastolic velocity (EDV) and time averaged velocity (TAV), and when possible the resistive index (RI) and pulsatility index (PI) were computed. Results CDI abnormalities were present before intraocular pressure exceeded the normal range. As the animals aged, and the glaucoma progressed with higher levels of IOP, significant changes occurred in nearly all vessels, and generally included a major increase in RI (P < 0.001) and an increase in the PI (P < 0.001). Mean arterial blood pressure (105 ± 18 mmHg) and heart rate (118 ± 33/min) remained reasonably constant. The IOP gradually increased as the disease progressed (early and normotensive: 19.4 ± 3.9 mmHg; moderate: 29.7 ± 2 mmHg; and advanced: 44.5 ± 6 mmHg). The ocular veins seemed most influenced early on in the disease. Late in the disease, ocular venous blood flow could not be consistently demonstrated. An increase in the PI of ocular veins occurred in the moderately and severely affected glaucomatous Beagles. As the IOP increased, there were trends of increasing resistive index and pulsatility index in most arteries, and periods of marked decreased velocities of the vortex and external ophthalmic veins in severe cases. Conclusion CDI measurements in Beagles with primary open angle glaucoma during the course of 4 years indicate easily measurable and repeatable progressive blood flow abnormalities before the elevation of IOP and, thereafter, with gradually increased levels of IOP.  相似文献   

18.
OBJECTIVE: To establish reference values for Schirmer tear tests (STT) I and II, phenol red thread (PRT) tear test and eye blink frequency, and to determine corneal sensitivity for normal guinea pigs. ANIMALS STUDIED: One hundred and eight eyes of 54 adult Duncan-Hartley guinea pigs. PROCEDURE: Schirmer tear test (STT) I and then STT II were performed in 36 guinea pigs. PRT and STT I were compared in 18 adult Duncan-Hartley guinea pigs. Corneal sensitivity was determined in 23 guinea pigs by evaluating the corneal touch threshold (CTT) of five different regions using a Cochet-Bonnet esthesiometer. Eye blink frequency was measured in 10 guinea pigs over a period of 20 min and in 17 guinea pigs over a period of 10 min. RESULTS: Mean STT I was 0.36 mm +/- 1.09 mm (wetting/min) and mean STT II was 0.43 mm +/- 1.29 mm (wetting/min). There was no significant difference between mean STT I and mean STT II (P = 0.79). The mean PRT-value was 16 +/- 4.7 mm (wetting/15 s), and the mean STT I-value in the same guinea pigs was 0.6 +/- 1.83 mm (wetting/min). Corneal sensitivity was significantly higher in the center than in the four limbal regions. The mean CTT for central, ventral, nasal, temporal and dorsal regions was 2, 1.7, 1.7, 1.7 and 1.6 cm or 3.7, 5.2, 5.6, 5.7 and 6.4 g/mm(2), respectively. Eye blink frequency was between two to five (mean 3.4 +/- 1.04) blinks per eye over 20 min in guinea pigs in their home environment, while in handheld and restrained guinea pigs eye blink frequency showed a variation between 0 and 17 blinks per eye (mean 3.24 +/- 3.64 blinks per eye) over 10 min. CONCLUSIONS: As there were no significant differences between STT I and STT II results, reflex tear secretion in the guinea pig may not exist. The most likely explanation is a lower corneal sensitivity in the guinea pig than in other species, such as cats, dogs and horses. Because of the small amount of tears, PRT is the preferred test for tear measurement in the guinea pig.  相似文献   

19.
Objective To establish a baseline range or average for tear production in normal juvenile dogs and evaluate the effects of age, weight, and gender on Schirmer tear test (STT) in juvenile dogs. Materials and methods Healthy puppies of various breeds <6 months of age. STT1 and STT2 were performed in both eyes of each subject. Statistical analysis was performed using a backwards stepwise regression model with repeated measures. Using continuous variables of STT1 and STT2 as the dependent variables separately, the independent variables were age (days), eye (left or right), gender (male or female), ocular disease processes in eyes or not, and weight (kg). Results Eighty‐six eyes from 27 males and 16 females were included in this study. Ages ranged from 25 to 133 (mean ± SEM: 61.74 ± 24.15) days and weights ranged from 0.88 to 8.86 (3.27 ± 2.22) kg. STT1 results ranged from 0 to 26 (15.76 ± 5.79) mm/min. STT2 results ranged from 0 to 24 (8.79 ± 5.01) mm/min. Age, weight, and gender significantly affected STT1 results. Weight and gender significantly affected STT2 results. STT1 values increased by 0.15 mm/min for each 1 day increase in age and by 0.84 mm/min for each 1 kg increase in body weight. STT2 values increased by 0.57 mm/min for each 1 kg increase in body weight. Conclusions Age, weight, and gender significantly affect tear production in normal juvenile dogs. STT1 increases to adult values at approximately 9–10 weeks of age.  相似文献   

20.
Objective To evaluate the effect of central corneal thickness (CCT) on the measurement of intraocular pressure (IOP) with the rebound (TonoVet®) and applanation (TonoPen XL®) tonometers in beagle dogs. Animal studied Both eyes of 60 clinically normal dogs were used. Procedures The IOP was measured by the TonoVet®, followed by the TonoPen XL® in half of the dogs, while the other half was measured in the reverse order. All CCT measurements were performed 10 min after the use of the second tonometer. Results The mean IOP value measured by the TonoVet® (16.9 ± 3.7 mmHg) was significantly higher than the TonoPen XL® (11.6 ± 2.7 mmHg; P < 0.001). The IOP values obtained by both tonometers were correlated in the regression analysis (γ2 = 0.4393, P < 0.001). Bland–Altman analysis showed that the lower and upper limits of agreement between the two devices were ?0.1 and +10.8 mmHg, respectively. The mean CCT was 549.7 ± 51.0 μm. There was a correlation between the IOP values obtained by the two tonometers and CCT readings in the regression analysis (TonoVet® : P = 0.002, TonoPen XL® : P = 0.035). The regression equation demonstrated that for every 100 μm increase in CCT, there was an elevation of 1 and 2 mmHg in IOP measured by the TonoPen XL® and TonoVet®, respectively. Conclusions The IOP obtained by the TonoVet® and TonoPen XL® would be affected by variations in the CCT. Therefore, the CCT should be considered when interpreting IOP values measured by tonometers in dogs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号