首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Evaluation of two applanation tonometers in cats.   总被引:2,自引:0,他引:2  
Comparisons of the MacKay-Marg and Tono-Pen applanation tonometers in open and closed in vitro systems were made for the eyes of cats. Both instruments significantly underestimated intraocular pressure (IOP) vs direct manometry (P less than 0.001), but in readily predictable manner, with high coefficients of determination (r2 = 0.99). For tonometer 1 (MacKay-Marg), calculated actual IOP = 1.36 x (MacKay-Marg measurement) - 1.67 mm of Hg; and for tonometer 2 (Tono-Pen), calculated actual IOP = 1.37 x (Tono-Pen measurement) + 0.8 mm of HG, using measurements from 11 enucleated eyes. In vivo comparisons were initially made in 81 clinically normal eyes (n = 41 cats) by applying the Tono-Pen first followed by the MacKay-Marg. Compared with the MacKay-Marg, the Tono-Pen significantly (P less than 0.001) underestimated IOP in these cats. When the order of tonometer applanation was subsequently reversed in 73 clinically normal eyes (n = 37 cats) the Tono-Pen again significantly (P less than 0.001) underestimated IOP, compared with the MacKay-Marg. Alterations in tonometer order did not result in significant differences in measured IOP for the MacKay-Marg when compared with itself, but Tono-Pen measurements were significantly (P less than 0.05) less when its use followed, rather than preceded, that of the MacKay-Marg. Mean (+/- SD) IOP in clinically normal cats when each tonometer was used first was 22.6 +/- 4.0 mm of Hg (range, 14 to 32 mm of Hg) for the MacKay-Marg and 19.7 +/- 5.6 mm of Hg (9 to 31 mm of Hg) for the Tono-Pen.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
Ophthalmic examination findings in adult pygmy goats (Capra hicus)   总被引:1,自引:1,他引:0  
Objective To document normal ophthalmic findings and ocular abnormalities in captive adult pygmy goats. Animals studied Ten healthy adult pygmy goats (five male, five female; 5–11 years of age; 26–45 kg body mass) underwent complete ophthalmic examinations. Procedure Direct illumination, diffuse and slit‐beam biomicroscopy, indirect ophthalmoscopy, IOP measurements and Schirmer tear tests were performed. TonoVet® rebound tonometry, followed by topical application of 0.5% ophthalmic proparacaine, and Tono‐Pen XL® applanation tonometry were performed in each eye to obtain estimates of IOP. Results Ophthalmic abnormalities included corneal scars and pigmentation, incipient cataracts, lenticular sclerosis, and vitreal veiling. Mean STT values were 15.8 mm/min, with a range of 10–30 mm/min. Mean IOP values were 11.8 mmHg for TonoVet®‐D, with a range of 9–14 mmHg; 7.9 mmHg for TonoVet®‐P, with a range of 6–12 mmHg; and 10.8 mmHg for Tono‐Pen XL®, with a range of 8–14 mmHg. Conclusions Ophthalmic examination findings in adult pygmy goats, including normal means and ranges for STT and IOP measurements, using applanation and rebound tonometry, are provided.  相似文献   

3.
Objective The present study was undertaken to establish reference values for Schirmer tear test (STT) and intraocular pressure (IOP) in the long‐eared hedgehog (Hemiechinus auritus). Animals Fourteen healthy long‐eared hedgehogs (H. auritus) of either sex were studied. Procedures The hedgehogs were individually immobilized with an intramuscular injection of combined Ketamine (20 mg/kg) and Diazepam (0.5 mg/kg), and each animal underwent ophthalmic examinations including: STT, tonometry, biomicroscopy, and indirect ophthalmoscopy. Results No significant effects of animal gender, weight, side (right vs. left eye) were found in this study. Mean (SD) STT values for all eyes (n = 28) were 1.7 ± 1.2 mm/1 min with a range of 0–4 mm/1 min. Mean STT in male animals was 2.2 ± 1.2. Mean STT in female Hedgehogs was 1.3 ± 1.1. Mean (SD) IOP values by applanation tonometry were 20.1 ± 4.0 mmHg (range 11.5–26.5 mmHg). Mean (SD) IOP values by applanation tonometry were 18.2 ± 4.0 and 22.0 ± 3.2 mmHg for males and females, respectively. Conclusions This study reports STT and IOP findings in long‐eared hedgehogs (H. auritus).  相似文献   

4.
Evaluation of two applanation tonometers in horses   总被引:1,自引:0,他引:1  
Comparisons were made of measurements obtained in horses, using 2 applanation tonometers in vivo and in vitro. In vitro comparisons indicated that although neither instrument accurately recorded intraocular pressure (IOP), compared with manometric measurements, results of both instruments indicated linear digression from manometric IOP values that could readily be corrected, thereby accurately estimating IOP in horses. For tonometer 1 (MacKay-Marg), calculated actual IOP = 1.48 - 0.9 mm of Hg; and for tonometer 2 (Tono-Pen), calculated actual IOP = 1.38 + 2.3 mm of Hg. The coefficients of determination (r2) values were markedly high (0.99 for both equations). In vivo comparisons in clinically normal horses did not reveal significant differences in measured IOP between the 2 instruments, and IOP was not altered from baseline after auriculopalpebral nerve block. Mean (+/- SD) IOP in clinically normal horses was 23.5 +/- 6.10 mm of Hg and 23.3 +/- 6.89 mm of Hg, for tonometers 1 and 2, respectively.  相似文献   

5.
Intraocular pressure (IOP) was measured in 114 eyes of 57 clinically normal dogs with 2 applanation tonometers (Tono-Pen and Mackay-Marg) and the Schiotz indentation tonometer, using the 5.5- and 7.5-g weights. Significant differences were not detected between measurements obtained with the Tono-Pen and Mackay-Marg tonometers the Mackay-Marg and Schiotz tonometers using either weight and conversion with the human calibration table, or the Tono-Pen and Schiotz tonometers using the 7.5-g weight and the human calibration table. Values obtained by use of the Tono-Pen tonometer were significantly less (P less than 0.005) than values obtained with the Schiotz tonometer when a 5.5-g weight and the human calibration table were used, but the amount was clinically unimportant. Estimates of IOP using the Schiotz tonometer and the canine calibration table, and either the 5.5- or 7.5-g weight were clinically and significantly much higher (P less than 0.0001) than estimates obtained with the Tono-Pen, Mackay-Marg, or Schiotz tonometers, using the human calibration table and either weight. Sixty to 70% of clinically normal dogs had an IOP greater than or equal to 30 mm of Hg when Schiotz scale measurements were converted with the canine conversion table. For clinically normal dogs, the human calibration table was the most clinically useful table for converting Schiotz tonometer measurements to mm of Hg. Normal mean (+/- SD) canine readings with the Schiotz tonometer and the 5.5-g weight was 4.9 +/- 1.5 tonometer scale units (range, 2 to 11; 95% confidence interval, 1.9 to 7.9).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
Intraocular pressure (IOP) was measured in 73 eyes of 37 clinically normal cats with 2 applanation tonometers (Tono-Pen and Mackay-Marg) and the Schiotz indentation tonometer, using the 5.5- and 7.5-g weights. Statistically, the Tono-Pen tonometer underestimated IOP compared with the values obtained by use of the Mackay-Marg tonometer (P less than 0.0001) and the Schiotz tonometer, with either weight and either the human (P less than 0.01) or the canine (P less than 0.0001) calibration tables. Estimates of IOP using the human calibration table and either the 5.5- or 7.5-g weight were not significantly different from each other or from those obtained with the Mackay-Marg tonometer. Schiotz measurements obtained with either weight and converted using the canine calibration table were not only significantly (P less than 0.0001) different from each other, but were also clinically and significantly (P less than 0.0001) higher than measurements obtained with the Tono-Pen and Mackay-Marg tonometers or the Schiotz tonometer, using the human calibration table and either weight. Approximately three quarters of clinically normal cats had an IOP greater than or equal to 30 mm of Hg when Schiotz tonometer measurements were converted with the canine conversion table. The human calibration table was the most clinically useful table for converting Schiotz measurements from clinically normal feline eyes to estimates of IOP in mm of Hg. Normal mean (+/- SD) feline readings with the Schiotz tonometer and the 5.5-g weight was 3.9 +/- 1.4 tonometer scale units (range, 1.0 to 7.5; 95% confidence interval [CI], 1.1 to 6.7).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
OBJECTIVE: To establish reference values for Schirmer tear tests (STT) I and II, phenol red thread (PRT) tear test and eye blink frequency, and to determine corneal sensitivity for normal guinea pigs. ANIMALS STUDIED: One hundred and eight eyes of 54 adult Duncan-Hartley guinea pigs. PROCEDURE: Schirmer tear test (STT) I and then STT II were performed in 36 guinea pigs. PRT and STT I were compared in 18 adult Duncan-Hartley guinea pigs. Corneal sensitivity was determined in 23 guinea pigs by evaluating the corneal touch threshold (CTT) of five different regions using a Cochet-Bonnet esthesiometer. Eye blink frequency was measured in 10 guinea pigs over a period of 20 min and in 17 guinea pigs over a period of 10 min. RESULTS: Mean STT I was 0.36 mm +/- 1.09 mm (wetting/min) and mean STT II was 0.43 mm +/- 1.29 mm (wetting/min). There was no significant difference between mean STT I and mean STT II (P = 0.79). The mean PRT-value was 16 +/- 4.7 mm (wetting/15 s), and the mean STT I-value in the same guinea pigs was 0.6 +/- 1.83 mm (wetting/min). Corneal sensitivity was significantly higher in the center than in the four limbal regions. The mean CTT for central, ventral, nasal, temporal and dorsal regions was 2, 1.7, 1.7, 1.7 and 1.6 cm or 3.7, 5.2, 5.6, 5.7 and 6.4 g/mm(2), respectively. Eye blink frequency was between two to five (mean 3.4 +/- 1.04) blinks per eye over 20 min in guinea pigs in their home environment, while in handheld and restrained guinea pigs eye blink frequency showed a variation between 0 and 17 blinks per eye (mean 3.24 +/- 3.64 blinks per eye) over 10 min. CONCLUSIONS: As there were no significant differences between STT I and STT II results, reflex tear secretion in the guinea pig may not exist. The most likely explanation is a lower corneal sensitivity in the guinea pig than in other species, such as cats, dogs and horses. Because of the small amount of tears, PRT is the preferred test for tear measurement in the guinea pig.  相似文献   

8.
OBJECTIVE: To determine intraocular pressure (IOP) in cats > or = 7 years of age undergoing a routine comprehensive geriatric health examination. DESIGN: Prospective study. ANIMALS: 538 cats (1,068 eyes). PROCEDURE: IOP was measured by applanation tonometry following instillation of 0.5% proparacaine. RESULTS: Mean +/- SD IOP for all eyes was 12.3 +/- 4.0 mm Hg (range, 4 to 31 mm Hg). Mean age was 12.3 +/- 2.9 years. Intraocular pressure did not vary significantly cross-sectionally with age. However, in 78 cats, IOP was measured more than once, and follow-up measurements were significantly less than initial measurements (mean time between measurements, 9.4 +/- 3.0 months). The most useful tonometric criteria for identifying ocular abnormalities on the basis of IOP was an IOP > or = 25 mm Hg (mean + 3 SD) or a difference in IOP between eyes > or = 12 mm Hg. Eight cats met these criteria, and 5 of these cats had ophthalmic abnormalities. Low IOP was a nonspecific indicator of the presence of ocular abnormalities, as 111 cats had an IOP < or = 8 mm Hg, but only 2 had uveitis. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that IOP measurements can be a useful addition to a comprehensive geriatric health examination in cats > or = 7 years of age, especially when combined with an ophthalmic examination. Cats without ocular abnormalities that have lOP > or = 25 mm Hg or a > or = 12 mm Hg difference in IOP between eyes should have tonometry repeated or be referred to an ophthalmologist for further evaluation before beginning antiglaucoma treatment.  相似文献   

9.
OBJECTIVE-To report values for tear production, central corneal touch threshold (CTT), and intraocular pressure (IOP) in healthy guinea pigs and determine results of aerobic bacterial culture and cytologic examination of conjunctival swab specimens. DESIGN-Cross-sectional study. ANIMALS-31 Healthy guinea pigs (62 eyes) of various ages and breeds. PROCEDURES-Tear production was measured by the phenol red thread tear test (PRT) and Schirmer tear test (STT) before and after topical anesthetic application, CTT was measured with an esthesiometer, and IOP was measured by applanation tonometry. RESULTS-Combining data from all eyes, mean +/- SD PRT values before and after topical anesthetic administration were 21.26 +/- 4.19 mm/15 s and 22.47 +/- 3.31 mm/15 s, respectively, and mean IOP was 18.27 +/- 4.55 mm Hg. Median STT values before and after topical anesthetic administration were 3 mm/min (range, 0 to 12 mm/min) and 4 mm/min (range, 0 to 11 mm/min), respectively, and median CTT was 2.0 cm (range, 0.5 to 3.0 cm). Values did not differ between eyes for any test, but significant differences were identified for PRT values between males and females and between values obtained before and after topical anesthetic administration. Common bacterial isolates included Corynebacterium spp, Streptococcus spp, and Staphylococcus spp. Cytologic examination of conjunctival swab specimens revealed mainly basal epithelial cells; lymphocytes were common. CONCLUSIONS AND CLINICAL RELEVANCE-Results provided information on values for PRT, STT, CTT, and IOP in healthy guinea pigs and on expected findings for aerobic bacterial culture and cytologic examination of conjunctival swab specimens.  相似文献   

10.
OBJECTIVE: To evaluate, for clinically normal dogs, results of Schirmer tear tests in eyes without topical anesthetic (STT) and to detect differences associated with breed, sex, age, day, and time of day in eyes in which STT was performed after use of topical anesthetic (STTa). ANIMALS: 41 Beagles, 43 Labrador Retrievers, 25 Golden Retrievers, 26 English Springer Spaniels, and 22 Shetland Sheepdogs. PROCEDURE: Beagles had STT and STTa values measured twice daily for 5 days. Client-owned dogs of 4 other breeds had STT and STTa values measured once. RESULTS: Mean +/- SD values of Beagles for STT and STTa were 20.2 +/- 2.5 and 3.8 +/- 2.7 mm/min. Mean values for STT and STTa were as follows: Labrador Retriever, 22.9 +/- 4.1 and 9.6 +/- 3.8 mm/min; English Springer Spaniel; 20.7 +/- 3.2 and 5.4 +/- 3.4 mm/min; Golden Retriever, 21.8 + 3.7 and 8.8 +/- 3.1 mm/min; and Shetland Sheepdog, 15.8 +/- 1.8 and 3.6 +/- 2.8 mm/min. Overall mean values for STT and STTa were 20.2 +/- 3.0 and 6.2 +/- 3.1 mm/min. Differences for STT and STTa were detected among breeds, but significant differences were not associated with sex or age within each breed or in overall values for all dogs. CONCLUSIONS AND CLINICAL RELEVANCE: Results for the STT reported here compare favorably with reported values, except for results of Shetland Sheepdogs; however, results for the STTa differ dramatically from reported values. Clinicians should consider effects attributable to breed when evaluating results of STT and STTa in dogs.  相似文献   

11.
12.
The objectives of this study were: (i) to determine tear film breakup times (BUTs) in young healthy cats; (ii) to determine tear film BUTs in feline eyes within 8-20 h following general anesthesia; (iii) to determine if tear film BUTs vary significantly preoperatively when compared with values obtained 8-20 h postoperatively; (iv) to determine if Schirmer tear test (STT) values correlate with tear film BUTs in young healthy cats; and (v) to determine if the isolation of particular etiologic agents from conjunctival swabs of healthy cats affects tear film BUTs. We studied eighteen healthy Domestic Short-haired (n=14) and Domestic Long-haired (n=4) cats, with normal ocular examinations, ranging in age from 0.5 to 3 years. Complete ophthalmic examinations, including tear film BUTs, were performed on all cats. Conjunctival swabs from each eye of all cats and blood samples from all cats were collected and submitted for polymerase chain reaction screening for feline herpes virus, Chlamydophila felis, Mycoplasma spp., and calicivirus. In 10 of 18 cats, STT values and tear film BUTs were measured before general anesthesia was administered and again within 8-20 h following the end of anesthesia. Mean preanesthesia tear film BUTs for all 18 cats were 17.4+/-4.6 s OD and 16.0+/-4.5 s OS. Mean postanesthesia tear film BUT results were 12.5+/-4.3 and 13.1+/-4.0 s OD and OS, respectively. Postanesthesia tear film BUTs were significantly more rapid than those measured before anesthesia (OD only). There was also a positive correlation, both before and after anesthesia, between STT values in both eyes (OU) and tear film BUTs OU. The isolation or lack of isolation of conjunctival microorganisms using PCR did not significantly affect tear film BUTs. Mean tear film BUT in young healthy domestic cats is 16.7+/-4.5 s. Tear BUT is positively correlated with STT values. Although mean tear film BUTs OD at 8-20 h following anesthesia were more rapid than preanesthesia values, this difference did not appear clinically relevant.  相似文献   

13.
Objective To compare the tear‐film osmolarity of normal cats and cats with conjunctivitis. Animal studied The population consisted of shelter, research, and privately owned cats. Procedures Cats were classified as normal or having conjunctivitis. An ophthalmic examination including Schirmer tear test (STT), fluorescein staining, tear‐film break‐up time (TFBUT), intraocular pressure (IOP), and slit‐lamp biomicroscopy of the anterior segment was performed. The severity of conjunctivitis was graded and assigned a numerical score. The Tear LabTM Osmolarity System was utilized to determine the tear‐film osmolarity. Unpaired t‐tests were used to compare tear‐film osmolarity, TFBUT, IOP, and STT of the two groups. Results A total of 93 cats (186 eyes) were examined. There were 37 normal cats (74 eyes) and 39 conjunctivitis cats (78 eyes). The mean age was 2.34 years. There was no statistical difference (P = 0.2065) between the median tear‐film osmolarity of normal cats (328.5 ± 17.94 mOsms/L) and conjunctivitis cats (325.0 ± 24.84 mOsms/L). Cats with conjunctivitis had an accelerated TFBUT (P < 0.0001) and lower IOPs (P < 0.0001) as compared to normal cats. No statistical difference was found between STT values (P = 0.1304). Conclusions The median tear‐film osmolarity of normal cats was 328.5 mOsms/L. Despite the accelerated TFBUT, conjunctivitis did not cause a statistically significant change in tear‐film osmolarity. The Tear LabTM Osmolarity System was easily used and well tolerated by the cats in the study.  相似文献   

14.
Objective To establish reference values for the Schirmer tear test I (STT I), the phenol red thread tear test (PRTT), the intraocular pressure (IOP) with rebound tonometry, to determine the corneal sensitivity for healthy chinchillas, and to describe clinical aspects of normal chinchilla eyes. Animals One hundred and twenty‐two eyes of 61 healthy pet chinchillas of different age and gender were investigated. Procedures A full ophthalmic exam including slit lamp biomicroscopy, ophthalmoscopy, measurement of STT I, PRTT, determination of the corneal touch threshold (CTT), and the measurement of the IOP (TonoVet®) was performed. The normal appearance of the lid, the iris, the lens, the fundus, and the optic nerve disc was evaluated. Results The results of the STT I were very low and not reliable, and the measurement was discontinued. The median value of PRTT was 14.0 mm wetting/15 s (mean 14.6 ± 3.5 mm wetting/15 s). The median CTT was 32.5 mm (mean 31.2 ± 7.0 mm) respectively 1.2 g/mm2 (mean 1.5 ± 0.9 g/mm2). The median IOP was 3.0 mmHg (mean 2.9 ± 1.8 mmHg). The predominating iris color was brown. The fundus pigmentation varied. Few lens alteration were seen in otherwise healthy chinchilla eyes. Most chinchillas had myelinated discs. Optic nerve cupping was present in 62% of the animals. Conclusion Because of the small amount of tears, the PRT test is recommended for tear measurements in chinchillas. The IOP in chinchillas seems to be quiet is low in comparison to other rodents.  相似文献   

15.
Evaluation of three applanation tonometers in dogs   总被引:1,自引:0,他引:1  
The Mackay-Marg, Tono-Pen, and Challenger applanation tonometers were evaluated in vivo in 12 clinically normal eyes of 6 dogs. Tonometric measures of intraocular pressure (IOP) were compared with closed manometric IOP measurements from the anterior chamber of anesthetized dogs. The tonometers were evaluated at IOP that ranged from 5 to 100 mm of Hg. The Mackay-Marg tonometer was the most reliable instrument when evaluated at IOP from 5 to 100 mm of Hg (r2 = 0.996) and from 10 to 30 mm of Hg (r2 = 0.962). The Tono-Pen tonometer was also reliable (r2 = 0.967) over the range of IOP, but consistently overestimated IOP at lower pressures and underestimated IOP at higher pressures. The Mackay-Marg and Tono-Pen measurements were essentially linear. When evaluated from 10 to 30 mm of Hg, r2 was 0.828 for the Tono-Pen tonometer. The Challenger tonometer, although reliable over the full range of IOP (r2 = 0.965), proved to be less accurate, as indicated by lack of a good linear equation.  相似文献   

16.
Objective To determine reference values for Schirmer tear tests I and II in clinically normal pigs. Animal studied Twenty clinically normal Landrace pigs (10 males and females) without ocular abnormalities were used in this study. Procedures In all pigs, Schirmer tear tests (STT) I and II were performed by using a sterile Schirmer tear test standardized strip (Schirmer‐Tränentest®, Germany) placed in the lower conjunctival fornix for 1 min. Results For each test (STT I and STT II), no differences were observed between the right and left eyes (P ≥ 0.5). The mean ± SD STT I value was 15.6 ± 3.7 mm/min (range, 10–22 mm/min), while the mean STT II value was 12.4 ± 3.8 mm/minute (range, 5–18 mm/min). The mean STT II value was significantly lower than the STT I level (P < 0.001). Animal gender did not have a significant effect on STT I and II values (P = 0.52). The mean ± SD STT I/II values of 10 juvenile pigs were significantly lower than the mean ± SD STT I/II values of 10 adult pigs (P < 0.001). Conclusions This study of 20 Landrace pigs provided valuable information on normal STT I/II in this species. Knowledge of normal STT reference values in pigs enables the clinician to evaluate corneal pathology and diagnose tear deficiency syndromes with greater accuracy.  相似文献   

17.
Objective To estimate mean Schirmer tear test (STT) and intraocular pressure (IOP) values in healthy koalas both conscious and anesthetized. Methods Data were gathered from koalas in Victoria, Australia. Conscious examinations were performed on captive koalas. Free‐ranging (wild) koalas were examined under anesthesia. Anesthesia was induced using alfaxalone, and animals were maintained on oxygen and isoflurane if required. All animals were healthy and had no surface ocular pathology detectable during slit lamp biomicroscopy. STT I tests were performed using commercial STT test strips placed in the lower fornix for 1 min. IOP was measured using an applanation tonometer after topical anesthesia. The higher value of the two eyes for both STT and IOP was analyzed. STT was measured in 53 koalas (34 conscious, 19 anesthetized) and IOP was measured in 43 koalas (30 conscious, 13 anesthetized). A two‐sample t‐test was used to compare means. A P‐value <0.05 was regarded as significant. Mean ± SD is presented. Results The mean higher STT in conscious koalas was 10.3 ± 3.6 mm wetting/min and in anesthetized koalas it decreased to 3.8 ± 4.0 mm wetting/min (P < 0.0001). The mean higher IOP in conscious koalas was 15.3 ± 5.1 mmHg, and in anesthetized koalas it was 13.8 ± 3.4 mmHg (P = 0.32). There was no effect of sex on either STT or IOP. Conclusions The mean and SD of STT and IOP values for koalas both conscious and anesthetized were reported. The mean STT was significantly reduced by alfaxalone anesthesia.  相似文献   

18.
OBJECTIVE: To investigate the effects of age, weight, gender, and of time of day on tear production in normal dogs. ANIMALS: studied One hundred ophthalmoscopically and systemically unremarkable dogs. PROCEDURE: Schirmer tear tests (STT) were performed every 2 h during the day on one randomly chosen eye of each of 100 dogs. RESULTS: There was a statistically significant effect of time of day and age on the STT measurement. The mean STT decreased by 0.4 mm for every 1 year that age increased (P=0.007). Mean STT values taken at 10:00 am were 0.7 mm lower than values taken at 4:00 pm (P=0.04). CONCLUSIONS: Tear production decreases with age in the normal dog. In this population of dogs the largest difference was between the 10:00 am and the 4:00 pm STT measurements, but this still only amounted to 0.7 mm. This value is unlikely to be of clinical significance in the diagnosis of keratoconjunctivitis sicca (KCS).  相似文献   

19.
Purpose To determine the normal reference range for Schirmer tear test (STT) values in clinically normal llamas (Lama glama) Animals Nine captive llamas (Lama glama) (seven females and two males) were used in this study. Procedure Complete ophthalmic examinations were performed without chemical restraint. STT I values were evaluated in both eyes of all llamas using a commercial STT strip of a single lot number (Schirmer‐Tränentest®, Germany). STT II value was also measured in both eyes of seven female llamas. Results No statistically significant differences among ages or between right and left eyes were found for any of the results. The mean ± SD STT I of 18 eyes of nine llamas was 17.3 ± 1.1 mm/min (Range 15–19 mm/min). The mean ± SD STT II of 14 eyes of seven llamas was 15.4 ± 1.7 mm/min (Range 12.5–17.5 mm/min). A paired samples t‐test demonstrated that there was a significant difference between the STT I and II values (P = 0.001). Conclusion This study provides novel data for normal reference ranges of STT I and II values in healthy llamas. Results of this study may assist veterinarians in the diagnosis of ocular surface disease and syndromes affecting the tear film in these species.  相似文献   

20.
Objective To establish a baseline range or average for tear production in normal juvenile dogs and evaluate the effects of age, weight, and gender on Schirmer tear test (STT) in juvenile dogs. Materials and methods Healthy puppies of various breeds <6 months of age. STT1 and STT2 were performed in both eyes of each subject. Statistical analysis was performed using a backwards stepwise regression model with repeated measures. Using continuous variables of STT1 and STT2 as the dependent variables separately, the independent variables were age (days), eye (left or right), gender (male or female), ocular disease processes in eyes or not, and weight (kg). Results Eighty‐six eyes from 27 males and 16 females were included in this study. Ages ranged from 25 to 133 (mean ± SEM: 61.74 ± 24.15) days and weights ranged from 0.88 to 8.86 (3.27 ± 2.22) kg. STT1 results ranged from 0 to 26 (15.76 ± 5.79) mm/min. STT2 results ranged from 0 to 24 (8.79 ± 5.01) mm/min. Age, weight, and gender significantly affected STT1 results. Weight and gender significantly affected STT2 results. STT1 values increased by 0.15 mm/min for each 1 day increase in age and by 0.84 mm/min for each 1 kg increase in body weight. STT2 values increased by 0.57 mm/min for each 1 kg increase in body weight. Conclusions Age, weight, and gender significantly affect tear production in normal juvenile dogs. STT1 increases to adult values at approximately 9–10 weeks of age.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号