首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectiveTo assess agreement between oscillometric noninvasive blood pressure (NIBP) measurements using LifeWindow monitors (LW9xVet and LW6000V) and invasive blood pressure (IBP). To assess the agreement of NIBP readings using a ratio of cuff width to mid-cannon circumference of 25% and 40%.Study designProspective, randomized clinical study.AnimalsA total of 43 adult horses undergoing general anesthesia in dorsal recumbency for different procedures.MethodsAnesthetic protocols varied according to clinician preference. IBP measurement was achieved after cannulation of the facial artery and connection to an appropriately positioned transducer connected to one of two LifeWindow multiparameter monitors (models: LW6000V and LW9xVet). Accuracy of monitors was checked daily using a mercury manometer. For each horse, NIBP was measured with two cuff widths (corresponding to 25% or 40% of mid-cannon bone circumference), both connected to the same monitor, and six paired IBP/NIBP readings were recorded (at least 3 minutes between readings). NIBP values were corrected to the relative level of the xiphoid process. A Bland–Altman analysis for repeated measures was used to assess bias (NIBP–IBP) and limits of agreement (LOAs).ResultsThe 40% cuff width systolic arterial pressure [SAP; bias 7.9 mmHg, LOA –26.6 to 42.3; mean arterial pressure (MAP): bias 4.9 mmHg, LOA –28.2 to 38.0; diastolic arterial pressure (DAP): bias 4.2 mmHg, LOA –31.4 to 39.7)] performed better than the 25% cuff width (SAP: bias 26.4 mmHg, LOA –21.0 to 73.9; MAP: bias 15.7 mmHg, LOA –23.8 to 55.2; DAP: bias 10.9 mmHg, LOA –33.2 to 54.9).Conclusions and clinical relevanceUsing the LifeWindow multiparameter monitor in anesthetized horses, the 40% cuff width provided better agreement with IBP; however, both cuff sizes and both monitor models failed to meet American College of Veterinary Internal Medicine Consensus Statement Guidelines.  相似文献   

2.

Objective

To evaluate the efficacy and side effects of alfaxalone administered intramuscularly (IM) as a sedative agent in guinea pigs undergoing survey radiographs.

Study design

Prospective clinical trial.

Animals

A total of 30 client-owned guinea pigs.

Methods

Following baseline assessments, 5 mg kg?1 alfaxalone was administered IM. Heart rate, arterial haemoglobin oxygen saturation, respiratory rate, rectal body temperature, palpebral reflex, response to toe and ear pinch, righting reflex, posture, jaw tone and reaction to manipulation were assessed before and after sedation at 5-minute intervals. The time elapsed from onset of sedation to return of locomotion and coordinated limb movements, the quality of recovery and the occurrence of undesired effects were observed and recorded.

Results

The mean ± standard deviation onset of sedation was 2.7 ± 0.6 minutes. The physiological variables remained within normal ranges until completion of the procedure. Palpebral reflex and responsiveness to both ear and toe pinch were maintained during sedation. Neither hypoxaemia nor hypothermia was observed. The duration of sedation was 29.3 ± 3.2 minutes. Sedation and recovery were uneventful, and adverse effects were not observed.

Conclusions and clinical relevance

In conclusion, 5 mg kg?1 of IM alfaxalone represents a valuable sedation protocol for healthy guinea pigs undergoing minor noninvasive procedures. Further trials are required to investigate its cardiovascular effects, clinical usefulness in unhealthy patients and its combined use with analgesics for procedures associated with nociception.  相似文献   

3.
ObjectiveTo evaluate the agreement of two noninvasive blood pressure devices: a human device with the cuff placed on the wrist (Omron R1) and a veterinary device with the cuff placed on the upper brachium (Surgivet Advisor Vital Signs Monitor) with invasive blood pressure (IBP) measurement in anaesthetized chimpanzees.Study designProspective clinical study.AnimalsA convenience sample of 11 adult chimpanzees undergoing anaesthesia for translocation and routine health checks.MethodsSystolic (SAP) and diastolic arterial pressures (DAP) were continuously recorded via a transducer connected to a femoral artery cannula, and at 5 minute intervals from the two oscillometric devices. Agreement was explored using Bland-Altman analysis and bias defined as the mean difference between the two measurement methods. Spearman correlation coefficients were calculated. Significance was set at p < 0.05.ResultsBias and standard deviation for the Surgivet compared with IBP were 8.6 ± 18 for SAP and 8.4 ± 9.9 for DAP, showing a significant underestimation of both variables. Limits of agreement (LOA) were from –27 to 44 for SAP and from –11 to 28 for DAP. Correlation coefficients between the Surgivet and IBP values were 0.86 for SAP and 0.85 for DAP (p < 0.0001). Bias and standard deviation for the Omron compared with the IBP were –21 ± 25 for SAP and –18 ± 15 for DAP, showing a significant overestimation of both variables. LOA were from –70 to –28 for SAP and from –47 to 11 for DAP. Spearman correlation coefficients between the Omron and IBP values were 0.64 for SAP and 0.72 for DAP (p < 0.0001).Conclusions and clinical relevanceAlthough neither device met all the criteria for device validation, the Surgivet presented better agreement with IBP values than the Omron in adult anaesthetized chimpanzees.  相似文献   

4.
Objective This study was conducted to evaluate the performance of a new veterinary oscillometric noninvasive blood pressure (NIBP) monitor in anesthetized dogs. Study design Assessment was made to determine how closely indirect measurements were associated with direct measurements, and if there were statistically significant differences between the measurements by site. Animals Six mongrel dogs weighing 27.8 ± 2.9 kg. Methods Dogs were anesthetized with thiopental and maintained with isoflurane, which was delivered with controlled ventilation. Direct pressure measurements were obtained via a percutaneously placed arterial catheter. A range of systolic arterial pressures (SAP) were achieved by changing the isoflurane concentrations. Sites of cuff placement for indirect measurements were identified as metacarpus, metatarsus, and anterior tibial. Results At pressures below 80 mm Hg, indirect systolic measurements averaged 4 ± 3 mm Hg, higher than the direct values. At normal and high levels, indirect systolic measurements underestimated direct values by 18 ± 6 and 23 ± 6 mm Hg, respectively. Diastolic and mean pressure measurements followed the same trend, with indirect values being lower than the direct arterial pressures. Systolic, diastolic and mean arterial pressure measurements differed by cuff‐placement site. Conclusions When analyzed by site and level, indirect systolic and mean arterial blood pressures during hypotension were essentially the same as direct pressures. However, at pressures within the normal or high range, indirect measurements underestimated the direct pressures. Clinical relevance Noninvasive blood pressure measurements with a new oscillometric monitor provided an excellent means of detecting arterial hypotension in anesthetized dogs. The metatarsal site for cuff placement was slightly better than the metacarpal or anterior tibial site, considering that the regression line was closest to complete equality between the indirect and direct measurements for SAP.  相似文献   

5.
ObjectiveTo compare cardiopulmonary variables and blood gas analytes in guinea pigs (Cavia porcellus) during anesthesia with and without abdominal carbon dioxide (CO2) insufflation at intra-abdominal pressures (IAPs) 4 and 6 mmHg, with and without endotracheal intubation.Study designProspective experimental trial.AnimalsA total of six intact female Hartley guinea pigs.MethodsA crossover study with sequence randomization for IAP and intubation status was used. The animals were sedated with intramuscular midazolam (1.5 mg kg–1) and buprenorphine (0.2 mg kg–1) and anesthetized with isoflurane, and an abdominal catheter was inserted for CO2 insufflation. Animals with endotracheal intubation were mechanically ventilated and animals maintained using a facemask breathed spontaneously. After 15 minutes of insufflation, the following variables were obtained at each IAP: pulse rate, respiratory rate, rectal temperature, oxygen saturation, end-tidal CO2 (intubated only), peak inspiratory pressure (intubated only), noninvasive blood pressure and blood gas and electrolyte values, with a rest period of 5 minutes between consecutive IAPs. After 4 weeks, the procedure was repeated with the guinea pigs assigned the opposite intubation status.ResultsIntubated guinea pigs had significantly higher pH and lower partial pressure of CO2 in cranial vena cava blood (PvCO2) than nonintubated guinea pigs. An IAP of 6 mmHg resulted in a significantly higher PvCO2 (65.9 ± 19.0 mmHg; 8.8 ± 2.5 kPa) than at 0 (53.2 ± 17.2 mmHg; 7.1 ± 2.3 kPa) and 4 mmHg (52.6 ± 10.8 mmHg; 7.01 ± 1.4 kPa), mean ± standard deviation, with intubated and nonintubated animals combined.Conclusions and clinical relevanceAlthough the oral anatomy of guinea pigs makes endotracheal intubation difficult, capnoperitoneum during anesthesia induces marked hypercapnia in the absence of mechanical ventilation. An IAP of 4 mmHg should be further evaluated for laparoscopic procedures in guinea pigs because hypercapnia may be less severe than with 6 mmHg.  相似文献   

6.
Background: Guinea pigs (Cavia porcellus) are often presented as patients in veterinary practice. Nevertheless, only limited information is available about endocrine diseases or thyroxine reference values for the species. Objective: The aim of this study was to determine serum thyroxine concentrations in a well‐defined population of clinically healthy pet guinea pigs. Methods: Between October 2007 and July 2008, serum samples were collected from 40 clinically healthy guinea pigs of different sexes, ages, and breeds that were presented to our clinic for a general health check or for castration. Pregnant females were excluded from the study. Thyroxine concentration was measured using a chemiluminescence test (Immulite 2000 Canine Total T4). Results: Thyroxine concentrations ranged from 14.2 to 66.9 nmol/L (1.1–5.2 μg/dL) with a median value of 27.0 nmol/L (2.1 μg/dL). Females (n=16) had significantly (P=.039; Mann–Whitney U‐test) lower thyroxine values than castrated males (n=8), whereas no differences were found between females and intact males (n=16) or between intact and castrated males. No significant correlation was found between thyroxine concentration and age. Conclusion: This is the first report of serum thyroxine reference values for a well‐defined population of healthy pet guinea pigs as measured by a chemiluminescence assay. The results were higher than those previously reported for this species and emphasize the importance of using appropriate reference intervals for the diagnosis of hyperthyroidism.  相似文献   

7.
The aim of the study was to determine the selenium (Se) requirement of guinea pigs as a species unable to synthesize ascorbic acid. Forty-nine male guinea pigs (average weight 208 ± 3.5 g) were divided into an initial status group and six experimental groups. The animals received a Se deficient Torula yeast based basal diet (<0.02 mg Se and 26 mg α-tocopherol/kg) or a Se addition of 0.05, 0.10, 0.15, 0.20 and 0.25 mg/kg diet as sodium selenate for 10 weeks. There was no significant difference in weight gain (final weight 643 ± 21 g) between the groups and no clinical symptoms of Se deficiency occurred. With the exception of the testes, there was an increasing Se concentration in liver, plasma and haemolysate dependent on supplementation level. Glutathione peroxidase was determined in the plasma and Se dependent glutathione peroxidase (GPx1) in haemolysate, liver, kidney, heart and lung. Thioredoxin reductase (TR) activity was measured in liver, kidney and heart and deiodinase activity in the liver. A phospholipid hydroperoxide reducing activity with Se influence was determined in liver, kidney, heart, testes and brain. With the exception of GPx1 activity in heart and haemolysate and TR activity in the kidney, all enzymes already reached their maximal activity at 0.05 mg Se/kg diet. The activities of GPx1 and TR were used as parameters for broken line analysis and a Se requirement of 0.080 mg Se/kg diet was derived as sufficient for growing guinea pigs adequately supplied with vitamin E.  相似文献   

8.
This paper describes an insulinoma in 2 guinea pigs (Cavia porcellus). Both guinea pigs presented with neurologic signs and low blood glucose readings. The neurologic signs resolved with dextrose administration. Insulinoma was confirmed on postmortem examination.  相似文献   

9.
10.
Abstract   A skin lesion classified as a vascular malformation is reported in a young-adult, female guinea pig. The physical examination revealed a 3 × 2-cm irregularly shaped violaceous plaque located on the left caudal flank. The surface of the plaque was ulcerated and bled intermittently, resulting in fatal blood loss. On histology the mass consisted of variably sized vascular spaces filled with red blood cells and variable amounts of extramedullary haematopoietic cells, lined by well-differentiated endothelial cells often surrounded by one layer of spindle-shaped cells. Based on immunohistochemistry, the spindle cell population was confirmed to be smooth muscle cells and no proliferation of endothelial cells was found with the Ki67 proliferation marker. Histological and immunohistochemical findings were consistent with a vascular malformation. Classification of vascular malformations and potential treatments are discussed. To the authors' knowledge, this is the first reported case of a cutaneous vascular lesion in a guinea pig.  相似文献   

11.
AIMS: To describe a simple, minimally invasive method of ovariohysterectomy via a unilateral flank approach in guinea pigs, for use in routine desexing of healthy female guinea pigs or treatment of ovarian cysts.

METHODS: The subjects of this retrospective study were 41 client-owned guinea pigs submitted for routine desexing or treatment of ovarian cysts. They included 16 healthy female guinea pigs aged 8–12 months (Group 1), and 15 females aged from 9 months to 3 years (Group 2), and 10 females aged from 3 to 7 years (Group 3) with different-sized ovarian cysts. Prior to surgery, the animals received clinical examination, blood testing (complete blood count and serum biochemistry profile) and examination of the abdomen using ultrasonography, to assess the condition of the reproductive tract and ensure the guinea pigs were fit for surgery. Ovariohysterectomy was performed via a unilateral flank incision made close to the erector spinae muscle starting approximately 1?cm caudal to the last rib. Both ovaries, uterine horns, and the uterine cervix were localised, ligated, and dissected through this unilateral retroperitoneal incision.

RESULTS: Ovariohysterectomy was successfully completed via a single flank incision in 38/41 (93%) guinea pigs. Three guinea pigs with ovarian cysts from Group 3, which were >6 years old died during surgery due to circulatory and respiratory failure under anaesthesia. In the remaining 38 cases, surgery proceeded without complications. A further two guinea pigs from Group 3 were reluctant to move or eat for the first 3 days after surgery but recovered after provision of supportive care. All 38 animals fully recovered and wound healing was normal.

CONCLUSIONS: This is the first report of ovariohysterectomy via a unilateral flank incision in guinea pigs. This approach is a simple, minimally invasive and safe alternative to the midline or bilateral flank approaches currently used for surgery of the reproductive tract in guinea pigs.  相似文献   

12.
13.

Objective

To characterize alfaxalone administered subcutaneously (SC) in guinea pigs, both alone and in combination with dexmedetomidine and buprenorphine.

Study design

Prospective, blinded, crossover study.

Animals

A total of 15 healthy female guinea pigs weighing 400–600 g.

Methods

Alfaxalone (10, 20 and 40 mg kg?1) was administered SC to three guinea pigs as a pilot dose-finding study. Alfaxalone (20 mg kg?1; A20) was selected for comparison against combination protocols of alfaxalone (15 and 20 mg kg?1) with dexmedetomidine (0.25 mg kg?1) and buprenorphine (0.05 mg kg?1; A15DB, A20DB). Each protocol was randomly administered to 12 guinea pigs separated by ≥7 days. Time and quality of induction and recovery, heart rate, respiratory rate, peripheral hemoglobin oxygen saturation, rectal temperature, pedal withdrawal reflex and adverse effects were recorded.

Results

The median time to induction for A20, A15DB and A20DB was 6.8–8.0 minutes with no significant difference between treatments. Mean duration of recumbency for A20 was 73.6 ± 19.6 minutes. Recumbency duration for A15DB and A20DB extended to 90 minutes, at which time dexmedetomidine was antagonized using atipamezole (0.025 mg kg?1 SC). Physiological variables were within normal limits with the exception of one animal that died 45 minutes following treatment with A20DB. Pedal withdrawal reflex remained intact with all treatments. Minor side effects such as twitching or bruxism occurred sporadically with treatment A20 but not with A15DB and A20DB.

Conclusions and clinical relevance

SC alfaxalone produced uncomplicated sedation that may be recommended for nonpainful procedures that do not require complete immobility. The addition of dexmedetomidine and buprenorphine increased the duration of sedation and immobility, but did not result in general anesthesia. This combination sedation protocol may be useful for nonpainful procedures requiring extended immobility.  相似文献   

14.
ObjectiveTo use American College of Veterinary Internal Medicine (ACVIM) criteria to evaluate a high-definition oscillometric (HDO) blood pressure monitoring device versus invasive blood pressure (IBP) measurement in normotensive rabbits anaesthetized with two different anaesthetic protocols.Study designProspective experimental study.AnimalsA group of 20 healthy adult New Zealand White rabbits weighing 4.36 ± 0.37 kg (mean ± standard deviation).Materials and methodsRabbits were premedicated with butorphanol 0.5 mg kg–1 and midazolam 0.5 mg kg–1 subcutaneously (SC, group BMA) or ketamine 25 mg kg–1 and medetomidine 0.4 mg kg–1 SC (group KM). Anaesthesia was induced with alfaxalone administered intravenously (group BMA) or isoflurane by face mask (group KM) and maintained with isoflurane in oxygen. IBP was measured from the central auricular artery. The cuff for the HDO monitor was placed distal to the left elbow and distal to the left tarsus. Agreement between invasive and HDO measurements was evaluated using Bland–Altman method.ResultsIn group KM there was better agreement between the HDO device and IBP when the cuff was placed on the thoracic limb, with 100% and 91% of the readings for mean (MAP) and diastolic arterial pressure (DAP), respectively, within 10 mmHg of the IBP measurements. The agreement, although worse, also met the ACVIM criteria for systolic arterial pressure (SAP; 53% of the readings within 10 mmHg). In group BMA, the device met the criteria with the cuff on the thoracic limb only, and only for MAP and DAP (73% and 75% of the measurements within 10 mmHg of the IBP, respectively) but not for SAP (12%).Conclusion and clinical relevanceThe HDO device met most of the ACVIM criteria for noninvasive blood pressure measurement in anaesthetized rabbits, specifically when the cuff was placed distal to the elbow and the anaesthetic protocol included ketamine and medetomidine.  相似文献   

15.
16.
Objective – To determine the accuracy and precision of an oscillometric noninvasive blood pressure device as a predictor of invasive direct blood pressure in healthy anesthetized hypotensive and normotensive dogs. Design – Prospective observational study. Setting – University teaching hospital. Animals – Eight crossbred adult dogs. Interventions – Anesthesia was induced with propofol and maintained with isoflurane. A catheter was placed in the dorsal pedal artery to record systolic, mean, and diastolic arterial blood pressures (aSAP, aMAP, and aDAP, respectively). The noninvasive blood pressure device cuff was placed around the contralateral front limb to record noninvasive systolic, mean, and diastolic blood pressure (nSAP, nMAP, and nDAP). Two states of blood pressure (BP) were studied: baseline state was established by keeping end‐tidal isoflurane concentration at 1.2±0.1%. The hypotensive state was achieved by maintaining the same isoflurane concentration while withdrawing approximately 40% of the animal's blood volume until aMAP was stable at approximately 40 mm Hg. At the end of the study, blood was returned to the animal and it was allowed to recover from anesthesia. Measurements and Main Results – Agreement between the direct and indirect BP measurements was determined by the Bland‐Altman method. The SAP and MAP but not DAP bias varied significantly between each BP state. Normotensive absolute biases (mean [SD]) for SAP, MAP, and DAP were ?14.7 mm Hg (15.5 mm Hg), ?16.4 mm Hg (12.1 mm Hg), and ?14.1 mm Hg (15.8 mm Hg), respectively. Absolute biases during the hypotensive state for SAP, MAP, and DAP were ?32 mm Hg (22.6 mm Hg), ?24.2 mm Hg (19.5 mm Hg), and ?16.8 mm Hg (17.2 mm Hg), respectively. Conclusion – The oscillometric device was not reliably predictive of intra‐arterial BP during hypotension associated with acute hemorrhage.  相似文献   

17.
ObjectiveTo assess accuracy of noninvasive blood pressure (NIBP) measured by oscillometric device Sentinel compared to invasive blood pressure (IBP) in anaesthetized horses undergoing surgery. To assess if differences between the NIBP measured by the Sentinel and IBP are associated with recumbency, cuff placement, weight of the horse or acepromazine premedication and to describe usefulness of the Sentinel.Study designProspective study examining replicates of simultaneous NIBP and IBP measurements.AnimalsTwenty-nine horses.MethodsInvasive blood pressure was measured via a catheter in the facial artery, transverse facial artery or metatarsal artery. NIBP was measured using appropriate size cuffs placed on one of two metacarpal or metatarsal bones or the tail in random order. With both techniques systolic (SAP), mean (MAP), and diastolic (DAP) arterial blood pressures and heart rates (HR) were recorded. A mixed effects model compared the IBP to the NIBP values and assessed potential effects of catheter placement, localisation of the cuffs in combination with recumbency, weight of the horse or acepromazine premedication.ResultsNoninvasive blood pressure yielded higher measurements than IBP. Agreement varied with recumbency and cuff position. Estimated mean differences between the two methods decreased from SAP (lateral recumbency: range -5.3 to -56.0 mmHg; dorsal recumbency: range 0.8 to -20.7 mmHg), to MAP (lateral recumbency: range -1.8 to -19.0 mmHg; dorsal recumbency: range 13.9 to -16.4 mmHg) to DAP (lateral recumbency: range 0.5 to -6.6 mmHg; dorsal recumbency: range 21.0 to -15.5 mmHg). NIBP measurement was approximately two times more variable than IBP measurement. No significant difference between IBP and NIBP due to horse's weight or acepromazine premedication was found. In 227 of 1047 (21.7%) measurements the Sentinel did not deliver a result.Conclusion and clinical relevanceAccording to the high variability of NIBP compared to IBP, NIBP measurements as measured by the Sentinel in the manner described here are not considered as an appropriate alternative to IBP to measure blood pressure in anaesthetized horses.  相似文献   

18.
ObjectiveTo evaluate the agreement between invasive blood pressure (IBP) and Doppler ultrasound blood pressure (DUBP) using three cuff positions and oscillometric blood pressure (OBP) in anesthetized dogs.Study designProspective study.AnimalsNine adult dogs weighing 14.5–29.5 kg.MethodsThe cuff was placed above and below the tarsus, and above the carpus with the DUBP and above the carpus with the OBP monitor. Based on IBP recorded via a dorsal pedal artery catheter, conditions of low, normal, and high systolic arterial pressures [SAP (mmHg) <90, between 90 and 140, and >140, respectively] were induced by changes in isoflurane concentrations and/or dopamine administration. Mean biases ± 2 SD (limits of agreement) were determined.ResultsAt high blood pressures, regardless of cuff position, SAP determinations with the DUBP underestimated invasive SAP values by more than 20 mmHg in most instances. With the DUBP, cuff placement above the tarsus yielded better agreement with invasive SAP during low blood pressures (0.2 ± 16 mmHg). The OBP underestimated SAP during high blood pressures (?42 ± 42 mmHg) and yielded better agreement with IBP for mean (MAP) and diastolic (DAP) arterial pressure measurements [overall bias: 2 ± 15 mmHg (MAP) and 0.2 ± 16 mmHg (DAP)].ConclusionsAgreement of SAP determinations with the DUBP is poor at SAP > 140 mmHg, regardless of cuff placement. Measurement error of the DUBP with the cuff placed above the tarsus is clinically acceptable during low blood pressures. Agreement of MAP and DAP measurements with this OBP monitor compared with IBP was clinically acceptable over a wide pressure range.Clinical relevanceWith the DUBP device, placing the cuff above the tarsus allows reasonable agreement with IBP obtained via dorsal pedal artery catheterization. Only MAP and DAP provide reasonable estimates of direct blood pressure with the OBP monitor evaluated.  相似文献   

19.
ObjectiveTo determine the level of agreement between an oscillometric (O-NIBP) and an invasive method (IBP) of monitoring arterial blood pressure (ABP) in anesthetized sheep, goats, and cattle.Study designProspective clinical study.AnimalsTwenty sheep and goats, 20 cattle weighing <150 kg body weight, and 20 cattle weighing >150 kg body weight.MethodsAnimals were anesthetized and systolic ABP (SABP), mean ABP (MABP), and diastolic ABP (DABP) were measured using IBP and O-NIBP. Differences between IBP and O-NIBP, and 95% limits of agreement (LOA) between SABP, MABP, and DABP values were assessed by the Bland–Altman method.ResultsMean difference ± standard deviation (range) between SABP, DABP, and MABP measurements in sheep and goats was 0 ± 16 (-57 to 38) mmHg, 13 ± 16 (-37 to 70) mmHg, and 8 ± 13 (-34 to 54) mmHg, respectively. Mean difference between SABP, DABP, and MABP measurements in small cattle was 0 ± 19 (-37 to 37) mmHg, 6 ± 18 (-77 to 48) mmHg, and 4 ± 16 (-73 to 48) mmHg, respectively. Mean difference between SABP, DABP, and MABP measurements in large cattle was -18 ± 32 (-107 to 71) mmHg, 7 ± 29 (-112 to 63) mmHg, and -5 ± 28 (-110 to 60) mmHg, respectively. The 95% LOAs for SABP, DABP, and MABP were -31 to +31, -19 to +44, and -19 to +34 mmHg, respectively in sheep and goats; were -37 to +37, -19 to +44, and -19 to +34 mmHg, respectively in small cattle; and were -81 to +45, -50 to +63, and -59 to +50 mmHg, respectively in large cattle.ConclusionsAgreement was poor between O-NIBP and IBP monitoring techniques.Clinical relevanceArterial BP should be monitored in anesthetized sheep, goats, and cattle using IBP.  相似文献   

20.
ObjectiveTo evaluate a veterinary-specific oscillometric noninvasive blood pressure (NIBP) system according to the guidelines of the American College of Veterinary Internal Medicine (ACVIM) Consensus Statement.Study designProspective clinical study.AnimalsA total of 33 client-owned cats (20 females and 13 males).MethodsCats were premedicated with methadone (0.3 mg kg−1) and alfaxalone (2 mg kg−1) intramuscularly. After 15 minutes anesthesia was induced with isoflurane (3%) in 100% oxygen by facemask while breathing spontaneously. A 22 gauge catheter was placed in the median caudal artery and systolic (SAP), diastolic (DAP) and mean (MAP) arterial pressures were measured. NIBP measurements were collected by placing the cuff (40% of limb circumference) on the right or left antebrachium. The agreement between the two methods was evaluated with the Bland–Altman methods, and the oscillometric NIBP device was evaluated using the ACVIM guidelines for validation of devices.ResultsData from 30 of the 33 cats were analyzed. Five paired measurements were taken from each cat, totaling 150 paired measurements. Mean bias (limits of agreements) for SAP, DAP and MAP were 2.7 (−22.7 to 28.1), 0.9 (−22.3 to 24.2) and 1.3 (−20.4 to 23.0). The oscillometric NIBP passed all validation criteria, except correlation which was <0.9 for SAP, DAP and MAP.Conclusions and clinical relevanceThe Vet20 did not meet all validation criteria by the ACVIM. However, all criteria except correlation were met.  相似文献   