首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A semiautomatic method for the determination of seven N-nitrosamines in beverages by gas chromatography with nitrogen-phosphorus detection is proposed. Beverage samples are aspirated into a solid-phase extraction module for preconcentration and cleanup. The influence of the experimental conditions was examined by using various sorbents among which LiChrolut EN was found to provide quantitative elution and the highest preconcentration factors of all. The proposed method is sensitive, with limits of detection between 7 and 33 ng/kg, and precise, with relative standard deviations from 4.3% to 6.0%. The recoveries of N-nitrosamines from beverage samples spiked with 0.5 or 1 microg/kg concentrations of these compounds ranged from 95% to 102%. The method was successfully applied to the determination of residues of the studied N-nitrosamines in beverages including beer, wine, liquor, whisky, cognac, rum, vodka, grape juice, cider, tonic water, and soft drinks. The analytes were only detected in beer samples, positives being confirmed by gas chromatography coupled with impact ionization mass spectrometry.  相似文献   

2.
Five synthetic and five natural colorants were determined in lyophilized dairy products and fatty foods using an automatic method based on lixiviation and a solid-phase extraction process that includes cotton and RP-C(18) columns for the sequential retention of synthetic colorants and natural colorants, respectively. The lyophilization of the sample coupled with the separation procedure provides clean extracts despite the complexity of the matrices studied. In addition, the lyophilization process preserves the sample for at least 2 months without changes in the concentrations of the colorants. Identification and determination of synthetic and natural colorants were carried out using a liquid chromatograph equipped with a diode array detector. The detection limits achieved for all of the colorants (0.03-75 microg/g of lyophilized sample) allowed their determination within the limits established by the European Union, with good precision (approximately 4.5%). In addition, colorants spiked to different foods provided average recoveries (spiked at three concentration levels in four types of dairy samples and in three types of fatty foods) near 94 +/- 4%.  相似文献   

3.
Reported here is a simple liquid chromatographic (LC) method for the determination of riboflavin in milk (liquid, evaporated, and dry), yogurt, and cheese. The method involves passing liquid samples or filtrates of semisolid and solid samples through a C18 cartridge. Retained riboflavin is then eluted with an aliquot of 50% methanol in 0.02M acetate buffer of pH 4. A volume of the eluate is injected into the LC system consisting of a C18 column, a solvent of water-methanol-acetic acid (65 + 35 + 0.1, v/v) with a flow rate of 1 mL/min, and a UV detector set at 270 nm. The method is precise and accurate and compares favorably with the present AOAC method. Moreover, it involves fewer sample preparation steps and has a total analysis time of less than 1 h.  相似文献   

4.
About 20 pesticides were determined in lyophilized fruits using a semiautomatic multiresidue method, based on solid-phase extraction (SPE) with a silica column. The lyophilization of the sample, besides the SPE procedure selected, provided clean extracts despite the complexity of the matrixes studied. In addition, the lyophilization process allows sample preservation for at least three months without changes in the concentrations of the pesticides. Determination and quantitation of organochlorine and pyrethroid residues was carried out using a gas chromatograph equipped with an electron capture detector (GC-ECD), and a mass spectrometric detector (GC-MS) was used for confirmation purposes. Organochlorine pesticides provided average recoveries (spiked at three concentration levels in eight different fruits) near 93 +/- 4%, being lower (89 +/- 8%) for pyrethroids as a consequence of their higher degradation and interaction with the sample matrix. On the other hand, the detection limits achieved for all pesticides (0.5-8 ng per g of lyophilized fruit) allow their determination at the MRLs established by the European Union, with good precision ( approximately 5%). Finally, from the 100 different fruits screened, only 10 positive responses were obtained, which were further confirmed by GC-MS.  相似文献   

5.
A simple electrochemical approach, which does not require any expensive and complex instruments, is established for the selective and quantitative recognition of melamine in diary products and pet foods. During a preconcentration step (at 1.8 V versus Ag/AgCl), the formation of a polymer film from melamine on a preanodized screen-printed carbon electrode was identified by SEM and XPS. The as-formed polymer was found to be electroactive with a reversible redox peak, and hence square-wave voltammetry was applied to further increase the detection sensitivity to meet the detection limit for application in real sample analysis. Simply with a medium exchange procedure, melamine was selectively detected with a detection limit (S/N=3) of 0.8 μM (i.e., 98.3 ppb) by square-wave voltammetry. Lower than 1 ppm of melamine in real samples can be easily detected with good recoveries of 98.7-100.9% by the proposed approach. The recovery tests established for external calibration and standard addition techniques verified that the analysis can be done in a single-run measurement.  相似文献   

6.
Gas chromatographic determination of cholesterol in egg products   总被引:2,自引:0,他引:2  
A method has been developed for quantification of cholesterol in fresh egg yolks, spray-dried egg yolks, fresh whole eggs, and spray-dried whole eggs. The method uses saponification followed by petroleum ether extraction of cholesterol. Separation of organic and aqueous layers is enhanced by sodium chloride. Petroleum ether extracts are dried under nitrogen and redissolved in chloroform-methanol (2 + 1) for injection into a gas chromatograph. Cholesterol is separated and quantitated on a high temperature capillary column coated with 5% diphenyl and 95% dimethyl polysilicone crosslinked gum. The method was compared with the current AOAC method 17.017-17.022, and results indicated no significant difference (alpha = 0.05). However, the proposed method allowed separation and analysis of 16 samples in 7 h while the current AOAC method allowed separation and analysis of only 4 samples in 9 h.  相似文献   

7.
A method based on gas chromatography with electron capture detection was developed for the determination of ethylene dibromide (EDB) extracted from flour products. The procedure relies on the organic extraction of flour/water mixtures and uses an internal standard, 1-bromo-3-chloropropane. Recoveries of EDB at 10 and 100 ppb were 80.1 +/- 2.8% (SD) and 84.4 +/- 4.3%, respectively; recovery of the internal standard at the working concentration 500 ppb was 98.3 +/- 6.7%. Calibration curves were linear over the range 5-400 ppb, with a mean overall coefficient of variation of less than 5%. The reliability of the procedure was assessed by using gas chromatography combined with mass spectrometry. Results are shown for determination of EDB in locally milled flour products.  相似文献   

8.
A method based on matrix solid-phase dispersion (MSPD) was developed for the gas chromatographic (GC) determination of chloramphenicol (CAP) residues in animal muscle tissue. Muscle tissue was blended with octadecylsilyl-derivatized silica (C(18)). A column made from the C(18)/muscle tissue matrix was washed with n-hexane and acetonitrile/water (5 + 95), after which CAP was eluted with acetonitrile/water (50 + 50) and partitioned into ethyl acetate. The final extract was evaporated, and a trimethylsilyl derivative of CAP was prepared with Sylon HTP and detected by GC with an electron capture detector (ECD) and a mass spectrometer. For quantitation, the internal standard used was the meta isomer of CAP (m-CAP) for GC-ECD. Muscle tissue samples were fortified at three concentration levels. At 5, 10, and 15 microg/kg levels the respective mean recoveries were 93, 96, and 98%, and the repeatabilities were 13, 11, and 3%. The detection and quantitation limits with ECD were 1.6 and 4.0 microg/kg, respectively. No statistically significant difference was observed in the efficiency of CAP extraction from muscle tissue of various animals (bovine, porcine, and poultry) by the MSPD technique.  相似文献   

9.
An ultraviolet (UV) irradiation-gas-liquid chromatographic (GLC) detection procedure was used to confirm the presence of polybrominated biphenyl (PBB) residues in sample extracts after GLC quantitation. Chromatograms of PBB standard and sample extract solutions showed similar photodecomposition peak patterns dependent on time and intensity of UV irradiation. Confirmation of PBBs in sample extracts by this procedure was possible for any amount detectable by the GLC system employed. Prolonged UV irradiation resulted in complete disappearance of all PBB peaks from the chromatogram, permitting their distinction from background peaks due to extraneous sample material unaffected by UV irradiation.  相似文献   

10.
The presence of polycyclic aromatic hydrocarbons (PAHs) in coffee has been reported and is suspected to be due to the degradation of coffee compounds during the roasting step. Due to the high toxicity of these compounds, among which benzo[a]pyrene is known to be the most carcinogenic, their presence in the coffee, especially the coffee brew that is directly ingested by the consumer, is of prime importance. However, due to the low solubility of these compounds, their concentrations are expected to be rather low. As a consequence, reliable and sensitive analytical methods are required. The aim of this study was to develop a reliable and fast analytical procedure to determine these organic micropollutants in coffee brew samples. PAHs were retained on a 0.5 g polystyrene-divinylbenzene cartridge before being eluted by a mixture of methanol/tetrahydrofuran (10:90 v/v), concentrated, and directly analyzed by reversed-phase high-performance liquid chromatography coupled to a fluorescence detector. Application to the determination of PAHs in several coffee brew samples is also given, with mean estimated concentrations in the range of 0-100 ng L(-1) for suspected benzo[b]fluoranthene and benzo[a]pyrene, whereas no fluoranthene could be detected. Tentative identification was made on the basis of UV spectra. However, identification of the suspected traces of PAHs could not be achieved due to matrix effects, so that the presence of coeluting compounds may not be excluded.  相似文献   

11.
The contents of potentially toxic elements lead and cadmium and the essential element copper in various milk and dairy products consumed in Turkey were determined by differential pulse polarography (DPP), primarily to assess whether the intakes comply with recommended desired concentrations for essential and permissible levels for toxic elements. A simple and rapid DPP method has been developed for the simultaneous determination of cadmium, lead, and copper in samples. Using the differential pulse mode, half-wave peak potentials as E(1/2) were -0.58, -0.40, and -0.07 V for cadmium (Cd), lead (Pb), and copper (Cu), respectively. Marketed formulations of dairy products have been analyzed by calibration and standard addition methods. Recovery experiments were found to be quantitative. The linear domain ranges were 0.00-674.28 microg/L for Cd (R2 = 0.9999), 0.19-2.94 mg/L (p < 0.01) for Pb (R2 = 0.9997), and 0.41-133.46 microg/L for Cu (p < 0.01) (R2 = 0.9999). The studies have shown that the method is a rapid, reproducible, and accurate determination of these elements in milk and dairy products and can be used in the analysis of marketed formulations in the milk and dairy industry.  相似文献   

12.
A simple, rapid and sensitive immunogold chromatographic strip test based on a monoclonal antibody was developed for the detection of melamine (MEL) residues in raw milk, milk products and animal feed. The limit of detection was estimated to be 0.05 μg/mL in raw milk, since the detection test line on the strip test completely disappeared at this concentration. The limit of detection was 2 μg/mL (or 2 μg/g) for milk drinks, yogurt, condensed milk, cheese, and animal feed and 1 μg/g for milk powder. Sample pretreatment was simple and rapid, and the results can be obtained within 3-10 min. A parallel analysis of MEL in 52 blind raw milk samples conducted by gas chromatography-mass spectrometry showed comparable results to those obtained from the strip test. The results demonstrate that the developed method is suitable for the onsite determination of MEL residues in a large number of samples.  相似文献   

13.
A multiresidue method for the isolation and liquid chromatographic determination of oxytetracycline (OTC), tetracycline (TC), and chlortetracycline (CTC) antibiotics in milk is presented. Blank and tetracycline (OTC, TC, and CTC) fortified milk samples (0.5 mL) were blended with octadecylsilyl (C18, 40 microns, 18% load, endcapped, 2 g) derivatized silica packing material containing 0.05 g each of oxalic acid and disodium ethylenediaminetetraacetic. A column made from the C18/milk matrix was first washed with hexane (8 mL), following which the tetracyclines were eluted with ethyl acetate-acetonitrile (1 + 3; v/v). The eluate contained tetracycline analytes that were free from interfering compounds when analyzed by liquid chromatography with UV detection (photodiode array, 365 nm). Correlation coefficients of standards curves for individual tetracycline isolated from fortified samples were linear (from 0.982 +/- 0.009 to 0.996 +/- 0.004) with average percentage recoveries from 63.5 to 93.3 for the concentration range (100, 200, 400, 800, 1600, and 3200 ng/mL) examined. The inter-assay variability ranged from 8.5 +/- 2.4% to 20.7 +/- 13.0% with an intra-assay variability of 1.0-9.3%.  相似文献   

14.
A fast and reliable method for the determination of polycyclic aromatic hydrocarbons (PAHs) in water samples by solid-phase extraction (SPE) using centrifugation has been developed and optimized. A silica-based C18 cartridge was used; parameters affecting the extraction procedure such as type and volume of the elution solvent, breakthrough volume of the percolated water sample, drying of the sorbent, and evaporation of the elute have been studied. The innovation of this work was the examination of the use of a centrifugation technique in both the drying and elution steps. When combined with centrifugation, the volume of the elution solvent was reduced to 1 mL and the time for sorbent drying decreased also to 10 min under vacuum. Under optimal conditions, recoveries for the 16 U.S. EPA PAHs were between 70 and 85% and the relative standard deviation varied between 1 and 14%. Surrogate standard recoveries were similarly between 61 and 94% with a relative standard deviation between 2 and 15%. The simplicity of the described method, use of less of organic solvent, short procedure time, and good recoveries demonstrate the advantages of this environmentally friendly approach for routine analysis of numerous samples.  相似文献   

15.
16.
The results of a 5-laboratory collaborative determination of residues of the synthetic pyrethroid insecticide fenvalerate in tomato products are presented. Tomatoes from plants treated in the field at 2-4 day intervals (13 foliar applications) were processed into chopped fresh tomatoes, canned quarters, juice, paste, and the by-product skins plus seeds. Gas chromatographic analysis of the commodities for fenvalerate showed the fresh produce to contain 0.26 ppm, and the skins plus seeds contained 1.9 ppm. Residues were barely detectable in canned peeled quarters and juice, but averaged 0.12 ppm for paste, the concentration product of juice. High residues were associated with the skin content of the product. Five laboratories using modifications of the same analytical technique obtained good collaborative agreement.  相似文献   

17.
18.
A gas chromatographic/mass spectrometric (GC/MS) method for determining daminozide in high protein products has been developed. Daminozide is hydrolyzed in the presence of a strong base to form unsymmetrical dimethylhydrazine (UDMH) which is then distilled from the food matrix. A stable derivative is formed by reacting UDMH with salicyladehyde to form salicyaldehyde dimethylhydrazone. This derivative is separated and quantitated by GC/MS using selected ion monitoring (SIM) of key ions in the fragmentation pattern: m/z 164 (molecular ion of hydrazone) and m/z 120 (C7H6ON). An internal standard, 4-nitroanisole, is monitored at m/z 153 (molecular ion) and m/z 123 (C6H5O2N). The limit of detection is 0.01 ppm daminozide in a 50 g sample; however, because of variation at low levels, the limit of quantitation is 0.1 ppm. Recoveries are 90% or greater from peanuts and peanut butter spiked at the 0.1-2 ppm level. Reproducibility of the method depends on the food matrix and is 26% RSD in the worst case. Data are compared for the GC/MS method and the official EPA colorimetric procedure. Results showed a high bias in the colorimetric method, especially when roasted peanut products were analyzed.  相似文献   

19.
Electron capture (EC) gas chromatographic (GC) parameters have been developed for determining some of the more volatile industrial chemicals that can be determined by the AOAC multiresidue method for organochlorine and organophosphorus pesticides with modified GC operating conditions. Retention times relative to pentachlorobenzene are reported for 143 industrial chemicals, pesticides, and related compounds on OV-101 GC columns at 130 degrees C. Also reported for most of the compounds are recoveries from fortified samples carried through the AOAC extraction and cleanup procedures for fatty and/or nonfatty foods, Florisil elution characteristics, and GC relative retention times on mixed OV-101 + OV-210 columns at 130 degrees C. Our laboratory has used the modified EC/GC parameters with the AOAC multiresidue extraction/cleanup procedures to determine many volatile halogenated industrial chemical contaminants in foods, chiefly in samples of fresh-water fish. Other modifications of the AOAC method are described to improve the tentative identification and quantitative measurement of these volatile residues.  相似文献   

20.
Animal feeds occasionally have some degree of contamination by Aspergillus spp. Even pasteurized milk at times contains the toxic liver carcinogen aflatoxin M1 (AFM1). Confirmation of its presence is now done with solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC)-fluorescence, using a small enough sample that SPE time is reasonable. In this study 200 mL of milk was extracted using a C18 disk at a flow rate of approximately 100 mL/min and AFM1 quantified by HPLC-tandem mass spectrometry with negative electrospray ionization. The effectiveness and cleanup efficacy of immunoaffinity columns (IAC) was compared with that of Mycosep multifunctional cleanup columns (MFC). Average recovery and detection limits of whole milk and low-fat milk cleaned up by IAC were significantly superior to those obtained with the MFC (78-87% and 0.59-0.66 ng/L, respectively). The new procedure improves extraction speed, sensitivity, and specificity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号