首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An 8-week-old female Patagonian cavy was examined because of acute right hind limb lameness; radiography revealed a moderately displaced, comminuted fracture of the proximal third of the tibia. The fracture was stabilized with a hybrid external skeletal fixator. Two Kirschner wires were placed in the main proximal fragment, parallel to the tibial plateau and at right angles to each other. These wires were connected to a partial circular external fixator ring. Three half pins were placed in the distal fragment, and a straight connecting rod positioned on the medial side of the limb was connected to these pins and the fixator ring. A second connecting rod was positioned on the craniomedial side of the limb and was connected to the fixator ring and a fourth half pin in the distal fragment. The fracture healed without complications, and the fixator was removed 3 weeks after surgery. Hybrid external skeletal fixators combine the benefits of circular and linear external skeletal fixation methods, enabling rigid fixation of periarticular long bone fractures without adversely affecting mobility of the adjacent joint.  相似文献   

2.
OBJECTIVE: To determine bone healing at 20 weeks, after either static fixation (SG) or after dynamization (DG) at 4 weeks in osteotomized canine femurs repaired with an interlocking nail (ILN) secured with a type I external skeletal fixator (ESF). STUDY DESIGN: Experimental study. ANIMALS: Ten adult beagle dogs. METHODS: After mid-diaphyseal femoral osteotomy, femurs in 10 dogs were repaired with an ILN secured with 4 (2 proximal, 2 distal) threaded custom pins (TP; 2.7-mm-diameter cortical screw with a 2-mm shaft attached to the screw head) to which 2 parallel connecting bars were attached in a type I ESF configuration. In 5 dogs, dynamization was performed at 4 weeks by removing the connecting bars and 2 distal screws. Limb function, range of motion of the stifle joint (ROMSJ), radiographic evidence of bone healing, and complications were studied for 20 weeks. RESULTS: Full limb function was achieved between 8 and 10 weeks in SG dogs, but a decreased ROMSJ was observed from 5 to 8 weeks. In DG dogs, full limb function occurred between 5 and 6 weeks except in 1 dog, and ROMSJ was considered normal in all dogs. Bone healing was not affected by dynamization. Average healing time for SG was 12.8 weeks, and for DG it was 13.6 weeks. Periosteal reaction at TP insertion points, osteolysis around the thread and head of TPs were observed in both groups. A windshield-wiper effect was observed at the tip of 1 ILN. CONCLUSION: ILN locked with a type I ESF can be used for fixation of mid-shaft femoral fractures. Dynamization at 4 weeks did not affect bone healing but did prevent stifle ankylosis and promoted earlier limb function. CLINICAL RELEVANCE: ILN locked with a type I ESF is seemingly a feasible method for repair of mid-shaft femoral fractures and may decrease risk of nail failure.  相似文献   

3.
4.
CASE DESCRIPTION: A 3-year-old male alpaca was evaluated because of non-weight-bearing lameness (grade 5/5) in the left hind limb. CLINICAL FINDINGS: Clinical and radiographic examination revealed a closed, comminuted, nonarticular, displaced diaphyseal fracture of the left third and fourth metatarsal bones. TREATMENT AND OUTCOME: Initial attempts at treatment via reduction of the fracture under traction and subsequent application of a cast were unsuccessful, and more stable fracture fixation was pursued. The alpaca underwent closed reduction of the fracture, which was stabilized by the application of a 3-ring circular external skeletal fixator (CESF). Improved weight bearing on the affected limb was evident soon after surgery and gradually increased; full weight bearing was evident by the seventh day after discharge from the hospital (day 20 after application of the CESF). Lameness was hardly noticeable during walking at that time. After 3 months, complete fracture healing was evident and the CESF was removed; mild outward rotation of the distal fragment and metatarsophalangeal joint was present. A Robert Jones bandage was applied to the limb, and the alpaca was kept in a stall for another 4 weeks. Eleven months after CESF application, the owners and referring veterinarian reported that the alpaca was healthy, not lame, and serving as a stallion without apparent impediment. CLINICAL RELEVANCE: Although mostly restricted to small animals, application of a CESF can be a viable alternative for management of long bone fractures in South American camelids.  相似文献   

5.
Objective: To report use of an ulnar interlocking intramedullary nail for repair of an open highly comminuted fracture of the proximal third of the antebrachium in a dog, caused by gunshot. Study Design: Case report. Animals: 1.5‐year old, 60 kg, neutered male Mastiff. Methods: An ulnar interlocking intramedullary nail was used to stabilize an open comminuted proximal antebrachial fracture and a cast applied for 4 weeks. Results: Union by secondary bone healing occurred in 8 weeks. At 16 weeks, there was advanced remodeling of the radial and ulnar bony callus and fracture lines were no longer evident. Limb use was normal with normal pain free range of motion of the right elbow. Conclusion: Ulnar interlocking nail is a viable alternative treatment for highly comminuted fracture of the proximal third of the antebrachium in dogs.  相似文献   

6.
A 14-yr-old, 5.13-kg bald eagle (Haliaeetus leucocephalus) was hit by a car and presented to the Michigan State University Small Animal Clinic with an open, grade II, transverse, midshaft, Winquist-Hansen type-II-comminuted left tibiotarsal fracture. The fracture was reduced and fixation established with a 4.7-mm-diameter, 112-mm-long, four-hole veterinary intramedullary interlocking nail maintained in position by single 2-mm transcortical screws placed in the main proximal and distal fragments. The bird was weight bearing on the bandaged limb 48 hr postoperatively. Radiographs obtained 4 wk postoperatively revealed bridging callus over three of four cortices. The bird was released after 5 mo of rehabilitation.  相似文献   

7.
OBJECTIVE: To compare the structural properties and the interfragmentary motion in ostectomized canine femurs stabilized with either an 8-mm interlocking nail system (IN) or a 10-hole dynamic compression broad plate (DCP). ANIMAL OR SAMPLE POPULATION: Ten pairs of adult canine femurs with a 25-mm mid-diaphyseal gap. METHODS: Bone specimens were divided into 2 groups (10 femurs each). Left femurs were stabilized with a DCP and 8 bicortical screws; right femurs were stabilized with an IN and 3 screws. Mechanical tests were performed in eccentric axial loading and in craniocaudal bending. The testing was first conducted nondestructively and then until breakage. Structural properties, ie, stiffness, yield limits, and failure limits, were determined. Interfragmentary motion was measured during nondestructive tests with the use of an optoelectronic device. Axial, transverse, and rotational motions were calculated. Mean values of stiffness, yield and failure limits, and axial and shear motions for each fixation method were compared using a paired t test within each group (P <.05). RESULTS: Mean (+/-SD) values of stiffness and failure limit were significantly higher for IN constructs than for DCP constructs in compression, while there was little difference in the results between each tested group in bending. Mean yield load values were significantly higher for IN than for DCP specimens in compression as well as in bending. The axial-motion analysis revealed significant differences between IN and DCP groups during bending tests only. The highest score of transverse motion at the gap was recorded during bending tests, and was higher for DCP than for IN specimens. There were insignificant differences between the two groups with regard to rotation around the diaphyseal axis. CONCLUSIONS AND CLINICAL RELEVANCE: Structural properties and interfragmentary shear motion analysis demonstrated a much higher rigidity in the IN-bone than in the DCP-bone constructs.  相似文献   

8.
Arthrodesis of the right stifle was performed in a 21 kg German shepherd dog that had sustained a comminuted fracture of the lateral femoral condyle as a result of a gunshot wound. The arthrodesis was stabilised with a circular external skeletal fixator. A simplified technique to facilitate creation of the osteotomies of the femur and tibia, and positioning of the stifle at the desired angle, is described. Compression of the subchondral bone surfaces of the distal femur and proximal tibia was achieved using tensioned coiled transarticular Kirschner wires. Arthrodesis of the stifle was confirmed radiographically 21 weeks following surgery, and the fixator was removed. After union of the arthrodesis and removal of the fixator, the dog was fully weightbearing when standing or walking, and intermittently weightbearing or non-weightbearing at faster gaits.  相似文献   

9.
10.
Wry nose is a rare condition. The resultant deviation of the nasal septum and maxilla/premaxilla often complicates deglutition and respiration. Traditional treatment consists of internal fixation with pins after an osteotomy and a rib graft. A 17‐month‐old Arab yearling was presented for evaluation of deviation of the maxilla and nasal septum. This deviation was managed using an external fixation device after bilateral osteotomy of the maxilla/premaxilla and reduction of the deviation. Partial resection of the nasal septum by a dorsal approach was also performed. The dental malocclusion and respiratory noise were corrected.  相似文献   

11.
12.
This study was carried out on 19 dogs of different breed, age and sex. 10 different types of radius-ulna and 9 tibia fractures were treated by circular external skeletal fixator. The cases were followed by clinical and radiological controls in the postoperative period. It was observed that the cases tolerated the apparatus well. There was no looseness of fixator stability and configuration during the 15-day interval examination. Complications like pin track, serous drainage and pin loosening were observed postoperatively. It was concluded that radiographic, clinical and anatomical data together with good preoperative planning, the Ilizarov Method and circular external skeletal fixator was successful for the treatment of open or closed fragmented radius-ulna and tibia fractures in dogs.  相似文献   

13.
14.
OBJECTIVE: To compare anatomic reduction and the biomechanical properties of a circular external skeletal fixator (CESF) construct to pin and tension band wire (PTBW) fixation for the stabilization of olecranon osteotomies in dogs. STUDY DESIGN: Cadaveric study. ANIMALS: Forelimbs from 12 skeletally mature mixed-breed dogs, weighing 23 to 28 kg. METHODS: An olecranon osteotomy was stabilized with either a CESF construct or PTBW fixation. A single distractive load to failure was applied to each specimen through the triceps tendon. Osteotomy reduction and biomechanical properties were compared between fixation groups. RESULTS: Reduction was not significantly different (gap: P =.171; malalignment: P =.558) between fixation groups. Osteotomies stabilized with the CESF had greater stiffness (P <.0001) and maximum load sustained (P <.0001) compared to PTBW fixation. There was no significant difference for yield load (P =.318) or for load at 1 mm of axial displacement (P =.997) between fixation groups. Failure of fixation occurred by bending of the intramedullary Steinmann pin and the fixation wires in the CESF specimens and by untwisting of the tension band wire knot with pullout and bending of the Kirschner wires in the PTBW specimens. CONCLUSIONS: Specimens stabilized with the CESF construct had similar reduction and yield load, greater stiffness and maximum load sustained, and less elastic deformation than specimens stabilized with PTBW fixation. CLINICAL RELEVANCE: The CESF construct may provide a biomechanically favorable alternative to PTBW fixation for stabilization of olecranon osteotomies in dogs, and its application warrants clinical investigation.  相似文献   

15.
16.
Numerous techniques for surgical correction of angular limb deformities in horses involving an osteotomy of the affected bone and stabilization with an internal fixation device have been described. However, because the osteotomy typically has to be performed at the level of the physis, leaving little bone between the physis and the nearest joint, stabilizing the osteotomy by use of internal fixation devices may be difficult. In horses with severe chronic angular limb deformities, the amount of soft-tissue contracture may make it impossible to correct the deformity during a single procedure without causing stretch injuries to the adjacent tendons and neurovascular structures. Adjustable external ring fixators incorporating hinged rods on 1 side of the limb and an angular motor assembly on the other may be useful for treatment of severe chronic angular limb deformities in younger equids, because they allow for gradual correction of the deformity.  相似文献   

17.
18.
An adult Red-crowned crane in captivity that had a displaced compound fracture of the middle upper beak caused by an accident was treated by using Type I-a external skeletal fixator (ESF). The ESF that was equipped with a unilateral epoxy putty fixator and with five half-pins was fixed on the premaxilla bone. The crane with the ESF on the beak was able to feed smoothly by itself. The ESF was removed 49 days after the first surgery. Beak malocclusion, which was observed in the latter half period of fixing, spontaneously improved within one month after removal of the ESF. This is the first successful case of repair of an upper beak fracture in a Red-crowned crane.  相似文献   

19.
A nine-year-old, spayed female crossbred dog sustained a traumatic skin lesion to the right proximal pelvic limb, extending to the extensor surface of the stifle. Surgical management of the wound included primary closure using a body skin flap fashioned from the right caudolateral abdominal wall. To achieve closure and prevent tension on the wound, the coxofemoral and stifle joints on the affected side needed to be immobilised in flexion. Flexion immobilisation of the stifle was achieved using the anatomical principle of muscle reciprocation. The ipsilateral tarsal joint was immobilised in flexion using a uniplanar-bilateral (type II) transarticular external skeletal fixator and this resulted in the automatic flexion of the stifle. The fixator was removed six weeks postoperatively when the wound had healed. There were no apparent complications associated with the fixator either during its use or in the longer term following its removal.  相似文献   

20.
An aiming device was used to guide insertion of fixation pins in a type-II (bilateral) external fixator stabilizing an open canine tibial fracture. This device, designed by the Swiss AO group, has multiple applications in orthopedic surgery, because it accurately locates the exit point of a pin or drill hole on the far side of a bone or fractured bone fragment. When used with the type-II external fixator, it greatly facilitates pin placement by ensuring that, as a pin emerges from the bone, it is in line with the second clamp on the opposite connecting bar.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号