首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Objective – To evaluate a method for endoscopically guided nasojejunal tube placement allowing short‐term postduodenal feeding and chyme withdrawal in dogs. Design – Pilot study. Setting – University teaching hospital. Animals – Three healthy Beagle dogs with jejunal nipple valve fistulas. Interventions – After the dogs were anesthetized, an 8 Fr, 250‐cm polyvinyl chloride catheter was advanced through a gastroscope into the jejunum. Correct jejunal placement was established using endoscopic visualization and confirmed by fluoroscopy and radiography. The proximal end of the tube was pulled out through 1 nostril and sutured to the skin of the forehead. Thereafter, jejunal feeding was administered for 4 days. Follow‐up examinations included daily confirmation of the tube's position using radiography, physical examination, and blood analyses. Withdrawal of jejunal chyme was performed after jejunal and oral feeding. Measurements and Main Results – Fluoroscopic examination confirmed that endoscopic visualization alone allowed correct jejunal placement. During a 4‐day postduodenal feeding period, repeated radiographic examination revealed stable positioning of the tubes within the jejunum with minor cranial displacement. The tubes were functional throughout the study without causing identifiable problems. Repeated physical examinations and blood analysis showed no abnormalities. We were able to administer the daily caloric requirements as a liquid diet. Jejunal chyme was successfully withdrawn via the tube. Conclusions – Endoscopically guided nasojejunal tube placement was shown to be a minimally invasive, well‐tolerated method for short‐term jejunal feeding in healthy dogs. This technique is a viable option for dogs requiring jejunal feeding but not laparotomy. The feasibility of chyme sampling is another unique application of the procedure.  相似文献   

2.
In veterinary patients, postgastric feeding is indicated for uncontrollable gastric vomiting, gastroparesis, biliary tract disease, pancreatitis, and for patients at increased risk for aspirating secondary to decreased mentation, prolonged recumbency, or an unprotected airway. Postgastric feeding may be implemented via the placement of a jejunal feeding tube. These tubes can be placed surgically (jejunostomy tubes) or with fluoroscopic or endoscopic guidance. This article will focus on methods of jejunal feeding-tube placement, advantages and disadvantages of the methods described, and complications associated with jejunal feeding.  相似文献   

3.
Objective— To report the technique, complications, and effectiveness of thoracoscopic subphrenic pericardectomy (SPP) using double‐lumen endobronchial intubation for alternating 1‐lung (OLV) in healthy dogs. Study Design— Prospective cohort study. Animals— Mature purpose‐bred dogs (n=7). Methods— Bronchoscope‐assisted placement of a left‐sided double‐lumen endobronchial tube, immediately before surgery, allowed intraoperative alternation of ventilation between lung fields. A camera portal was established in a subxyphoid location. Two instrument portals were established at the 4th–6th intercostal spaces on the right and left sides. A vessel‐sealing device was used to create the subphrenic pericardectomy. After termination of the procedure, dogs were humanely euthanatized under anesthesia and necropsy performed. In each dog, the extent of pericardectomy and any complications were evaluated. Results— Technical difficulties with tube placement occurred in 4 dogs, but alternating OLV was achieved in all dogs and SPP completed successfully. Median surgical time was 87.5 minutes (range, 80–105 minutes). At necropsy, 0.5–2 cm of pericardial tissue remained ventral to the intact phrenic nerve in 6 dogs; in 1 dog, the phrenic nerve was transected on the left side only. Conclusions— Thoracoscopic subphrenic pericardectomy is a technically feasible procedure in healthy dogs. Double‐lumen endobronchial intubation allowed alternating OLV without intraoperative bronchoscopically guided tube manipulation in all but 1 dog. Clinical Relevance— Thoracoscopic subphrenic pericardectomy could potentially be used for management of conditions where relief of pericardial constriction or access to intrapericardial structures is desired.  相似文献   

4.
OBJECTIVE: To develop laparoscopic-assisted techniques for enterostomy feeding tube placement and full-thickness biopsy of the jejunum in dogs. ANIMALS: 15 healthy dogs. PROCEDURE Dogs were anesthetized, and positive pressure ventilation was provided. A trocar cannula for the laparoscope was inserted on the ventral midline caudal to the umbilicus. For enterostomy tube placement, a second trocar cannula was placed lateral to the right rectus abdominis muscle, and a Babcock forceps was used to grasp the duodenum and elevate it to the incision made for the cannula. The duodenum was sutured to the abdominal wall, and a feeding tube was inserted. For jejunal biopsy, a third trocar cannula was placed lateral to the left rectus abdominis muscle. A portion of jejunum was elevated to the incision for the second or third cannula, and a full-thickness biopsy specimen was obtained. A second specimen was obtained from another portion of jejunum, and retention sutures for the 2 biopsy sites were tied so that serosal surfaces of the biopsy sites were apposed to each other. Dogs were euthanatized 30 days after surgery. RESULTS: The enterostomy tube was properly positioned and functional in all 8 dogs that underwent laparoscopic-assisted enterostomy tube placement, and sufficient samples for histologic examination were obtained from all 7 dogs that underwent laparoscopic-assisted jejunal biopsy. None of the dogs had any identifiable problems after surgery. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that in dogs, laparoscopic-assisted procedures for enterostomy tube placement and jejunal biopsy are an acceptable alternative to procedures performed during a laparotomy.  相似文献   

5.
Objective To compare the success rates of central venous catheter placement (CVCP) in dogs using electrocardiograph (ECG)‐guided and external landmark (‘blind’) techniques. To report success rates determined retrospectively of CVCPs in dogs using external landmarks at a tertiary referral institution. Study design Prospective blinded comparison of techniques. Retrospective analysis of case records. Animals Adult Beagles weighing 11.9 ± 2.6 kg were used in the experimental group (n = 38). Various breeds of dogs were in the retrospective clinical group (n = 33). Methods Laboratory dogs were anesthetized and CVCPs were placed using a modified Seldinger technique. Catheter tip position was first based on external landmarks and then the catheter was repositioned using an ECG‐guided placement. The ECG‐guided technique used the V‐lead with the positive electrode attached to the guide wire. Catheter placement was determined by moving the catheter cephalad and caudad to the point of maximum p‐wave amplitude and then withdrawing the catheter 1–2 cm from this point. Catheter position with each technique was determined using a lateral thoracic radiograph. Retrospective data were collected from the medical records of dogs that had CVCPs using anatomical landmarks and corresponding thoracic radiographs. Results The number of successful CVCP attempts was the same for both prospective groups (21/38). There was no statistically significant difference in success between the ECG‐guided technique and the blind technique. From the retrospective investigation 10/33 of the cases that fit the criteria had correct CVCPs. Conclusions and clinical relevance The odds of correctly placing a central venous catheter by ECG‐guidance were the same as the external landmark technique. The ECG‐guided technique may be useful in situations where external landmarks are not readily available.  相似文献   

6.
Four dogs were diagnosed with nasopharyngeal stenosis using e ndoscopy and magnetic resonance imaging. Treatment using balloon‐expandable metallic stent, placed under fluoroscopic and endoscopic guidance, resulted in immediate resolution of clinical signs. All dogs were clinically normal 40 to 62 months following stent placement.  相似文献   

7.
Objective— To evaluate outcome by radiographic assessment after closed reduction and percutaneous screw fixation in lag fashion of sacroiliac fracture‐luxations in dogs. Study Design— Retrospective study. Animals— Dogs (n=24) with sacroiliac fracture‐luxations. Methods— Medical records (1999–2006) and radiographs of 24 dogs (29 fracture‐luxations) that had stabilization of sacroiliac fracture‐luxation by fluoroscopic‐guided closed reduction and percutaneous screw fixation in lag fashion were reviewed. Signalment, body weight, number, and location of all concurrent injuries and implants used for repair were recorded. Radiographs were used to evaluate the accuracy of screw placement in the sacral body, screw depth/sacral width ratio, reduction of the sacroiliac joint, pelvic canal diameter, and hemipelvic canal width. Radiographic re‐examination (range, 4 to >8 weeks postoperatively) was available for evaluation. Results— Mean screw depth/sacral width ratio on immediate postoperative and re‐examination radiographs was 64% and 61%, respectively. Mean percentage reduction of the sacroiliac joint on immediate postoperative and re‐examination radiographs were 91% and 87%, respectively. Pelvic canal diameter ratio demonstrated successful restoration of the pelvic canal. Hemipelvic canal width ratio documented successful closed reduction repair independent of concurrent pelvic injuries. Conclusion— Successful repair of sacroiliac fracture‐luxations, determined by radiographic assessment, can be achieved by fluoroscopic‐guided closed reduction and percutaneous screw fixation in lag fashion. Clinical Relevance— Fluoroscopic‐guided closed reduction and percutaneous screw fixation in lag fashion of sacroiliac fracture‐luxations is a minimally invasive technique that restores and maintains pelvic canal dimensions and should be considered as an alternative to open reduction or nonsurgical management of sacroiliac fracture‐luxations.  相似文献   

8.
OBJECTIVE: To evaluate feasibility of performing laparoscopic-assisted placement of a jejunostomy feeding tube (J-tube) and compare complications associated with placement, short-term feedings, and medium-term healing with surgically placed tubes in dogs. DESIGN: Prospective study. ANIMALS: 15 healthy mixed-breed dogs. PROCEDURES: Dogs were randomly allocated to undergo open surgical or laparoscopic-assisted J-tube placement. Required nutrients were administered by a combination of enteric and oral feeding while monitoring for complications. Radiographic contrast studies documented tube direction and location, altered motility, or evidence of stricture. RESULTS: Jejunostomy tubes were successfully placed in the correct location and direction in all dogs. In the laparoscopic group, the ileum was initially selected in 2 dogs, 2 dogs developed moderate hemorrhage at a portal site, and 2 J-tubes kinked during placement but were successfully readjusted postoperatively. All dogs tolerated postoperative feedings. All dogs developed minor ostomy site inflammation, and 1 dog developed bile-induced dermatitis at the ostomy site. Despite mild, transient neutrophilia, no significant difference was noted in WBC counts between groups. No dog had altered gastric motility or evidence of stricture, although the jejunopexy site remained identifiable in several dogs at 30 days. CONCLUSIONS AND CLINICAL RELEVANCE: Requirements for successful J-tube placement were met by use of a laparoscopic-assisted technique, and postoperative complications were mild and comparable to those seen with surgical placement. Laparoscopic-assisted J-tube placement compares favorably to surgical placement in healthy dogs and should be considered as an option for dogs requiring enterostomy feeding but not requiring a celiotomy for other reasons.  相似文献   

9.
Interest in noninvasive feeding tube placement in companion animals led to the adaption of a human technique utilizing endoscopy to place nasojejunal feeding tubes. Data from medical records in which nasojejunal feeding tubes were attempted were reviewed. Feeding tubes were attempted and successfully placed in five dogs within a median of 35 min. Feeding tubes remained in place for approximately 7 days. Complications included facial irritation (5/5), sneezing (5/5), fractured facial sutures (4/5), vomiting (3/5), diarrhea (3/5), crimping of feeding tube (3/5), regurgitation (1/5), epistaxis (1/5), clogging of the feeding tube (2/5), and oral migration with premature removal of the feeding tube (1/5). The deployment technique used in this study was found to be cumbersome. Despite minor complications, endoscopy can be used to rapidly and accurately place nasoenteric feeding devices.  相似文献   

10.
Objective: To evaluate the ability of capnography to document proper placement of nasoesophageal (NE) and nasogastric (NG) feeding tubes. This study was conducted in 3 phases. Phase I of this study was designed in order to test the efficacy of capnography to distinguish placement of a feeding tube in the alimentary tract versus the respiratory tract. Phase II was designed in order to document that carbon dioxide (CO2) could be measured through a polyvinyl chloride (PVC) feeding tube. Phase III was performed in order to evaluate the technique of continuous monitoring during insertion of the feeding tube into the esophagus and stomach as would be performed during a clinical‐tube placement. Design: Prospective study. Setting: Research laboratory. Animals: 24 adult dogs. Interventions: In Phase I, sedated dogs were instrumented with an intratracheal catheter and an 8 French feeding tube placed nasally into the distal esophagus and later advanced into the stomach. In Phase II, dogs were anesthetized and an 8 French feeding tube was placed down the endotracheal tube, then into the esophagus and later advanced into the stomach. In Phase III, sedated dogs were instrumented with an 8 French feeding tube inserted intranasally and then advanced to the level of the nasopharynx, distal esophagus and, lastly, the stomach. Fluoroscopy was used in order to determine location of the feeding tube. Measurements and main results: Phase I measurements included respiratory rate and CO2 from the trachea, esophagus, and stomach and pH of gastric fluid sample. Phase II measurements included respiratory rate and CO2 from the endotracheal tube, feeding tube in the endotracheal tube, feeding tube in the distal esophagus, and feeding tube in the stomach. Phase III data collection included respiratory rate and CO2 as the tube was passed through the nasal cavity, nasopharynx, esophagus and stomach. Phase I fluid samples were collected from 5 of the 9 dogs and had pH values from 1.68 to 4.20. In both phases, values for the respiratory rate and CO2 from the esophagus and stomach were 0 ± 0, significantly lower (P < 0.001) than the values from the trachea. In Phase II, there was no significant difference between the respiratory rates (P = 0.886) and CO2 (P = 0.705) readings obtained from the endotracheal tube compared to readings from the feeding tube in the endotracheal tube. In Phase III, there was a significant difference (P < 0.001) between the respiratory rates and CO2 readings obtained from the nasal cavity and the nasopharynx when compared to those readings obtained from the esophagus and stomach. Measurement of CO2 and respiratory rate resulted in a reading of 0 every time the feeding tube was in the esophagus or stomach. Conclusions: Capnography may be used in order to detect airway placement of NE and NG tubes.  相似文献   

11.
Objective – To determine whether older dogs will have a more pronounced pro‐inflammatory response and blunted anti‐inflammatory response to pathogen‐associated molecular patterns (PAMPs) compared with younger dogs. Design – Prospective. Setting – University teaching hospital. Animals – Thirty‐eight privately owned sexually altered dogs of various ages. Interventions – Blood was collected for HCT, WBC count, plasma biochemical analysis, and whole blood culture. Whole blood was stimulated with lipopolysaccharide (LPS) or, lipoteichoic acid or, peptidoglycan or, addition of phosphate‐buffered saline. Tumor necrosis factor (TNF), interleukin (IL)‐6, and IL‐10 production from whole blood were compared among young, middle aged, and geriatric dogs. Measurements and Main Results – LPS, lipoteichoic acid, and peptidoglycan stimulated significant TNF, IL‐6, and IL‐10 production from canine whole blood compared with phosphate‐buffered saline. Whole blood from geriatric dogs had a blunted IL‐10 response to LPS stimulation and middle‐aged dogs had increased LPS‐induced TNF production compared with the other groups. Conclusion – PAMPs from gram‐positive and gram‐negative bacteria stimulate TNF, IL‐6, and IL‐10 production from canine whole blood. The inflammatory mediator response to PAMPs from gram‐negative bacteria alters with age and may be one factor contributing to mortality in geriatric dogs with sepsis.  相似文献   

12.
Objective – To test whether an initial plasma lactate≥6.0 mmol/L is associated with the presence of macroscopic gastric wall necrosis and overall survival in dogs presenting with gastric dilatation‐volvulus (GDV). Additionally, if no association was identified we sought to identify a different predictive initial plasma lactate concentration and to examine whether serial plasma lactate concentrations provide better prediction of survival. Design – Retrospective study over a 5‐year period (2003–2007). Setting – Urban private referral small animal teaching hospital. Animals – Eighty‐four client‐owned dogs with a diagnosis of GDV and plasma lactate measurements. Interventions – None. Measurements and Main Results – There was no statistically significant relationship found between survival and the presence of macroscopic gastric wall necrosis with the initial plasma lactate≥6 mmol/L. There was a significant relationship between the initial plasma lactate >2.9 mmol/L for predicting necrosis and <4.1 mmol/L for predicting survival to discharge. Forty dogs that had an increased initial plasma lactate (>2.5 mmol/L) also had a subsequent plasma lactate measured within 12 hours of presentation, with 37/40 dogs surviving and 70% of these surviving dogs having the subsequent lactate decrease by≥50% within 12 hours. The 3/40 that died failed to decrease their plasma lactate by≥50% from the initial blood lactate. Conclusion – The results of this study indicate that an initial presenting plasma lactate concentration≥6.0 mmol/L is not predictive of macroscopic gastric wall necrosis or survival in dogs presenting with GDV. A decrease in plasma lactate concentrations≥50% within 12 hours may be a good indicator for survival. Limitations to the study include its retrospective nature, the small number of patients, and the number of dogs that were euthanized rather than allowed to progress to a natural outcome.  相似文献   

13.
The standard technique for placing a needle into the canine lumbar subarachnoid space is primarily based on palpation of anatomic landmarks and use of probing movements of the needle, however, this technique can be challenging for novice operators. The aim of the current observational, prospective, ex vivo, feasibility study was to compare ultrasound‐guided vs. standard anatomic landmark approaches for novices performing needle placement into the lumbar subarachnoid space using dog cadavers. Eight experienced operators validated the canine cadaver model as usable for training landmark and ultrasound‐guided needle placement into the lumbar subarachnoid space based on realistic anatomy and tissue consistency. With informed consent, 67 final year veterinary students were prospectively enrolled in the study. Students had no prior experience in needle placement into the lumbar subarachnoid space or use of ultrasound. Each student received a short theoretical training about each technique before the trial and then attempted blind landmark‐guided and ultrasound‐guided techniques on randomized canine cadavers. After having performed both procedures, the operators completed a self‐evaluation questionnaire about their performance and self‐confidence. Total success rates for students were 48% and 77% for the landmark‐ and ultrasound‐guided techniques, respectively. Ultrasound guidance significantly increased total success rate when compared to the landmark‐guided technique and significantly reduced the number of attempts. With ultrasound guidance self‐confidence was improved, without bringing any significant change in duration of the needle placement procedure. Findings indicated that use of ultrasound guidance and cadavers are feasible methods for training novice operators in needle placement into the canine lumbar subarachnoid space.  相似文献   

14.
Gastric myoelectric activity was measured in 10 dogs with spontaneous gastric dilatation-volvulus (GDV). Myoelectric activity was recorded with temporary, retrievable wire electrodes placed on the serosal surface of the stomach after derotation and tube gastrostomy. Gastric myoelectric activity was recorded for 1 hour daily, beginning with the day of surgery (less than 24 hours), 24, 48, 72, 96, 120, 144, and 168 hours after surgery. Recordings were also obtained for 1 hour daily after feeding, beginning 24 hours after surgery. Bradygastria was the predominate dysrhythmia immediately after surgery and at hour 24. The mean slow wave frequency was more than normal at hours 48 to 168 due to an increase in tachygastria and arrhythmias. The slow wave frequency significantly decreased after feeding at hours 120 and 144. The overall mean percentage of dysrhythmias was significantly decreased after feeding at hour 72 only. The mean percentage of spike activity ranged from 37.7 +/- 12.5 to 75.7 +/- 6.2 throughout the 8-day study period. Thus, gastric myoelectric activity was disrupted in these dogs with spontaneous GDV and subsequent tube gastrostomy. Feeding did not greatly diminish these dysrhythmias.  相似文献   

15.
Differentiating hepatocellular disease versus biliary obstruction can be challenging in dogs presented for icterus. The purpose of this prospective study was to determine the feasibility of percutaneous contrast ultrasound‐guided cholecystography in dogs. Ten normal dogs weighing 7.6–13.0 kg (median 9.8 kg) were recruited. All dogs were considered normal based on complete blood count, serum chemistry profile, ultrasound examination, and percutaneous radiographic cholecystography. Percutaneous contrast ultrasound‐guided cholecystography was performed using 0.5 ml of commercially available contrast agent and two conventional ultrasound machines for simultaneous scanning at two different locations. Two observers independently evaluated the time to initial detection of contrast in the proximal duodenum and duration of contrast enhancement via visual monitoring. Dynamic contrast enhancement was calculated using time‐intensity curves. Mean (±SD) and median (range) of time to initial detection were 8.60 s (± 3.35) and 8.0 s (2.0–11.0), respectively, and mean and median duration were 50.45 s (±23.24) and 53.0 s (20.0 – 70.0), respectively. Mean, median, and range of peak intensity were 114.1 mean pixel value (MPV) (SD ± 30.7), 109.2 MPV, and 79.7–166.7, respectively, and mean, median, and range of time to peak intensity were 26.1 s (SD ± 7.1 s), 24.0 s, and 19.0–41.0 s, respectively. Findings indicated that percutaneous contrast ultrasound‐guided cholecystography is a feasible technique for detecting and quantifying patency of the bile duct in normal dogs. Future studies are needed to assess the diagnostic utility of this technique for dogs with biliary obstruction.  相似文献   

16.
Nonendoscopic tube gastrostomy was performed on 41 anesthetized dogs using the technique of Fulton and Dennis with or without gastric insufflation prior to tube placement. Immediately after tube placement, dogs were euthanized and postmortem examinations performed. When gastric insufflation was not performed (group I), gastrostomy tubes penetrated the visceral surface of the stomach in 25% of dogs. The deep leaf of the omentum was interposed between stomach and body wall in the majority of these dogs, exposing other intra-abdominal organs to potential injury. Additionally, displacement and tethering of the spleen cranial to the gastrostomy site were observed in 33% of dogs in group I. Similar results were obtained when preplacement gastric insufflation was performed after the orogastric tube was inserted sufficiently far to displace the stomach laterally against the body wall (group II). In contrast, consistent positioning of gastrostomy tubes through the parietal surface of the stomach was achieved when the stomach was insufflated prior to lateralizing the left abdominal wall with the gastric end of the orogastric tube (group III). It was concluded that the blind percutaneous gastrostomy technique is made safer by insufflating the stomach immediately prior to pushing the gastric wall laterally into contact with the parietal peritoneum. J Vet Intern Med 1996;10:15–20. Copyright © 1996 by the American College of Veterinary Internal Medicine .  相似文献   

17.
18.
19.
There are few reported estimates of amino acid (AA) kinetics in adult mammals and none exist in adult dogs. The study objectives were to evaluate the use of oral isotope delivery in contrast to the more commonly used intravenous (IV) delivery to estimate AA kinetics in adult dogs and to estimate splanchnic extraction and gastric emptying using a commonly accepted mathematical model. Dogs received 25 × 1/2‐hourly meals (13 g/kg BW/day) and either an oral or IV bolus of l‐ [1‐13C]Phe (12 mg/kg BW). Blood samples were taken immediately before each feeding. Concentrations of plasma Phe were measured using liquid chromatography‐tandem mass spectrometry. There were no differences in baseline plasma Phe concentrations (34 μm ± 0.61), Phe distribution volume, Phe pool size and rate constants between dogs when the tracer was administered IV or orally (p > 0.25). Decay curve for plasma l ‐[1‐13C]Phe differed between IV and oral dosing protocols with IV dosing fit best using a two‐compartment model. Phe disappeared from plasma at a mean rate of 2.8%/min. Estimates of gastric emptying and splanchnic extraction did not differ based on oral or IV tracer dosing when the decay curves were fit with the two‐compartment model (p > 0.40). The half‐life for gastric emptying was 18 min, and first‐pass Phe extraction by the splanchnic bed was 24% of the dietary Phe. These results suggest that oral isotope dosing can be used as an alternative to IV isotope dosing in studies that utilize a primed, constant dosing approach to measure protein and amino acid kinetics.  相似文献   

20.
A new enterostomy tube placement technique is described for provision of nutrients into the duodenum. Placement of the duodenostomy tube (d-tube) is performed through a limited right flank approach under sedation and local anesthesia. Seven client-owned animals (three dogs and four cats) requiring enteral nutritional support were selected for d-tube placement. Patients were fed via the d-tube for two to 28 days. Complications included discomfort when manipulating and exteriorizing the duodenum, discomfort with bolus feedings, local cellulitis, and tube site infection. All complications resolved without further incident. This technique should be considered in patients that are not good candidates for prolonged general anesthesia or esophageal or gastric feeding, or patients being mechanically ventilated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号