首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Modifications of a Type 1a external skeletal fixator (ESF) frame were evaluated by alternately placing transfixation pins on opposite sides of the connecting rod (Type 1a-MOD) or by placing additional connecting rods on either of the two inside (Type 1a-INSIDE) or two outside (Type 1a-OUTSIDE) transfixation pins. The objective of this study was to evaluate the stiffness of these modifications in terms of axial compression (AC), cranial-caudal bending (CCB), and medial-lateral bending (MLB). We hypothesized that these designs would allow significant increase in unilateral frame stiffness, over Type 1a, without proportional increase in frame complexity or technical difficulty of application. All of the ESF frames were constructed using large IMEX SKtrade mark clamps, 3.2 mm threaded fixation pins, 9.5 mm carbon fibre connecting rods and Delrin rods as bone models. Nine, eight pin frames of each design were constructed, and subjected to repetitive non-destructive loading forces (AC, CCB, MLB) using a materials testing machine. Frame construct stiffness for each force (AC, CCB, MLB) was derived from load-deformation curve analysis and displayed in N/mm. Data revealed the 1a-MOD and 1a-OUTSIDE constructs had significantly increased stiffness in CCB and AC as compared to the Type 1a constructs while all of the modified constructs were significantly stiffer in MLB than the Type 1a constructs.  相似文献   

2.
OBJECTIVE: To determine relative effects of ring diameter and wire tension on axial biomechanical properties of 4-ring circular external skeletal fixator constructs. SAMPLE POPULATION: 4-ring circular external skeletal fixator constructs and artificial bone models. PROCEDURE: 4-ring constructs were assembled, using 50-, 66-, 84-, or 118-mm-diameter rings. Two 1.6-mm-diameter fixation wires were attached to opposing surfaces of each ring at intersection angles of 90 degrees and placed through a gap-fracture bone model. Three examples of each construct were loaded in axial compression at 7 N/s to a maximum load of 400 N at each of 4 wire tensions (0, 30, 60, and 90 kg). Response variables were determined from resulting load-displacement curves (construct stiffness, load at 1 mm of displacement, displacement at 400 N). RESULTS: Ring diameter and wire tension had a significant effect on all response variables and had a significant interaction for construct stiffness and displacement at 400 N. Significant differences within all response variables were seen among all 4 ring diameters and all 4 wire tensions. As ring diameter increased, effect of increasing wire tension on gap stiffness and gap displacement at 400 N decreased. Ring diameter had a greater effect than wire tension on all response variables. CONCLUSIONS AND CLINICAL RELEVANCE: Although effects of wire tension decrease as ring diameter increases, placing tension on wires in larger ring constructs is important because these constructs are inherently less stiff. The differential contribution of ring diameter, wire tension, and their interactions must be considered when using circular external skeletal fixators.  相似文献   

3.
The biomechanical characteristics of 1.2 mm diameter allogeneic cortical bone pins harvested from the canine tibia were evaluated and compared to 1.1 mm diameter stainless steel pins and 1.3 mm diameter polydioxanone (PDS) pins using impact testing and four-point bending. The biomechanical performance of allogeneic cortical bone pins using impact testing was uniform with no significant differences between sites, side, and gender. In four-point bending, cortical bone pins harvested from the left tibia (204.8 +/- 77.4 N/mm) were significantly stiffer than the right tibia (123.7 +/- 54.4 N/mm, P = 0.0001). The site of bone pin harvest also had a significant effect on stiffness, but this was dependent on interactions with gender and side. Site C in male dogs had the highest mean stiffness in the left tibia (224.4 +/- 40.4 N/mm), but lowest stiffness in the right tibia (84.9 +/- 24.2 N/mm). Site A in female dogs had the highest mean stiffness in the left tibia (344.9 +/- 117.4 N/mm), but lowest stiffness in the right tibia (60.8 +/- 3.7 N/mm). The raw and adjusted bending properties of 1.2 mm cortical bone pins were significantly better than 1.3 mm PDS pins, but significantly worse than 1.1 mm stainless steel pins (P < 0.0001). In conclusion, cortical bone pins may be suitable as an implant for fracture fixation based on initial biomechanical comparison to stainless steel and PDS pins used in clinical practice.  相似文献   

4.
OBJECTIVE: To evaluate stiffness and bone-pin interface stress for a transcortical tapered-sleeve pin (TSP) that incorporates bilateral tapered sleeves over a transcortical pin. SAMPLE POPULATION: 14 third metacarpal bones (MCIII) collected from adult horses of various breeds. PROCEDURE: Each MCIII was cut in half to provide 2 test specimens. Pins (conventional and TSP) of 3 diameters (6.35, 7.94, and 9.50 mm) were inserted in specimens (3 specimens for each diameter and each type of pin). The test fixture simulated a typical sidebar-span skeletal fixation device for horses. Single cycle load-deflection tests were performed. Cyclic fatigue tests of TSP were performed to evaluate fatigue characteristics and stress conditions at the bone-pin interface. Maximum stress and strain were calculated, and results were compared with existing data on fatigue characteristics of bone. RESULTS: Significant increases in stiffness (load-deflection) and higher loads at yield point were detected for the TSP (stiffness for conventional 9.50mm pins, 4,500 N/mm; stiffness for TSP, 19,988 N/mm). Results of cyclic tests revealed a close correlation with existing data on fatigue characteristics. CONCLUSIONS AND CLINICAL RELEVANCE: The TSP described here is stiffer than conventional transcortical pins, and stress across the bone-pin interface is more evenly distributed. Use of this TSP should minimize major problems encountered during external fixation associated with the transcortical pin and bone-pin interface (ie, bone necrosis, infection of the pin track, pin loosening, and bone failure).  相似文献   

5.
The purpose of this study was to determine the respective contribution of each of the following parameters to the compressive, bending, and torsional rigidity of the Kirschner-Ehmer (KE) external fixation splint as applied to canine tibiae with an osteotomy gap: bilateral versus unilateral splints; increasing the number of fixation pins; altering the diameter of fixation pins and side bars; decreasing side bar distances from the bone; increasing pin separation distances in each pin group; decreasing distances between pin groups; altering pin clamp orientation; and altering side bar conformation. Bilateral splints were 100% (mean) stiffer than unilateral splints, with stiffness enhanced to the greatest extent in mediolateral bending and torsion. Increasing pin numbers stiffened both bilateral (mean, 41%; 8 versus 4) and unilateral splints (mean, 14%; 8 versus 4). Medium KE splints were 85% (mean) stiffer than small KE splints. Decreasing side bar distances to the bone from 1.5 cm to 1.0 cm to 0.5 cm increased stiffness of both bilateral and unilateral splints by a mean of 13% to 35%. Widening pin spacing from 1.67 cm to 2.5 cm increased stiffness in craniocaudal bending only (56% increase, bilateral splints; 73% increase, unilateral splints). Decreasing the distance between pin groups from 5.84 cm to 2.5 cm increased stiffness in torsion between 23% (unilateral splints) and 45% (bilateral splints) and decreased stiffness of unilateral splints by 29% in craniocaudal bending. Altering pin clamp configuration so that the bolts of the clamp were inside the side bar rather than outside the side bar increased stiffness in axial compression only (73% increase, bilateral splints; 54% increase, unilateral splints). Conforming the lateral side bar to the tibiae increased only axial compressive stiffness by 77% but was no different than placing the clamps inside the side bars of an unconformed bilateral splint. These results quantify the relative importance of specific parameters affecting KE splint rigidity as applied to unstable fractures in the dog.  相似文献   

6.
OBJECTIVE: To evaluate in vitro holding power and associated microstructural and thermal damage from placement of positive-profile transfixation pins in the diaphysis and metaphysis of the equine third metacarpal bone. SAMPLE POPULATION: Third metacarpal bones from 30 pairs of adult equine cadavers. PROCEDURE: Centrally threaded positive-profile transfixation pins were placed in the diaphysis of 1 metacarpal bone and the metaphysis of the opposite metacarpal bone of 15 pairs of bones. Tensile force at failure for axial extraction was measured with a materials testing system. An additional 15 pairs of metacarpal bones were tested similarly following cyclic loading. Microstructural damage was evaluated via scanning electron microscopy in another 6 pairs of metacarpal bones, 2 pairs in each of the following 3 groups: metacarpal bones with tapped holes and without transfixation pin placement, metacarpal bones following transfixation pin placement, and metacarpal bones following transfixation pin placement and cyclic loading. Temperature of the hardware was measured with a surface thermocouple in 12 additional metacarpal bones warmed to 38 C. RESULTS: The diaphysis provided significantly greater resistance to axial extraction than the metaphysis. There were no significant temperature differences between diaphyseal and metaphyseal placement. Microstructural damage was limited to occasional microfractures seen only in cortical bone of diaphyseal and metaphyseal locations. Microfractures originated during drilling and tapping but did not worsen following transfixation pin placement or cyclic loading. CONCLUSIONS AND CLINICAL RELEVANCE: Centrally threaded, positive-profile transfixation pins have greater resistance to axial extraction in the diaphysis than in the metaphysis of equine third metacarpal bone in vitro. This information may be used to create more stable external skeletal fixation in horses with fractures.  相似文献   

7.
OBJECTIVE: To compare the stiffness and pin stresses of three sizes of external fixator systems with stainless-steel and acrylic connecting bars. STUDY DESIGN: Finite element analysis. METHODS: Small, medium, and large external fixator systems of type I and type II configurations were modeled for finite element analysis. Each model was evaluated with a standard stainless-steel and three different diameters of acrylic connecting bar. Displacements and stresses were calculated for the loading modes of axial compression, medio-lateral bending, cranio-caudal bending, and torsion. The location of the pin experiencing maximum stress was determined for all configurations and loading modes. RESULTS: Acrylic column diameters of 9.53 mm for the small external fixator system and 15.9 mm for the medium external fixator system provide equivalent stiffness and maximum pin stresses to those provided by the standard stainless-steel connecting bars (3.2- and 4.8-mm diameter, respectively). The largest diameter acrylic column tested (31.75-mm) produced lower stiffness and higher maximum pin stresses than the standard stainless-steel connecting bar (11.1-mm diameter). CONCLUSIONS: When applying a small or medium external fixator, an acrylic column of 9.53-mm or 15.9-mm diameter, respectively, can be used. For a large external fixator system, an acrylic column of diameter >31.75 mm is required. CLINICAL RELEVANCE: The sizes of acrylic connecting bars for use in small and medium external fixator systems have been determined. Large systems should incorporate the standard stainless-steel connecting bar.  相似文献   

8.
OBJECTIVE: To determine total stiffness and gap stiffness of an external fixation system in a canine mandibular fracture gap model incorporating a full interdental pin as the only point of rostral fixation in a bilateral type-I external fixator. SAMPLE POPULATION: 10 canine mandibles. PROCEDURE: Bilateral mandibular ostectomies were performed between premolars 3 and 4. A type-I external fixator incorporating a full interdental pin was placed to stabilize a 0.5-cm fracture gap. Four pin configurations (intact mandibular bodies with fixator; ostectomized mandibular bodies and complete fixator; ostectomized mandibular bodies with caudal pins of rostral fragment cut; ostectomized mandibular bodies with all pins of rostral fragment cut) were tested in dorsoventral bending 5 times on each mandible. The full interdental pin remained intact in all configurations. Total stiffness and gap stiffness were determined for each configuration on a materials testing machine. RESULTS: Total stiffness of intact mandibles was significantly greater than that of ostectomized mandibles, regardless of external fixator configuration. However, total stiffness and gap stiffness were not significantly different among different external fixator configurations applied to ostectomized mandibles. CONCLUSION AND CLINICAL RELEVANCE: External fixator configurations with only the full interdental pin engaging the rostral fragment were as stiff as configurations that had 2 or 4 additional pins in the rostral fragment for the applied loads. External fixators for rostral mandibular fractures may be rigidly secured with rostral fragment implants applied extracortically, avoiding iatrogenic trauma to teeth and tooth roots.  相似文献   

9.
OBJECTIVE: To compare the in vitro holding power and associated microstructural damage of 2 large-animal centrally threaded positive-profile transfixation pins in the diaphysis of the equine third metacarpal bone. SAMPLE POPULATION: 25 pairs of adult equine cadaver metacarpal bones. PROCEDURE: Centrally threaded positive-profile transfixation pins of 2 different designs (ie, self-drilling, self-tapping [SDST] vs nonself-drilling, nonself-tapping [NDNT] transfixation pins) were inserted into the middiaphysis of adult equine metacarpal bones. Temperature of the hardware was measured during each step of insertion with a surface thermocouple. Bone and cortical width, transfixation pin placement, and cortical damage were assessed radiographically. Resistance to axial extraction before and after cyclic loading was measured using a material testing system. Microstructural damage caused by transfixation pin insertion was evaluated by scanning electron microscopy. RESULTS: The temperature following pin insertion was significantly higher for SDST transfixation pins. Periosteal surface cortical fractures were found in 50% of the bones with SDST transfixation pins and in none with NDNT transfixation pins. The NDNT transfixation pins were significantly more resistant to axial extraction than SDST transfixation pins. Grossly and microscopically, NDNT transfixation pins created less damage to the bone and a more consistent thread pattern. CONCLUSIONS AND CLINICAL RELEVANCE: In vitro analysis revealed that insertion of NDNT transfixation pins cause less macroscopic and microscopic damage to the bone than SDST transfixation pins. The NDNT transfixation pins have a greater pull out strength, reflecting better initial bone transfixation pin stability.  相似文献   

10.
OBJECTIVE: To compare the biomechanical effects of multistage versus one-stage destabilization of a type II external skeletal fixator (ESF) used to stabilize an oblique unstable tibial osteotomy in dogs. STUDY DESIGN: In vitro, in vivo, and ex vivo experimental study. ANIMAL POPULATION: Twelve healthy adult dogs. METHODS: The biomechanical characteristics of the type II ESF used in this study were determined. This fixator was applied to both tibiae of two groups of 6 dogs to stabilize a 2-mm-wide oblique osteotomy. One fixator on each dog remained unchanged throughout the 11-week study (control group). The fixator on the opposite limb was destabilized late and acutely in one group of dogs (single-stage) and early and progressively in the other (multistage). Clinical examination, radiographic examination, and force-plate analysis were used to evaluate the results. All dogs were euthanatized at 11 weeks. All tibiae were scanned to determine the cross-sectional area of the callus in the center of the osteotomy and subjected to biomechanical tests to determine mean pull-out strength of pins and callus strength and stiffness. RESULTS: Stiffness of the type II ESF used in this study was 578 N/mm in axial compression, 0.767 Nm/deg in torsion, 261 N/mm in medio-lateral bending, and 25 N/mm in cranio-caudal bending. Peak vertical forces of the hindlimbs were significantly lower at 2.5 and 5 weeks than before surgery. Peak vertical forces of the hindlimbs did not change before and after destabilization. No significant differences could be detected between the two destabilization sequences or between all control tibiae and pooled destabilized tibiae with regards to radiographic evaluation of the healing osteotomy, cross-sectional periosteal callus area, mean pull-out strength of transfixation pins, callus strength, and callus stiffness. CONCLUSIONS AND CLINICAL RELEVANCE: Bone healing of unstable osteotomies stabilized with a type II ESF is not significantly enhanced by staged destabilization of the fixation as performed in this study.  相似文献   

11.
Fourteen interfragmentary orthopedic wire configurations were tested in torsion using a transverse fracture polyvinylchloride pipe model. These models included single and double Kirschner pins with and without orthopedic wire added to the configuration. The orthopedic wire was applied in either an encircling, figure-of-eight (skewer pin), or cruciate pattern. Double Kirschner pins were applied in a mono- or biplanar fashion. An external fixator model was also tested. Stiffness, yield load, safe load, and energy of absorption were measured and calculated for each model. Orthopedic wire added to any configuration increased stiffness. All single pin configurations with orthopedic wire and the external fixator had the highest stiffness. Two Kirschner pins had a higher torsional yield load and safe load than single pin configurations with or without orthopedic wire. The external fixator model had the highest torsional yield load, safe load and energy of absorption of all configurations tested. However, the external fixator was only significantly different in safe load from the 90° biplanar configurations with wire and the cross pin configuration with encircling wire. The 90° biplanar configurations with wire and the cross pin configuration with encircling wire were equally as effective as the external fixator model in yield load and energy of absorption.  相似文献   

12.
Objective— To compare the axial compression stiffness of osteotomized canine tibiae stabilized with Slocum, Securos, or Synthes plates after a tibial plateau leveling osteotomy (TPLO) procedure. Study Design— In vitro, paired comparison of cadaveric tibial constructs subjected to mechanical testing under an axial load. Sample Population— Canine tibiae (n=16 pairs) from skeletally mature male and female dogs of various breeds (18–55 kg). Methods— Tibial pairs (n=16) were randomly assigned to 1 of 2 study cohorts (n=8 pairs/cohort): cohort 1, tibial osteotomy stabilization with a Slocum or a Securos plate, or cohort 2, tibial osteotomy stabilization with a Slocum or a Synthes plate. One tibia from each pair was stabilized with 1 of each plate design assigned to the cohort after TPLO. A 3.2 mm osteotomy gap was maintained during plate application in all constructs. Load and axial displacement were recorded while constructs were loaded to 2000 N in axial compression. Failure loads were not reported because no distinct yield point or failure point was evident within the load range for many specimens. Failure modes were recorded for each construct, and photographs of typical failures were obtained. Stiffness (N/mm) was calculated from load–displacement curves. Paired comparisons of mean stiffness were performed within study groups using a paired t‐test. Significance was set at P<.05. Results— The mean construct stiffnesses for the Slocum (383±183 N/mm) and Securos (258±64.1 N/mm) constructs were not significantly different (P=.164; power=0.566). The mean construct stiffness for the Synthes constructs (486±91.0 N/mm) was significantly greater than that of the Slocum constructs (400±117 N/mm); P=.0468. Modes of failure for the Slocum (16/16) and Securos (8/8) constructs included plastic deformation of the implant with valgus deformity combined with fibular luxation (2/16 Slocum; 1/8 Securos) or fibular fracture (2/16 Slocum; 4/8 Securos). Most Synthes constructs underwent elastic deformation (7/8). One Synthes construct fractured in the saggital plane through the tibial plateau depression at the point of load application. Conclusions— The Slocum and Securos plate/tibia construct have similar stiffness, whereas the Synthes/tibia constructs are significantly stiffer than the Slocum/tibia constructs. Modes of fixation failure observed in this model were consistent with TPLO fixation failures observed clinically. Clinical relevance— Construct stiffness in axial load varies with implant type. Implants that confer higher stiffness to the construct may result in greater fixation stability in tibial metaphyseal osteotomies.  相似文献   

13.
OBJECTIVE: To determine the validity of finite element analysis (FEA) as a means of examining biomechanical properties of the Kirschner-Ehmer external skeletal fixation system. SAMPLE POPULATION: 10 paired tibiae harvested from skeletally mature dogs weighing between 30 and 38 kg immediately following euthanasia for reasons unrelated to musculoskeletal disease. PROCEDURE: A gap fracture was created in each bone; fragments were stabilized with 3 frame configurations (type I, type II, and type III), using enhanced-profile threaded pins. Each bone-frame construct was tested, using a materials testing machine in 3 modes of testing: axial compression (AC), mediolateral (ML) bending, and craniocaudal (CC) bending, for a total of 9 tests/bone. The elastic limit of the constructs was not exceeded during testing. Mean stiffness values were determined from load-displacement curves. A finite element model of each construct was created, using three-dimensional elastic beam elements, and stiffness values were calculated, using FEA. Correlations between experimental and FEA data then were determined. RESULTS: Significant differences in stiffness were seen among all 3 constructs in CC bending and AC, with stiffness increasing with construct complexity. No significant difference in ML bending stiffness was seen between type-II and type-III constructs; however, both were significantly stiffer than the type-I constructs. The experimental and FEA stiffness data were strongly correlated (AC, r = 0.994; ML bending, r = 0.998; CC bending, r = 0.985). CONCLUSIONS AND CLINICAL RELEVANCE: Strong correlations among experimental and FEA data indicate that FEA is a valid method of comparing stiffness of Kirschner-Ehmer external skeletal fixation constructs.  相似文献   

14.
OBJECTIVE: To determine the effect of 2 hydroxyapatite pin coatings on heat generated at the bone-pin interface and torque required for insertion of transfixation pins into cadaveric equine third metacarpal bone. SAMPLE POPULATION: Third metacarpal bone pairs from 27 cadavers of adult horses. PROCEDURES: Peak temperature of the bone at the cis-cortex and the hardware and pin at the trans-cortex was measured during insertion of a plasma-sprayed hydroxyapatite (PSHA)-coated, biomimetic hydroxyapatite (BMHA)-coated, or uncoated large animal transfixation pin. End-insertional torque was measured for each pin. The bone-pin interface was examined grossly and histologically for damage to the bone and coating. RESULTS: The BMHA-coated transfixation pins had similar insertion characteristics to uncoated pins. The PSHA-coated pins had greater mean peak bone temperature at the cis-cortex and greater peak temperature at the trans-cortex (70.9 +/- 6.4(o)C) than the uncoated pins (38.7 +/- 8.4(o)C). The PSHA-coated pins required more insertional torque (10,380 +/- 5,387.8 Nmm) than the BMHA-coated pins (5,123.3 +/- 2,296.9 Nmm). Four of the PSHA-coated pins became immovable after full insertion, and 1 gross fracture occurred during insertion of this type of pin. CONCLUSIONS AND CLINICAL RELEVANCE: The PSHA coating was not feasible for use without modification of presently available pin hardware. The BMHA-coated pins performed similarly to uncoated pins. Further testing is required in an in vivo model to determine the extent of osteointegration associated with the BMHA-coated pins in equine bone.  相似文献   

15.
OBJECTIVE: To compare the structural properties of interlocking nails (ILNs) locked with bolts (ILNb) to ILN locked with extended bolts connected with a type-IA external skeletal fixator (ILN-ESF) in a fracture gap model. STUDY DESIGN: Experimental study. SAMPLE POPULATION: Synthetic tibial bone substitutes. METHODS: Custom-made synthetic tibial bone substitutes were implanted with standard ILNs locked with either bolts or extended bolts connected to an external skeletal fixation (ESF). Constructs were tested in torsion, bending, and axial compression (n=4/testing mode). Data, consisting of construct compliance and associated deformation, were compared using t-tests. RESULTS: The ILN-ESF construct compliance and deformation were significantly less than those of the ILNb construct in torsion, bending, and compression (P<.001). Slack was present in the ILNb construct under torsion and bending, but not in the ILN-ESF construct, regardless of testing mode. CONCLUSIONS: Substitution of locking bolts with extended bolts connected to an ESF significantly reduced the construct compliance and overall deformation in torsion, bending, and compression. Furthermore, the inherent slack of the ILNb was eliminated by the use of an ESF in torsion and bending. CLINICAL RELEVANCE: The improvement in structural properties of the ILN-ESF constructs could diminish interfragmentary motion at the fracture site and potentially improve bone healing.  相似文献   

16.
OBJECTIVE: To report the biomechanical properties of 3 external skeletal fixation (ESF) devices for use in large ruminants. STUDY DESIGN: In vitro biomechanical testing of ESF constructs. SAMPLE POPULATION: Adult buffalo (weighing, 250-350 kg) tibiae (n=27). METHODS: ESF constructs (bilateral linear fixator [BLF], 4-ring circular external fixator [CEF], and hybrid fixator [HF]) were made using mild (low carbon) steel implants plated with nickel and cadaveric buffalo tibiae. After ESF application, a 1 cm mid-diaphyseal gap was created. Constructs were loaded to failure, on a materials testing machine, in axial compression (n=5/ESF type) and craniocaudal bending (n=3/ESF type). In addition, 3 CEF constructs were tested in intact tibiae under craniocaudal bending. RESULT: In compression, HF was the strongest and most rigid construct; yield load was significantly higher for HF than for BLF or CEF. Under bending, both CEF and HF had similar strength and modulus of elasticity. Strength for BLF was higher than CEF and HF, whereas the reverse was true for modulus of elasticity. CONCLUSIONS: ESF made from mild steel for use in large ruminants could withstand相似文献   

17.
OBJECTIVES: To compare the axial mechanical stability of 3 circular external fixators systems with and without hemispheric washers. STUDY DESIGN: Experimental study. METHODS: The axial stiffness and load necessary to produce 0.5 and 1 mm of displacement of 10 circular external fixator constructs from 3 manufacturers were tested on a materials testing machine. The constructs tested included the Small Bone fixator (SBF; Hofmann S.a.S., Monza, Italy), the IMEX ring fixator (IMEX Inc., Longview, TX), and the Multiplanar C-Fix (MCF; PanVet Distribuzione, Seriate, Italy). Five configurations were tested for each construct: (1) conventional nut fixation, (2) hemispheric washer fixation with connecting rods offset by 0, (3) 1, and (4) 2 holes, and (5) with a ring placed at maximum angulation. RESULTS: The loads resisted at 0.5 and 1 mm of displacement did not differ when frame configurations were compared (P =.25733 and.33769, respectively). The linear stiffness of the following configurations were decreasingly stiff: standard constructs, hemispheric washers with connecting rods perpendicular to rings, hemispheric washers with connecting rods offset by 1 hole, hemispheric washers with connecting rods offset by 2 holes, and ring offset in relation to bone model. The SBF constructs tested were 34% and 41% more rigid than the IMEX and MCF constructs tested despite the larger diameter of the connecting rods for the IMEX frames (6 mm) compared with the SBF frames (5 mm). The IMEX constructs tested were 6% more rigid than the MCF constructs tested. CONCLUSIONS: Adding hemispheric washers and angling connecting rods in relation to rings did not influence the loads resisted at 0.5 and 1 mm displacement but decreased construct stiffness. CLINICAL RELEVANCE: The use of hemispheric washers had minor effects on the biomechanical performance of fixator frames tested in this study when used to angle a ring in relation to connecting rods for circular external fixators.  相似文献   

18.
OBJECTIVE: To evaluate a dorsoproximal extra-articular approach for insertion of 8.25-mm, solid-titanium, intramedullary (IM) interlocking nails into ostectomized foal third metacarpal (MC3) and third metatarsal (MT3) bones; to compare the monotonic mechanical properties of IM nail constructs with paired intact bones; and to determine the effects of age, body weight, fore- or hindlimb, and left or right limb on the mechanical testing variables. ANIMAL OR SAMPLE POPULATION: Twenty bone pairs (10 MC3, 10 MT3) collected from 10 foals of various weights and ages. METHODS: One bone from each pair was randomly selected to be ostectomized and stabilized using an 8.25-mm, solid-titanium IM nail, and four 3.7-mm titanium interlocking screws (construct). Constructs and contralateral intact bone specimens were tested in axial compression and palmaro-/plantarodorsal (PD) 4-point bending. Monotonic mechanical properties were compared between intact specimens and constructs with an ANOVA; significance was set at P <.05. RESULTS: Nail insertion caused bone failure in 6 MC3 and 2 MT3. In general, mean mechanical testing values indicated that intact specimens were significantly stronger and stiffer than constructs for all age and weight ranges when tested in compression and PD 4-point bending (P <.05). Bone strength and stiffness of intact specimens tested in compression and bending tended to increase linearly with age and weight. CONCLUSION: IM interlocking nail fixation of gap-ostectomized MC3 and MT3 with 8.25-mm IM nails and 3.7-mm interlocking screws did not achieve sufficient strength or stiffness to be recommended as the sole means of repair for comminuted MC3 and MT3 fractures in young foals. CLINICAL RELEVANCE: IM interlocking nail fixation of foal cannon bone fractures may be useful to decrease soft-tissue disruption at the fracture site; however, there is a risk of bone failure associated with extra-articular insertion. This method should be combined with other forms of external coaptation for added stability in axial compression and PD bending.  相似文献   

19.
Repair of a comminuted, spiral oblique, proximal diaphyseal femoral fracture in a 7-day-old calf was achieved by use of an intramedullary pin, cerclage wires, and external fixator. Six stainless steel wires were used for full cerclage to secure a long butterfly fragment and multiple incomplete and complete nondisplaced fragments to the femur in order to create 2 principal fragments. Axial alignment and resistance to bending was provided by a round, double-pointed, end-threaded intramedullary pin (6.35 mm in diameter), which was inserted in a retrograde fashion. A type-1, double-connecting-bar external fixator, using 4 round pins (4.8 mm in diameter), was used to provide supplemental stabilization against shear and torsional forces. At 45 days after surgery, healing at the fracture site was seen on radiography of the limb, and the external fixator was removed. Eight months after surgery, the calf had a normal gait.  相似文献   

20.
OBJECTIVE: To evaluate clinical findings, complications, and outcome of horses and foals with third metacarpal, third metatarsal, or phalangeal fractures that were treated with transfixation casting. DESIGN: Retrospective case series. Animals-29 adult horses and 8 foals with fractures of the third metacarpal or metatarsal bone or the proximal or middle phalanx. PROCEDURES: Medical records were reviewed, and follow-up information was obtained. Data were analyzed by use of logistic regression models for survival, fracture healing, return to intended use, pin loosening, pin hole lysis, and complications associated with pins. RESULTS: In 27 of 35 (77%) horses, the fracture healed and the horse survived, including 10 of 15 third metacarpal or metatarsal bone fractures, 11 of 12 proximal phalanx fractures, and 6 of 8 middle phalanx fractures. Four adult horses sustained a fracture through a pin hole. One horse sustained a pathologic unicortical fracture secondary to a pin hole infec-tion. Increasing body weight, fracture involving 2 joints, nondiaphyseal fracture location, and increasing duration until radiographic union were associated with horses not returning to their intended use. After adjusting for body weight, pin loosening was associated with di-aphyseal pin location, pin hole lysis was associated with number of days with a transfixation cast, and pin complications were associated with hand insertion of pins. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that transfixation casting can be successful in managing fractures distal to the carpus or tarsus in horses. This technique is most suitable for comminuted fractures of the proximal phalanx but can be used for third metacarpal, third metatarsal, or middle phalanx fractures, with or without internal fixation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号