首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Objective

To evaluate intraoperative and postoperative efficacy of ultrasound (US)-guided femoral (FN) and obturator (ON) nerves block, in the iliopsoas muscle compartment (IPM), using an in-plane technique.

Study design

Anatomical research and randomized, prospective, ‘blinded’ clinical study.

Animals

Six dog cadavers and 20 client-owned dogs undergoing tibial plateau levelling osteotomy (TPLO) surgery.

Methods

In phase 1, anatomical dissections and US imaging of the IPM were performed to design an US-guided nerve block involving the FN and ON simultaneously. The technique was considered successful if new methylene blue solution injection (0.1 mL kg?1) stained FN–ON for ≥2 cm. In phase 2, the US-guided nerve block designed in phase 1, combined with US-guided sciatic nerve (ScN) block, was performed in 20 dogs undergoing TPLO surgery. Patients were assigned randomly to one of two treatment groups: ropivacaine 0.3% (R3, n = 10) and ropivacaine 0.5% (R5, n = 10) at a volume of 0.1 mL kg?1 for each nerve block. Intraoperative success rate (fentanyl requirement < 2.1 mcg kg?1 hour?1) and postoperative pain score [Short Form-Glasgow Composite Measure Pain Scale (SF-GCMPS) ≥ 5/20] were evaluated.

Results

In phase 1, the US image of FN–ON was detected between L6 and L7. In-plane needling technique produced a staining of >4 cm in six of six cases. No abdominal or epidural dye spread was found. In phase 2, median fentanyl infusion rates were 0.5 (0.0–0.9) μg kg?1 hour?1 for R3 and 0.6 (0.0–2.2) μg kg?1 hour?1 for R5. At 9 and 11 hours after the peripheral nerve blocks, an SF-GCMPS ≥ 5 was observed for R3 and R5, respectively.

Conclusions and clinical relevance

The US-guided FN–ON block in the IPM, using an in-plane technique, combined with US-guided ScN block, provided sufficient analgesia to minimize the use of fentanyl during TPLO surgery. A longer postoperative analgesia was observed in group R5 compared with R3.  相似文献   

2.
ObjectivesTo evaluate the efficacy of ultrasound‐guidance in nerve blockade of the sciatic and saphenous nerves in dogs and to determine if this technique could allow lower anaesthetic doses to be used with predictable onset and duration of effect.Study designProspective randomized (for dose and leg) blinded experimental crossover trial with 10 day washout period.AnimalsSix healthy female Hound dogs aged 12.3 ± 0.5 (mean ± SD) months and weighing 18.7 ± 0.8 (mean ± SD) kg.MethodsAn ultrasound‐guided, perineural injection was used with saline at 0.2 mL kg?1 (Sal) or bupivacaine 0.5% at 0.05 (low dose; LD), 0.1 (medium dose; MD), or 0.2 (high dose; HD) mL kg?1, divided 2/3 at the sciatic nerve and 1/3 at the saphenous nerve. Blocks were performed using dexmedetomidine sedation with atipamezole reversal immediately after completion of the injections. Motor/proprioceptive and sensory functions were scored using a 0–8 and a 0–2 scale, respectively. Clinically relevant blocks were defined as a motor score ≥2 and sensory score ≥1. Nonparametric methods were used for statistical analysis.ResultsNo adverse effects were noted. There was a significant difference between the treatments with bupivacaine and the saline control, but not between the three bupivacaine treatments. Success rates of clinically relevant sciatic and saphenous blocks were both 67% (CI 95% 0.22–0.96). Onset and duration of the blocks were variable; 20–160 and 20–540 minutes, respectively.Conclusion and clinical relevanceNone of the bupivacaine doses was significantly superior, though there was a tendency for a better block with the high bupivacaine dose. Either the technique or the doses used need further modification before this method will be useful in clinical practice.  相似文献   

3.
ObjectiveTo describe the nerve stimulator-guided sciatic-femoral nerve block in raptors undergoing surgical treatment of pododermatitis.Study designProspective clinical trial.AnimalsFive captive raptors (Falco peregrinus) aged 6.7 ± 1.3 years.MethodsAnaesthesia was induced and maintained with isoflurane in oxygen. The sciatic-femoral nerve block was performed with 2% lidocaine (0.05 mL kg−1 per nerve) as the sole intra-operative analgesic treatment. Intraoperative physiological variables were recorded every 10 minutes from endotracheal intubation until the end of anaesthesia. Assessment of intraoperative nociception was based on changes in physiological variables above baseline values, while evaluation of postoperative pain relied on species-specific behavioural indicators.ResultsThe sciatic-femoral nerve block was feasible in raptors and the motor responses following electrical stimulation of both nerves were consistent with those reported in mammalian species. During surgery no rescue analgesia was required. The anaesthesia plane was stable and cardiorespiratory variables did not increase significantly in response to surgical stimulation. Iatrogenic complications, namely nerve damage and local anaesthetic toxicity, did not occur. Recovery was smooth and uneventful. The duration (mean ± SD) of the analgesic effect provided by the nerve block was 130 ± 20 minutes.Conclusion and clinical relevanceThe sciatic-femoral nerve block as described in dogs and rabbits can be performed in raptors as well. Further clinical trials with a control groups are required to better investigate the analgesic efficacy and the safety of this technique in raptors.  相似文献   

4.
Objective To describe an ultrasound‐guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Study design Prospective experimental trial. Animals Four hound‐cross dogs aged 2 ± 0 years (mean ± SD) weighing 30 ± 5 kg and four Beagles aged 2 ± 0 years and weighing 8.5 ± 0.5 kg. Methods Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation‐guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Results Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Conclusions and clinical relevance Ultrasound‐guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.  相似文献   

5.
Objective To develop an ultrasound‐guided technique for retrobulbar nerve block in horses, and to compare the distribution of three different volumes of injected contrast medium (CM) (4, 8 and 12 mL), with the hypothesis that successful placement of the needle within the retractor bulbi muscle cone would lead to the most effective dispersal of CM towards the nerves leaving the orbital fissure. Study design Prospective experimental cadaver study. Animals Twenty equine cadavers. Methods Ultrasound‐guided retrobulbar injections were performed in 40 cadaver orbits. Ultrasound visualization of needle placement within the retractor bulbi muscle cone and spread of injected CM towards the orbital fissure were scored. Needle position and destination of CM were then assessed using computerized tomography (CT), and comparisons performed between ultrasonographic visualization of orbital structures and success rate of injections (intraconal needle placement, CM reaching the orbital fissure). Results Higher scores for ultrasound visualization resulted in a higher success rate for intraconal CM injection, as documented on the CT images. Successful intraconal placement of the needle (22/34 orbits) resulted in CM always reaching the orbital fissure. CM also reached the orbital fissure in six orbits where needle placement was extraconal. With 4, 8 and 12 mL CM, the orbital fissure was reached in 16/34, 23/34 and 28/34 injections, respectively. Conclusion and clinical relevance The present study demonstrates the use of ultrasound for visualization of anatomical structures and needle placement during retrobulbar injections in equine orbits. However, this approach needs to be repeated in controlled clinical trials to assess practicability and effectiveness in clinical practice.  相似文献   

6.
ObjectiveTo determine the effect of blocking the obturator nerve in addition to performing femoral nerve and sciatic nerve blocks on intraoperative nociception in dogs undergoing unilateral tibial plateau levelling osteotomy (TPLO) surgery.Study designProspective, blinded, randomized, placebo-controlled, clinical comparison.AnimalsA total of 88 client-owned dogs undergoing unilateral TPLO surgery (100 procedures).MethodsDogs were randomly assigned to either group FSO (femoral, sciatic and obturator nerve blocks) [n = 50; ropivacaine 0.75% (0.75 mg kg–1)] or group FSP (femoral, sciatic and placebo) [n = 50; ropivacaine 0.75% (0.75 mg kg–1) femoral and sciatic nerve blocks plus saline solution 0.9% (0.1 mL kg–1) as a placebo injection around the obturator nerve]. The anaesthetic protocol was standardized. Data collection included intraoperative cardiopulmonary variables and opioid consumption. Rescue analgesia consisted of an intravenous bolus of fentanyl (2 μg kg–1) and was administered when a change in cardiopulmonary variables (20% increase in mean arterial pressure or heart rate) was attributed to a sympathetic stimulus. Data were analysed using generalized linear mixed models, cross tables and multivariable binary logistic regression. Results were expressed as adjusted odds ratios with 95% confidence intervals and Wald p values (α = 0.05).ResultsThere were no clinically relevant differences between groups in intraoperative cardiopulmonary variables and need for rescue analgesia. The requirement for rescue analgesia was significantly higher in dogs with a body weight >34 kg.Conclusions and clinical relevanceAnaesthesia of the obturator nerve in addition to the femoral and sciatic nerves was not associated with clinically significant differences in cardiopulmonary variables or a reduced need for rescue analgesia. Therefore, the clinical benefit of an additional obturator nerve block for intraoperative antinociception in dogs undergoing unilateral TPLO surgery using the described anaesthetic regimen is low.  相似文献   

7.
8.
Understanding the normal course and optimizing visualization of the canine peripheral nerves of the lumbar plexus, in particular the sciatic and the femoral nerves, is essential when interpreting images of patients with suspected peripheral neuropathies such as inflammatory or neoplastic conditions. The purpose of this prospective, anatomic study was to describe the magnetic resonance imaging (MRI) anatomy of the normal canine femoral and sciatic nerves and to define the sequences in which the nerves are best depicted. A preliminary postmortem cadaver study was performed to determine optimal sequences and imaging protocol. In a second step the optimized technique was implemented on 10 healthy Beagle dogs, included in the study. The applied protocol included the following sequences: T1‐weighted, T2‐weighted, T2‐Spectral Attenuated Inversion Recovery, T1‐weighted postcontrast and T1‐Spectral Presaturated Inversion Recovery postcontrast. All sequences had satisfactory signal‐to‐noise ratio and contrast resolution in all patients. The sciatic and femoral nerves were seen in all images. They were symmetric and of homogeneous signal intensity, being iso‐ to mildly hyperintense to muscle on T2‐weighted, mildly hyperintense in T2‐Spectral Attenuated Inversion Recovery, and iso‐ to mildly hypointense in T1‐weighted images. No evidence of contrast enhancement in T1‐weighted and T1‐Spectral Presaturated Inversion Recovery postcontrast sequences was observed. The anatomic landmarks helpful to identify the course of the femoral and sciatic nerves are described in detail. This study may be used as an anatomical reference, depicting the normal canine femoral and sciatic nerves at 3 Tesla MRI.  相似文献   

9.
ObjectiveTo describe a new approach to block the femoral nerve and to evaluate the distribution of a dye injected into the psoas compartment using a new femoral nerve block approach; to assess its clinical application, when combined with a sciatic nerve block, for surgical anaesthesia/analgesia of the pelvic limb in dogs.Study designProspective anatomical, research and clinical study.AnimalsTwo dog cadavers; two dogs that had to be euthanized for reasons unrelated to this study, and 15 dogs undergoing pelvic limb orthopaedic surgery.MethodsPhase 1: anatomical dissections were performed to determine a simple method to approach the femoral nerve within the psoas compartment. Phase 2: 0.1 mL kg?1 of a lidocaine-new methylene blue solution was injected bilaterally after successful electrolocation of the femoral nerve in two anaesthetized dogs. Colorant spread was evaluated through femoral nerve dissections after euthanasia. Phase 3: in 15 dogs undergoing pelvic limb orthopaedic surgery under light general anaesthesia with isoflurane, intra-operative analgesic effect (cardiovascular responses) and early post-operative pain score, of the novel femoral nerve block combined with a sciatic nerve block as the sole analgesic protocol, were evaluated.ResultsPhase 1: a needle inserted from the lateral aspect of the lumbar muscles, cranially to the iliac crest and with a 30–45° caudo-medial direction, reaches the femoral nerve in the caudal portion of the psoas compartment. Phase 2: Four femoral nerves were stained >2 cm. Phase 3: this novel lateral pre-iliac approach, combined with the sciatic nerve block, blunted the intra-operative cardiovascular response to surgical stimulation in 13 out of 15 anaesthetized dogs. In addition, rescue analgesia was not required in the early post-operative 2-hour period.Conclusion and clinical relevanceThe lateral pre-iliac femoral nerve block technique may provide adequate intra- and early post-operative pain relief in dogs undergoing pelvic limb surgery.  相似文献   

10.
ObjectiveTo determine the needle‐to‐nerve distances during electrical nerve location in dogs at different currents and pulse duration using a peripheral nerve stimulator (PNS) under ultrasound control (US), and the minimal electrical thresholds (MET) necessary to obtain a motor response (MR) after achieving needle‐to‐nerve contact.Study designProspective in vivo experimental trial in a clinical settingAnimalsThirty dogs, scheduled for locoregional anaesthesia of the sciatic nerve.MethodsNeedle‐to‐nerve distance was measured ultrasonographically after obtaining the MR of sciatic nerve with 2, 1 and 0.5 mA and pulse duration 0.1 ms (NS0.1). Thereafter the needle was placed in contact with the nerve and MET was determined. The procedure was repeated with 0.3 ms (NS0.3). Finally the needle was reintroduced to contact the sciatic nerve guided only by US, thus MET‐US was determined. Data were analysed using Kruskal–Wallis or Mann–Whitney tests.ResultsNeedle‐to‐nerve distances were greater when MR was obtained with 2 mA than with 1 and 0.5 mA at 0.1 and 0.3 ms. No significant differences were observed between the needle‐to‐nerve distances using 0.1 or 0.3 ms.The MET [median (range)] was 0.4 (0.18–1.3) mA in NS0.1, 0.32 (0.12–0.8) mA in NS0.3; while MET‐US was 0.7 (0.32–1.5) mA. When the needle contacted the nerve, the MR achieved with currents below 0.3 mA was obtained in 17.2, 40 and 0% of cases using NS0.1, NS0.3 and US respectively.Conclusions and clinical relevanceThe electrical current necessary to obtain a MR decreased as the needle moved towards the nerve. However when the needle tip contacted the nerve, an MR with low current intensity could not be obtained. Thus the absence of motor response at currents below 0.3 mA cannot rule out needle‐epineurium contact. When ultrasound is combined with PNS, it is more important to assess the correct needle position than searching for an MR at low currents.  相似文献   

11.
12.
ObjectivesTo describe the ultrasound-guided rectus sheath block technique and the anatomical spread of two volumes of methylene blue injection in dog cadavers.Study designBlinded, prospective, experimental cadaveric study.AnimalsA total of eight dog cadavers weighing 8.9 ± 1.6 kg.MethodsUltrasound-guided rectus sheath injections were performed bilaterally 1 cm cranial to the umbilicus using 0.25 mL kg–1 (low volume; LV) and 0.50 mL kg–1 (high volume; HV) of 0.5% methylene blue dye. A total of 16 hemiabdomens were injected. The ultrasound image quality of the muscular and fascial plane landmarks and needle visualization were scored using a standardized scale. Cadavers were dissected to determine the distribution of the dye and to assess staining of ventral branches of the spinal nerves.ResultsFewer ventral spinal nerve branches were stained in the LV group than in the HV group, at 2.00 ± 0 and 2.90 ± 0.83, respectively (p < 0.01). Ventral branches of thoracic (T) and lumbar (L) spinal nerves (T10, T11, T12, T13 and L1) were stained 25%, 100%, 75%, 25% and 0% of the time in LV group and 12.5%, 87.5%, 100.0%, 75.0% and 13.0% in HV group. A lesser extent of cranial–caudal dye distribution was observed in the LV group than in the HV group (7.1 ± 1.8 cm and 9.2 ± 1.8 cm, respectively; p = 0.03). There was no significant difference in medial–lateral spread of dye, number of test doses or ultrasound image quality scores between groups.Conclusions and clinical relevanceThe results of this study suggest that, on an anatomical basis, this easily performed block has the potential to provide effective abdominal wall analgesia for the ventral midline. This study supports the potential of the rectus sheath block for abdominal procedures, and further investigations on its clinical efficacy are warranted.  相似文献   

13.

Objective

To describe a novel ultrasound-guided posterior extraconal block in the dog.

Study design

Prospective experimental cadaveric study.

Animals

A total of 13 Beagle Cross cadaver heads.

Methods

After describing the ultrasound bony landmarks and posterior extraconal local regional technique in one head, 12 heads were used to evaluate the spreading of contrast and evaluate potential complications. A 5–8 MHz microconvex ultrasound probe was positioned caudal to the orbital ligament, with the beam orientated transversely, and then tilted caudally until the orbital fissure was visualized. After identifying the bony structures consistent with the orbital fissure, a needle was advanced using an in-plane technique and 0.5 mL of a 50:50 mixture of iohexol and methylene blue was injected. Computed tomography (CT) and dissection were used to evaluate successful injections and potential complications. The injection was considered successful if radiopaque contrast medium was 5 mm from the orbital fissure. Potential complications were defined as the presence of radiopaque contrast within the globe or the intracalvarial tissues.

Results

The CT images confirmed contrast at the target site in 15/24 (63%) of the injections. Only two injections were found in the temporalis muscle; the rest of the injections were located in the extraconal space. No potential complications such as intracranial spreading of contrast, intravascular or intraocular injection were found.

Conclusions and clinical relevance

The technique can deliver contrast close to the main nerves which provide sensory and motor innervation to the eye. Further studies are needed to evaluate this technique in clinical cases.  相似文献   

14.
ObjectiveTo describe an ultrasound-guided lateral pre-iliac (LPI) and parasacral (PS) approach in feline cadavers (phase I) and compare the perioperative analgesic use and complications in cats administered LPI and PS blocks (group PNB) or epidural anesthesia (group EPI) for pelvic limb surgery (phase II).Study designExperimental uncontrolled, anatomic and retrospective cohort study.AnimalsA group of eight feline cadavers and 52 medical records.MethodsBilateral LPI and PS approaches with 0.1 mL kg–1 of dye to stain the femoral and obturator nerves and the lumbosacral trunk, respectively, were performed on each cadaver. Nerve staining effect was evaluated upon dissections (phase I). Perioperative analgesics use, and complication rates were retrospectively compared between groups PNB and EPI (phase II). Continuous data were compared using the Mann–Whitney U test and the prevalence of events with Fisher’s exact test. Differences were considered significant when p < 0.05.ResultsDissections revealed that the LPI approach stained 94% and 75% of the femoral and obturator nerves, respectively. The PS approach stained 100% of the lumbosacral trunks. Cats enrolled in group PNB (n = 23) were administered lower doses of intraoperative opioids than those in group EPI (n = 25) (p = 0.006). Intraoperative rescue analgesia was required in 60% and 17.4% of cats enrolled in groups EPI and PNB, respectively (p = 0.003). Group PNB required more intraoperative anticholinergics than group EPI (p = 0.02). There were no differences in postoperative pain scores, analgesic use and complication rates.Conclusions and clinical relevanceThe ultrasound-guided LPI and PS approach stained the femoral/obturator nerves and the lumbosacral trunk, respectively, in feline cadavers. Furthermore, PNB was associated with lower intraoperative opioid use and similar postoperative pain and analgesic use compared with epidural anesthesia in a cohort of cats undergoing surgery of the pelvic limb.  相似文献   

15.
ObjectiveTo determine the influence on the distribution of the volume of a local anaesthetic-methylene blue solution at three different nerve block sites in the dog.Study designRandomized, controlled, blinded experimental trial.Animals23 hound-cross dogs weighing 16–40 kg and aged 2 ± 0 years (mean ± SD).MethodsDogs were anaesthetized and randomly assigned to three groups of seven or eight dogs each, based on volume administered: low, medium and high volume (L, M and H). Using electrolocation, the injection was performed after a positive response was elicited (flexion of the elbow for the brachial plexus block, quadriceps contractions for the lumbar plexus and dorsiflexion/plantar extension of the foot for the sciatic nerve block). At the brachial plexus site, groups L, M and H received 0.075, 0.15 and 0.3 mL kg−1, respectively. At the lumbar plexus site, groups L, M and H received 0.1, 0.2 and 0.4 mL kg−1, respectively. At the proximal sciatic nerve site, groups L, M and H received 0.05, 0.1 and 0.25 mL kg−1, respectively. Necropsies were performed immediately following euthanasia. Staining of ≥2 cm along the nerve was considered sufficient; the proportions sufficient were compared with Fisher's exact test. The volume was recommended when all the relevant nerves were stained sufficiently in all or all but one of the dogs within the group.ResultsIn the brachial plexus, only in group H were all the nerves stained sufficiently. In the lumbar plexus site, no statistical difference was found, but we suggest the H group volume to balance sufficient and excessive staining. At the sciatic nerve site, all volumes tested produced sufficient staining in all (or all but one) dogs.Conclusions and clinical relevanceVolumes of 0.3 and 0.05 mL kg−1 produced sufficient distribution for performing brachial plexus, and sciatic nerve blocks, respectively. Additionally, a volume of 0.4 mL kg−1 might also be adequate for a lumbar plexus block (no statistical significance was reached).  相似文献   

16.

Objective

To describe a transorbital approach to the maxillary nerve block in dogs and compare it with a traditional approach.

Study design

Prospective, randomized controlled study.

Animals

Heads from 17 euthanized dogs (10 Greyhounds, three Border Collies and four of mixed breed).

Methods

A volume of 1 mL of methylene blue dye was injected by each of two techniques, a traditional percutaneous approach and a transorbital approach to the maxillary nerve block. Both techniques were used on each head, alternating the left and right sides after random assignment to the first head. The heads were dissected to reveal the maxillary nerve and the length of nerve stained was measured.

Results

There was no significant difference (p = 0.67) in the proportion of nerves stained for a length >6 mm by either technique (88.2% transorbital versus 82.3% percutaneous). The mean length of nerve stained did not differ significantly between the techniques (p = 0.26).

Conclusions and clinical relevance

The transorbital approach to the maxillary nerve block described here presents a viable alternative to the traditional percutaneous approach. Further study is required to confirm its efficacy and safety under clinical conditions.  相似文献   

17.
18.
ObjectiveTo compare the perioperative effects and pharmacoeconomics of peripheral nerve blocks (PNBs) versus fentanyl target-controlled infusion (fTCI) in dogs undergoing tibial plateau levelling osteotomy (TPLO).Study designRandomized clinical study.AnimalsA total of 39 dogs undergoing unilateral TPLO.MethodsAfter acepromazine and methadone, anaesthesia was induced with propofol and maintained with isoflurane. Dogs were allocated to group fTCI [target plasma concentration (TPC) 1 ng mL–1] or group PNB (nerve stimulator-guided femoral-sciatic block using 0.2 and 0.1 mL kg–1 of levobupivacaine 0.5%, respectively). If nociceptive response occurred, isoflurane was increased by 0.1%, and TPC was increased by 0.5 ng mL–1 in group fTCI; a fentanyl bolus (1 μg kg–1) was administered in group PNB. During the first 24 postoperative hours, methadone (0.2 mg kg–1) was administered intramuscularly according to the Short Form Glasgow Composite Pain Scale, or if pain was equal to 5/24 or 4/20 for two consecutive assessments, or if the dog was non-weight bearing. The area under the curve (AUC) of pain scores, cumulative postoperative methadone requirement, food intake and pharmacoeconomic implications were calculated.ResultsIncidence of bradycardia (p = 0.025), nociceptive response to surgery (p = 0.041) and AUC of pain scores (p < 0.0001) were greater in group fTCI. Postoperatively, 16/19 (84.2%) and eight/20 (40%) dogs in groups fTCI and PNB, respectively, were given at least one dose of methadone (p = 0.0079). Food intake was greater in group PNB (p = 0.049). Although total cost was not different (p = 0.083), PNB was more cost-effective in dogs weighing >15 kg.Conclusions and clinical relevanceCompared with group fTCI, incidence of bradycardia, nociceptive response to surgery, postoperative pain scores, cumulative methadone requirement were lower, and food intake was greater in group PNB, with an economic advantage in dogs weighing >15 kg.  相似文献   

19.
ObjectiveTo examine the anatomy of the lumbar epaxial region and to describe two different ultrasound-guided approaches for the lumbar erector spinae plane (ESP) block in dogs.Study designAn anatomical and experimental cadaver study.AnimalsA group of 19 canine cadavers.MethodsThe anatomy was described following dissection of two cadavers. Bilateral ultrasound-guided ESP injections with 0.4 mL kg1 of contrast dye were performed in 17 adult Beagle cadavers using either transversal (TVS) or parasagittal (PST) approaches. Computed tomography was performed to measure the total length of the contrast dye column and the epidural, intravascular, hypaxial and intra-abdominal migration. Dissections were performed to assess the spread of the contrast dye and to determine the degree of staining of the dorsal branches of the spinal nerves (DBSN). Mann–Whitney U and chi-square tests were used to compare data between groups.ResultsUsing both techniques, the contrast dye was observed within the ESP compartment. There was no difference in the total length of the contrast dye column between TVS and PST approaches (p = 0.056). Using the TVS approach, multisegmental staining of the DBSN was visible with 100% (17/17) of injections, while complete staining of the DBSN was achieved at 94% of the injection sites. Using the PST approach, these values were 29% (5/17) and 23% (4/17), respectively. The TVS approach stained more DBSN than the PST approach (p = 0.001), with a median (range) of 2 (2–3) versus 0 (0–3) DBSN, respectively. Using the TVS approach, epidural and intravascular migration were present in 2/17 (p = 0.485) and 3/17 (p = 0.227) injections, respectively.Conclusions and clinical relevanceBoth ultrasound-guided approaches resulted in a spread of the contrast dye within the ESP compartment. Although there were no differences in the total length of the contrast dye column, the TVS approach was superior to the PST approach in staining DBSN.  相似文献   

20.
ObjectiveTo describe a novel in-plane ultrasound (U/S)-guided temporal approach to peribulbar block in dogs.Study DesignProspective experimental cadaver study.AnimalsA group of 10 Beagle cadavers.MethodsAfter describing the U/S anatomy, peribulbar injection was performed bilaterally in 10 thawed Beagle cadavers by two randomly assigned operators. A 5–8 MHz microconvex U/S probe was positioned caudal to the orbital ligament in the longitudinal plane. Using an in-plane technique, methylene blue dye was injected in five dogs (10 eyes total), while methylene blue dye and iohexol contrast mixture (50:50) were injected in the remaining five dogs. Injection volume was 0.2 mL cm?1 of cranial length. A computed tomography (CT) scan was performed on dogs injected with dye and contrast to identify spread of contrast. Dissection to visualize dye spread in the orbit was performed in all dogs. Injection success was defined as spread of contrast into the peribulbar space. The pattern of distribution of contrast-dye was also assessed. Comparisons between operator and bilateral injections were assessed using a Student t test (p < 0.05). All other data are reported as number (n/N) and percentage (%).ResultsPeribulbar spread was noted in 19/20 injections (95%) on dissection. CT imaging (five dogs) illustrated peribulbar contrast spread in 9/10 injections (90%), with mixed peribulbar/retrobulbar spread for the remaining injection. Contrast was present at the rostral alar foramen in 4/10 (40%) injections, orbital fissure in 5/10 (50%), oval foramen in 1/10 (10%), maxillary nerve in 3/10 (30%) and intracranial in 5/10 (50%). Coverage of the maxillary nerve was noted on 3/20 (15%) injections on dissection. No further dye spread was noted.Conclusions and clinical relevanceThis technique demonstrated peribulbar spread of injectate in 100% of injections for the 10 canine cadavers studied. Further studies are required to evaluate this technique clinically.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号