首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Milk is typically screened for beta-lactam antibiotics by nonspecific methods. Although these methods are rapid and sensitive, they are not quantitative and can yield false positive findings. A sensitive and specific method for the quantitation and mass spectral confirmation of five beta-lactam and two cephalosporin antibiotics commonly or potentially used in the dairy industry is described using high-performance liquid chromatography with tandem mass spectrometry. The antibiotics studied were ampicillin, amoxicillin, penicillin G, penicillin V, cloxacillin, cephapirin, and ceftiofur. The antibiotics were extracted from milk with acetonitrile, followed by reversed-phase column cleanup. The extract was analyzed by liquid chromatography coupled with a mass spectrometer, using a water/methanol gradient containing 1% acetic acid on a C-18 reversed-phase column. Determination was by positive ion electrospray ionization and ion trap tandem mass spectrometry. Quantitation was based on the most abundant product ions from fragmentation of the protonated ion for amoxicillin, cephapirin, ampicillin, and ceftiofur and on the fragmentation of the sodium adduct for penicillin G, penicillin V, and cloxacillin. The method was validated at the U.S. FDA tolerance or safe level and at 5 or 2.5 ng/mL for these compounds in bovine milk. Theoretical method detection limits in milk based on a 10:1 signal to noise ratio were 0.2 ng/mL (ampicillin), 0.4 ng/mL (ceftiofur), 0.8 ng/mL (cephapirin), 1 ng/mL (amoxicillin and penicillin G), and 2 ng/mL (cloxacillin and penicillin V) using a nominal sample size of 5 mL.  相似文献   

2.
A sensitive liquid chromatographic method was developed for determining oxacillin, cloxacillin, and dicloxacillin (simultaneously), and penicillin G, amoxicillin, carbenicillin, and ticarcillin in canine and/or equine serum. The method involves filtering diluted serum through a 30,000 molecular weight cut-off filter and separating penicillins from other serum components by ion-pair liquid chromatography using a reverse-phase column eluted with acetonitrile-water solutions. The ultraviolet absorbance of the column effluent was monitored at 230 nm. Recoveries of oxacillin, cloxacillin, dicloxacillin, and penicillin G (spiked at 2.5 micrograms/mL), amoxicillin (spiked at 5 micrograms/mL), and carbenicillin and ticarcillin (spiked at 10 micrograms/mL) from canine and equine serums ranged from 78.3 to 104.4% with coefficients of variation ranging from 3.35 to 5.95%. The limit of detection for these penicillins was 0.02-0.05 microgram/mL.  相似文献   

3.
A confirmatory assay able to unambiguously identify and quantify 10 approved-for-use beta-lactam antibiotics in milk below stipulated U.S. and EU tolerance levels is presented. beta-Lactams are extracted from 10 mL of intact milk by a Carbograph 4 cartridge. After solvent removal, residue reconstitution, and filtration, a completely transparent and uncolored extract is injected into a liquid chromatography -mass spectrometry (LC-MS) instrument equipped with an electrospray (ES) ion source and a single quadrupole. During the chromatographic run, the ES/MS system is operated first in the positive-ion mode (PI) and then in the negative-ion (NI) mode. This is done to circumvent matrix interferences resulting in remarkable signal weakening of the last-eluted analytes, when detecting them as [M+H]+ adduct ions. MS data acquisition is performed by a time-scheduled three-ion selected ion monitoring program. At the 5 ng/mL level, recoveries of the beta-lactams are between 70 (nafcillin) and 108% (cephalin), with relative standard deviations ranging between 5 (oxacillin) and 11% (amoxicillin and ceftiofur). The response of the ES/MS detector is linearly related to injected amounts up to 500 ng, irrespective of the chemical characteristics of the beta-lactams and the acquisition mode selected (PI or NI modes). Limits of quantification, based on a minimal value of the signal-to-noise ratio of 10, were estimated to be within 0.4 (cephalin) and 3 ng/mL (dicloxacillin). Analyses of milk samples taken after intramammary application of amoxicillin showed that 1.2 ng/mL of this penicillin was still present 6 days after treatment. At this concentration level, the identification power of the method is not weakened, as signals of the three product ions of amoxicillin are still well distinguishable from the background noise.  相似文献   

4.
The development of a sensitive flow-though immunosensor for the analysis of the mycotoxin zearalenone in cereal samples is described. The sensor was completely automated and was based on a direct competitive immunosorbent assay and fluorescence detection. The mycotoxin competes with a horseradish-peroxidase-labeled derivative for the binding sites of a rabbit polyclonal antibody. Control pore glass covalently bound to Prot A was used for the oriented immobilization of the antibody-antigen immunocomplexes. The immunosensor shows an IC(50) value of 0.087 ng mL(-1) (RSD = 2.8%, n = 6) and a dynamic range from 0.019 to 0.422 ng mL(-1). The limit of detection (90% of blank signal) of 0.007 ng mL(-1) (RSD = 3.9%, n = 3) is lower than previously published methods. Corn, wheat, and swine feed samples have been analyzed with the device after extraction of the analyte using accelerated solvent extraction (ASE). The immunosensor has been validated using a corn certificate reference material and HPLC with fluorescence detection.  相似文献   

5.
A liquid chromatographic (LC) method was developed for quantitative determination of cephapirin residues in milk that also resolved cephapirin from ampicillin, cloxacillin, and penicillin G. Diluted milk was passed through a C18 cartridge on which the cephapirin was adsorbed; then, interfering material was removed by washing with water and methylene chloride and cephapirin residues were eluted with methanol-acetonitrile (25 + 75). After drying, residues were dissolved in the mobile phase for injection. The LC system had an ultrasphere-ODS column with RP-18 Spheri-10 guard column and a UV detector with a 254 nm filter. The mobile phase was 85% sodium acetate (0.01M) and 15% methanol-acetonitrile (25 + 75) with a flow rate of 1 mL/min. Sensitivity was 20 ppb or less with a recovery of 61-80% in the range studied. Other beta-lactam antibiotics tested did not interfere with detection of cephapirin. Analysis of 30 samples of commercial homogenized milk obtained for a survey of antibiotics in consumer milk in Canada revealed no detectable cephapirin residues.  相似文献   

6.
A capillary gas chromatographic method is described for determining residues of beta-lactam antibiotic residues in milk, with specificity for benzylpenicillin (penicillin G), phenoxymethylpenicillin, methicillin, oxacillin, cloxacillin, dicloxacillin, and nafcillin. Residues are extracted from milk with acetonitrile. Samples are cleaned up by partitioning between aqueous and organic phases at different pH values. The penicillin residues are methylated with diazomethane to render them amenable to determination by gas chromatography on a methyl silicone fused silica column. Samples are introduced by split/splitless injection using a programmed temperature vaporization injector and are detected by nitrogen-selective thermionic detection. Internal standardization is used for quantitation. The limits of detection for all penicillins are well below 1 microgram/kg. Recoveries of spiked samples at 3 and 10 micrograms/kg are in the range of 42-85% (coefficients of variation 2-5%) and 41-92% (coefficients of variation 3-7%), respectively.  相似文献   

7.
A competitive-indirect enzyme-linked immunosorbent assay (CI-ELISA) was developed to quantify chlorimuron-ethyl in soil. The linear working range of the assay was from 1 to 1000 ng mL(-)(1). The assay had an I(50) value of 54 ng mL(-)(1), with a limit of detection of 2 ng mL(-)(1) and a limit of quantification of 27 ng mL(-)(1). Three soils were extracted using a carbonate buffer (pH 9.0) and the extracts spiked with chlorimuron-ethyl. Because of the effects of coextractants (matrix effects) from soil on the accuracy and precision of the ELISA, immunoaffinity chromatography (IAC) was used to purify chlorimuron-ethyl from soil extracts prior to analysis. The immunoaffinity columns, which had a total binding capacity of 1350 ng of chlorimuron-ethyl mL(-)(1) of immunosorbent, were prepared by binding anti-chlorimuron-ethyl antibodies to protein G Sepharose 4B. Although the matrix effects were largely removed using the affinity column, they could be completely removed by first passing the extract through a column containing epoxy-coupled 1,6-diaminohexane (EAH) Sepharose 4B to remove organic acids prior to IAC. Assay sensitivity was increased 100-fold using IAC to purify and simultaneously concentrate chlorimuron-ethyl from soil extracts. The purification strategy (EAH followed by IAC chromatography) removed matrix effects from all three soils and allowed for the accurate quantitation of chlorimuron-ethyl in soil extracts.  相似文献   

8.
A fast cylinder plate microbiological method was developed for the quantitative determination of penicillin G, ampicillin, and cloxacillin in milk. Agar plates seeded with stable spores of Bacillus stearothermophilus var. calidolactis were used and incubated at 64 degrees C for 4 1/2 hr. Standard curves were obtained for the following ranges of concentration of antibiotics: 0.004-0.064 IU penicillin G/mL, 0.0025-0.04 microgram ampicillin/mL, and 0.03-0.48 microgram cloxacillin/mL. The method is suitable for detecting penicillin residues in milk and for quantitative milk-out studies of the above antibiotics used in treatment of bovine mastitis.  相似文献   

9.
A direct competitive enzyme-linked immunosorbent assay (ELISA) was developed to detect a broad range of (fluoro)quinolones in various matrices. In the optimized generic test, anti-sarafloxacin antibodies in combination with norfloxacin conjugate showed 50% binding inhibition at 0.21 ng mL(-)(1) for sarafloxacin in buffer. Screening for this class of antibiotics is accomplished using a simple, rapid extraction carried out with a 1:1 mixture of methanol and phosphate-buffered saline adjusted to pH 7.4. This common extraction was able to detect 15 (fluoro)quinolone residues such as sarafloxacin, norfloxacin, difloxacin, ciprofloxacin, pefloxacin, ofloxacin, cinoxacin, danofloxacin, enrofloxacin, marbofloxacin, lomefloxacin, enoxacin, flumequine, oxolinic acid, and nalidixic acid in pig kidney, poultry muscle, egg, fish, and shrimp. The assay's detection capabilities (CCbeta) for most of these compounds were <10 microg kg(-)(1) except for the sarafloxacin-, oxolinic acid-, flumequine-, and cinoxacin-spiked matrices, the estimated CCbeta values of which were <4, <25, <100, and <200 microg kg(-)(1), respectively.  相似文献   

10.
A simple and rapid high performance liquid chromatographic method was developed for the separation and identification of amoxicillin, ampicillin, cloxacillin, dicloxacillin, methicillin, oxacillin, nafcillin, penicillin G potassium, and penicillin V potassium. The antibiotics were separated at ambient temperature on a Chromegabond 10 microns C18 column with acetonitrile-methanol-0. 01M potassium dihydrogen phosphate buffer, pH 4.7 (19 + 11 + 70), at 1 mL/min. A variable wavelength detector set at 225 nm, 0.16 AUFS , and a recorder set at 0.25 cm/min were used for the detection. Individual antibiotics and their mixtures were dissolved in the mobile phase and injected into the chromatograph through a 20 microL injection loop. Baseline separation was observed for virtually all 9 antibiotics. The entire mixture was resolved in less than 30 min. The method was sensitive, reproducible, and applicable to the qualitative analysis of commercial dosage forms.  相似文献   

11.
A monoclonal antibody was generated toward the beta-adrenergic agonist ractopamine hydrochloride ?(1R,3R),(1R, 3S)-4-hydroxy-alpha-[[[3-(4-hydroxyphenyl)-1-methylpropyl]amino]methy l]benzenemethanol hydrochloride?. Ractopamine-glutarate-keyhole limpet hemocyanin (KLH) was used as the antigen for antibody generation in mice. Clone 5G10, secreted antibody with isotype IgG1kappa, was used for the development of an immunoassay. The selected antibody was specific for racemic ractopamine with an IC(50) of 2.69 +/- 0.36 ng/mL (n = 15). Antibody binding toward ractopamine was stereoselective with (1R,3R)-ractopamine having an IC(50) of 0.55 +/- 0.09 ng/mL (n = 3). IC(50) values for the (1S, 3R)-, (1S,3S)-, and (1R,3S)-ractopamine stereoisomers were 2.00 +/- 0.37, 140 +/- 23, and 291+/- 32 ng/mL (n = 3), respectively. Phenethanolamine beta-agonists showed low cross-reactivity. Studies using a series of ractopamine metabolites and ractopamine analogues demonstrated structural requirements for the antibody binding. A free phenolic group on the N-butylphenol moiety was required for high-affinity binding because methoxylated analogues and metabolites glucuronidated at this phenol generally had IC(50) values greater than 200 ng/mL. Ractopamine analogues methoxylated or glucuronidated at the ethanolamine phenol had IC(50) values of 0.7-2.6 ng/mL. Lack of a benzylic hydroxyl group was of less importance to antibody binding than was the correct stereochemical orientation (3R) of ractopamine's N-phenylalkyl group. In conclusion, a highly specific monoclonal antibody to ractopamine hydrochloride was developed that could be of potential utility in screening assays.  相似文献   

12.
A collaborative study was performed on a Bacillus stearothermophilus paper disk method designed to detect residual levels of 4 antibiotic drugs in whole market milk. This method is a modification of an earlier procedure developed for the International Dairy Federation. Whole milk samples spiked at low levels with ampicillin, cephapirin, cloxacillin, and penicillin G were sent frozen to 11 collaborating laboratories with instructions to assay them promptly according to the method provided. Five of the laboratories reported inconclusive results due to technical difficulties encountered with the method. The 6 remaining laboratories all detected levels of 0.005-0.008 microgram or unit/mL for penicillin G, ampicillin, and cephapirin and 0.05-0.08 microgram/mL for cloxacillin. The most commonly used official methods, the Sarcina lutea (Micrococcus luteus) cylinder plate method and the Bacillus subtilis paper disk method, can detect levels of 0.01 and 0.05 unit penicillin G/mL, respectively. The B. stearothermophilus method is rapid, simple to perform, and more sensitive than present official methods. The method has been adopted as official first action for the detection of penicillins in milk.  相似文献   

13.
Two surface plasmon resonance (SPR)-based biosensor assays for detection of beta-lactam antibiotics in milk are reported. The assays are based on the enzymatic activity of a carboxypeptidase converting a 3-peptide into a 2-peptide, a reaction that is inhibited in the presence of beta-lactams. Antibodies were used to measure either the amount of formed enzymatic product or the amount of remaining enzymatic substrate. Both assays detected different beta-lactams at or below European maximum residue limits (MRLs), and the detection limit for penicillin G was 1.2 microg/kg and 1.5 microg/kg for the 2- and 3-peptide assays, respectively. The precision (CV) was < 5%, both within and between assays at the penicillin G MRL (4 microg/kg). The biosensor results obtained upon analysis of incurred milk samples were compared with results obtained by liquid chromatography (HPLC), and the method agreements were, in general, good.  相似文献   

14.
A simple method was developed for the determination of free and/or total isoflavones daidzein, genistein, and their respective 4'-methoxy derivatives biochanin A and formononetin (biochanin B) at low levels in human urine. A solid-phase extraction on octadecyl silica (C(18)) columns was used for the isolation of the phytoestrogens from the matrix. An extraction on a ChemElut 1010 column connected on-line to a Florisil cartridge by a Teflon stopcock was used for effective eluate purification. A mixture of dichloromethane and ethyl acetate was used for elution of the isoflavones from the columns in tandem. The isoflavones were determined as trimethylsilyl (TMS) ethers using GC/MS-SIM after separation on an HP-5MS fused silica column. TMS ethers were obtained by using BSTFA containing 1% of TMCS. For the determination of free isoflavones 6-hydroxyflavone was used as internal standard, whereas robigenin was used in the case of total isoflavone determination. Recoveries for free isoflavones under study varied from 63.5 to 89.6% at the 25 ng mL(-)(1) level and from 63.5 to 89. 2% at the 5 ng mL(-)(1) level in urine. Analytical curves were linear between 5 and 25 ng mL(-)(1). Detection limits varied from 1 ng mL(-)(1) for formononetin to 2.3 ng mL(-)(1) for daidzein. Recoveries for total isoflavone determination after enzymatic hydrolysis with glucuronidase from Helix pomatia ranged from 56.5 to 77.1% at the 25 ng mL(-1) level.  相似文献   

15.
A recently developed confirmatory LC-MS method has been applied to the quantification of five major beta-lactam antibiotics in suspect raw bovine milk samples that gave a positive response with receptor-based (BetaStar) and rapid microbial inhibitory screen tests (Delvotest SP). In total, 18 presumptive positive raw milk samples were reanalyzed; 16 samples showed traces of antibiotic residues that could be identified and quantified by the LC-MS method, ranging from the limits of confirmation up to 38 microg/kg. Of the positive samples, only five (approximately 30%) were found to be violative of EU maximum residue limits. The most frequently detected antibiotic residues were cloxacillin and penicillin G, the former often in combination with amoxicillin or ampicillin. This study compares the results obtained by the three methods on identical samples and addresses how these relate to certain criteria such as sensitivity and selectivity. Furthermore, the limitations of the LC-MS method and the potential impact of the presence of frequently more than one residue in the same milk sample on the response of the rapid test methods are discussed.  相似文献   

16.
A competitive direct enzyme-linked immunosorbent assay (ELISA) and high-pressure liquid chromatographic (HPLC) methods were compared in terms of accuracy and precision for the detection and quantification of glyphosate-spiked Nanopure, tap, and river waters. The ELISA had a detection limit of 0.6 ng mL(-)(1) and a linear working range of 1-25 ng mL(-)(1), whereas the HPLC method had a detection limit of 50 ng mL(-)(1) and a linear working range of 100-10000 ng mL(-)(l). No statistically significant differences (95% confidence interval) were found between the ELISA and HPLC analysis of the three water matrixes. The coefficients of variation obtained with the ELISA in tap water were between 10 and 19%, whereas the coefficients of variation for the HPLC analysis were between 7 and 15%. The use of ELISA for the analysis of glyphosate in water is a cost-effective and reliable method capable of meeting water quality guidelines established for Europe and North America.  相似文献   

17.
beta-Casein was quantified in milk and cheese, using an optical immunosensor, based on surface plasmon resonance (SPR) measurement. The assay consists of a two-step sandwich strategy, with two anti-beta-casein antibodies directed against each extremity of the casein. This strategy permits only native beta-casein to be quantified and not its degradation products. The calibration curve was obtained with a reference milk powder of known beta-casein concentration. The analysis time per sample was less than 10 minutes. The antibody-coated surface could be used for more than 250 determinations. The detection limit was established at 85 ng x mL(-)(1) and the intra- and inter-assay variation coefficients were 2.6 and 6.2% respectively. The method was applied to raw milk to quantify intact beta-casein, with no pretreatment of the sample. A second application was realized with cheese, to follow the proteolysis of beta-casein during ripening.  相似文献   

18.
The volume of antibiotic solutions in cylinders used for diffusion assays is assumed to have no significant effect on estimation of potency. The size of zones of inhibition from cylinders containing 0.10, 0.20, and 0.30 mL of sample solution was compared with zones of inhibition from cylinders containing 0.20 mL of standard solutions. For zinc bacitracin, chlortetracycline.HCl, oxytetracycline, lincomycin.HCl, monensin Na, neomycin sulfate, K penicillin, streptomycin sulfate, and tylosin, the percent recovery (95-102) was optimum when both standard and sample cylinders contained the same volume (0.20 mL/cylinder). At 0.30 mL/cylinder for sample and 0.20 mL for standard solutions, there was a positive bias in potency of about 50%. At 0.10 mL/cylinder, there was a negative bias of approximately 25% except for neomycin, monensin, and bacitracin. For these antibiotics, the bias was about -50%. For hygromycin B, variation in volume of solution per cylinder has little effect on assay results. Experiments on commercial feeds and premixes gave essentially the same results as for the standard solutions experiments.  相似文献   

19.
Two methods for the determination of iron in olive oil by spectrophotometry and by adsorptive stripping square wave voltammetry (Ad-SSWV) have been developed. These two methods are based on the formation of a 5,5-dimethylcyclohexane-1,2,3-trione 1,2-dioxime 3-thiosemicarbazone (DCDT)-iron(II) complex in strongly acid media. In both, iron is extracted from the olive oil by using HCl. Spectrophotometric determination of iron with DCDT is based on the feature that the DCDT-Fe complex shows an absorbance maximum at 550 nm. A calibration graph has been constructed from 0 to 4000 ng mL(-)(1), and the detection limit was 115 ng mL(-)(1) (57 ng g(-)(1) in olive oil). On the other hand, the voltammetric determination of the metal is based on the appearance of a peak due to an adsorptive reductive process of the complex that it is observed when the Ad-SSWV technique is used. A calibration graph has been constructed from 0 to 30 ng mL(-)(1), and the detection limit was 0.55 ng mL(-)(1) (13.75 ng g(-)(1) in olive oil according to the proposed procedure).  相似文献   

20.
A simple specific and rapid confirmatory method for determining the two amphoteric penicillins, that is, amoxicillin and ampicillin, in bovine muscle, liver, kidney, and milk is presented. This method is based on the matrix solid-phase dispersion technique with hot water as extractant followed by liquid chromatography (LC)-tandem mass spectrometry. With this instrumentation, the selected reaction monitoring acquisition mode with two fragmentation reactions for each analyte was adopted. After acidification and filtration of the aqueous extracts, 25 microL of the tissue final extracts and 50 microL of the milk final extract were injected into the LC apparatus. Absolute recovery of the two analytes in any biological matrix at the 50 ppb level in tissues and the 4 ppb level in milk was 74-95% with relative standard deviations (RSDs) of no larger than 9%. When penicillin V was used as surrogate internal standard, relative recovery of the targeted compounds present in bovine tissues and milk at, respectively, 25 and 2 ppb levels ranged between 100 and 106% with RSDs of no larger than 11%. When fractionation of analytes by using a short chromatographic run was attempted, remarkable signal weakening for the two analytes was experienced. This effect was traced to polar endogenous coextractives eluted in the first part of the chromatographic run that interfered with the gas-phase ion formation of the two penicillins. Slowing the chromatographic run eliminated this unwelcome effect. Limits of quantification of the two analytes in bovine milk were estimated to be <1 ppb, whereas amoxicillin and ampicillin could be quantified in bovine tissues down to 3.1 and 0.8 ppb levels, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号