共查询到13条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
Sandra Seigner Kirsten Bogedale Roswitha Dorsch Yury Zablotski Karin Weber 《Journal of veterinary diagnostic investigation》2022,34(6):944
The Vet Fluidlab 1 (Anvajo), a new urine sediment analyzer for use in veterinary medicine, uses holographic microscopy to detect urine sediment particles in uncentrifuged urine. We compared the performance of the Fluidlab to manual microscopy and Idexx SediVue analysis for the detection of RBC, WBC, epithelial cells (EC), struvite crystals (STR), all crystals (CRY), and casts (CST) in urine samples from cats and dogs. The performance of the Fluidlab for the detection of bacteria was compared to bacterial culture. We included 624 urine samples from feline (238; 38%) and canine (386; 62%) patients; 227 samples had been submitted for bacterial culturing. The sensitivity of the Fluidlab compared to manual microscopy was 92.1% for RBC, 90.1% for WBC, 87.5% for EC, 67.6% for STR, 53.9% for CRY, and 12.5% for CST. Specificity was >97% for STR and CST, 90.0% for CRY, 78.4% for WBC, 59.4% for EC, and 55.1% for RBC. Sensitivities and specificities of the Fluidlab for analytes compared to manual microscopy were found to be similar to those obtained by the Fluidlab compared to SediVue analysis. Miscellaneous materials (e.g., lipid droplets, sperm, cell detritus) seemed to be the main reason for the high false-positive rate in RBC and EC classification by the Fluidlab. Detection of bacteria by the Fluidlab compared to bacterial culture had a sensitivity of 89.8% and a specificity of 72.3%. The performance of the Fluidlab is acceptable for the detection of WBC and bacteria; sensitivity for the detection of CRY and CST, and specificity for the detection of RBC and EC, require improvement. 相似文献
5.
牛膝多糖对脂多糖免疫应激仔猪血液生化指标和白细胞分类计数的影响 总被引:1,自引:1,他引:1
试验旨在探讨牛膝多糖(ABPS)对脂多糖(LPS)刺激的断奶仔猪血液生化指标和白细胞分类计数的影响。选用48头(28±3)d、体重(8.45±0.14)kg的杜洛克×长白×大白断奶仔猪,采用2×2因子设计,两个因子分别为不同日粮处理(0或500mg/kgABPS)和免疫应激(注射LPS或生理盐水)。试验期28d。在第14天和第21天,每日粮组的一半猪注射100μg/kgBW的LPS,另一半注射生理盐水作对照。注射后3h,采血测定血液生化指标,并进行白细胞分类计数。结果表明:LPS刺激提高了第14天和第21天血清中碱性磷酸酶、谷草转氨酶(GOT)的活性及谷草转氨酶与谷丙转氨酶的比值(P0.05),并降低了第21天血清总蛋白和白蛋白的含量(P0.05);ABPS提高了第14天血清总蛋白和球蛋白的含量(P0.05)。在第14天,LPS刺激降低了白细胞、淋巴细胞、单核细胞和中性粒细胞的含量及单核细胞比例(P0.001)。在第21天,LPS刺激降低了白细胞、淋巴细胞的含量及比例,而提高了中性粒细胞比例(P0.001)。ABPS提高了白细胞(14d:P0.10)和中性粒细胞(14d:P0.05;21d:P0.05)的含量及中性粒细胞比例(14d:P0.05;21d:P0.10),降低了淋巴细胞比例(14d:P0.05;21d:P0.10)。结果提示,LPS可引起仔猪血液生化指标和白细胞分类计数发生显著变化,ABPS在一定程度可缓解上述现象,表现出一定的改善免疫和缓解炎症的作用。 相似文献
6.
Factors affecting urine reagent strip blood results in dogs and nonhuman primates and interpretation of urinalysis in preclinical toxicology studies: a Multi‐Institution Contract Research Organization and BioPharmaceutical Company Perspective 下载免费PDF全文
Adam D. Aulbach Eric Schultze Niraj K. Tripathi Robert L. Hall Michael R. Logan Denny J. Meyer 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2015,44(2):229-233
7.
Tatiana C. Weisbrod Ramiro Isaza Carolyn Cray Laurie Adler Nicole I. Stacy 《The Veterinary quarterly》2021,41(1):30
Unique features of elephant hematology are known challenges in analytical methodology like two types of monocytes typical for members of the Order Afrotheria and platelet counts of the comparatively small elephant platelet. To investigate WBC differential and platelet data generated by an impedance-based hematology analyzer without availability of validated species-specific software for recognition of elephant WBCs and platelets, compared to manual blood film review. Blood samples preserved in ethylenediaminetetraacetic acid (EDTA) of 50 elephants (n = 35 Elephas maximus and n = 15 Loxodonta africana) were used. A Mann-Whitney test for independent samples was used to compare parameters between methods and agreement was tested using Bland-Altman bias plots. All hematological variables, including absolute numbers of heterophils, lymphocytes, monocytes, eosinophils, basophils, and platelets, were significantly different (p < 0.0001) between both methods of analysis, and there was no agreement using Bland-Altman bias plots. Manual review consistently produced higher heterophil and monocyte counts as well as platelet estimates, while the automated analyzer produced higher lymphocyte, eosinophil, and basophil counts. The hematology analyzer did not properly differentiate elephant lymphocytes and monocytes, and did not accurately count elephant platelets. These findings emphasize the importance of manual blood film review as part of elephant complete blood counts in both clinical and research settings and as a basis for the development of hematological reference intervals. 相似文献
8.
Musavenga T. Tivapasi Joanne Hodges Barbara A. Byrne Mary M. Christopher 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2009,38(3):337-342
Background: Urinary tract infections (UTIs) may be subclinical or difficult to detect in dilute urine as sediment abnormalities may not be observed. In our laboratory, bacterial culture is automatically performed (reflex culture) on samples with urine specific gravity (USG)≤1.013 to increase the likelihood of detecting infection. The value of routine culture of dilute urine, however, has not been fully assessed. Objective: The purpose of this retrospective study was to evaluate the frequency of positive bacterial cultures and analyze the diagnostic utility and cost‐effectiveness of culture compared with routine sediment examination for detecting UTI in dilute urine specimens from dogs. Methods: Urinalysis and concurrent aerobic bacterial culture results were obtained from the electronic medical record system at the University of California–Davis Veterinary Medical Teaching Hospital for samples with USG≤1.013 analyzed from July 1998 through January 2005. Urine collection method, presence of leukocytes and bacteria, bacterial culture results, and clinical diagnosis were recorded. Cost‐effectiveness of reflex culture, based on low USG as the sole criterion, was evaluated. Results: Of 1264 urine specimens, 106 (8.4%) had positive bacterial cultures. Using culture as the gold standard, sediment evaluation had a diagnostic sensitivity of 58.5% and specificity of 98.3% (diagnostic accuracy 94.9%). An additional cost of $60 per patient was incurred, leading to average annual costs of $11,668 for reflex bacterial cultures of all samples with low USG, regardless of collection method. Within our study population, 10 urine samples needed to be cultured for each true positive result. Conclusions: The sensitivity of urine sediment evaluation is low for UTI in dilute urine samples; however, reflex bacterial culture does not appear to be cost‐effective in dogs with USG≤1.013 in the absence of active urine sediment or high clinical suspicion for UTI. 相似文献
9.
10.
11.
Comparison of 4 point‐of‐care blood gas analyzers for arterial blood gas analysis in healthy dogs and dogs with cardiopulmonary disease 下载免费PDF全文
Elodie Roels DVM Kris Gommeren DVM DECVIM Frédéric Farnir Ir PhD François Delvaux MS Frédéric Billen DVM PhD DECVIM Cécile Clercx DVM PhD DECVIM 《Journal of Veterinary Emergency and Critical Care》2016,26(3):352-359
12.
Alenka Seliškar Petra Zrimšek Jerneja Sredenšek Aleksandra D Petrič 《Veterinary anaesthesia and analgesia》2013,40(1):21-27
Objective To use the American College of Veterinary Internal Medicine (ACVIM) validation criteria to evaluate the performance of high definition oscillometric (HDO) and Doppler blood pressure measurement techniques against invasive blood pressure measurements in anaesthetized dogs. Study design Prospective clinical study. Animals Twenty client‐owned dogs. Materials and Methods Invasive blood pressure was measured using a catheter inserted into a pedal artery and an electronic transducer. The sites of cuff placement for the HDO measurements were the mid antebrachium or the proximal tail and, for the Doppler technique, the distal tibia. Agreement between invasive and non‐invasive blood pressure measurements was estimated by the Bland–Altman method. Results Only 10% and 34% of Doppler measurements were within 10 and 20 mmHg of invasive blood pressure values, respectively. The Doppler device failed to meet the ACVIM validation criteria for blood pressure measurement devices. The best agreement between HDO and invasive blood pressure measurement technique was observed for mean arterial blood pressure (MAP); 67% and 95% of readings were within 10 and 20 mmHg of invasive blood pressure values respectively. In addition, 52% and 87% of diastolic arterial blood pressure (DAP) measurements were within 10 and 20 mmHg of invasive readings. High definition oscillometric readings did not meet ACVIM recommended limits for SAP. Conclusion and clinical relevance The Doppler technique overestimated and the HDO device showed limited agreement with invasive blood pressure measurement in anaesthetized dogs. High definition oscillometry met most of the ACVIM requirements for MAP and DAP while the Doppler technique did not. 相似文献
13.
Welles EG Whatley EM Hall AS Wright JC 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2006,35(1):31-36
BACKGROUND: Urine protein: urine creatinine (UP:UC) ratio determined from the quantitative measurement of protein and creatinine in a single urine sample is the best feasible assessment of clinically significant proteinuria in dogs and cats. A dipstick that measures urine protein, urine creatinine, and UP:UC ratio has been used in human medicine and could have application for veterinary practice. OBJECTIVE: The objective of this study was to compare the Multistix PRO dipstick (Bayer Corporation, Elkhart, IN, USA) to other biochemical methods for determination of urine protein and creatinine, and UP:UC ratio in canine and feline urine. METHODS: A complete urinalysis, including sulfosalicylic acid (SSA) precipitation, was performed on urine samples submitted to our laboratory between February and April 2003 from 100 dogs and 49 cats. Urine protein and creatinine concentrations were determined by the Multistix PRO dipstick using a Clinitek 50 analyzer (Bayer) and compared with the results of SSA precipitation and quantitative biochemical analysis. The UP:UC ratios from the dipstick results (calculated by the Clinitek 50 and also manually) were compared with those calculated from quantitative values. Pearson product-moment correlation analysis and diagnostic sensitivity and specificity (using quantitative results as the gold standard) were determined. RESULTS: For both canine and feline urine, protein and creatinine concentrations determined by the Multistix PRO correlated closely with quantitative concentrations for protein (dogs r = .78, P = .0001; cats r = .87, P = .0001) and creatinine (dogs r = .78, P = .0001; cats r = .76, P = .0001). The Multistix PRO was more sensitive and less specific than SSA precipitation for diagnosing clinically significant proteinuria. UP:UC ratios obtained by manual calculation of dipstick results correlated best with quantitative UP:UC ratios in dogs, and had higher specificity but lower sensitivity for the diagnosis of proteinuria. In cats, UP:UC ratios determined by the dipstick method did not correlate (r = -.24, P = .0974) with quantitative values. CONCLUSIONS: The Multistix PRO, with manual calculation of UP:UC, may be a good alternative for the diagnosis of clinically significant proteinuria in dogs, but not cats. Dipstick creatinine concentration should be considered as an estimate. 相似文献