首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Objectives – To review the nonradiologist use of ultrasound (US) in the setting of emergency and critical care, the development, clinical applications, and standardization of veterinary abdominal and thoracic focused assessment with sonography for trauma (FAST) techniques. Etiology – Since the 1990s, the 4‐point FAST US technique has been used for injury surveillance in people with blunt and penetrating trauma. FAST screens for free fluid in the abdominal, pleural, and pericardial cavities with high sensitivity and specificity. More recently, an extended FAST scan was developed for the rapid detection of pneumothorax. These techniques and newly created scans have been applied to other critically ill, nontraumatized, subsets of human patients. As a result, the terminology related to this field, eg, extended FAST, HHFAST, FFAST, FAFF, BOAST, SLOH, bedside US, ‘$ Approach,’ protocols, and objectives have become convoluted despite having similar goals. Diagnosis – The importance of US in the setting of emergency medicine is highlighted by the fact that this diagnostic modality has become an integral part of the core curriculum for nonradiologists including the American College of Surgeons, American College of Emergency Physicians, American Board of Emergency Medicine, Society of Academic Emergency Medicine, and all United States Accreditation Council for Graduate Medical Education Emergency Medicine residency programs. Therapy – Veterinary applications of FAST techniques include an abdominal FAST technique with an abdominal FAST applied fluid scoring system, and a thoracic FAST technique. In an attempt to avoid the creation of numerous acronyms, veterinarians would be well served by making the ‘T’ in ‘FAST’ stand for ‘Trauma,’‘Triage,’ and ‘Tracking.’ Prognosis – These veterinary FAST techniques provide an extension of the physical examination for the emergency and critical care veterinarian potentially expediting diagnosis, prompting life‐saving maneuvers, and guiding patient management. Further clinical research to determine sensitivity, specificity, and accuracy for specific conditions is warranted.  相似文献   

3.
4.
王欣国  田嘉瑞  刘照辉 《草业科学》2013,30(10):1540-1546
依据高尔夫球场景观分类,划分景观元素,以景观学三大理论体系为基础,结合高尔夫的特点,运用AHP层次分析法,首次构建高尔夫球场景观评价AHP递阶层次模型;同时构建植物景观目标层评价AHP模型,形成指标类型层、景观学系统层、景观评价指标层,科学选择评价指标,合理确定权重,定量与定性研究相结合,并首次将景观人文指标纳入评价体系。  相似文献   

5.
6.
7.
Periodontal disease has deleterious effects on an animal's health and potentially serious implications for its welfare. Consequently, veterinarians frequently perform routine periodontal treatment in small-animal practice. One would therefore assume that small-animal dentistry would constitute a core component of a veterinary curriculum. However, most practitioners received little or no formal training in dentistry during their veterinary degrees, and the amount of instruction students currently receive is variable, often with limited opportunities to practice. At the Royal Veterinary College, a prototype dental model was developed to address the lack of practical training; it was made using ceramic tiles, silicone sealant, and grout to emulate teeth, gingiva, and calculus, respectively. A study was conducted with third-year veterinary students to compare the outcomes of learning to perform a professional dental cleaning using a model (group A) or a video (group B). Performance was assessed using an objective structured clinical examination. Students in group A scored significantly better than those in group B (p<.001). All students also completed a questionnaire evaluating attitudes toward the use of a dental model in learning dentistry-related skills. All students identified a model as a potentially valuable learning tool to supplement existing teaching methods and facilitate the acquisition of small-animal dentistry skills. The dental model has the potential to equip students with useful, practical skills in a safe and risk-free environment.  相似文献   

8.
9.
There are limited techniques available to assess the health of sea turtles as physical examination has little correlation to clinical findings, and blood reference intervals are broad and provide limited prognostic significance. Advances in the portability of ultrasound machines allow echocardiography to be increasingly used in the health assessments of wild animals. This study performed blood analysis and echocardiograms on 11 green sea turtles upon admission to a rehabilitation clinic and six animals before release. Significant differences were seen between groups, with admission animals having significantly smaller diameters of the cavum arteriosum at systole and diastole, smaller E‐waves and an increased fractional shortening. Pre‐release animals displayed significant increases in the maximum blood velocities of both the pulmonary artery and the left aorta. Significant negative correlations were seen between fractional shortening and uric acid and between the velocity time integral of the pulmonary artery and urea. The pulmonary artery velocity time integral was also significantly correlated to the E wave. Furthermore, there was asynchrony between the cavum arteriosum and the cavum pulmonale and the detection of a parasitic granuloma in the ventricular outflow tract of one animal. Overall, the results suggest that cardiac function in stranded green sea turtles is significantly impaired and that echocardiography has applications in the health assessments of green sea turtles.  相似文献   

10.
11.
The production of miniature animals has been suggested for use in organ transplantation. At present, many of the studies about application of animal organs to human have been focused on pigs because of the number of advantages involved and due to their similarities with human. However, a physiological analysis of the organs to be transplanted has not yet been carried out. Therefore, this study analyzed whether or not there were physiological and morphological differences in the hearts of conventionally-reared pigs and micropigs. In this study, the morphological and physiological functions of the heart were examined using radiographic and echocardiographic equipment. In the lateral radiographic view, the heart of the micropig has a larger cardiac long axis : short axis ratio than does the conventional pig, but the difference in the vertebral heart score was not significant. In addition, there were no morphological differences on the X-ray fluoroscopic view. There were no differences in echocardiographic values, except for several values in the left ventricle traces. Overall, it is expected that the values measured in this study will contribute to understanding of the physiological characteristics of micropigs.  相似文献   

12.
Veiled chameleons (Chamaeleo calyptratus) and panther chameleons (Furcifer pardalis) are the most popular chameleons over the world, and consequently, two of the most frequent species presenting to veterinary practices. However, published studies on normal ultrasonographic anatomy for these lizards are currently lacking. The objectives of this prospective anatomic study were to develop an ultrasound protocol for evaluation of the coelomic cavity in these species and describe the normal ultrasonographic anatomy of the coelomic organs. Seventeen healthy veiled chameleons and 15 healthy panther chameleons were included. A linear 18 MHz transducer was used. Chameleons were sedated and restrained in right lateral recumbency by an assistant. Longitudinal and transverse images were acquired, and authors recorded qualitative and quantitative ultrasonographic characteristics of the coelomic structures. The kidneys, liver, caudal vena cava, hepatic veins, portal vein, gallbladder, wall of the stomach and intestine, gonads and, when distended, urinary bladder could be visualized during ultrasonography of the coelomic cavity in both species. The spleen, pancreas, and adrenal glands could not be identified. Findings from the current study supported the use of ultrasonography for veiled chameleons (Chamaeleo calyptratus) and panther chameleons (Furcifer pardalis) with suspected intracoelomic diseases and provided normal reference information for future studies of these chameleon species.  相似文献   

13.
This case report describes the radiographic, ultrasonographic and computed tomographic (CT) examination of an abdominal swelling in a Red Oscar (Astronotus ocellatus Cuvier, 1829). While radiography only demonstrated caudoventral compression of the swimbladder, ultrasonography found a huge tumor-like parenchyma in the caudal abdomen. CT studies detected a possible connection between the tumor and the kidneys. Necropsy and pathohistology were performed. A papillary-cystic adenoma of the kidney was diagnosed.  相似文献   

14.
15.
Objectives – To (1) determine a reference interval for cardiac troponin I (cTnI) using a point‐of‐care device in normal dogs and compare the results with those published by the manufacturer and (2) determine if cTnI differs among dogs with cardiogenic and noncardiogenic respiratory distress. Design – Prospective observational study. Setting – Emergency and referral veterinary hospital. Animals – Twenty‐six clinically normal dogs and 67 dogs in respiratory distress. Interventions – All dogs underwent whole blood sampling for cTnI concentrations. Measurements and Results – Normal dogs had a median cTnI concentration of 0.03 ng/mL (range 0–0.11 ng/mL). Thirty‐six dogs were diagnosed with noncardiogenic respiratory distress with a median cTnI concentration of 0.14 ng/mL (range 0.01–4.31 ng/mL). Thirty‐one dogs were diagnosed with cardiogenic respiratory distress with a median cTnI concentration of 1.74 ng/mL (range 0.05–17.1 ng/mL). A significant difference between cTnI concentrations in normal dogs and dogs with noncardiogenic respiratory distress was not detected. Significant differences in cTnI concentrations were found between normals versus cardiogenic and cardiogenic versus noncardiogenic respiratory distress groups. Significant differences in cTnI concentrations were identified in >10 when compared with the <5 and the 5–10 years of age groups. Receiver operating curve analysis identified cTnI concentrations >1.5 ng/mL as the optimal “cut‐off point” having a sensitivity of 78% and specificity of 51.5%. The area under the receiver operating curve was 0.72. Overall test accuracy was 65%. Conclusions – cTnI concentrations were significantly increased in dogs with cardiogenic respiratory distress versus dogs with noncardiogenic respiratory distress and normal dogs. A significant difference between normal dogs and dogs with noncardiogenic causes of respiratory distress was detected. Although highly sensitive when cTnI concentrations exceed 1.5 ng/mL, the test has low specificity. Assessment of cTnI by the methodology used cannot be recommended as the sole diagnostic modality for evaluating the cause of respiratory distress in dogs.  相似文献   

16.
17.
郑伟 《草业科学》2014,8(11):2155-2163
构建草业科学本科毕业实习科学评价体系,使之能够准确地评价毕业实习的教学质量,是衡量草业科学本科人才培养质量的一项重要工作。利用模糊数学综合评价法对草业科学本科毕业实习进行评定,建立了5个一级指标、42个二级指标的多级评价体系,通过成立毕业实习学术委员会、毕业实习文献信息委员会对评价尺度和各级评价指标权重进行确定。多级模糊数学综合评价使得毕业实习的系统评价成为可能,兼顾了定性与定量评价,克服了评价的主观随意性,使得评价体系更具有激励和导向的作用,为完善草业科学导师制本科毕业培养模式提供帮助。  相似文献   

18.
ObjectiveTo evaluate the accuracy of a new cardiac output monitor (FloTrac/Vigileo), originally designed for humans, in dogs. This pulse contour cardiac output monitoring system cannot be calibrated and measures cardiac output (
t) from a standard arterial catheter.Study designProspective experimental trial.AnimalsEight adult Beagle dogs weighing 13.1 (9.8–17.1) kg [median (range)].MethodsAnaesthesia in the dogs was maintained using isoflurane. A pulmonary artery catheter and a metatarsal arterial catheter (22 gauge) were placed. Cardiac output was measured simultaneously 331 times by thermodilution and FloTrac technique. A broad spectrum of
t measurements was achieved through alterations of isoflurane concentration, administration of propofol boluses and dobutamine infusions. Agreement between the methods was quantified with Bland Altman analysis and disagreement was assessed with linear mixed models.ResultsMedian (10th and 90th percentile) cardiac output as measured with thermodilution was 2.54 (1.47 and 5.15) L minute?1 and as measured with FloTrac 8.6 (3.9 and 17.3) L minute?1. FloTrac measurements were consistently higher with a mean bias of 7 L minute?1 and limits of agreement of ?3.15 to 17.17 L minute?1. Difference between the methods was most pronounced in high
t measurements. Linear mixed models showed an estimated difference between the two methods of 8.05 (standard error 1.18) L minute?1 and a significant interaction between mean arterial pressure and method. Standard deviation (4.45 higher) with the FloTrac method compared to thermodilution was increased.ConclusionCompared to thermodilution measurements, the FloTrac system was influenced to a higher degree by arterial blood pressure, resulting in consistent overestimation of cardiac output.Clinical RelevanceThe FloTrac monitor, whose algorithms were developed based on human data, cannot be used as an alternative for thermodilution in dogs.  相似文献   

19.
Many point-of-care (POC) analyzers are available for the measurement of electrolytes and acid-base status in animals. We assessed the precision of the i-STAT Alinity v, a recently introduced POC analyzer, and compared it to 2 commonly used and previously validated POC analyzers (i-STAT 1, Stat Profile pHOx Ultra). Precision was evaluated by performing multiple analyses of whole blood samples from healthy dogs, cats, and horses on multiple i-STAT Alinity v analyzers. For comparison between analyzers, whole blood samples from dogs and cats presented to the emergency room were run concurrently on all 3 POC instruments. Reported values were compared by species (dogs and cats only) using Pearson correlation, and all values from all species were analyzed together for the Bland–Altman analysis. Results suggested that the i-STAT Alinity v precision was very good, with median coefficients of variability <2.5% for all measured parameters (except the anion gap), with variable ranges of coefficients of variation. In addition, good-to-excellent correlation was observed between the i-STAT Alinity v and i-STAT 1, and between the i-STAT Alinity v and Stat Profile pHOx Ultra for all parameters in both cats and dogs, respectively. In this cohort, the i-STAT Alinity v had clinically acceptable bias compared to the currently marketed analyzers and can be used for monitoring measured analytes in cats and dogs, although serial measurements in a single animal should be performed on the same analyzer whenever possible.  相似文献   

20.
OBJECTIVE: To establish a focused assessment with sonography for trauma (FAST) protocol in dogs, determine whether FAST can be performed by veterinary clinicians without extensive ultrasonographic experience, and assess the frequency of free fluid (as determined via FAST) in the abdominal cavity of dogs following motor vehicle accidents (MVAs). DESIGN: Prospective study. ANIMALS: 100 client-owned dogs evaluated within 24 hours of an MVA. PROCEDURE: Dogs were placed in lateral recumbency for the FAST examination. To detect fluid in the abdomen, 2 ultrasonographic views (transverse and longitudinal) were obtained at each of 4 sites (just caudal to the xiphoid process, on the midline over the urinary bladder, and at the left and right flank regions). RESULTS: In the 100 dogs evaluated via FAST, free abdominal fluid was detected in 45 dogs. In 40 of those 45 dogs, abdominocentesis was performed; hemoperitoneum and uroperitoneum were diagnosed in 38 and 2 dogs, respectively. Compared with dogs that had no free abdominal fluid detected via FAST, dogs that had free abdominal fluid detected via FAST had significantly higher heart rates and serum lactate concentrations and significantly lower PCVs and total solid concentrations. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicate that FAST is a simple and rapid technique that can be performed on dogs in an emergency setting to detect intra-abdominal free fluid and can be performed by veterinary clinicians with minimal previous ultrasonographic experience.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号