首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Two enzyme-linked immunosorbent assays (ELISAs) were tested for their suitability for detecting sulfonamides in wastewater from various stages in wastewater treatment plants (WWTPs), the river into which the wastewater is discharged, and two swine-rearing facilities. The sulfamethoxazole ELISA cross-reacts with several compounds, achieving detection limits of <0.04 microg/L for sulfamethoxazole (SMX), sulfamethoxypyridine, sulfachloropyridine, and sulfamethoxine, whereas the sulfamethazine (SMZ) ELISA is more compound specific, with a detection limit of <0.03 microg/L. Samples from various stages of wastewater purifications gave 0.6-3.1 microg/L by SMX-ELISA, whereas river samples were approximately 10-fold lower, ranging from below detection to 0.09 microg/L. Swine wastewater samples analyzed by the SMX-ELISA were either at or near detectable limits from one facility, whereas the other facility had concentrations of approximately 0.5 microg/L, although LC-MS/MS did not confirm the presence of SMX. Sulfamethazine ELISA detected no SMZ in either WWTP or river samples. In contrast, wastewater samples from swine facilities analyzed by SMZ-ELISA were found to contain approximately 30 microg/L [piglet (50-100 lb) wastewater] and approximately 7 microg/L (market-weight hog wastewater). Sulfamethazine ELISA analyses of wastewater from another swine facility found concentrations to be near or below detection limits. A solid phase extraction method was used to isolate and concentrate sulfonamides from water samples prior to LC-MS/MS multiresidue confirmatory analysis. The recoveries at 1 microg/L fortification ranged from 42 +/- 4% for SMZ to 88 +/- 4% for SMX ( n = 6). The ELISA results in the WWTPs were confirmed by LC-MS/MS, as sulfonamide multiresidue confirmatory analysis identified SMX, sulfapyridine, and sulfasalazine to be present in the wastewater. Sulfamethazine presence at one swine-rearing facility was also confirmed by LC-MS/MS, demonstrating the usefulness of the ELISA technique as a rapid and high-throughput screening method.  相似文献   

2.
Austral bracken Pteridium esculentum contains three unstable norsesquiterpene glycosides: ptaquiloside, ptesculentoside, and caudatoside, in variable proportions. The concentration of each of the glycosides was determined in this study as their respective degradation products, pterosin B, pterosin G and pterosin A, by HPLC-UV analysis. Samples of P. esculentum collected from six sites in eastern Australia contained up to 17 mg of total glycoside/g DW, with both ptaquiloside and ptesculentoside present as major components accompanied by smaller amounts of caudatoside. Ratios of ptaquiloside to ptesculentoside varied from 1:3 to 4:3, but in all Australian samples ptesculentoside was a significant component. This profile differed substantially from that of P. esculentum from New Zealand, which contained only small amounts of both ptesculentoside and caudatoside, with ptaquiloside as the dominant component. A similar profile with ptaquiloside as the dominant glycoside was obtained for Pteridium aquilinum subsp. wightianum (previously P. revolutum ) from northern Queensland and also P. aquilinum from European sources. Ptesculentoside has chemical reactivity similar to that of ptaquiloside and presumably biological activity similar to that of this potent carcinogen. The presence of this additional reactive glycoside in Australian P. esculentum implies greater toxicity for consuming animals than previously estimated from ptaquiloside content alone.  相似文献   

3.
Austral bracken, Pteridium esculentum , occurs widely in Australian grazing lands and contains both the known carcinogen ptaquiloside and its hydroxy analogue, ptesculentoside, with untested carcinogenic potential. Calves were fed a diet containing 19% P. esculentum that delivered 1.8 mg of ptaquiloside and 4.0 mg of ptesculentoside per kilogram of body weight (bw) per day to explore the carcass residue potential of these compounds. Concentrations of ptaquiloside and ptesculentoside in the liver, kidney, skeletal muscle, heart, and blood of these calves were determined as their respective elimination products, pterosin B and pterosin G, by HPLC-UV analysis. Plasma concentrations of up to 0.97 μg/mL ptaquiloside and 1.30 μg/mL ptesculentoside were found, but were shown to deplete to <10% of these values within 24 h of bracken consumption. Both glycosides were also detected in all tissues assayed, with ptesculentoside appearing to be more residual than ptaquiloside. Up to 0.42 and 0.32 μg/g ptesculentoside was present in skeletal muscle and liver, respectively, 15 days after bracken consumption ended. This detection of residual glycosides in tissues of cattle feeding on Austral bracken raises health concerns for consumers and warrants further investigation.  相似文献   

4.
A rapid LC-MS method, which compares different mass analyzers-single quadrupole, ion trap, and triple quadrupole-was developed for the quantitative determination of isopropyl thioxanthone (ITX) in fruit juices. ITX, a photoinitiator in UV-cured inks that can reach foods from the cartons for beverages in which they are used, was extracted from fruit juice samples with acetone/hexane (50:50) using pressurized liquid extraction. This method gave detection limits of 3, 3, and 0.01 microg/L and quantification limits of 10, 10, and 0.05 microg/L using single quadrupole, ion trap, and triple quadrupole, respectively. Five replicate fortifications of different fruit juices at the quantification limit gave recoveries oscillating between 68 and 72% with CV varying between 14 and 18%. This is the first report of a positive mass spectrometric identification and quantification of ITX in fruit juice samples packed in TetraPack. The sensitivity and specificity of the LC-MS/MS analysis using the triple quadrupole enables it to be the method of choice for risk assessment and monitoring. The method was applied to apricot, orange, peach, apple, grape and pineapple, and cherry and strawberry juices and to fruit nectars from Spain and Italy, and the ITX was detected in the range of 0.05-0.78 microg/L.  相似文献   

5.
In recent years there has been an increase in the use of tylosin in apiculture as bacterial brood diseases become resistant to oxytetracycline. Confirmatory mass spectrometry based methods have been developed but up until now there has been no complementary screening method available capable of sub 10 microg kg(-1) detection limits. In this paper the development and validation of a screening method using optical biosensor technology is presented. The honey was first dissolved in a phosphate buffer and following solid-phase extraction (SPE) cleanup was analyzed using a Biacore Q instrument. Using the criteria specified in European Commission Decision 2002/657/EC for qualitative screening methods, the detection capability (CCbeta) of the method was determined to be 2.5 microg kg(-)(1). Honey samples containing trace residue levels of tylosin were analyzed by both the biosensor screening method and a LC-MS/MS confirmatory procedure; the results were in good agreement.  相似文献   

6.
A rapid LC-MS/MS method, using a triple-quadrupole/linear ion trap mass spectrometer, was developed for the quantitative determination of oleandrin in serum, urine, and tissue samples. Oleandrin, the major cardiac glycoside of oleander (Nerium oleander L.), was extracted from serum and urine samples with methylene chloride and from tissues with acetonitrile. The tissue extracts were cleaned up using Florisil solid-phase extraction columns. Six replicate fortifications of serum and urine at 0.001 microg/g (1 ppb) oleandrin gave average recoveries of 97% with 5% CV (relative standard deviation) and 107% with 7% CV, respectively. Six replicate fortifications of liver at 0.005 microg/g (5 ppb) oleandrin gave average recoveries of 98% with 6% CV. This is the first report of a positive mass spectrometric identification and quantitation of oleandrin in tissue samples from oleander intoxication cases. The sensitivity and specificity of the LC-MS/MS analysis enables it to be the method of choice for toxicological investigations of oleander poisoning.  相似文献   

7.
The area cultivated with Artemisia annua for the extraction of the antimalarial compound artemisinin is increasing, but the environmental impact of this cultivation has not yet been studied. A sensitive and robust method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the determination of artemisinin in soil. Dihydroartemisinin and artemether were included in the method, and performance on analytical columns of both traditional C(18) phenyl-hexyl and porous shell particles-based Kinetex types was characterized. The versatility of the method was demonstrated on surface water and groundwater samples and plant extracts. The limit of detection was 55, 30 (25 ng/g soil), and 4 ng/mL for dihydroartemisinin, artemisinin, and artemether, respectively. Method performance was demonstrated using naturally contaminated soil samples from A. annua fields in Kenya. The highest observed concentrations were above EC(10) for lettuce growth. Monitoring of artemisinin in soil with A. annua crop production seems necessary to further understand the impact in the environment.  相似文献   

8.
An LC-MS/MS method was developed for the semiquantitative determination of strophanthidin glycosides in ingesta from animals. Strophanthidin glycosides were simultaneously extracted and hydrolyzed to the strophanthidin aglycone using aqueous methanolic hydrochloric acid and the extracts cleaned up using solid-phase extraction. Extracts were analyzed using reverse-phase HPLC coupled with positive ion electrospray mass spectrometry. Characteristic product ion spectra were produced by fragmentation of the [M + H](+) precursor ion for each analyte. Quantitation was performed using the internal standard method with digitoxigenin serving as the internal standard. The method detection limit was calculated to be 0.075 microg/g, and the limit of quantitation was calculated to be 0.24 microg/g for strophanthidin in control rumen samples. This method was used in diagnostic investigations to confirm fatal strophanthidin glycoside poisonings in horses.  相似文献   

9.
A total of 205 cornflake samples collected in Belgian retail stores during 2003-2004 were surveyed for the natural occurrence of fumonisin B1 (FB1), B2 (FB2), and B3 (FB3). These cornflake samples, originating from conventional as well as from organic production, were analyzed using an intralaboratory-validated LC-MS/MS method. Additionally, 90 cornflake samples were subjected to rapid screening using a flow-through enzyme immunoassay method to demonstrate the practicability of a screening test coupled to a validated confirmatory LC-MS/MS method for the management of food safety risks. FB(1) concentrations ranged from not detected (nd) [LOD (FB1) = 20 microg/kg] to 464 microg/kg with mean and median concentrations of respectively 104 +/- 113 and 54 microg/kg. For FB2 and FB3, the concentration ranges varied respectively from nd [LOD (FB2) = 7.5 microg/kg] to 43 microg/kg and from nd [LOD (FB3) = 12.5 microg/kg] to 90 microg/kg. Mean concentrations for FB2 and FB3 were respectively 12 +/- 8 and 21 +/- 15 microg/kg, while the median concentration was 11 microg/kg for FB2 and 19 microg/kg for FB3. From the statistical tests (chi2 and ANOVA model III), it could be concluded that the agricultural practice did not have any significant effect on the fumonisin concentrations but that the variation between different batches was significant (p < 0.0001).  相似文献   

10.
A method based on a gel permeation chromatography (GPC) extraction procedure combined with an additional cleanup by solid-phase extraction (SPE) on silica gel and liquid chromatography-mass spectrometry (LC-MS) detection has been validated for the analysis of seven glycidyl esters (GEs) including glycidyl laurate, myristate, palmitate, stearate, oleate, linoleate, and linolenate in various edible oils. This method was conjointly developed and validated by two different laboratories, using two different detection systems, a LC time of flight MS (LC-ToF-MS) and a LC triple-quadrupole MS (LC-MS/MS). The extraction procedure allowed targeting low contamination levels due to a highly efficient matrix removal from the 400 mg oil sample loaded on the GPC column and is suitable for routine analysis as 24 samples can be extracted in an automated and reproducible way every 12 h. GPC extraction combined with SPE cleanup and LC-MS/MS detection leads to a limit of quantification in oil samples between 50 and 100 μg/kg depending on the type of glycidyl ester. Recoveries ranged from 68 to 111% (average = 93%). Quantification was performed by automated standard addition on extracts to compensate matrix effects artifacts. To control recoveries of each sample four isotopically labeled GEs ((13)C(3) or (13)C(4)) were included in the method.  相似文献   

11.
Immunoaffinity supports (IAS) were prepared using broad specific polyclonal anti-sulfonylurea (SU) antibodies immobilized in sol-gel glass. Two different kinds of supports were applied, crushed sol-gel monoliths and sol-gel-coated highly porous silica particles. Both were used for the quantitative enrichment of SUs in natural water and food samples followed by high-performance liquid chromatography-ultraviolet/diode array detection (HPLC-UV/DAD) and tandem mass spectrometry (LC-MS/MS), respectively. Loading, washing, and elution conditions of IAS were optimized. The capacity of supports was determined for 30 SUs and compared with the cross-reactivity pattern of the direct competitive enzyme-linked immunosorbent assay. The capacities correlated well with the affinity to individual SU compounds. Even analytes to which the polyclonal antibodies showed only a lower cross-reactivity could be enriched to a certain degree, if a sufficient capacity of IAS was provided. The IAS could be reused at least 10 times without a loss of effectiveness. Recovery of 16 selected SUs extracted from spiked water and food samples was dependent on the affinity of both immobilized antibodies to single compounds and matrix interferences. In water, 13 SUs showed recoveries higher than 80% when immunoaffinity extraction was used in combination with LC-UV/DAD. On the basis of the enrichment of 200 mL of aqueous sample, corresponding limit of detection (LOD) values ranged between 20 and 100 ng/L. The recoveries of 10 SUs, which were extracted from 10 g of potato spiked at a 10 microg/kg level, were higher than 75%. For grain samples, recoveries were at the same order for at least five SU herbicides. The LOD of LC-MS/MS measurements was about 1 order of magnitude higher, i.e., gave LODs between 1.1 and 6.9 microg/kg of food sample, depending on the compound and extraction procedure. These LODs provide evidence that the main advantage of the prepared IAS is their high selectivity for group specific recognition of SUs as compared to other nonspecific solid phase extraction materials.  相似文献   

12.
A new methodology is described for rapidly determining the herbicide oryzalin in water, citrus fruits, and stone fruits by liquid chromatography with negative ion electrospray ionization tandem mass spectrometry (LC/MS/MS). Oryzalin is extracted from water using a polymeric sorbent solid phase extraction (SPE) column and from fruit using methanol. The water samples require no further purification, but an aliquot of the fruit sample extracts is diluted with water and purified using a polymeric 96 well SPE plate. Purified extracts are concentrated prior to determination by LC/MS/MS at m/z 345 (Q1) and m/z 281 (Q3) using an external standard for calibration. The validated limits of quantitation were 0.05 microg/L in water (drinking water, surface water, and groundwater) and 0.01 microg/g in citrus fruits (oranges and lemons) and stone fruits (peaches and cherries). Recoveries averaged 102% for water samples and 85-89% for the various types of fruit samples. For all fortification levels combined, the relative standard deviations ranged from 4 to 6% for water and from 2 to 4% for fruit.  相似文献   

13.
A robust multi-residue procedure is needed for the analysis of the pro-herbicide isoxaflutole and its degradates in soil and plant materials at environmentally relevant (<1 microg kg-1) levels. An analytical method using turbo-spray and heat-nebulizer high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed for the analysis of isoxaflutole (IXF) and its two metabolites, diketonitrile (DKN) and the benzoic acid metabolite (BA), at sub-microgram per kilogram levels in soil and plant samples. The average recoveries of the three compounds in spiked soil and plant samples ranged from 84 to 110% and 94 to 105%, respectively. The limits of quantification were validated at 0.06 microg kg-1 for soil and 0.3 microg kg-1 for plant samples. The limits of detection (LOD) for soil analysis were 0.01, 0.002, and 0.01 microg kg-1 for IXF, DKN, and BA, respectively. Corresponding LOD for the plant analysis method were 0.05, 0.01, and 0.05 microg kg-1. The developed method was validated using forage grass and soil samples collected from a field lysimeter study in which IXF was applied to each of four forage treatments. Forage plants and soils were sampled for analyses 25 days after IXF application to the soil. In soils, IXF was not detected in any treatment, and DKN was the predominant metabolite found. In forage plants, the concentrations of DKN and BA were 10-100-fold higher than that in soil samples, but IXF was not detected in any forage plants. The much higher proportion of BA to DKN in plant tissues (23-53%), as compared to soils (0-5%), suggested that these forages were capable of detoxifying DKN. The developed methods provided LODs at sub-microgram per kilogram levels to determine the fate of IXF and its metabolites in soils and forage plants, and they also represent considerable improvements in extraction recovery rates and detection sensitivity as compared to previous analytical methods for these compounds.  相似文献   

14.
N-nitrosodimethylamine (NDMA) is one of the most important disinfection by-products (DBPs) due to its carcinogenicity even at low concentrations which correspond to the levels occurring in drinking water and wastewater effluents. Therefore, NDMA is a candidate DBP that is expected to be regulated in the near future. However, the measurement of NDMA in the low nanogram per liter range is challenging because of the limitations of analytical techniques including both the sample preparation and the LC-MS/MS. Moreover, the accuracy of most of the current methods is only tested for drinking water and no information is present for other matrices. In this study, a combination of solid-phase extraction (SPE) and LC-MS/MS method that does not require high-resolution MS or advanced techniques for sample pretreatment is developed. Moreover, important factors that affect the optimization of the SPE method are provided to enable readers to optimize their own SPE procedures if necessary. The proposed method was validated for surface water, groundwater, and wastewater samples and the method quantification limit was 2?ng/L. In addition, the proposed method was used to determine the concentration of NDMA precursors measured as NDMA formation potential (NDMAFP) throughout a drinking water treatment plant at two different sampling periods. NDMAFP decreased by approximately 40?% in both samples. The concentrations ranged between 4 and 11.5?ng/L and the presence of these low concentrations underlines the need for an easy to use, yet sensitive method for the determination of NDMA in environmental matrices.  相似文献   

15.
Analysis of acrylamide,a carcinogen formed in heated foodstuffs   总被引:55,自引:0,他引:55  
Reaction products (adducts) of acrylamide with N termini of hemoglobin (Hb) are regularly observed in persons without known exposure. The average Hb adduct level measured in Swedish adults is preliminarily estimated to correspond to a daily intake approaching 100 microg of acrylamide. Because this uptake rate could be associated with a considerable cancer risk, it was considered important to identify its origin. It was hypothesized that acrylamide was formed at elevated temperatures in cooking, which was indicated in earlier studies of rats fed fried animal feed. This paper reports the analysis of acrylamide formed during heating of different human foodstuffs. Acrylamide levels in foodstuffs were analyzed by an improved gas chromatographic-mass spectrometric (GC-MS) method after bromination of acrylamide and by a new method for measurement of the underivatized acrylamide by liquid chromatography-mass spectrometry (LC-MS), using the MS/MS mode. For both methods the reproducibility, given as coefficient of variation, was approximately 5%, and the recovery close to 100%. For the GC-MS method the achieved detection level of acrylamide was 5 microg/kg and for the LC-MS/MS method, 10 microg/kg. The analytic values obtained with the LC-MS/MS method were 0.99 (0.95-1.04; 95% confidence interval) of the GC-MS values. The LC-MS/MS method is simpler and preferable for most routine analyses. Taken together, the various analytic data should be considered as proof of the identity of acrylamide. Studies with laboratory-heated foods revealed a temperature dependence of acrylamide formation. Moderate levels of acrylamide (5-50 microg/kg) were measured in heated protein-rich foods and higher contents (150-4000 microg/kg) in carbohydrate-rich foods, such as potato, beetroot, and also certain heated commercial potato products and crispbread. Acrylamide could not be detected in unheated control or boiled foods (<5 microg/kg). Consumption habits indicate that the acrylamide levels in the studied heated foods could lead to a daily intake of a few tens of micrograms.  相似文献   

16.
Rugged LC-MS/MS survey analysis for acrylamide in foods   总被引:8,自引:0,他引:8  
The described liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection of acrylamide in food entails aqueous room temperature extraction, SPE cleanup, and analysis by LC-MS/MS. The method is applicable to a wide variety of foods. [(13)C(3)]acrylamide is the internal standard. The limit of quantitation is 10 ppb (microg/kg). Data were obtained in duplicate from >450 products representing >35 different food types. The variability in analyte levels in certain food types suggests that it may be possible to reduce acrylamide levels in those foods.  相似文献   

17.
A liquid chromatography-mass spectrometric (LC-MS/MS) method has been developed for determination of ethynylestradiol residues in cattle hair. Hair samples were pulverized with a cryogenic mill followed by a simple extraction with acetonitrile. A dansyl derivatization procedure to improve ethynylestradiol detection was used before the LC-MS/MS analysis in multiple reaction monitoring (MRM) mode using alpha-estradiol as an internal standard. The method was validated following the latest EU guidelines using blank hair samples spiked at 2 ng g(-1). The detection capability (CCbeta) was less than 2 ng g(-1), and the decision limit (CCalpha) was 1 ng g(-1). Incurred samples obtained 56 days after cow treatment with ethynylestradiol were analyzed, and the presence of ethynylestradiol in the hair was confirmed in all cases.  相似文献   

18.
A procedure combining diphasic dialysis extraction with in situ acylation and gas chromatography/mass spectrometry (GC/MS) determination was developed for detection and quantification of the mycotoxin patulin in apple juice. Apple juice samples spiked with 4-N,N-dimethylaminopyridine were dialyzed using methane chloride and acetic anhydride inside dialysis tubing. Patulin was derivatized into its acetate and collected in the tubing after diphasic dialysis and was directly determined using GC/MS with the selective ion monitoring mode without further concentration and cleanup steps. Quantification was carried out by a calibration curve with an internal standard of correlation. The appropriate parameters of both dialysis and derivatization were examined. The linear range of the calibration curve was found to be 10-250 microg/L for patulin, and the limit of quantification was 10 microg/L. Levels of patulin ranging from 0 to 107.2 microg/L with 77-109% recovery were found in 10 apple samples. The technique combining diphasic dialysis extraction and acylation was demonstrated and showed potential for other applications.  相似文献   

19.
An analytical method has been developed for the quantification of two herbicides (ethidimuron and methabenzthiazuron) and their two main soil derivatives. This method involves fluidized-bed extraction (FBE) prior to cleanup and analysis by reverse-phase liquid chromatography with UV detection at 282 nm. FBE conditions were established to provide efficient extraction without degradation of the four analytes. (14)C-labeled compounds were used for the optimization of extraction and purification steps and for the determination of related efficiencies. Extraction was optimal using a fexIKA extractor operating at 110 degrees C for three cycles (total time = 95 min) with 75 g of soil and 150 mL of a 60:40 v/v acetone/water mixture. Extracts were further purified on a 500 mg silica SPE cartridge. Separation was performed on a C18 Purosphere column (250 mm x 4 mm i.d.), at 0.8 mL min(-1) and 30 degrees C with an elution gradient made up of phosphoric acid aqueous solution (pH 2.2) and acetonitrile. Calibration curves were found to be linear in the 0.5-50 mg L(-1) concentration range. Besides freshly spiked soil samples, method validation included the analysis of samples with aged residues. Recovery values, determined from spiked samples, were close to 100%. Limits of detection ranged between 2 and 3 microg kg(-1) of dry soil and limits of quantification between 8 and 10 microg kg(-1) of dry soil. An attempt to improve these performances by using fluorescence detection following postcolumn derivatization by orthophthalaldehyde-mercaptoethanol reagent was unsuccessful.  相似文献   

20.
A rapid LC-MS/MS method was developed for the quantitative determination of grayanotoxins I, II, and III in rumen contents, feces, and urine. The grayanotoxins were extracted from solid samples with methanol. The methanol extract was diluted with water and cleaned up using a reversed phase solid phase extraction column. HPLC separation was performed by reversed phase HPLC using a gradient of water and methanol containing 1% acetic acid. Determination was by positive ion electrospray ionization and ion trap tandem mass spectrometry. Grayanotoxin I quantitation was based on fragmentation of the sodium adduct ion at m/z 435 to a product ion at m/z 375. Grayanotoxins II and III were quantitated on the basis of fragmentation of the ion at m/z 335 to the product ion at m/z 299. The method detection limits were 0.2 microg/g in rumen contents and feces and 0.05 microg/g in urine. Fortifications at the detection limits and 10 times the detection limits of bovine rumen contents, caprine feces, and ovine urine were recovered in the range 80-114%. The diagnostic utility of the method was tested by analyzing samples submitted to the veterinary toxicology laboratory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号