共查询到11条相似文献,搜索用时 46 毫秒
1.
随着电力能源的使用不断加大,隔离开关成为变电站中最常用的安全设备之一,但是隔离开关因为制造、环境等方面的影响,使其故障问题频发,严重影响着电力系统正常运行。本文针对隔离开关常见问题进行分析,并且提出相应的改造技术,望提高供电安全性和稳定性。 相似文献
2.
3.
猪呼吸道冠状病毒(PRCV)研究概况 总被引:1,自引:0,他引:1
猪呼吸道冠状病毒病(PorcineDespiratoryCorouavirus,PRC)是由于感染猪呼吸道冠状病毒(PRCV)引起的一种呼吸道疾病。PRCV由猪传染性胃肠炎病毒(TGEV)演化而来的。本文综述了猪呼吸道冠状病毒(PRCV)的特性、基因组结构及主要病毒蛋白、诊断方法、免疫学上的作用等方面在国内外的研究情况。 相似文献
4.
5.
桑蚕卵电晕人工孵化技术研究:V.电晕处理蚕种的农村饲育 总被引:2,自引:0,他引:2
通过1994~1996年电晕处理蚕种的农村饲养,得到以下几点认识,在保证卵面消毒和排除孵化不齐因素情况下,电晕蚕种与浸酸蚕种的产量质量无显著差异,专供农用的大板电晕仪存在放电不匀,孵经不齐和孵化率欠高的问题,有待改进,电晕处理蚕种还须进行卵消毒。 相似文献
6.
7.
8.
9.
10.
Gregory M. Anderson DVM Alan R. Cross DVM Diplomate ACVS Daniel D. Lewis DVM Diplomate ACVS Otto I. Lanz DVM Diplomate ACVS 《Veterinary surgery : VS》2002,31(1):3-9
OBJECTIVE: To compare the accuracy of reduction and biomechanical characteristics of acetabular osteotomies repaired with luted and nonluted reconstruction plates. STUDY DESIGN: In vitro study. ANIMALS: Pelves removed from 12 adult greyhounds. METHODS: Acetabular osteotomies were created and repaired with a 6-hole, 2.7-mm reconstruction plates in 24 cadaver hemipelves. Ten hemipelves each were assigned to group I and group II. An impression cast of each acetabulum in group I was made before luting (preluting cast). Group I plates were then elevated, luted, and replaced. A second cast of each acetabulum in group I was then made (postluting cast). Step, gap, and total areas of articular osteotomy incongruence were determined from the casts. Group I (luted plate repairs) and group II (nonluted plate repairs) hemipelves were loaded ventral-to-dorsal using a materials-testing machine. Stiffness, yield load, and maximal load sustained were determined. RESULTS: Mean gap and total area of articular osteotomy incongruence for group I preluted plate repairs (7.1 mm(2) and 8.6 mm(2), respectively) were significantly greater than for group I postluted plate repairs (4.1 mm(2) and 5.1 mm(2), respectively). Mean stiffness and maximal load for group I (681 N/mm and 2,555 N, respectively) were significantly greater than for group II (360 N/mm and 1,730 N, respectively). Mean step area and mean load at yield values were not significantly different between groups. CONCLUSIONS: Luted plate repairs of osteotomized acetabulae result in improved reduction and are stiffer and stronger than nonluted plate repairs. CLINICAL SIGNIFICANCE: Plate luting may improve the accuracy of reduction of acetabular fractures where anatomic reduction is required. Plate luting may also increase the stiffness and strength of fracture repairs and arthrodeses. 相似文献