OBJECTIVE: To evaluate and compare the mechanical properties of 4.5 narrow and 3.5 broad plating systems using their respective cortical and cancellous screws in unstable, central, and eccentric gap fracture models. STUDY DESIGN: Mechanical evaluation and comparison of 2 dynamic compression plate (DCP) systems. SAMPLE POPULATION: Eighteen cortical and 30 cancellous gapped fracture models. METHODS: DCP (4.5 mm narrow, 3.5 mm broad) with their respective cortical screws were applied to cortical bone density polyurethane foam blocks to construct center gap cortical fracture models that were tested in gap closing monotonic 4-point bending. DCP (4.5 mm narrow, 3.5 mm broad) with their respective cancellous screws were applied to cancellous bone density polyurethane foam blocks to construct eccentric gap cancellous fracture models. The cancellous constructs were tested in monotonic gap opening and gap closing cantilever bending and in cyclic axial loading. Univariate and multivariate repeated measures ANOVA were used to compare the maximum loads at failure of the 4.5 mm constructs and 3.5 mm constructs. RESULTS: The 4.5 mm narrow plating system withstood significantly higher loads at failure than the 3.5 mm broad plating system in 4-point bending (P<.0001) and gap opening cantilever bending (P<.0001). The 4.5 mm system failed in gap closing cantilever bending by plastic deformation of the plate, whereas the 3.5 mm system failed by screw pullout. There was no difference between the 2 systems in cyclic axial loading. CONCLUSION: Results indicate that the 4.5 mm narrow plating system has a mechanical advantage over the 3.5 mm broad plating system for stabilization of gapped fracture models. CLINICAL RELEVANCE: The 4.5 mm narrow plating system may be mechanically advantageous compared with the 3.5 mm broad plating system for stabilizing unreconstructed comminuted long bone fractures in large dogs.  相似文献   

2.
OBJECTIVE: To compare the biomechanical characteristics and mode of failure of two different dynamic compression plate (DCP) techniques for proximal interphalangeal joint (PIPJ) arthrodesis in horses. STUDY DESIGN: Randomized block-design blocking on horse (1-5), method of fixation (two 7-hole, 3.5-mm broad DCP vs two 5-hole, 4.5-mm narrow DCP), side (left, right), and end (front, hind). Constructs were loaded to failure in 3-point bending in a dorsal-to-palmar (plantar) direction. SAMPLE POPULATION: Ten paired limbs from 5 equine cadavers. METHODS: Two 7-hole, 3.5-mm broad dynamic compression plates (bDCP) were used in 1 limb of a pair, and two 5-hole 4.5-mm narrow dynamic compression plates (nDCP) were used on the contralateral limb. Plates were positioned abaxially across the dorsomedial and dorsolateral aspect of the PIPJ. Arthrodesis constructs were loaded (19 mm/s) in 3-point bending in a dorsal-to-palmar (plantar) direction using a materials-testing machine. Composite stiffness, yield point, and maximal bending moment at failure were obtained from bending moment-angular deformation curves. Data were analyzed using ANOVA, X(2) analysis, and Fisher's exact tests; the power of the test was calculated when differences were not significant. RESULTS: There were no significant differences in composite stiffness (P >.05; power = 0.8 @ delta = 21.9%), yield point (P >.05; power = 0.8 @ delta = 34.4%), or maximal bending moment (P >.05; power = 0.8 @ delta = 17.8%) between the two fixation techniques. For bDCP constructs, 11% (15 of 140) of the 3.5-mm screws were damaged; 7 of the screw heads pulled through plates where the plates bent, 1 screw head broke off, and 7 screws were bent or pulled out of the phalanx. For nDCP constructs, 8% (8 of 100) of the 4.5-mm screws were damaged; 1 screw head pulled through a plate, 1 screw head broke off, and 6 screws were bent or pulled out of the phalanx. CONCLUSIONS: There were no biomechanical or failure differences between bDCP and nDCP fixation of the PIPJ in horses when evaluated in single-cycle 3-point bending to failure. CLINICAL RELEVANCE: There is no biomechanical advantage to the use of two 7-hole, 3.5-mm bDCP in equine proximal interphalangeal arthrodesis compared with two 5-hole, 4.5-mm nDCP. Two 5-hole, 4.5-mm nDCP may be easier to place, whereas two 7-hole, 3.5-mm bDCP may provide more versatility in fracture repair.  相似文献   

3.
OBJECTIVES: To compare biomechanical properties of a prototype 5.5 mm tapered shaft cortical screw (TSS) and 5.5 mm AO cortical screw for an equine third metacarpal dynamic compression plate (EM-DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: Paired in vitro biomechanical testing of cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Adult equine cadaveric MC3 bones (n=12 pairs). METHODS: Twelve pairs of equine MC3 were divided into 3 groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of each, mid-diaphyseal osteotomized, MC3 pair. For each MC3 bone pair, 1 was randomly chosen to have the EM-DCP secured with four 5.5 mm TSS (2 screws proximal and distal to the osteotomy; TSS construct), two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws in the remaining holes. The control construct (AO construct) had four 5.5 mm AO cortical screws to secure the EM-DCP in the 2 holes proximal and distal to the osteotomy in the contralateral bone from each pair. The remaining holes of the EM-DCP were filled with two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws. All plates and screws were applied using standard AO/ASIF techniques. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the TSS construct were significantly greater (P<.00004 for yield and P<.00001 for failure loads) than those of the AO construct. Mean cycles to failure in 4-point bending of the TSS construct was significantly greater (P<.0002) than that of the AO construct. The mean yield load and composite rigidity in torsion of the TSS construct were significantly greater (P<.0039 and P<.00003, respectively) than that of the AO construct. CONCLUSION: The TSS construct provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: The results of this in vitro study support the conclusion that the EM-DCP fixation using the prototype 5.5 mm TSS is biomechanically superior to the EM-DCP fixation using 5.5 mm AO cortical screws for the stabilization of osteotomized equine MC3.  相似文献   

4.
OBJECTIVES: To compare the monotonic biomechanical properties of a prototype equine third metacarpal dynamic compression plate (EM-DCP) fixation with a double broad dynamic compression plate (DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional testing. The EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of one randomly selected bone from each pair. Two DCPs, 1 dorsally (10-hole, 4.5 mm broad) and 1 laterally (9-hole, 4.5 mm broad) were applied to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the EM-DCP fixation were significantly greater (P<.0001) than those of the double broad DCP fixation. Mean cycles to failure in 4-point bending of the EM-DCP fixation was significantly greater (P<.0008) than that of the double broad DCP fixation. Mean yield load, composite rigidity, and failure load in torsion of the EM-DCP fixation were significantly greater (P<.0035) than that of the double broad DCP fixation. CONCLUSION: The EM-DCP provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: Results of this in vitro study support the conclusion that the prototype EM-DCP fixation is biomechanically superior to the double broad DCP fixation for the stabilization of osteotomized equine MC3.  相似文献   

5.
OBJECTIVES: To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An LC-DCP (8-hole, 4.5 mm) was applied to the dorsal surface of 1 randomly selected bone from each pair. One DCP (8-hole, 4.5 mm broad) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: The mean 4-point bending yield load, yield bending moment, composite rigidity, failure load, and failure bending moment of LC-DCP fixation were significantly greater (P<.01) than those of broad DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.001) greater for broad DCP fixation compared with broad LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion was significantly (P<.02) greater for broad LC-DCP fixation compared with broad DCP fixation. CONCLUSION: Broad LC-DCP offers increased stability in static overload testing, however, it offers significantly less stability in cyclic fatigue testing. CLINICAL RELEVANCE: The clinical relevance of the cyclic fatigue data supports the conclusion that the broad DCP fixation is biomechanically superior to the broad LC-DCP fixation in osteotomized equine MC3 bones despite the results of the static overload testing.  相似文献   

6.
Objectives— To compare (1) pullout properties between 3.5 mm cortical and locking screws, and (2) mechanical properties and gap displacements between the 3.5 mm broad limited‐contact dynamic compression plate (LC‐DCP), broad dynamic compression plate (DCP), and narrow locking compression plate (LCP), during axial loading of plate‐stabilized diaphyseal fragments with an interfragmentary gap. Study Design— In vitro mechanical testing of implanted polyurethane foam (PUF) hollow cylinders that simulated compact or osteopenic diaphyseal bone. Sample Population— (1) Five cortical and locking screws and (2) 4 PUF‐plate constructs for each plate type; using high‐ and low‐density (0.8 and 0.32 g/cm3) cylinders. Methods— (1) Screws were completely extracted at 5 mm/min. (2) Plated constructs were axially compressed at 300 N/s for 10 cycles from 5 to 355 N to determine gap displacement during physiologic loading, followed by single cycle increasing load to failure. Results— Pullout properties were not different between screw types. All plate constructs had yield loads over 3 times trotting loads. Gap closure occurred with LC‐DCP and DCP constructs, but not LCP constructs. LCP construct properties were most similar to LC‐DCP and DCP construct properties in the low‐density model. Conclusion— All plate systems sustained physiologic limb loads. Only LCP constructs maintained some gap integrity, although LC‐DCP and DCP screws were placed in neutral position. Clinical Relevance— The LCP system is more likely than LC‐DCP and DCP systems, with neutrally positioned screws, to maintain a planned interfragmentary gap, although gap strains range from 0% to 15% across the 2 mm gap during a trot load.  相似文献   

7.
Objectives: To compare the monotonic biomechanical properties and fatigue life of a 5.5‐mm‐broad locking compression plate (5.5 LCP) fixation with a 4.5‐mm‐broad locking compression plate (4.5 LCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. Study Design: In vitro biomechanical testing of paired cadaveric equine MC3 with a middiaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Animal Population: Fifteen pairs of adult equine cadaveric MC3 bones. Methods: Fifteen pairs of equine MC3 were divided into 3 test groups (5 pairs each) for (1) 4‐point bending single cycle to failure testing, (2) 4‐point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An 8‐hole, 5.5 LCP was applied to the dorsal surface of 1 randomly selected bone from each pair and an 8‐hole, 4.5 LCP was applied dorsally to the contralateral bone from each pair using a combination of cortical and locking screws. All plates and screws were applied using standard ASIF techniques. All MC3 bones had middiaphyseal osteotomies. Mean test variable values for each method were compared using a paired t‐test within each group with significance set at P<.05. Results: Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4‐point bending, single cycle to failure, of the 5.5 LCP fixation were significantly greater than those of the 4.5 LCP fixation. Mean cycles to failure in 4‐point bending of the 5.5 LCP fixation (170,535±19,166) was significantly greater than that of the 4.5 LCP fixation (129,629±14,054). Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad 5.5 LCP fixation compared with the 4.5 LCP fixation. In single cycle to failure under torsion, the mean±SD values for the 5.5 LCP and the 4.5 LCP fixation techniques, respectively, were: yield load, 151.4±19.6 and 97.6±12.1 N m; composite rigidity, 790.3±58.1 and 412.3±28.1 N m/rad; and failure load: 162.1±20.2 and 117.9±14.6 N m. Conclusion: The 5.5 LCP was superior to the 4.5 LCP in resisting static overload forces (palmarodorsal 4‐point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4‐point bending. Clinical Relevance: These in vitro study results may provide information to aid in selection of an LCP for repair of equine long bone fractures.  相似文献   

8.
The objective of this study was to compare the biomechanical properties in a single cycle axial loading test and the types of failures in two constructs (a 3-hole 4.5-mm dynamic compression plate (DCP) and 7-hole 5.5-mm Y locking compression plate (Y-LCP)) in equine proximal interphalangeal joint (PIJ) arthrodesis. One limb in each pair was randomly assigned to PIJ arthrodesis using a 3-hole 4.5-mm DCP combined with two transarticular 5.5-mm cortical screws, whereas the contralateral limb was submitted to PIJ arthrodesis using a 7-hole Y-shaped 5.0-mm LCP in conjunction with one transarticular 4.5-mm cortical screw inserted through the central plate hole. Cortical screws were inserted in lag fashion. Constructs were submitted to a single axial load cycle to failure. Construct stiffness, load, and deformation were analyzed. Dynamic compression plate and Y-LCP arthrodesis constructs did not differ significantly and were equally resistant to axial loading under the conditions studied (DCP and Y-LCP group stiffness, 5685.22 N/mm and 6591.10 N/mm, respectively). Arthrodesis of the PIJ using a DCP and two transarticular 5.5-mm cortical screws or a Y-LCP yielded biomechanically equivalent outcomes under the test conditions considered. However, Y-LCP provides less impact in the palmar/plantar bone. Application of Y-LCP with unicortical screws has equivalent biomechanical characteristics of DCP and may be a safe option for PIJ arthrodesis, where potential trauma secondary to applying bicortical screws in the palmar/plantar aspect of the pastern can be avoided.  相似文献   

9.
A 3-week-old Standardbred filly had a non-weightbearing forelimb lameness caused by scapular neck fracture. The fracture was repaired with 2 dynamic compression plates placed 90 degrees to each other. A 10-hole 4.5-mm narrow dynamic compression plate was placed on the cranial aspect of the scapular spine, and a 10-hole 3.5-mm dynamic compression plate was placed caudal to the scapular spine. One year after surgery, the filly was not lame when exercising in the pasture, and muscle atrophy was not evident on the affected limb. Eighteen months after surgery, the filly was in race training with no apparent problems caused by fracture repair.  相似文献   

10.
Eighteen intact canine cadaver radii underwent nondestructive axial testing, and were osteotomized, plated, and retested. Each bone was tested with and without mediolateral or craniocaudal restriction of motion. Fixation of the osteotomies was performed under static compression with a cranially applied 5-hole 3.5 mm dynamic compression plate, a cranially applied 7-hole 3.5 mm T-plate, or a medially applied 7-hole 2.7 mm dynamic compression plate. There was no loss of axial stiffness after osteotomy and fixation, and there were no differences in axial stiffness between the methods of fixation. Mediolateral stiffness (bending around the craniocaudal axis) was consistently greater than craniocaudal stiffness (bending around the mediolateral axis) before and after osteotomy and plate fixation. There was no difference in the axial stiffness of otherwise intact radii when craniocaudal or mediolateral screw holes were drilled; however, all radii with craniocaudal screw holes and one radius with mediolateral screw holes fractured at a screw hole at high axial loads.  相似文献   

11.
Comparison was made of the holding power of 5.5 and 4.5 mm cortical orthopedic screws inserted into third metacarpal and metatarsal cadaver bones from 3- and 8-year-old horses. The tensile strength of these screws was tested mechanically. In nine comparative trials of these screws, 5.5 mm screws pulled out of bone in five trials at an average of 116.0 kg tensile force and broke in four trials at an average of 1383.2 kg. A 4.5 mm screw pulled out of bone at 834.5 kg in one trial, and screws broke at an average of 849.2 kg in eight trials. The larger 5.5 mm screw required a significantly greater (p = 0.022) pullout force than the mean force at 4.5 mm screw breakage. Fixation failure was due to screw breakage or bone shear, with 5.5 mm screws occasionally creating bone fragmentation during pullout. The average tensile breaking strengths of the 5.5 mm screws (1391.4 kg) and 4.5 mm screws (832.7 kg) determined mechanically were similar to forces at screw breakage during pullout testing in bone. Since the 5.5 mm screws have greater holding power and tensile strength than 4.5 mm screws, the use of the 5.5 mm screw in fracture repair in adult horses is recommended.  相似文献   

12.
Objective— To compare monotonic biomechanical properties and fatigue life of a broad locking compression plate (LCP) fixation with a broad limited contact dynamic compression plate (LC‐DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. Study Design— In vitro biomechanical testing of paired cadaveric equine MC3 with a mid‐diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Animal Population— Cadaveric adult equine MC3 bones (n=12 pairs). Methods— MC3 were divided into 3 groups (4 pairs each) for: (1) 4‐point bending single cycle to failure testing; (2) 4‐point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. The 8‐hole, 4.5 mm LCP was applied to the dorsal surface of 1 randomly selected bone from each pair. One 8‐hole, 4.5 mm LC‐DCP) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t‐test within each group. Significance was set at P<.05. Results— Mean yield load, yield bending moment, composite rigidity, failure load and failure bending moment, under 4‐point bending, single cycle to failure, of the LCP fixation were significantly greater than those of the LC‐DCP fixation. Mean cycles to failure for 4‐point bending was significantly greater for the LCP fixation compared with LC‐DCP fixation. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad LCP fixation compared with the LC‐DCP fixation. Conclusion— The 4.5 mm LCP was superior to the 4.5 mm LC‐DCP in resisting the static overload forces (palmarodorsal 4‐point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4‐point bending. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a biological plate for the repair of equine long bone fractures.  相似文献   

13.
Objectives: To compare in vitro monotonic biomechanical properties of an axial 3‐hole, 4.5 mm narrow locking compression plate (ELCP) using 5.0 mm locking screws and 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (ELCP–TLS) with an axial 3‐hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP–TLS) for equine proximal interphalangeal (PIP) joint arthrodesis. Design: Experimental. Animal Population: Cadaveric adult equine forelimbs (n=18 pairs). Methods: For each forelimb pair, 1 PIP joint was stabilized with an axial ELCP using 5.0 mm locking screws and 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 PIP joint with an axial 3‐hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression, 6 construct pairs were tested for cyclic fatigue under axial compression, and 6 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t‐test within each group with statistical significance set at P<.05. Results: Mean yield load, yield stiffness, and failure load under axial compression, single cycle to failure, of the DCP–TLS fixation were significantly greater than those of the LCP–TLS fixation. There was no significant difference between the mean number of cycles to failure in axial compression of the LCP–TLS and the DCP–TLS fixations. Mean yield load, yield stiffness, and failure load under torsion, single cycle to failure, of the LCP–TLS fixation were significantly greater than those of the DCP–TLS fixation. Conclusion: The DCP–TLS construct provided significantly greater stability under axial compression in single cycle to failure than the ELCP–TLS construct, the ELCP–TLS construct provided significantly greater stability under torsional loading in single cycle to failure than the DCP–TLS construct, and there was no significant difference in stability between the 2 constructs for cyclic loading under axial compression.  相似文献   

14.
Objectives— To compare monotonic biomechanical properties and fatigue life of a 5.5 mm broad limited‐contact dynamic compression plate (5.5‐LC‐DCP) fixation with a 4.5 mm broad LC‐DCP (4.5‐LC‐DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. Study Design— In vitro biomechanical testing of paired cadaveric equine MC3 with a mid‐diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Sample Population— Adult equine cadaveric MC3 bones (n=18 pair). Methods— MC3 were divided into 3 test groups (6 pairs each) for: (1) 4‐point bending single cycle to failure testing; (2) 4‐point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. The 8‐hole, 5.5 mm broad LC‐DCP (5.5‐LC‐DCP) was applied to the dorsal surface of 1 randomly selected bone from each pair. One 8‐hole, 4.5 mm broad LC‐DCP (4.5‐LC‐DCP) was applied dorsally to the contralateral bone from each pair. Plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t–test within each group. Significance was set at P<.05. Results— Mean yield load, yield bending moment, composite rigidity, failure load and failure bending moment under 4‐point bending, single cycle to failure, of the 5.5‐LC‐DCP fixation were significantly greater (P<.024) than those of the 4.5‐LC‐DCP fixation. Mean cycles to failure for 4‐point bending was significantly (P<.05) greater for the 4.5‐LC‐DCP fixation compared with the 5.5‐LC‐DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion for the 5.5‐LC‐DCP fixation was not significantly different (P>.05) than those with the 4.5‐LC‐DCP fixation. Conclusion— 5.5‐LC‐DCP fixation was superior to 4.5‐LC‐DCP fixation in resisting the static overload forces under palmarodorsal 4‐point bending. There was no significant difference between 5.5‐LC‐DCP fixation and 4.5‐LC‐DCP fixation in resisting static overload forces under torsion; however, the 5.5‐LC‐DCP offers significantly less stability (80% of that of the 4.5‐LC‐DCP) in cyclic fatigue testing. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a biological plate for long bone fracture repair in horses.  相似文献   

15.
Objective—To determine and compare the in vitro pullout strength of 5.5-mm cortical versus 6.5-mm cancellous bone screws inserted in the diaphysis and metaphysis of adult equine third metacarpal (MCIII) bones, in threaded 4.5-mm cortical bone screw insertion holes that were then overdrilled with a 4.5-mm drill bit to provide information relevant to the selection of a replacement screw if a 4.5-mm cortical screw is stripped. Study Design—In vitro pullout tests of 5.5-mm cortical and 6.5-mm cancellous screws in equine MCIII bones. Sample Population—Two independent cadaver studies each consisting of 14 adult equine MCIII bones. Methods—Two 4.5-mm cortical screws were placed either in the middiaphysis (study 1) or distal metaphysis (study 2) of MCIII bones. The holes were then overdrilled with a 4.5-mm drill bit and had either a 5.5-mm cortical or a 6.5-mm cancellous screw inserted; screw pullout tests were performed at a rate of 0.04 mm/second until screw or bone failure occurred. Results—In diaphyseal bone, the screws failed in all tests. Tensile breaking strength for 5.5-mm cortical screws (997.5 ± 49.3 kg) and 6.5-mm cancellous screws (931.6 ± 19.5 kg) was not significantly different. In metaphyseal bone, the bone failed in all tests. The holding power for 6.5-mm cancellous screws (39.1 ± 4.9 kg/mm) was significantly greater than 5.5-mm cortical screws (23.5 ± 3.5 kg/mm) in the metaphysis. There was no difference in the tensile breaking strength of screws in the diaphysis between proximal and distal screw holes; however, the holding power was significantly greater in the distal, compared with the proximal, metaphyseal holes. Conclusions—Although tensile breaking strength was not different between 5.5-mm cortical and 6.5-mm cancellous screws in middiaphyseal cortical bone, holding power of 6.5-mm cancellous screws was greater than 5.5-mm cortical screws in metaphyseal bone of adult horses. Clinical Relevance—If a 4.5-mm cortical bone screw strips in MCIII diaphyseal bone of adult horses, either a 5.5-mm cortical or 6.5-mm cancellous screw, however, would have equivalent pullout strengths. A 6.5-mm cancellous screw, however, would provide greater holding power than a 5.5-mm cortical screw in metaphyseal bone.  相似文献   

16.
Objectives: To compare the biomechanical characteristics of 2 arthrodesis techniques for the equine proximal interphalangeal joint (PIP) using either a 3‐hole 4.5 mm locking compression plate (LCP) or 3‐hole 4.5 mm narrow dynamic compression plate (DCP), both with 2 transarticular 5.5 mm cortex screws. Study Design: Experimental. Sample Population: Cadaveric adult equine forelimbs (*n=6 pairs). Methods: For each forelimb pair, 1 limb was randomly assigned to 1 of 2 treatment groups and the contralateral limb by default to the other treatment group. Construct stiffness, gap formation across the PIP joint, and rotation about the PIP joint were determined for each construct before cyclic axial loading and after each of four, 5000 cycle loading regimens. After the 20,000 cycle axial loading regimen, each construct was loaded to failure. Results: There were no significant differences in construct stiffness, gap formation, or sagittal plane rotation between the LCP and DCP treatment groups at any of the measured time points. Conclusion: Biomechanically, fixation of the equine PIP joint with a 3‐hole 4.5 mm LCP is equivalent to fixation with a 3‐hole 4.5 mm narrow DCP under the test conditions used.  相似文献   

17.
OBJECTIVE: To compare the biomechanical characteristics and mode of failure of 2 techniques using parallel 5.5 mm screws for pastern joint arthrodesis in horses. STUDY DESIGN: Randomized block design, for horse (1-5), method of fixation (two 5.5 mm screws versus three 5.5 mm screws), side (right, left), and end (front, hind). Constructs were tested to failure in 3-point bending. SAMPLE POPULATION: Twenty limbs (5 cadavers). METHODS: A combined aiming device was used to facilitate screw placement. Two parallel 5.5 mm screws were inserted in lag fashion in 1 limb of a pair, and three 5.5 mm screws were inserted in the contralateral limb. Constructs were then tested in 3-point bending in a dorsal-to-palmar (plantar) direction using a materials testing machine at a loading rate of 19 mm/s. Maximal bending moment at failure and stiffness were obtained from bending moment-angular deformation curves. RESULTS: There was no significant difference between two and three 5.5 mm screw constructs for bending moment and stiffness (P<.05). All constructs ultimately failed by bone fracture or screw bending. For proximal interphalangeal (PIP) joint arthrodesis constructs loaded in 3-point bending, no significant effect of treatment, side, or end on maximal bending moment or stiffness was detected. CONCLUSIONS: Two 5.5 mm cortical screws inserted in parallel should provide a surgically simpler and equally strong PIP joint arthrodesis compared with three 5.5 mm cortical screws. CLINICAL RELEVANCE: Two 5.5 mm cortical screws inserted in parallel for PIP joint arthrodesis should perform similarly under conditions used in this study, as three 5.5 mm screws inserted in a similar manner, when loaded under bending.  相似文献   

18.
Objectives— To compare in vitro monotonic biomechanical properties of an axial 3‐hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP‐TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3‐TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Study Design— Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Sample Population— Cadaveric adult equine forelimbs (n=15 pairs). Methods— For each forelimb pair, 1 PIP joint was stabilized with an axial 3‐hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t‐test within each group with statistical significance set at P<.05. Results— Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP‐TLS fixation were significantly greater than those of the 3‐TLS fixation. Mean cycles to failure in axial compression of the DCP‐TLS fixation was significantly greater than that of the 3‐TLS fixation. Conclusion— The DCP‐TLS was superior to the 3‐TLS in resisting the static overload forces and in resisting cyclic fatigue. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.  相似文献   

19.
Objectives: To compare the number of cycles to failure of 4.5 mm broad dynamic compression plates (DCP), 4.5 mm broad limited‐contact dynamic compression plates (4.5‐LC‐DCP), and 5.5 mm broad limited‐contact dynamic compression plates (5.5‐LC‐DCP) having a rough (denoted by a prefix R‐) versus a standard smooth contact surface for the fixation of osteotomized equine 3rd metacarpal (MC3) bones. Study Design: Experimental. Animal Population: Fifteen pairs of adult equine cadaveric MC3 bones. Methods: Fifteen pairs of equine MC3 were divided into 3 test groups (5 pairs each) for comparison of (1) R‐DCP fixation with DCP fixation, (2) R‐4.5‐LC‐DCP fixation with 4.5‐LC‐DCP fixation, and (3) R‐5.5‐LC‐DCP fixation with 5.5‐LC‐DCP fixation to repair osteotomized equine MC3 bones under palmarodorsal 4‐point bending cyclic fatigue testing. For each group an 8‐hole plate with rough contact surface was applied to the dorsal surface of one randomly selected bone from each pair and a corresponding 8‐hole plate with smooth contact surface was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean number of cycles to failure for each method were compared using a paired t‐test within each group. Significance was set at P<.05. Results: Mean cycles to failure ± standard deviation was significantly greater for the R‐DCP fixation (230,025 ± 23,129) compared with the DCP fixation (103,451 ± 14,556), for the R‐4.5‐LC‐DCP fixation (99,237 ± 14,390) compared with the 4.5‐LC‐DCP fixation (46,464 ± 6325) and for the R‐5.5‐LC‐DCP fixation (65,113 ± 7796) compared with the 5.5‐LC‐DCP fixation (34,224 ± 3835). Conclusion: For the fixation of osteotomized MC3 bones, the constructs with plates having rough contact surface were superior to the corresponding constructs with plates having standard smooth contact surfaces in resisting cyclic fatigue under palmarodorsal 4‐point bending.  相似文献   

20.
Twenty-three canine pelves were tested bilaterally to determine the stiffness and strength of intact ilium and stabilized oblique iliac osteotomies that simulated a common clinical fracture. Fixation systems tested were three 4.0 mm cancellous screws inserted ventral to dorsal across the osteotomy site and one laterally placed five hole 3.5 mm dynamic compression plate. Specimens were mechanically tested to failure under torsional, axial, or axial plus bending loads. Lag screw fixation was stiffer and stronger than plate fixation in all testing modes. The differences were statistically significant (p less than .05) in the torsional and axial plus bending loading modes. Fatigue testing was performed on implanted specimens with low-level cyclic loading under axial plus bending loading conditions. Physiologic loading conditions failed to produce mechanical failure of either fixation system after 100,000 cycles.  相似文献   