首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 19 毫秒
1.
2.
3.
The present case report describes three heavy dogs, Caucasian Shepherd breed, with chronic complete traumatic rupture of Achilles tendon, which was repaired with two types of sutures. Surgical treatment involved shortening the Achilles tendon, and using a locking loop suture technique and own suture technique with four buttons. Additionally, positional screw and cast supported the sutures. Twelve months postoperatively no discomfort and lameness were observed on clinical examination. This paper shows that treatment of chronic complete rupture of Achilles tendon with locking loop suture and own suture technique gives good results.  相似文献   

4.
5.
6.
OBJECTIVE: To test the failure strength and energy of 2 bioabsorbable implants applied to transected deep digital flexor tendons (DDFT) from adult horses. STUDY DESIGN: Ex vivo biomechanical experiment. SAMPLE POPULATION: Twelve pairs of deep digital flexor tendons harvested from the forelimbs of fresh equine cadavers. METHODS: Poly-L-lactic acid tendon plates were custom manufactured for application to the cylindrical surface of an adult equine deep digital flexor tendon. Twelve pairs of DDFTs were transected 2 cm distal to the insertion of the distal check ligament of the deep digital flexor tendon. One tendon of each pair was randomly selected for repair with a biodegradable plate or a 3-loop pulley method. Size 2 polydioxanone suture was used in both repairs. Repairs were tested in tension to failure, with peak force (PF) and total energy (TE) at repair failure recorded in Newtons (N) and Joules (J), respectively. A paired t-test was used for statistical evaluation with a significant level set at P< or = .05. RESULTS: Mean+/-SD PF for failure of plated tendons (1507.08+/-184.34 N) was significantly greater than for sutured tendons (460.86+/-60.93 N). TE was also significantly greater for failure of plated tendons versus sutured tendons. CONCLUSIONS: Plate fixation of transected cadaver DDFTs appear to have superior immediate failure strength than 3-loop pulley repairs. CLINICAL RELEVANCE: Whereas in vivo testing is required, a bioabsorbable tendon plate may provide initial increased strength to support tendon healing and decrease external coaptation requirements.  相似文献   

7.
The purpose of this study was to compare postoperative wound healing in canine ovariohysterectomy following the use of an absorbable monofilament poliglecaprone 25 suture in 2 different skin closure techniques, the buried continuous subcuticular (BCS) suture pattern and the simple interrupted (SI) suture pattern. These 2 skin closure techniques were evaluated against a nonabsorbable polypropylene monofilament suture in an SI pattern. Wounds were assessed by using a semiquantitative scoring system at 18 to 24 hours and 10 to 14 days, postoperatively. Results indicated that the BCS closure using poliglecaprone 25 demonstrated a higher rate of tissue reactivity initially (18-24 hours postoperatively), as compared with the SI closure using either suture material. By 10 to 14 days postoperatively, poliglecaprone 25 used in a BCS closure was associated with significantly lower wound scores than was the same material used in an SI closure. It was concluded that the BCS closure may effect a better cosmetic appearance to the skin closure in a canine ovariohysterectomy at the time of the recheck appointment. Furthermore, by obviating the need for suture removal, use of the BCS pattern may eliminate the requirement for this return appointment.  相似文献   

8.
9.
10.
OBJECTIVE: To describe a modified 3-loop pulley suture pattern for the reattachment of canine tendons to bone along with a biomechanical comparison with the locking-loop suture. STUDY DESIGN: In vitro biomechanical study and clinical case report. ANIMALS OR SAMPLE POPULATION: Biomechanical study: 10 paired gastrocnemius tendons and calcaneii harvested from 5 canine cadavers. Case report: a Doberman with avulsion of the gastrocnemius tendon of insertion. METHODS: Biomechanical study: paired tendons were reattached to the calcaneus with either a modified 3-loop pulley pattern or a locking-loop pattern. Tensile loading to failure was performed. A direct, non-contact, method of gap measurement, using digital video, was used to measure gap formation. Load required to initiate gap formation (defined as load at a 1 mm gap) and to produce a 3 mm gap was evaluated in addition to maximum load and gap at failure. RESULTS: Mean (+/-SEM) 1 mm gap loads were 31.0+/-4.2 and 17.2+/-2.5 N, mean 3 mm gap loads were 49.1+/-2.4 and 28.9+/-3.2 N, and mean maximum loads were 72.9+/-4.3 and 55.8+/-2.2 N for the modified 3-loop pulley suture and the locking-loop suture, respectively. These differences were statistically significant (P<.05). The gap at failure was similar for both repairs. The clinical case remained sound 7 months postoperatively. CONCLUSIONS: A modified 3-loop pulley pattern is biomechanically superior to a locking-loop pattern for reattachment of the canine gastrocnemius tendon to bone and may be suitable for clinical use. CLINICAL RELEVANCE: Tendon repairs with a gap >3 mm are reported to be at increased risk of rupture during the first 6 weeks postoperatively. A modified 3-loop pulley pattern resists gap formation better than a locking-loop pattern.  相似文献   

11.
OBJECTIVE: To compare olecranon fragment stability between the classic tension band wire (TBW) technique with the wire placed either in contact with (Arbeitsgemeinschaft für Osteosynthesefragen [AO]), or not in contact with, a Kirschner (K)-wire (AOW) to 2 novel wire patterns: a dual interlocking single loop (DISL) and a double loop (DL). STUDY DESIGN: Ex vivo mechanical evaluation on cadaveric bones. SAMPLE POPULATION: Canine ulnae (n=40) with olecranon osteotomies repaired with 2 K-wires and 1 of 4 TBW constructs. METHODS: Single load to failure applied through the triceps tendon. Displacement was measured from images captured from digital video. Techniques were compared based on the load resisted when the olecranon fragment was displaced 0.5, 1, and 2 mm. RESULTS: At 0.5 mm of displacement, the DISL construct resisted more load than the AOW construct (505 versus 350 N; P=.05). AO and DL constructs resisted an intermediate load (345 and 330 N, respectively). There was no significant difference between groups at 1 mm of displacement. At 2 mm of displacement, DL (785 N) resisted more load than AO (522 N, P=.01) and AOW (492 N, P=.03) groups. CONCLUSIONS: DISL constructs provided similar stability to classic TBW constructs whereas DL constructs were more stable at higher loads. CLINICAL RELEVANCE: The DL construct is easy to perform, less bulky, and provides comparable fragment stability to standard TBW techniques at functional loads. Surgical method is important for optimal performance of all TBW constructs.  相似文献   

12.
Objective— To compare initial femoral fixation properties of a new implant, Graftgrab (GG), with 2 established methods of extra-articular femoral graft fixation, spiked washers (SW) and bone staples (ST).
Study Design— Experimental in vitro cohort study.
Methods— Canine semitendinosus–gracilis tendon grafts were passed through bone tunnels and fixed to the lateral surface of femoral condyles with spiked washers, bone staples, or new implant prototypes. The fixations were tested to failure with a single-cycle load at a rate of 50 mm/min. Failure and yield strength, stiffness, energy, and elongation were determined from load–displacement curves and failure modes were recorded.
Results— The graft failed midsubstance in 4 SW, 4 ST, and 1 GG fixations. In 3 SW, 3 ST, and 1 GG specimens, the graft slipped from the fixation. The graft ruptured at the clip (3) and the intra-articular (2) surface of the bone tunnel in the remaining GG specimens. There were no significant differences between fixation groups in femoral tunnel length, femoral width, or the mechanical properties evaluated.
Conclusions— The initial in vitro mechanical properties of the new fixation implant are comparable with those of spiked washers and bone staples.
Clinical Relevance— The initial mechanical performance of the new implant tested in this study was similar to those of comparable, established implants. The new implant is novel and may be useful for human anterior and veterinary cranial cruciate ligament graft reconstruction fixation.  相似文献   

13.
14.
REASONS FOR PERFORMING STUDY: Previous studies have implicated tension in the deep digital flexor tendon (DDFT) in the rotation of the distal phalanx (DP) after the breakdown of the dorsal laminae caused by laminitis. Howeveer, once the DP has rotated, the DDFT should become shorter, reducing the force it exerts on the DP. OBJECTIVE: To compare DDFT force and ground reaction forces (GRFs) in normal ponies and ponies with rotation of the DP as a sequel to laminitis. METHODS: Six normal ponies (Group 1) and 6 sound ponies with 6-13 degrees of rotation of the DP in relation to the dorsal hoof wall (Group 2) were assessed at trot using forceplate and motion analysis. The force in the DDFT was calculated by assuming that the extending moment at the distal interphalangeal (DIP) joint resulting from the GRF was equal to the flexing moment created by the force in the DDFT during the stance phase (inverse dynamics). RESULTS: In early stance, the peak DDFT force (mean+/-s.d.) in the normal ponies was 1.92+/-1.63 N/kg. However, in Group 2, the point of zero moment was palmar to the centre of rotation of the DIP joint for the first 40% of stance and hence DDFT force was zero. Force in the DDFT reached a peak of 10.00+/-3.56 N/kg at 60.7+/-5.6% of stance in Group 1 and 6.41+/-1.37 N/kg at 79.2+/-9.6% of stance in Group 2. CONCLUSIONS: DDFT force in Group 2 laminitic ponies was much reduced until late stance, when it neared normal values. POTENTIAL RELEVANCE: Further studies of ponies with rotation of the DP as a sequel to laminitis should assist farriery aimed at reducing the force in the DDFT through the breakover phase of stance to protect damaged dorsal laminae.  相似文献   

15.
Definitive diagnosis of a deep digital flexor tendon insertional lesion within the right fore foot was made by magnetic resonance imaging (MRI) examination and the lesion subsequently treated by injection with platelet‐rich plasma. MRI was used to guide positioning of the needle to achieve highly accurate injection. The volume injected was found to approximate the calculated lesion volume. On the basis of experience with this case, MRI‐guided injection of insertional deep digital flexor tendon lesions of the foot of horses under general anaesthesia is practicable. This technique is likely to be more accurate than the other techniques described (computed tomography, ultrasonography) and carries no risk of exposure to radiation (radiography).  相似文献   

16.
OBJECTIVE: To evaluate a model for atopic dermatitis (AD) and to measure the effect of sensitization in Beagles genetically predisposed to produce high serum concentrations of allergen specific IgE. ANIMALS: 22 laboratory Beagles. PROCEDURE: Seventeen dogs were sensitized from birth to 3 allergens (recombinant birch pollen, Dermatophagoides pteronyssinus, and D farinae). Five nonsensitized dogs from the same litters served as controls. Clinical scoring, regular intradermal testing, measurement of serum concentrations of allergen-specific IgE, and collection of biopsy specimens of skin at 23, 32, and 43 weeks of age were performed. Serial tissue sections were stained for identification of IgE+ cells, mast cells and their subtypes, T-cells, Langerhans cells, and major histocompatibility complex class-II+ cells. At the age of 15 months, dogs were continuously exposed to 2 microg of mite allergen/g of dust. RESULTS: Sensitized dogs had positive intradermal test reactions and significantly higher serum concentrations of allergen specific IgE, compared with nonsensitized dogs. In sensitized and nonsensitized dogs, a significantly higher number of mast cells was found at predilection sites, compared with the control biopsy site. The number of mast cells at predilection sites increased with age. Sensitization significantly increased the number of epidermal Langerhans cells by 23 weeks of age. The number of epidermal Langerhans cells significantly increased in nonsensitized dogs by 32 weeks of age. Clinical scoring only revealed mild transient erythema in some dogs. CONCLUSIONS: increases in concentrations of serum allergen-specific IgE and exposure to allergens is not sufficient to induce clinical signs of AD in genetically predisposed dogs.  相似文献   

17.
OBJECTIVE: To compare anatomic reduction and the biomechanical properties of a circular external skeletal fixator (CESF) construct to pin and tension band wire (PTBW) fixation for the stabilization of olecranon osteotomies in dogs. STUDY DESIGN: Cadaveric study. ANIMALS: Forelimbs from 12 skeletally mature mixed-breed dogs, weighing 23 to 28 kg. METHODS: An olecranon osteotomy was stabilized with either a CESF construct or PTBW fixation. A single distractive load to failure was applied to each specimen through the triceps tendon. Osteotomy reduction and biomechanical properties were compared between fixation groups. RESULTS: Reduction was not significantly different (gap: P =.171; malalignment: P =.558) between fixation groups. Osteotomies stabilized with the CESF had greater stiffness (P <.0001) and maximum load sustained (P <.0001) compared to PTBW fixation. There was no significant difference for yield load (P =.318) or for load at 1 mm of axial displacement (P =.997) between fixation groups. Failure of fixation occurred by bending of the intramedullary Steinmann pin and the fixation wires in the CESF specimens and by untwisting of the tension band wire knot with pullout and bending of the Kirschner wires in the PTBW specimens. CONCLUSIONS: Specimens stabilized with the CESF construct had similar reduction and yield load, greater stiffness and maximum load sustained, and less elastic deformation than specimens stabilized with PTBW fixation. CLINICAL RELEVANCE: The CESF construct may provide a biomechanically favorable alternative to PTBW fixation for stabilization of olecranon osteotomies in dogs, and its application warrants clinical investigation.  相似文献   

18.
19.
Assignment of individual cattle to a specific breed can often not rely on pedigree information. This is especially the case for local breeds for which the development of genomic assignment tools is required to allow individuals of unknown origin to be included to their herd books. A breed assignment model can be based on two specific stages: (a) the selection of breed-informative markers and (b) the assignment of individuals to a breed with a classification method. However, the performance of combination of methods used in these two stages has been rarely studied until now. In this study, the combination of 16 different SNP panels with four classification methods was developed on 562 reference genotypes from 12 cattle breeds. Based on their performances, best models were validated on three local breeds of interest. In cross-validation, 14 models had a global cross-validation accuracy higher than 90%, with a maximum of 98.22%. In validation, best models used 7,153 or 2,005 SNPs, based on a partial least squares-discriminant analysis (PLS-DA) and assigned individuals to breeds based on nearest shrunken centroids. The average validation sensitivity of the first two best models for the three local breeds of interest were 98.33% and 97.5%. Moreover, results reported in this study suggest that further studies should consider the PLS-DA method when selecting breed-informative SNPs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号