首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
2.
OBJECTIVE: To report the use of a nylon suture system (Canine Cranial Cruciate Ligament Repair System; Securos Inc Veterinary Orthopedics) as a prosthesis for equine laryngoplasty. STUDY DESIGN: Experimental and prospective clinical study. ANIMALS: Cadaver specimens (n = 5) and 7 horses with left laryngeal hemiplegia. METHODS: A commercially available monofilament nylon suture system was implanted as a laryngeal prosthesis. Arytenoid cartilage abduction was achieved with a tensioning device applied to the suture prosthesis during transnasal endoscopic observation. Suture fixation was achieved with crimping clamps and a crimping device. RESULTS: The nylon suture system was suitable as a laryngeal prosthesis for arytenoid cartilage abduction. The ratchet mechanism of the tensioning device facilitated abduction of the arytenoid cartilage and suture fixation was achieved by the crimped clamp without any loss of tension. Postoperatively, there was a slight loss of tension in 4 horses and complete loss of tension in 1 horse because of cartilage failure. After convalescence, none of the horses had abnormal respiratory noise, exercise intolerance or cough. CONCLUSIONS: A nylon suture system designed for canine cranial cruciate ligament repair was used successfully as a laryngeal prosthesis and facilitated control of the degree of arytenoid cartilage abduction during laryngoplasty. CLINICAL RELEVANCE: For improved control of the degree of arytenoid cartilage abduction during laryngoplasty, use of a nylon suture system with metal crimps should be considered.  相似文献   

3.
OBJECTIVES : To compare the biomechanical properties of a prototype intramedullary pin-plate (IMPP) implant specifically designed for equine metacarpophalangeal (MCP) arthrodesis with a dynamic compression plate (DCP) system. STUDY DESIGN : In vitro biomechanical testing of paired cadaveric equine forelimbs with a simulated traumatic disruption of the suspensory apparatus, stabilized by one of two methods for MCP arthrodesis. ANIMAL POPULATION : Twenty-one pairs of adult equine cadaveric forelimbs. METHODS : Each forelimb had the distal sesamoidean ligaments severed to create a disrupted suspensory apparatus. For each forelimb pair, the MCP joint was stabilized with the IMPP in one limb, and a DCP in the other limb. Seven matching limb pairs were tested in axial compression in a single cycle to failure, 7 matching limb pairs were tested in torsion in a single cycle to failure, and 7 matching limb pairs were fatigued tested in axial compression. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS : The mean yield load, yield stiffness, and failure load (axial compression, torsional loading) was significantly greater for the IMPP compared with the DCP system. Mean cycles to failure for axial compression was significantly greater for the IMPP compared with the DCP system. Significance in all tests was P<.0001. CONCLUSION : The IMPP was superior to the DCP system in resisting the biomechanical forces most likely to cause failure of MCP joint arthrodesis. CLINICAL RELEVANCE : The IMPP implant should be considered for MCP arthrodesis in horses with traumatic disruption of the suspensory apparatus. The specific design of the IMPP implant may facilitate equine MCP arthrodesis and avoid convalescent complications related to cyclic fatigue.  相似文献   

4.
OBJECTIVES: To compare the monotonic biomechanical properties of a prototype equine third metacarpal dynamic compression plate (EM-DCP) fixation with a double broad dynamic compression plate (DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional testing. The EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of one randomly selected bone from each pair. Two DCPs, 1 dorsally (10-hole, 4.5 mm broad) and 1 laterally (9-hole, 4.5 mm broad) were applied to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the EM-DCP fixation were significantly greater (P<.0001) than those of the double broad DCP fixation. Mean cycles to failure in 4-point bending of the EM-DCP fixation was significantly greater (P<.0008) than that of the double broad DCP fixation. Mean yield load, composite rigidity, and failure load in torsion of the EM-DCP fixation were significantly greater (P<.0035) than that of the double broad DCP fixation. CONCLUSION: The EM-DCP provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: Results of this in vitro study support the conclusion that the prototype EM-DCP fixation is biomechanically superior to the double broad DCP fixation for the stabilization of osteotomized equine MC3.  相似文献   

5.
OBJECTIVE: To examine the effect of cordopexy, laryngoplasty, and cordopexy combined with a modified laryngoplasty on airway mechanics. STUDY DESIGN: Experimental airway mechanics were determined by subjecting equine cadaveric larynges to airflows similar to inspiratory airflow of exercising horses. ANIMALS OR SAMPLE POPULATION: Twenty equine larynges. METHODS: Using cadaveric larynges, we developed and tested a new technique of arytenoid cartilage abduction. All larynges had the right arytenoid cartilage abducted to mimic the degree of arytenoid abduction that occurs at maximal exertion in live horses. Three surgical techniques were used to stabilize the left arytenoid cartilage of treated larynges; the left arytenoid cartilage was not stabilized in control larynges. Technique 1: Cordopexy--a suture was placed between the vocal ligament and the lamina of the thyroid cartilage. Technique 2: Standard laryngoplasty--a suture was placed between the muscular process of the arytenoid cartilage and the caudomedial aspect of the cricoid cartilage. Technique 3: Cordopexy plus modified laryngoplasty--the cordopexy suture was placed with a second suture between the horizontal ridge rostral to the muscular process of the left arytenoid cartilage and the lamina of the thyroid cartilage. Translaryngeal impedances (TI) were determined for each surgical technique by subjecting the larynges to increasing airflows and measuring the translaryngeal pressure differences. The arytenoid right to left angle quotient (RLQ) and the glottic cross-sectional area (CSA) were also measured. RESULTS: At maximal airflow, the adjusted means for the arytenoid RLQ and the TI for the cordopexy plus modified laryngoplasty (1.48 +/- 0.04, 0.69 +/- 0.05 cm H2O/L/s) and the standard laryngoplasty (1.39 +/- 0.04, 0.78 cm H2O/L/s) were different (P < .05) from values obtained after cordopexy alone (2.74 +/- 0.37, 1.76 +/- 0.48 cm H2O/L/s) or in control larynges (3.66 +/- 0.54, 4.16 +/- 0.96 cm H2O/L/s). Overall, a cordopexy plus modified laryngoplasty (9.69 cm2), a standard laryngoplasty (9.34 cm2), and a cordopexy alone (9 cm2) resulted in an increased glottic CSA greater than that for control larynges (6.94 cm2; P = .0001). CONCLUSIONS: Cordopexy alone did not improve airflow in a left laryngeal hemiplegic model. Cordopexy plus modified laryngoplasty was as efficacious as the standard laryngoplasty in alleviating the effects of left laryngeal hemiplegia on TI, glottic CSA, and arytenoid RLQ. CLINICAL RELEVANCE: Fixation of the vocal cord (cordopexy) in addition to a laryngoplasty procedure may prove useful in the surgical treatment of equine laryngeal hemiplegia.  相似文献   

6.
Objective: To determine whether ventriculocordectomy (VCE) performed before prosthetic laryngoplasty (PL) results in increased rima glottidis size compared with PL alone. Study Design: Experimental study. Animals: Equine cadaver larynges (n=13). Methods: Right arytenoid cartilages were maximally abducted using a standard PL technique. Standard PLs were then performed on the left side and the force required to maximally abduct the left arytenoid cartilage recorded (Fmax). Photographs were taken of the rima glottidis at zero force and at five equal levels of force up to Fmax. The force applied was released, left VCE performed, and photographs repeated. Arytenoid left:right angle quotients (LRQ) and glottic cross‐sectional area ratios (CSAR) were calculated at each force level in each condition (PL and VCE‐PL). Results: Mean LRQ and CSAR for both PL and VCE‐PL increased with increasing force, initially rapidly before plateauing at ~50% of Fmax. LRQ and CSAR were significantly greater for VCE‐PL than for PL (P<.001). When VCE was performed before PL, 12% less force was required to achieve an LRQ of 0.8, and 45% less for a CSAR of 0.8. Conclusions: In vitro, VCE performed before PL enables the arytenoid cartilage to be abducted to a greater degree for a given PL suture force.  相似文献   

7.
OBJECTIVES: To compare biomechanical properties of a prototype 5.5 mm tapered shaft cortical screw (TSS) and 5.5 mm AO cortical screw for an equine third metacarpal dynamic compression plate (EM-DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: Paired in vitro biomechanical testing of cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Adult equine cadaveric MC3 bones (n=12 pairs). METHODS: Twelve pairs of equine MC3 were divided into 3 groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of each, mid-diaphyseal osteotomized, MC3 pair. For each MC3 bone pair, 1 was randomly chosen to have the EM-DCP secured with four 5.5 mm TSS (2 screws proximal and distal to the osteotomy; TSS construct), two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws in the remaining holes. The control construct (AO construct) had four 5.5 mm AO cortical screws to secure the EM-DCP in the 2 holes proximal and distal to the osteotomy in the contralateral bone from each pair. The remaining holes of the EM-DCP were filled with two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws. All plates and screws were applied using standard AO/ASIF techniques. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the TSS construct were significantly greater (P<.00004 for yield and P<.00001 for failure loads) than those of the AO construct. Mean cycles to failure in 4-point bending of the TSS construct was significantly greater (P<.0002) than that of the AO construct. The mean yield load and composite rigidity in torsion of the TSS construct were significantly greater (P<.0039 and P<.00003, respectively) than that of the AO construct. CONCLUSION: The TSS construct provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: The results of this in vitro study support the conclusion that the EM-DCP fixation using the prototype 5.5 mm TSS is biomechanically superior to the EM-DCP fixation using 5.5 mm AO cortical screws for the stabilization of osteotomized equine MC3.  相似文献   

8.
Investigations were carried out to determine whether measurements of total respiratory resistance (TRR) made in resting animals could detect changes due to laryngeal hemiplegia. Control values of TRR were obtained in eight ponies and in six of these the measurements were repeated after division of the left recurrent laryngeal nerve in the mid-cervical region; two were retained as controls. A further set of measurements were made before two of the operated animals were subjected to left laryngoventriculectomy (Hobday operation). A laryngoplasty ('tie-back' operation) was performed on another two animals. Measurements of TRR were made at three-monthly intervals on all eight ponies for the next two years. Endoscopic examination of the larynx was carried out at the time of the measurements. All ponies showed a marked, but regular, variation in TRR over the two-year observation period. Nerve section was shown to be associated with an increase in TRR in five ponies. The Hobday operation decreased TRR in one animal and had no marked effect in the second. The tie-back operation was associated with a decreased TRR in one pony and an increase in the second. Autopsies were carried out on all six operated ponies and measurements of TRR and lower respiratory resistance (LRR) were made immediately before the animals were killed. Evidence of regeneration of the recurrent laryngeal nerve was seen in one of the ponies which underwent the Hobday operation. Histological evidence of regeneration was found in another pony.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
Pulmonary mast cells (PMC) are important components of the inflammatory process in equine allergic lung diseases such as heaves. Very little, however, is known of the degranulation kinetics of these cells and thus, their pathophysiologic role remains largely speculative. The purpose of this study was to develop a repeatable protocol for in vitro equine PMC degranulation. Five mature horses (sex: 2 M, 3 F; age: 8.8 +/- 6.5 y), historically free of pulmonary disease and normal on clinical respiratory examination, arterial blood gas analysis, pulmonary mechanics testing and histamine inhalation challenge, were studied. Bronchoalveolar lavage was performed on 4 separate occasions, at least 2 d apart, in a different lung lobe on each occasion. The lavage fluid was concentrated by centrifugation. Cells were resuspended in modified HEPES/Tyrode, assessed for viability by Trypan blue exclusion, and PMC concentration determined. Cell inocula containing 30,000 PMC were incubated with 10(-8) to 6 x 10(-5) M A23187. Cells were then separated by centrifugation and histamine release (HR) was determined by fluorometric assay. The procedure was readily performed and yielded sufficient PMC for 30 to 60 inocula per lavage. Maximal HR (34.4 +/- 16.1%) was obtained with 10(-5) M A23187. The degranulation process was largely complete by 20 min but cell lysis was negligible. The challenge was repeatable within horse and produced a mean coefficient of variability of 23.0% following 20 min incubation with 10(-5) M A23187. We conclude that equine PMC degranulation can be repeatably performed in vitro and speculate that this protocol may be useful in further studies on the pathophysiology and treatment of equine allergic lung diseases.  相似文献   

10.
A thorough examination of the cardiovascular system is an integral part of a physical examination in the horse. The normal equine cardiovascular parameters are discussed, with an emphasis on auscultatory findings. The availability and application of other diagnostic techniques are discussed based upon findings of the physical examination.  相似文献   

11.
OBJECTIVES: To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An LC-DCP (8-hole, 4.5 mm) was applied to the dorsal surface of 1 randomly selected bone from each pair. One DCP (8-hole, 4.5 mm broad) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: The mean 4-point bending yield load, yield bending moment, composite rigidity, failure load, and failure bending moment of LC-DCP fixation were significantly greater (P<.01) than those of broad DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.001) greater for broad DCP fixation compared with broad LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion was significantly (P<.02) greater for broad LC-DCP fixation compared with broad DCP fixation. CONCLUSION: Broad LC-DCP offers increased stability in static overload testing, however, it offers significantly less stability in cyclic fatigue testing. CLINICAL RELEVANCE: The clinical relevance of the cyclic fatigue data supports the conclusion that the broad DCP fixation is biomechanically superior to the broad LC-DCP fixation in osteotomized equine MC3 bones despite the results of the static overload testing.  相似文献   

12.
Objectives— To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3‐hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws (DCP‐TLS) inserted in lag fashion for equine proximal interphalangeal (PIP) joint arthrodesis. Study Design— Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Animal Population— Cadaveric adult equine forelimbs (n=18 pairs). Methods— For each forelimb pair, 1 PIP joint was stabilized with an ESP (8 hole, 4.5 mm) and 1 with an axial 3‐hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression with load applied under displacement control at a constant rate of 5 cm/s. Six construct pairs were tested for cyclic fatigue under axial compression with cyclic load (0–7.5 kN) applied at 6 Hz; cycles to failure were recorded. Six construct pairs were tested in single cycle to failure under torsional loading applied at a constant displacement rate (0.17 radians/s) until rotation of 0.87 radians occurred. Mean values for each fixation method were compared using a paired t‐test within each group with statistical significance set at P<.05. Results— Mean yield load, yield stiffness, and failure load for ESP fixation were significantly greater (for axial compression and torsion) than for DCP‐TLS fixation. Mean (± SD) values for the ESP and DCP‐TLS fixation techniques, respectively, in single cycle to failure under axial compression were: yield load 123.9 ± 8.96 and 28.5 ± 3.32 kN; stiffness, 13.11 ± 0.242 and 2.60 ± 0.17 kN/cm; and failure load, 144.4 ± 13.6 and 31.4 ± 3.8 kN. In single cycle to failure under torsion, mean (± SD) values for ESP and DCP‐TLS, respectively, were: stiffness 2,022 ± 26.2 and 107.9 ± 11.1 N m/rad; and failure load: 256.4 ± 39.2 and 87.1 ± 11.5 N m. Mean cycles to failure in axial compression of ESP fixation (622,529 ± 65,468) was significantly greater than DCP‐TLS (95,418 ± 11,037). Conclusion— ESP was superior to an axial 3‐hole narrow DCP with 2 abaxial transarticular screws inserted in lag fashion in resisting static overload forces and cyclic fatigue. Clinical Relevance— In vitro results support further evaluation of ESP for PIP joint arthrodesis in horses. Its specific design may provide increased stability without need for external coaptation support.  相似文献   

13.
A prosthesis, composed of a steel cable and stress-reducing washers, was developed to prevent failure of laryngoplasty, a common treatment for horses affected by recurrent laryngeal neuropathy. Laryngoplasties were performed on 15 cadaveric larynges using a polyester suture on one side and the cable prosthesis on the other. Each prosthesis was distracted at a displacement rate of 20 mm/s using a servohydraulic materials testing machine until laryngoplasty failed. Distraction force and actuator displacement were recorded and analysed. All 15 laryngoplasties performed with a suture failed at the muscular process at a mean +/- s.d. force of 55.8 +/- 13.1 N. Six laryngoplasties performed with the cable prosthesis failed at the muscular process at mean force 219.6 +/- 125.0 N. In the other 9, the arytenoid cartilage was avulsed from the larynx at mean force 206.4 +/- 75.3 N, and the cable then tore through the muscular process at mean force 357.0 +/- 32.0 N. The difference in force required to cause failure of laryngoplasty was significant (P<0.0001). Although the prosthesis resisted substantially higher forces than did the suture, the effects of the prosthesis in vivo must be evaluated.  相似文献   

14.
OBJECTIVE: To determine the mechanical properties of Equine Interlocking Nail (EIN; JD Wheat Veterinary Orthopedic Research Laboratory, University of California, Davis) stabilized osteotomized tibiae and compare these variables with estimated in vivo loads. STUDY DESIGN: In vitro biomechanical investigation. ANIMALS: Twelve adult equine cadaveric tibiae. SAMPLE POPULATION: EIN-stabilized tibiae were tested monotonically under compression, 3- and 4-point bending, and torsion. Mechanical properties were compared with estimated in vivo loads. RESULTS: EIN-tibial composite mean compressive yield load (11 kN) and bending moment (216 Nm) were greater than loads expected postoperatively in vivo; however, the mean torsional yield load (156 Nm) was less than that expected in vivo. CONCLUSIONS: EIN-stabilized tibiae had compressive and bending strengths greater than those expected to maintain stability during walking in adult horses. Torsional yield strength did not appear sufficient to provide stability during walking in vivo. CLINICAL RELEVANCE: The EIN is not a feasible method of fracture repair for adult equine tibial fractures at this time, because its mechanical properties appear inadequate to withstand the postoperative torsional loads encountered during walking. Because this method of fracture repair may offer biological advantages, further modification of an interlocking nail for adult horses appears warranted.  相似文献   

15.
16.
Objectives— To compare monotonic biomechanical properties and fatigue life of a 5.5 mm broad limited‐contact dynamic compression plate (5.5‐LC‐DCP) fixation with a 4.5 mm broad LC‐DCP (4.5‐LC‐DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. Study Design— In vitro biomechanical testing of paired cadaveric equine MC3 with a mid‐diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. Sample Population— Adult equine cadaveric MC3 bones (n=18 pair). Methods— MC3 were divided into 3 test groups (6 pairs each) for: (1) 4‐point bending single cycle to failure testing; (2) 4‐point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. The 8‐hole, 5.5 mm broad LC‐DCP (5.5‐LC‐DCP) was applied to the dorsal surface of 1 randomly selected bone from each pair. One 8‐hole, 4.5 mm broad LC‐DCP (4.5‐LC‐DCP) was applied dorsally to the contralateral bone from each pair. Plates and screws were applied using standard ASIF techniques. All MC3 bones had mid‐diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t–test within each group. Significance was set at P<.05. Results— Mean yield load, yield bending moment, composite rigidity, failure load and failure bending moment under 4‐point bending, single cycle to failure, of the 5.5‐LC‐DCP fixation were significantly greater (P<.024) than those of the 4.5‐LC‐DCP fixation. Mean cycles to failure for 4‐point bending was significantly (P<.05) greater for the 4.5‐LC‐DCP fixation compared with the 5.5‐LC‐DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion for the 5.5‐LC‐DCP fixation was not significantly different (P>.05) than those with the 4.5‐LC‐DCP fixation. Conclusion— 5.5‐LC‐DCP fixation was superior to 4.5‐LC‐DCP fixation in resisting the static overload forces under palmarodorsal 4‐point bending. There was no significant difference between 5.5‐LC‐DCP fixation and 4.5‐LC‐DCP fixation in resisting static overload forces under torsion; however, the 5.5‐LC‐DCP offers significantly less stability (80% of that of the 4.5‐LC‐DCP) in cyclic fatigue testing. Clinical Relevance— The results of this in vitro study may provide information to aid in the selection of a biological plate for long bone fracture repair in horses.  相似文献   

17.
After laryngeal surgery, cranial glottic stenosis secondary to laryngeal web formation was diagnosed as the cause of upper airway obstruction in 4 dogs. Initial treatment of 3 dogs by peroral laryngeal web excision resulted in rapid recurrence of clinical signs. Subsequently, these 3 and the fourth dog were treated by scar excision, mucosal flap coverage, and placement of a silicone intraluminal laryngeal stent for 14 days. By 5 months (average) after surgery, on the basis of clinical evaluation of exercise intolerance, respiratory distress, and stridor, all dogs had alleviation of upper airway obstruction.  相似文献   

18.
An in vitro assay involving the use of a horse strongyle (Strongylus edentatus) and the micromotility meter has been developed to test for equine anthelmintic activity. Three commercially available equine anthelmintics (dichlorvos, ivermectin, and pyrantel pamoate) and an investigational drug (p-toluoyl chloride phenylhydrazone) were evaluated in this assay at four concentrations. After a 24-h incubation, greater than or equal to 10 micrograms/ml of all four drug treatments significantly (P less than or equal to 0.05) reduced the motility of ensheathed L-3 S. edentatus larvae, thereby indicating anthelmintic activity. Pyrantel pamoate also reduced motility at 1 microgram/ml, while the hydrazone significantly increased movement at this level. At 0.1 microgram/ml, none of the treatments significantly reduced motility; one treatment (dichlorvos) significantly increased larval motility. Incubation for 48 h resulted in significant activity (reduction in motility) at greater than or equal to 1 microgram/ml with two drugs (ivermectin, pyrantel pamoate); dichlorvos and the hydrazone reduced motility at greater than or equal to 10 micrograms/ml. None of the treatments significantly reduced motility at the lowest concentration (0.1 microgram/ml); however, at 48 h, two treatments (dichlorvos, hydrazone) significantly increased motility at the lowest concentration (0.1 microgram/ml). The in vitro S. edentatus motility assay proved to be sensitive, accurate and rapid. This assay system should be a valuable addition to tests used to identify potential equine anthelmintics, monitor helminth resistance to drugs, and perhaps define the kinetics and mode of action for drugs.  相似文献   

19.
20.
Reasons for performing study: One of the causes of equine laminitis is hyperinsulinaemia, which may be associated with endothelial dysfunction and insulin resistance of vessels. Hypothesis and objectives: Insulin resistance can be induced in palmar digital vessels by continued exposure to insulin in vitro. The objective was to evaluate this in vitro model for future studies. Methods: Palmar digital vessel segments were collected immediately after euthanasia from horses with normal insulin/glucose blood values. Four arterial and 4 venous rings (3 mm wide) were prepared and each ring mounted in a tissue bath, containing Tyrode's solution at 37°C, 2 g tension was applied and the rings allowed to equilibrate for 45 min. Of the 4 rings of each vessel type, one was used as a control. One each of the remaining 3 rings was used for incubation with insulin (to induce resistance), wortmannin (to block PI3‐kinase) and PD‐098059 (to block MAP‐kinase), respectively, for 30 min. After the incubation period, the rings were contracted with phenylephrine. When the response reached a plateau, a single dose of insulin was added to the baths and the response of each ring monitored for 30 min. Results: Insulin relaxed the control rings and those treated with PD 098059 but contracted those pretreated with insulin and wortmannin. Normal relaxation responses of the rings were converted to contractions by insulin resistance. Insulin resistance was confirmed by the qualitative response of insulin‐incubated and wortmannin‐incubated rings. Conclusions: This study demonstrated successful induction of insulin resistance in both arterial and venous rings. It also suggested that the MAP‐kinase pathway plays a minor role in controlling vasomotor tone under normal physiological conditions. Potential relevance: The study suggests that the induction of insulin resistance in equine palmar digital vessel rings is reliable and provides a good in vitro model for studying the vascular insulin resistance which may occur in equine laminitis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号