首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A gas chromatographic-electron capture detection method for determining the concentration of polychlorinated biphenyls (PCBs) as Aroclor 1254 (AR 1254) in serum was evaluated through a 2-phase collaborative study. In Phase I, each collaborator's lot of Woelm silica gel (70-150 mesh) was evaluated for elution and recovery of AR 1254, which had been added in vitro at 25 ng/mL to a serum extract. In Phase II, each collaborator analyzed a series of bovine serum samples that contained the following: (1) in vitro-spiked AR 1254; (2) in vivo AR 1254 and 8 in vitro-spiked chlorinated hydrocarbons; (3) in vivo AR 1254 only; (4) 8 in vitro-spiked chlorinated hydrocarbons only; and (5) neither AR 1254 nor chlorinated hydrocarbons above the detection limit of the method. In Phase I, the average recovery of AR 1254 from silica gel for the 6 collaborators was 87.9 +/- 15.44% (mean +/- 1 SD; N = 18; range = 52.3-105.8%). In Phase II, the analysis of in vitro spikes of AR 1254 in serum at 8.58, 16.8, 41.8, and 84.3 ppb gave mean (means) interlaboratory recoveries of 89.0, 83.3, 79.4, and 76.9%, respectively, with within-laboratory (repeatability) relative standard deviations (RSDr) of 18.8, 20.5, 10.2, and 14.1%, respectively, and among-laboratory (reproducibility) relative standard deviations (RSDR) of 21.5, 21.1, 14.6, and 20.8%, respectively. The determination of in vivo AR 1254 in samples containing approximately 10, 25, 50, and 100 ng/mL of AR 1254 resulted in interlaboratory means of 10, 22, 39, and 79 ng/mL, respectively, with RSDr = 6.7, 9.7, 6.4, and 5.8%, respectively, and RSDR = 20.6, 16.0, 10.9, and 10.3%, respectively. The precision of the method for incurred AR 1254 showed a maximum RSDr of less than 10% and a maximum RSDR of less than 21% for a concentration range of 10-100 ng/mL. The accuracy of the method as demonstrated by the mean recovery of in vitro-spiked AR 1254 over a concentration range of 8.58-843 ng/mL was 82.2%. The method has been approved interim official first action.  相似文献   

2.
An AOAC/IUPAC (International Union of Pure and Applied Chemistry) collaborative study was conducted to evaluate the effectiveness of an immunoaffinity column for the determination of aflatoxin. The test portion is extracted with methanol-water (7 + 3), filtered, diluted to less than 30% methanol with water, and applied to the affinity column. The column is washed with water and the concentrated aflatoxins are eluted with methanol. Total aflatoxins are determined by solution fluorometry with bromine (SFB), and individual toxins are determined by reverse-phase liquid chromatography with postcolumn derivatization with iodine (PCD). Corn naturally contaminated with aflatoxins, and peanuts, peanut butter, and corn containing added aflatoxins (B1:B2:G1:G2 = 7:1:3:1) were sent to 24 collaborators in the United States, France, Canada, and the Republic of South Africa. Twelve collaborators used the SFB method, 9 used the PCD method, and 3 used both SFB and PCD methods. Twenty collaborators completed the study (10 used the SFB method, 7 used the PCD method, and 3 used both SFB and PCD methods). Test portions were spiked at 10, 20, and 30 ng/g. For SFB analyses, recoveries of total aflatoxins were 123, 105, and 107%, respectively; the relative standard deviation for repeatability (RSDr) ranged from 11.75 to 16.57%, and the relative standard deviation for reproducibility (RSDR) ranged from 10.97 to 33.09%. For PCD analyses, recoveries were 81, 81, and 83%, respectively; the RSDr ranged from 5.20 to 17.22%, and the RSDR ranged from 4.68 to 50.77%. The RSDr for aflatoxins B1 and G1 for spiked test portions ranged from 5.45 to 23.55%, and the RSDR ranged from 4.21 to 57.28%.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
A method for determining serum zinc concentrations was collaboratively studied by 9 laboratories. Serum samples in polypropylene tubes are directly diluted with 0.03% Brij 35, and zinc is determined by flame atomic absorption spectrophotometry (AAS). A certified standard reference material serves as an external control. Repeatability relative standard deviations (RSDr) were 1.2 and 11.4% and reproducibility relative standard deviations (RSDR) were 6.1 and 12.9% for serum zinc concentrations of 6.36 and 0.63 micrograms/mL, respectively. The method has been approved interim official first action by AOAC.  相似文献   

4.
Ten collaborating laboratories assayed 4 blind duplicate pairs of whole bovine blood for cholinesterase activity. The 4 sample pairs ranged from normal (100%) to severely organo-phosphorus-inhibited (less than 10%) activity. Collaborators also received commercially available human lyophillized serum as an external control and a chromate solution to evaluate spectrophotometer performance. The Ellman kinetic assay was performed on a 1:1000 dilution of the whole blood in pH 8.0 phosphate buffer. The method monitors the increase in absorbance at 412 nm caused by formation of 5-thio-2-nitrobenzoic acid (yellow reaction product). Repeatability standard deviations (RSDr) ranged from 4.30 to 14.2%; reproducibility standard deviations (RSDR) ranged from 6.99 to 19.3%. The lower limit of detection was estimated to be 0.10 mumole/mL/min. The method has been approved interim official first action by AOAC.  相似文献   

5.
A liquid chromatographic method for determination of thiabendazole, 5-hydroxythiabendazole, oxfendazole, mebendazole (MBZ), and fenbendazole (FBZ) in cattle liver and muscle was collaboratively studied in 7 laboratories in 1986. For blind fortified samples containing 800 ppb FBZ, average recovery and relative standard deviations for repeatability and reproducibility (RSDr and RSDR) based on results from 6 of the participating laboratories were 83%, 12.7%, and 14.0%, respectively. Recoveries of FBZ from incurred liver samples were more variable. Recoveries of MBZ from livers fortified at the 100 ppb level were encouraging; however, the drug levels were too low in the incurred samples used for MBZ studies. Except for FBZ and MBZ in liver, the study data were not satisfactory. The method has been adopted official first action by AOAC for determination of 800-1600 ppb fenbendazole in liver. The analysis should be repeated using a smaller sample size when initial analyses show levels greater than 1600 ppb FBZ.  相似文献   

6.
A liquid chromatographic (LC) method for the determination of pentaerythritol tetranitrate (PETN) in pharmaceutical formulations and the bulk drug triturate was evaluated in an interlaboratory study that included 12 participating laboratories. The procedure involves extraction of the active ingredient with mobile phase, followed by filtration of the extract and reverse-phase liquid chromatography using an octadecylsiliane bonded phase column and UV detection at 230 nm. The mobile phase composition is 35% water in acetonitrile (v/v). Three bulk drug samples (20, 20, and 35% PETN), 2 commercial tablet formulations (20 and 80 mg PETN/tablet), and 1 commercial capsule formulation (45 mg PETN/capsule) were analyzed in duplicate by the proposed method. Repeatability (sr, RSDr) and reproducibility (SR, RSDR) based on peak height measurement for these samples ranged from 0.0066 to 0.1806 (0.53-3.36%) and 0.0165 to 0.2075 (0.76-3.86%), respectively. Results for peak area measurements ranged from 0.0145 to 0.2011 (0.93-3.74%) and 0.0231 to 0.2091 (1.28-3.89%), respectively. The method has been approved interim official first action by AOAC.  相似文献   

7.
The available collaborative studies for standard methods of analysis for various constituents of milk and milk products were examined in an attempt to assign specific repeatability and reproducibility precision parameters to these methods. The different collaborative assays for the primary constituents (moisture/solids, fat, protein), the nutritionally important elements (calcium, sodium, potassium, phosphorus), and miscellaneous analytes/physical constants (ash, lactose, salt, freezing point) produced different estimates of the precision parameters for the same method. A suitable summary of the precision estimates from collaborative studies is given by the reproducibility relative standard deviation, RSDg, which is relatively constant within a product and permits comparisons across products. An estimate of the variation of RSDR for an analyte from a number of collaborative studies is presented in terms of the median and 90% interval (the range of the centermost 90% of values). These estimates are only informative when a substantial number of independent studies are available for pooling the independent estimates to form a distribution of RSDR values. The RSDR for the determination of the primary constituents of milk and milk products is characterized by a median RSDR of 1% and a 90% interval of 0.3-3%, with RSDR estimates occasionally occurring below 0.3% and above 4%. These overall estimates appear to be independent of analyte, matrix, and method and apply to concentrations of primary constituents that range from about 2 to 80%. The repeatability relative standard deviation, RSDr, is unstable, although it tends to converge to about 0.5-0.7 X RSDR. Too few collaborative assays are available to characterize RSDR for the determination of certain other constituents (acidity, ash, lactose, salt, and the nutritionally important elements) unless RSDR values for different analytes, methods, and matrixes are pooled on the basis of similar analyte concentrations. When pooled, the RSDR values are generally better than predicted from the Horwitz equation, RSDR (%) = 2 exp (1-0.5 log10C), where C is the concentration expressed as a decimal fraction; all but one of 661 RSDR values are within the upper empirical limit of twice this curve.  相似文献   

8.
Seven laboratories participated in a collaborative study of a method for determination of phosphorus in meat and meat products. Samples are digested in sulfuric acid and hydrogen peroxide; digestion is complete in approximately 10 min. Phosphorus is determined by colorimetric analysis of a dilute aliquot of the sample digest. The collaborators analyzed 3 sets of blind duplicate samples from each of 6 classes of meat (U.S. Department of Agriculture classifications): smoked ham, water-added ham, canned ham, pork sausage, cooked sausage, and hamburger. The calibration curve was linear over the range of standard solutions prepared (phosphorus levels from 0.05 to 1.00%); levels in the collaborative study samples ranged from 0.10 to 0.30%. Standard deviations for repeatability (sr) and reproducibility (SR) ranged from 0.004 to 0.012 and 0.007 to 0.014, respectively. Corresponding relative standard deviations (RSDr and RSDR, respectively) ranged from 1.70 to 7.28% and 3.50 to 9.87%. Six laboratories analyzed samples by both the proposed method and AOAC method 24.016 (14th Ed.). One laboratory reported results by the proposed method only. Statistical evaluations indicated no significant difference between the 2 methods. The method has been adopted official first action by AOAC.  相似文献   

9.
A collaborative study was carried out on a solid-phase extraction method for separating volatile N-nitrosamines, particularly N-nitrosodimethylamine (NDMA), from combination minced fish or surimi-meat frankfurters with detection by gas chromatography-chemiluminescence (thermal energy analyzer). The results from the 10 collaborators were evaluated using the most recent AOAC guidelines for determining outliers and for the analysis of variance. For NDMA, repeatability standard deviations, sr, ranged from 0.56 to 2.25; repeatability relative standard deviations, RSDr, ranged from 8.9 to 11.5%. Reproducibility standard deviations, SR, for NDMA ranged from 1.40 to 6.49, and reproducibility relative standard deviations, RSDR, ranged from 24.2 to 28.9%. Our data compared favorably to the reproducibility (RSDR) curve of Horwitz. The method has been adopted official first action by AOAC.  相似文献   

10.
Two methods for the determination of dichlorvos in durum wheat by electrochemical assay and gas chromatography, respectively, have been developed. Dichlorvos, an organophosphorus anticholinesterase pesticide, was extracted from wheat with hexane, and the filtered extract was directly analyzed by gas chromatography with nitrogen-phosphorus flame detection (NPD). Recoveries of dichlorvos from milled wheat spiked at 0.25-1.5 microg/g ranged from 96.5 to 100.9%, and the limit of detection was 0.02 microg/g. The electrochemical assay was based on the detection of choline, the acetylcholinesterase product, via a choline oxidase biosensor. An aliquot of the filtered hexane extract was partitioned with phosphate buffer solution, and the organic layer was evaporated prior to electrochemical analysis. A limit of detection of 0.05 microg/g of dichlorvos was obtained with mean recoveries of 97-103% at spiking levels of 0.25-1.5 microg/g. A good correlation (r = 0.9919) was found between the results obtained with the electrochemical and those obtained with the gas chromatographic methods. The electrochemical method was peer-validated in two laboratories that analyzed 10 blind samples (5 duplicates), including a blank and 4 spiked samples with dichlorvos at levels of 0.25, 0.60, 1.00, and 1.50 microg/g. Within-laboratory repeatability (RSDr) and between-laboratory reproducibility (RSDR) ranged from 5.5 to 7.8% and from 9.9 to 17.6%, respectively.  相似文献   

11.
Each of 9 laboratories analyzed 9 pairs of blind duplicate raw milk samples for fat, using the Mojonnier ether extraction method (16.E13-16.E17), and for total solids, using a new direct forced air oven method. Solids-not-fat was determined by subtracting percent fat from percent total solids. The solids-not-fat content of the samples tested in the collaborative study ranged from 8.48 to 9.36%. The average repeatability standard deviation (sr) and the average reproducibility standard deviation (SR) for the solids-not-fat method were 0.019 and 0.041, respectively. Average repeatability (RSDr) and reproducibility (RSDR) relative standard deviations were 0.218 and 0.466%, respectively. The mean repeatability value (r) was 0.055; the mean reproducibility value (R) was 0.117. The difference between milk total solids determined by direct forced air oven drying and milk fat determined by Mojonnier ether extraction has been approved for interim official first action for determination of solids-not-fat content of milk.  相似文献   

12.
A joint AOAC/IUPAC (International Union of Pure and Applied Chemistry) interlaboratory study of an enzyme-linked immunosorbent screening assay (ELISA) for aflatoxins was conducted in laboratories in Canada, France, Japan, The Netherlands, Switzerland, Tunisia, and the United States. Twelve raw and roasted peanut and corn portions containing various concentrations of natural aflatoxins and supplemented when appropriate with aflatoxin B1 were distributed to participating laboratories for testing. The assay is based on competition between an enzyme-conjugated aflatoxin B1 and (free) aflatoxins in the test sample for aflatoxin-specific antibodies coated onto interior surfaces of microtiter wells. After a wash step to remove all unbound aflatoxins, a substrate added to each well is catalyzed from a colorless to a blue solution by any bound enzyme-conjugated aflatoxin B1 present. The intensity of the color decreases as the amount of free aflatoxin B1 in the test portion increases. Final determination of aflatoxin concentrations can be made by either visual comparison with standard solutions or spectrophotometric comparisons (at 650 nm) to knowns. Overall correlation was good between ELISA and thin-layer chromatographic results for corn and roasted peanut products, with 93 and 98% correct responses for visual and instrumental determinations, respectively. For instrumental determinations of aflatoxin in corn and roasted peanuts in the less than or equal to 20 ng/g range, the relative standard deviations for repeatability (RSDr) were 14.9 and 41.4%, respectively, and the relative standard deviations for reproducibility (RSDR) were 45.7 and 43.5%, respectively. For instrumental determination of greater than 20 ng/g, the respective RSDr and RSDR values were 19.4 and 52.7% for corn and 23.3 and 23.3% for roasted peanuts.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

13.
An inductively coupled plasma spectrometric method is described for the determination of 4 elements (Ca, B, P, and Mg) in calcium borogluconate veterinary medicines. Samples are diluted, acidified, and sprayed directly into the plasma. Reproducibility relative confidence intervals for a single sample assay are +/- 1.4% (calcium), +/- 1.8% (boron), +/- 2.6% (phosphorus), and +/- 1.4% (magnesium). The total element concentrations for each of 4 elements compared favorably with concentrations determined by alternative methods. Formulation estimates of levels of calcium gluconate, boric acid, phosphorus, and magnesium salts can be made from the analytical data.  相似文献   

14.
Grain amaranth (Amaranthus spp.) is a widely adaptable C4 pseudo-cereal crop that has interesting nutritional characteristics including high protein and calcium concentrations and a lack of gluten. To date, no antinutrient has been found at problematic levels in grain amaranth; however, oxalate has not been thoroughly studied. Dietary oxalate is a potential risk factor for kidney stone development, and its presence in food lowers calcium and magnesium availability. Oxalate concentration and forms and calcium and magnesium concentrations were determined in 30 field-grown grain amaranth genotypes from the species A. cruentus, A. hybrid, and A. hypochondriacus. The effects of seeding date and fertilization with calcium ammonium nitrate were evaluated in field experiments conducted in multiple environments; the effects of cooking were also evaluated. Mean total oxalate concentration in the 30 genotypes analyzed was 229 mg/100 g, with values ranging between 178 and 278 mg/100 g, the greatest proportion being insoluble (average of 80%). Calcium concentration averaged 186 mg/100 g and ranged between 134 and 370 mg/100 g, whereas magnesium averaged 280 mg/100 g and ranged between 230 and 387 mg/100 g. Fertilization only marginally increased total oxalate concentration and had no effects on other variables. Seeding date had no effects on any of the variables studied. Boiling increased the proportion of soluble oxalate but did not affect total oxalate concentration. Grain amaranth can be considered a high oxalate source, however, as most is in insoluble form, and due to its high calcium and magnesium concentrations, oxalate absorbability could be low. This should be confirmed by bioavailability studies.  相似文献   

15.
The suitability of a one-step derivatization procedure using N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide for the simultaneous assay of 22 free amino acids and its application for their analysis in six animal source foods (pork, dry cured ham, chicken stock, fresh cheese, ripened cheese, and dry salted sardine) by GC-MS were studied. All 22 free amino acid derivatives were correctly detected and resolved. Reproducibility (%RSD) of the method was in the range of 1.9-12.2%. Detection and quantitation limits of the analytical procedure ranged from 0.01 to 0.46 mg/100 g dry weight and from 0.02 to 1.55 mg/100 g dry weight, respectively. The calibration curves were linear within the range 0.1-15.0 mg/100 g with correlation coefficient values (R(2)) from 0.9891 to 0.9983. All analyzed food products showed free amino acid contents similar to those found in the scientific literature. The proposed GC-MS method for the determination of free amino acids in animal source food can be used in routine for both analytical and research purposes.  相似文献   

16.
Eleven laboratories participated in an interlaboratory study of an enzyme-linked immunoassay for limonin in grapefruit juice. Participating laboratories received training and practice samples until familiar with the procedure. Laboratories then received 8 sample pairs of grapefruit juice as blind duplicates. Samples were refrigerated and analyzed within 4 days of receipt. Results from 1 laboratory and 6 individual samples were excluded from the statistical analysis. Method performance was measured by the one-way component of variance analysis. Repeatability relative standard deviations (RSDr) ranged from 7.0 to 15.6%. Reproducibility relative standard deviations (RSDR) ranged from 12.9 to 29.4%.  相似文献   

17.
An enzymatic method for the determination of free glutamic acid in meat products and dried soups was collaboratively studied in 11 laboratories. In the presence of the enzyme glutamate dehydrogenase, L-glutamic acid is oxidatively deaminated by nicotinamide adenine dinucleotide (NAD) to 2-oxoglutarate. In a reaction catalyzed by diaphorase, the NADH thus formed converts 2-(p-iodophenyl)-3-(p-nitrophenyl)-5-phenyltetrazolium chloride to a formazan, which is measured in the visible range at 492 nm. Fourteen samples (7 samples of minced sausage and 7 samples of dried cauliflower soup) with glutamate contents varying between 0.4 and 16 g/kg were included in the study. Materials were distributed to participants as blind duplicates and as split level pairs. The mean relative standard deviation (RSDR) for reproducibility for the dried soup material containing glutamate between 7 and 16 g/kg was 4.6%. RSDR values for samples of minced sausage containing glutamate at lower levels (0.4-1.3 g/kg) were between 12 and 16%.  相似文献   

18.
青鳞鱼骨粉的食用营养价值及应用研究   总被引:7,自引:1,他引:7  
研究了青鳞鱼骨粉的食用营养价值及其在玉米粥、马蹄粉和鸡精中的应用。结果表明:(1)青鳞鱼骨粉是一种蛋白质含量为27.0%、脂肪含量为2.0%的典型的高营养低热能食品;它具有独特的补钙生物学功能的关键因素和优势。(2)青鳞鱼鱼骨粉钙磷比为2.32∶1,钙和铁易于被人体吸收和利用。(3)青鳞鱼骨粉氨基酸总量为24.36 mg/100g,其中必需氨基酸为5.23 mg/100g,占氨基酸总量的21.49%;蛋白质质量优越于猪骨粉,具有更大的利用价值。(4)以10%的比例将超微鱼骨粉分别添加到策友牌玉米粥,互润牌桂花马蹄粉和美极牌鲜鸡精中,可以提高产品的感官质量,达到强化蛋白质和钙磷铁等矿物质元素、改善食品的钙磷比例等目的。  相似文献   

19.
A previously developed method that uses a simplified sample preparation and fluorometric detection of liquid chromatographic eluates for the determination of oxolinic acid in salmon muscle has been collaboratively studied. Five laboratories participated in the study to analyze, in quintuplicate, blank salmon muscle fortified at 10, 20, 50, and 100 micrograms/kg (ppb), and 2 incurred samples from salmon given feed with medicated oxolinic acid. The tissue, 2 g mixed with 2 g Na2SO4, is extracted with ethyl acetate and centrifuged, and the solvent is evaporated. The residue is partitioned in a mixture of hexane and 0.01 M oxalic acid, and the aqueous phase is chromatographed using fluorescence detection at 327 nm excitation and 369 nm emission. Mean recoveries ranged from 77.2 to 84.5% in spiked samples with reproducibility relative standard deviation (RSDR) ranging from 11.5 to 18.3%. Treated salmon were found to contain 8.71 and 53.8 micrograms/kg with RSDR of 18.6 and 16.7%, respectively. The corresponding repeatability relative standard deviations (RSDR) were 5.8-12.2%, and 7.7 and 6.2%. The method is recommended for regulatory purposes in Canada.  相似文献   

20.
A collaborative study of a liquid chromatographic method for the determination of aflatoxins B1, B2, G1, and G2 was conducted in laboratories located in the United States, Canada, South Africa, and Switzerland. Twenty-one artificially contaminated raw peanuts, peanut butter, and corn samples containing varying amounts of aflatoxins B1, B2, G1, and G2 were distributed to participating laboratories. The test portion was extracted with methanol-0.1N HCl (4 + 1), filtered, defatted with hexane, and then partitioned with methylene chloride. The concentrated extract was passed through a silica gel column. Aflatoxins B1 and G1 were derivatized with trifluoroacetic acid, and the individual aflatoxins were determined by reverse-phase liquid chromatography with fluorescence detection. Statistical analysis of the data was performed to determine or confirm outliers, and to compute repeatability and reproducibility of the method. For corn, relative standard deviations for repeatability (RSDr) for aflatoxin B1 ranged from 27.2 to 8.3% for contamination levels from 5 through 50 ng/g. For raw peanuts and peanut butter, RSDr values for aflatoxin B1 were 35.0 to 41.2% and 11.2 to 19.1%, respectively, for contamination levels from 5 through 25 ng/g. RSDr values for aflatoxins B2, G1, and G2 were similar. Relative standard deviations for reproducibility (RSDr) for aflatoxin B1 ranged from 15.8 to 38.4%, 24.4 to 33.4%, and 43.9 to 54.0% for corn, peanut butter, and raw peanuts, respectively. The method has been adopted official first action for the determination of aflatoxins B1, B2, G1, and G2 in peanut butter and corn at concentrations greater than or equal to 13 ng total aflatoxins/g.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏