首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An enzyme-linked immunosorbent assay (ELISA) was developed to detect the humoral antibody response in chickens receiving subcutaneous injections of the CU vaccine strain of Pasteurella multocida. Serum samples were collected twice weekly for 3 weeks, and chicken antibody responses were monitored using ELISA. The positive/negative ratio method of analysis was used to determine the antibody titer of vaccinated chickens. After a loge transformation of the ELISA titer, a linear relationship was confirmed between ELISA titer and positive/negative ratio. Regression analysis was used to construct a standard curve and derive an equation from this relationship. Using this equation, only one dilution was needed to determine the antibody titer of any unknown serum sample. The ELISA technique was used to monitor the mean antibody titer of vaccinated chickens over the 3-week period. A classic primary response curve occurred when titer was plotted against time.  相似文献   

2.
A labeled avidin-biotin enzyme-linked immunosorbent assay (LAB-ELISA) for detecting antibody to infectious laryngotracheitis (ILT) virus in chicken sera was developed and compared with ordinary ELISA. Purified ILT virus, biotin-labeled anti-chicken IgG rabbit IgG conjugate, and horseradish-peroxidase-labeled avidin were used in the LAB-ELISA. When sera from farm chickens were tested by serum neutralization (SN) and two kinds of ELISA, the correlation rate between SN and LAB-ELISA was 50/50 (100%), and that between SN and ordinary ELISA was 39/50 (78%). In LAB-ELISA, all of the sera that were antibody-negative by SN had low absorbance (A) values (below 0.05), and the A values were closely correlated with the SN indexes. In ordinary ELISA, however, the sera antibody-negative by SN had various A values ranging from 0.06 to 0.32. LAB-ELISA had much lower nonspecific reactions than ordinary ELISA against sera from ILT-negative chickens, even when chickens were 30 weeks old. ILT antibody production after ILT vaccination could be detected by LAB-ELISA. A values peaked 5 weeks postinoculation and were maintained for 17 weeks.  相似文献   

3.
An enzyme-linked immunosorbent assay (ELISA) was developed to measure antibodies to infectious bronchitis virus (IBV) in chickens. The results are reported in IBV standard ELISA values calculated by comparing antibody levels in test sera with antibody levels in a series of standard reference sera. The IBV standard ELISA values were good indicators of responses to vaccination and the immune status of experimentally challenged birds. Although the assay was not serotype-specific, the sensitivity makes it ideally suited for determining the immune status of poultry flocks. The assay results compared favorably with other laboratory results, including virus-neutralization titers, hemagglutination-inhibition levels in sera, virus isolation from vaccinated/challenged birds, and the tracheal ring test results.  相似文献   

4.
A 2-stage strategy was developed and evaluated for estimating serum antibody titer by use of ELISA and a series of dilutions. In stage 1, the linear response region and least-square estimate of the assay line slope were established from 9-point dilution assays. Provided that the reading was within the linear response region, this information was used in the stage-2 estimation of titer from a single absorbance reading. Operationally, 2 fixed dilutions were selected, one suitably low and one suitably high, to provide at least one reading within the linear region. The procedure should save considerable time when a large number of assays are to be performed. Stage 1 required approximately twenty 9-point assays, but all subsequent assays required only 2 fixed dilutions.  相似文献   

5.
6.
An indirect enzyme-linked immunosorbent assay (ELISA) was developed and tested for its ability to detect humoral response to Mycoplasma gallisepticum in chickens. Two antigens were used in the solid phase of the assay. Antigen 1 was a membrane-derived sodium dodecyl sulfate (SDS)-solubilized preparation; Antigen 2 was prepared in the same manner as Antigen 1 but was passed through an immunoadsorbent column containing rabbit anti-medium antibodies. Test conditions were optimized for incubation times and temperatures. Antigen, serum, and enzyme conjugate concentrations were standardized, and reproducibility was determined. A baseline value, representing a positive or negative result, was established independently for both antigens. The assay was then used to detect anti-M. gallisepticum antibodies in experimentally infected chickens. Serum samples collected at 0, 2, 5, 7, 10, 14, 21, 28, and 35 days postinfection (PI) were analyzed by serum plate agglutination (SPA), hemagglutination-inhibition (HI), and ELISA with both Antigens 1 and 2. ELISA was found to be less sensitive but more specific than SPA and more sensitive than HI. The ELISA was more sensitive with Antigen 1 than with Antigen 2. The former assay correctly identified 79% of the serum samples positive for M. gallisepticum by 7 days PI and 100% of the positive birds by 35 days PI. When the absorbance values for each group of birds were averaged, the ELISA successfully identified the M. gallisepticum-infected birds as uniformly positive 7 through 35 days PI and correctly identified all other groups negative for M. gallisepticum through 35 days PI.  相似文献   

7.
Nine thousand commercial breeder chicks (Chankee) reared in a floor pen were exposed to restricted numbers of Eimeria tenella and E. necatrix oocysts to confer immunity. Antibody induction in these chicks was examined by the enzyme-linked immunosorbent assay (ELISA) with antigen prepared from E. tenella oocysts. The oocyst excretion pattern demonstrated recycled infections which continued in these chicks for greater than or equal to 22 days after exposure. Antibody levels in their sera, as determined by the mean absorbence values in ELISA, increased gradually up to 38 days post-inoculation. Mean absorbence values of sera from control chicks remained at a low level. When infected and control chicks were challenged with the two species of coccidia, the test chicks were protected against both species. The antibody level did not change for 8 days in the challenge groups, while in the control chicks, absorbence in ELISA rose significantly and the mean absorbence value was higher than that in immunized chicks. Some factors which influence the results of ELISA are considered and the applicability of this method to measuring immunity against coccidiosis in chickens is discussed.  相似文献   

8.
An enzyme-linked immunosorbent assay (ELISA) was developed for detecting antibody to type A avian influenza (AI) virus. The sensitivity and group specificity of the AI-ELISA were compared with those of the agar-gel-precipitin test (AGPT) and the hemagglutination-inhibition (HI) test under conditions of both controlled and field exposure. During the course of temporal experimental infection (0-76 days) of specific-pathogen-free (SPF) chickens with AI subtype Hav9N2, the AI-ELISA was able to detect specific AI antibody as early as 8 days postinoculation (PI), and it measured rising levels of antibody through 35 days PI, at which time the chickens were re-exposed to AI virus. Conversely, AGP tests were negative through 35 days PI, and HI tests began to detect low levels of AI antibody only at 21 days PI. Following a secondary infection at 35 days PI with the same AI subtype, all tests measured rising levels of AI-specific antibody (35-76 days PI). However, the AGP test was positive at only the 7- and 14-day samplings postsecondary immunization. Under field conditions, the AI-ELISA was able to detect serum AI antibody in flocks from which highly pathogenic AI was isolated, but the AGP tests of these sera were negative.  相似文献   

9.
An enzyme-linked immunosorbent assay system (ELISA) was adapted for the detection of antibodies to avian adenovirus (AV) and avian adenovirus-associated virus (A-AV). Both before and after exposure, sera from chickens undergoing natural and experimental infections were assayed by ELISA, virus neutralization (VN), and immunodiffusion (ID) for antibody to both CELO virus and A-AV. The ELISA system was found to be comparable to VN for determining antibody concentrations to CELO virus and A-AV. In many cases, ELISA was found to be more sensitive than ID.  相似文献   

10.
An enzyme-linked immunosorbent assay (ELISA) was adapted to test serum antibody to enterotoxin of Clostridium perfringens type A. The test was evaluated using sheep, calf and guinea pig sera and compared with passive hemagglutination and immunodiffusion tests. The ELISA was found to be more sensitive than the other two tests and was completely free from nonspecific reactions. The method was considered to be technically advantageous and suitable for semiautomated procedures.  相似文献   

11.
Canine hepatozoonosis is a tick-borne protozoal disease caused in the Old World and South America by Hepatozoon canis. An enzyme-linked immunosorbent assay (ELISA) using purified H. canis gamont antigen was applied for the detection of antibodies reactive with H. canis. Evaluation of the ELISA with sera from naturally infected parasitemic dogs indicated that it was sensitive (86%), specific (97%), and comparable to the indirect fluorescent antibody test (IFAT) for the detection of H. canis antibodies. A variable degree of serologic cross-reactivity was found between sera from H. americanum-infected dogs and the H. canis antigen. Dogs experimentally infected with H. canis seroconverted 1-4 weeks post-infection (PI). Antibody levels peaked at 7-9 weeks PI and gradually declined thereafter remaining above the cut-off value until the conclusion of the study 7 months PI. The ELISA will be valuable for serological evaluation of dogs suspected of exposure to H. canis and for epidemiological studies.  相似文献   

12.
An indirect enzyme-linked immunosorbent assay (ELISA) was developed to measure humoral antibody responses of chickens against Pasteurella multocida. A standard indirect hemagglutination (IHA) test was used to compare serologic results with those of ELISA. The ELISA was also used following challenge with P. multocida to compare the efficacy of three commercial fowl cholera vaccination regimens. Although antibody titers measured by ELISA and IHA were highly correlated, ELISA was at least twice as sensitive as IHA. Antibody measured by ELISA and IHA also correlated significantly with protection against P. multocida challenge. No mortality occurred in any of the three vaccinated challenged groups. However, control unvaccinated chickens experimentally infected with P. multocida developed signs of acute pasteurellosis and died by the 10th day post-challenge. Impression smears made of hepatic tissue from all chickens were stained (Wright's stain), and typical bipolar rods characteristic of Pasteurella were identified in smears from unvaccinated challenged controls only.  相似文献   

13.
An enzyme-linked immunosorbent assay (ELISA) for the detection of antibody to avian encephalomyelitis virus (AEV) has been developed for determining whether existing AEV control programs adequately protect breeder hens. A partially purified AEV antigen was bound to microcuvettes for reaction with specific primary antibody. A second antibody, rabbit anti-chicken immunoglobulin G (IgG) conjugated with horseradish peroxidase, was employed to react with bound primary IgG. The relative amount of bound primary IgG was detected using ortho-phenylenediamine as a substrate for enzymatic production of a chromogen by horseradish peroxidase. Intensity of absorbance of the chromogen at 490 nm was related to the bound primary antibody by the titration method. Negative antisera were surveyed to establish an appropriate positive/negative cutoff level at twice the mean absorbance of negative sera at a 1:100 dilution. The test reagents for the ELISA were optimized by reagent titrations utilizing known positive and negative antisera for discrimination. The optimized ELISA had a coefficient of variation of from 1.2 to 3.3 for within-assay titer and of 2.4 for between-assay mean titer. Even though the ELISA detected only specific IgG, it was as accurate as the virus-neutralization test for evaluating the immune status of hens to AEV. Moreover, the ELISA was more economical in the use of reagents, time, and personnel and was free from dependence on susceptible embryos. Since ELISAs can be standardized and measured with manual or automated instruments, the derived ELISA can be easily and economically used to evaluate the immune status of breeder hens in commercial poultry operations.  相似文献   

14.
An enzyme-linked immunosorbent assay (MYCO-ELISA) was developed to detect antibodies to Mycoplasma gallisepticum (MG) in chicken sera. The assay was standardized in terms of optimum antigen concentration, serum dilution, conjugate dilution and incubation temperature, and time. The MYCO-ELISA antigen was prepared from MG whole bacterial cell or its disrupted cell suspension. Both preparations showed strong affinity for binding or adsorbing to the surface of polystyrene wells of the microtiter plate. The MYCO-ELISA was more sensitive than the hemagglutination-inhibition test. However, cross-reactions were observed with sera from M. synoviae (MS)-infected birds.  相似文献   

15.
An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibacterium salmoninarum in sockeye salmon (Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout (O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0-23%) and the mean interassay CV was 8.29% (range, 4-16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration (r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve (r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.  相似文献   

16.
An immuno-enzyme assay for measuring infectious bursal disease antibodies in chickens is described. The test is performed rapidly after coating plates overnight with partially purified antigen prepared in cell culture. Coated plates can be stored for at last 4 months. The chromatographically purified rabbit anti-chicken immunoglobulin-G, conjugated to horseradish peroxidase, was used optimally at a dilution of 1:3,000. It could be stored for at least 10 months without a reduction in titer. The test is safe, highly reproducible, specific, and sensitive. Results can be read visually or by spectrophotometry. Antibodies could be detected as early as 4 days postinfection. Serum titers rose rapidly to high levels, ranging from 1:1,600 to 1:25,600 by one week postinfection. High titers persisted for up to one year. The results of this assay compare favorably with results obtained with the agar-gel precipitin and virus-neutralization tests.  相似文献   

17.
To detect antibody against feline herpesvirus 1 (FHV-1) in the sera of cats, the sensitivity and specificity of an enzyme-linked immunosorbent assay (ELISA) using nuclear antigen was investigated. The standardized optical density readings (ODs) of the ELISA obtained by the 1-step serum dilution (1:80) method were compared with the serum neutralization test (SNT) results, with a correlation of 0.993, and with the hemagglutination inhibition (HI) test results, with a correlation of 0.851. The ODs for the ELISA titers were obtained using the serial serum dilution method and were compared with the SNT results, with a correlation of 0.933, and with the HI test results, with a correlation of 0.987. In the experimental infection of 4 specific-pathogen-free cats, the results of different serologic tests (SNT and HI) and the ELISA using the serial serum dilution method revealed rapid production of antibodies after inoculation, whereas the ELISA using the one-step serum dilution method indicated that titers increased more slowly. These results indicate that with the present ELISA using nuclear antigen, there are fewer demands on time and labor, making the method convenient for monitoring FHV-1 infection.  相似文献   

18.
A total of 2238 feline serum samples submitted to the New York State Diagnostic Laboratory over a 1-year period were tested for the presence of coronavirus antibodies, using the computer-assisted, kinetics-based enzyme-linked immunosorbent assay (KELA). Cats from which sera were obtained were categorized by sex, age, breed, and disease status, and variations in mean antibody titers for different sub-classifications within each category were analyzed by computerized statistical analysis. As expected, higher mean antibody titers were recorded for cats with feline infectious peritonitis, and for cats with a recent history of possible coronavirus exposure. However, an unexpected inverse relationship between coronavirus antibody titer and age was also found. Certain cattery-oriented pure breeds appeared to have higher mean antibody titers, because their sample populations contained a higher percentage of younger cats and cats of unknown age-groups which, over-all, had higher mean titers. Taken together, the data substantiated the efficacy of the computer-assisted KELA for routine detection of serum coronavirus antibodies in cats.  相似文献   

19.
A reproducible enzyme-linked immunosorbent assay (ELISA) using Marek's disease virus (MDV)-infected cells for the detection of antibodies to MDV is described. The optimum number of MDV-infected chicken embryo fibroblasts (CEF) was 5 X 10(4)/well, and test sera were positive at 1:400 dilutions. Compared with a purified virus preparation, MDV-infected CEF produced high specific and low nonspecific reactivities. Wells coated with whole cells could be stored at 4 C or -20 C for at least 3 months without loss of reactivity. With antibody-negative sera, the cutoff absorbency was 0.20 units. The ELISA was 20-to-40-fold more sensitive than indirect immunofluorescence. Homologous combinations of antisera in wells coated with CEF infected with different MDV serotypes were more reactive at higher dilutions than were heterologous combinations. The procedure described is specific and suitable for large-scale screening of both chicken and monoclonal antibodies against MDV.  相似文献   

20.
An enzyme-linked immunosorbent assay, using whole-cell and sonicated antigens prepared from Brucella ovis, Actinobacillus seminis, and Actinobacillus seminis-like cultures isolated from rams in Wyoming, was able to detect antibody to these antigens in rams with epididymitis. The whole-cell antigens used in this procedure gave lower background values, compared with those of the sonicated antigens. The procedure was able to detect antibody in rams before clinical signs of epididymitis became apparent.  相似文献   