首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Three serological assays were compared for detection of antibodies to bovine herpes-virus type 1. These were virus neutralization (VN), enhanced complement fixation (CF) and enzyme-linked immunosorbent assay (ELISA). The ELISA was developed using an infected cell lysate antigen and purified virus and was optimized in relation to antigen and antisera dilutions. The CF assay was enhanced by the addition of bovine complement. These 3 assays were compared for detection of: specific virus antibody titers; sero-conversions; early antibody response in experimentally-infected cattle. Both ELISA end-point titers and single dilution values were found to be more sensitive than the CF or VN assays for specific antibody level quantitation. With a single dilution ELISA test procedure a correlation was obtained between ELISA values and VN titers. Using the single dilution ELISA test the assay also detected antibodies in experimentally-infected cattle before either the VN or CF assays, and agreed with the VN test in 35/38 seroconversions found by 4-fold or more VN changes between acute and convalescent paired sera from naturally-infected animals. The single dilution ELISA was a rapid and sensitive test for routine antibody detection in bovine sera.  相似文献   

2.
The dot enzyme-linked immunosorbent assay (Dot-ELISA) and the enzyme-linked immunosorbent assay (ELISA) were compared with the immunofluorescent antibody test (IFA) for detection of IgM- and IgG-specific antibodies to human toxoplasmosis. Reciprocal titers were determined in all three assays using sera from 56 patients with suspected toxoplasmosis or with symptoms and diseases requiring exclusion of toxoplasmosis and control sera from 56 healthy persons. Using the Dot-ELISA, six patient sera (10.7%) were positive at titers of greater than equal to 1024 for IgM antibodies (titer range 1024-16 384) and 47 sera (84%) were positive for IgG antibodies (titer range 16-262 144) at a titer of greater than or equal to 16. One control serum was reactive for IgM (titer 1024) and 10 control sera (18%) were positive for IgG in the Dot-ELISA. In the ELISA, at titers of greater than or equal to 128, five sera (9%) were reactive for IgM (titer range 128-512) and 52 sera (92.8%) were reactive for IgG (titer range 32-8192) at a titer of greater than or equal to 32; no control sera gave positive reactions for IgM while 10 sera (18%) were positive for IgG in the ELISA. Using the IFA test at reciprocal titers of greater than or equal to 16, four sera (7.1%) were positive for IgM (titer range 32-512), and 51 sera (91%) were positive for IgG (titer range 16-8192). None was reactive for IgM, and eight sera (14%) were positive for IgG (titer range 32-128) in the IFA test. The Dot-ELISA correlated well with the IFA test (correlation coefficient = 0.895) and the ELISA correlated slightly higher with the IFA test (correlation coefficient = 0.910) for detection of IgG antibodies to Toxoplasma gondii.  相似文献   

3.
Caesarean-derived, colostrum-deprived swine were exposed to a broth culture of a low passage field isolate of Mycoplasma hyopneumoniae by intranasal inoculation. The intranasal-inoculated swine subsequently were commingled with their litter-mates to effect transmission via contact-exposure. Sera were collected from the swine at two to four week intervals for approximately one year postexposure and evaluated by the enzyme-linked immunosorbent assay (ELISA), indirect hemagglutination and complement fixation tests. The intranasal-exposed swine seroconverted earlier, developed higher titers and remained indirect hemagglutination and complement fixation positive longer than the contact-exposed swine. It was concluded that the antibody response of intranasal-exposed swine was artificially high and that sera from such swine were not suitable for evaluating the sensitivity of mycoplasmal pneumonia of swine serodiagnostic tests. The indirect hemagglutination test was relatively insensitive and technically cumbersome and the least promising as a practical field test. The complement fixation test appeared to be slightly more sensitive in detecting early antibody production (especially in contact-exposed swine) but it was the least sensitive in detecting late antibodies. The ELISA was generally the most sensitive procedure. Individual high ELISA titers were from ten to 32 times greater than maximum complement fixation and indirect hemagglutination titers. The most striking difference among the three tests was the persistence of high ELISA titers late in the study. All swine were ELISA positive at necropsy approximately one year postexposure despite the fact that lungs were devoid of lesions and culturally and immunofluorescent negative for M. hyopneumoniae.  相似文献   

4.
The sensitivity of an indirect enzyme-linked immunosorbent assay (ELISA) for bovine IgG serum antibody to Pasteurella haemolytica was compared with that of an indirect hemagglutination (IHA) test. Pasteurella haemolytica serotypes were grown in a chemically defined cell culture medium, and soluble antigens released into the growth medium were used in the ELISA and IHA test. An ELISA with serotype-1 antigen consistently detected antibody in sera that were positive by IHA test (correlation, 99%). Sera reacting with serotype-1 ELISA antigens also reacted with ELISA antigens prepared from other serotypes. Although ELISA titers averaged 5 log2 units higher than IHA titers, plots of titers determined by the 2 methods were approximately linear. Titer increases detected in paired serum samples by either test were similar. The ELISA was more sensitive than was the IHA in detecting colostral IgG antibody in serum of newborn calves. The ELISA uses a simple, stable antigen preparation and detects antibody to P haemolytica serotypes that commonly infect cattle.  相似文献   

5.
An enzyme-linked immunosorbent assay (ELISA) for the diagnosis of canine herpesvirus (CHV) infection using antigen prepared by solubilizing infected cells was developed. The ELISA and two improved methods of serum neutralization test, the microplate serum neutralization test (MSNT) with complement and the 50% plaque reduction (PR) assay with complement, were compared for the results of antibody detection from a total of 557 field canine sera. Of 529 sample sera that were negative in the MSNT with complement, 119 were ELISA positive, and this result together with time course of serum antibody detection in a dog experimentally infected with CHV strongly suggested that the MSNT with complement is less sensitive for the detection of antibody in CHV infected dogs, especially those in early stages of infection. A correlation was found between the titers measured by the ELISA and 50% PR assay with complement, however, for field use, the ELISA is recommended as a highly sensitive test method of serodiagnosis of CHV infection adequate for dealing with a large number of samples with less demand on time and effort.  相似文献   

6.
An enzyme-linked immunosorbent assay (ELISA) was developed for detection and quantification of serum antibodies to transmissible gastroenteritis virus (TGEV) in swine. Sera from pigs inoculated with cell culture-origin TGEV or gut-origin TGEV were tested for anti-TGEV antibody by ELISA and by serum virus-neutralization test (NT). The ELISA detected antibody 3 days (av) sooner than did the NT when sera from pigs inoculated with cell culture-origin TGEV were tested and 1 day sooner than did the NT when sera from pigs inoculated with gut-origin TGEV were tested. The ELISA appeared to be more sensitive than the NT, since ELISA was more responsive to low-level antibody and ELISA titers exceeded NT titers.  相似文献   

7.
An enzyme linked immunosorbent assay (ELISA) for the detection of antibody to bovine parainfluenza virus type 3 has been compared with the hemagglutination inhibition test on 130 field sera, and seven other paired sera showing a significant raise of titers. The ELISA was found to be four to 64 times more sensitive than the hemagglutination inhibition test and the two tests demonstrated a good correlation.  相似文献   

8.
Development of an enzyme-linked immunosorbent assay for Bordetella avium   总被引:1,自引:0,他引:1  
A Bordetella avium enzyme-linked immunosorbent assay (ELISA) was developed to detect serum antibodies in 1-day-old poults, experimentally infected turkeys, and naturally infected turkeys. The optimized procedure included use of a suspension of whole bacteria coated onto plastic microtiter plates, a 1:200 serum dilution, a 1:3200 dilution of commercially available goat anti-turkey IgG (heavy and light chain) conjugated with horseradish peroxidase, and 0.04% orthophenylenediamine as substrate. A sample/negative (S/N) ratio method of analysis was used to estimate antibody titer from absorbance values. The regression equation used to estimate antibody titers was derived from the testing of naturally infected turkey sera. The equation was derived by plotting the log10 titer of the sera against the S/N ratio at a 1:200 serum dilution. The ELISA was an effective method for detecting antibody to B. avium, and the procedure should prove useful for laboratories equipped for high-volume ELISA testing.  相似文献   

9.
A blocking enzyme-linked immunosorbent assay (ELISA) has been adapted to detect specific antibodies in bovine sera to respiratory syncytial virus using a horseradish peroxidase-labeled monoclonal antibody to the fusion protein of the virus. This assay plus an indirect blocking ELISA and indirect ELISA were used to detect antibodies to the bovine respiratory syncytial virus (BRSV) in 159 field-origin bovine sera. Results of these assays were compared with serum antibody titers measured by the serum neutralization (SN) test. Over a 56-day period, the mean neutralization titers and the mean delta absorbance values for the blocking ELISA, on the same sera, showed similar declines. However, the calculated correlation coefficients between mean SN titer and mean absorbance value for the blocking ELISA of the individual sera ranged from -0.2 to -0.5 depending on the source of sera. Similar values were obtained whether using crude or purified viral antigen in the assays. Corresponding calculated correlation coefficients were generally higher for the indirect blocking ELISA or indirect ELISA than for the blocking ELISA. The blocking ELISA was between 70 and 64% as sensitive as the serum neutralization test with a specificity of 100 or 90% using the crude and purified viral antigen, respectively. The indirect blocking ELISA and indirect ELISA had similar calculated sensitivities and specificities. The blocking ELISA was faster to run than either of the other ELISA's or the neutralization test. Further, nonspecific background absorbance was obviated because the blocking ELISA detects antibodies to 1 specific viral protein, the fusion protein. These studies suggest that the blocking ELISA should be useful as a serological test for BRSV antibodies.  相似文献   

10.
An enzyme-linked immunosorbent assay (ELISA) was evaluated and compared in parallel with the standard complement fixation test (CFT) for the diagnosis of bovine subclinical paratuberculosis. Bovine sera preabsorbed with the mixture of Mycobacterium phlei and kaolin suspension were assayed for antibody activities to the crude protoplasmic antigen of Mycobacterium paratuberculosis in the ELISA. ELISA antibody titer was expressed as ELISA antibody index (EAI) value: EAI = (At-An)/(Ap-An), where At, Ap and An are the absorbance values of a 1:200 dilution of unknown test sera, a 1:400 dilution of positive control serum, and a 1:200 dilution of negative control serum. An EAI of 0.6 or greater was established as a reasonable cutoff point for a positive antibody titer by ELISA. Of the 156 sera from cattle with subclinical M. paratuberculosis-infection, 106 (67.9%) were positive by ELISA and 41 (26.3%) by CFT. Of the 3,880 sera from cattle in the herds which had no history or evidence of paratuberculosis, 3,875 (99.9%) were negative by ELISA, and 3,787 (97.6%) by CFT. Positive ELISA titers were detectable 1 to 5 months earlier than positive CFT titers in experimentally infected cattle, and 7 to 10 months earlier in naturally infected cattle. These results indicate that the ELISA should replace the CFT as the routine test of choice for the diagnosis of bovine paratuberculosis.  相似文献   

11.
An enzyme-linked immunosorbent assay (ELISA) for detection of Bordetella avium infection in turkey poults was developed. One-week-old poults challenged intratracheally with 10(12) colony-forming units of B. avium had detectable titers (greater than or equal to 11), with an average of 13.6% positive samples when the birds were 6 to 11 weeks old. The method was sensitive enough to detect maternal antibodies to B. avium in poults up to 3 weeks of age. The same poults challenged at 1 week of age had 100% tracheal infection up to 3 weeks of age, which dropped to 0% by 6 weeks. The method resulted in no false-positive samples (titer = 0) from birds not infected with B. avium and tested weekly between 4 and 11 weeks of age. Antibodies in turkey flocks infected with Newcastle disease virus, hemorrhagic enteritis virus, and Mycoplasma meleagridis, and birds infected with Escherichia coli had no apparent cross-reactivity to the B. avium antigens used in the ELISA. The percentages of B. avium-positive serum samples collected from different turkey flocks did not significantly differ (P greater than 0.05) when samples were tested by the developed ELISA at different times, an indication of the reproducibility of the method.  相似文献   

12.
An indirect enzyme-linked immunosorbent assay (ELISA) was developed to detect bovine antibody to vesicular stomatitis virus (VSV). Serum samples from cows experimentally infected with the New Jersey serotype of VSV (VSV-NJ) were assayed by the ELISA and serum-neutralization (SN) assay. The ELISA was as sensitive as the SN assay in detecting bovine antibody to VSV. The correlation between SN titers and ELISA values at absorbance at 405 nm was statistically significant. The ELISA was not specific for VSV-NJ, however, and could detect serum samples positive to the Indiana serotype of VSV that had SN titers of greater than or equal to 480. Nonspecific reactions were due to cross-reactive group-specific viral proteins that are shared by both serotypes. The cross-reactivity allows the use of a single rapid test in identifying both serotypes of VSV from the other exotic vesicular diseases, especially foot-and-mouth disease. The ELISA titers of serum samples positive for VSV-NJ were comparable with the corresponding SN titers of each sample. The sensitivity, rapidity, and ease of the ELISA system and the use of a single test in identifying both serotypes of VSV from the other exotic vesicular diseases make this ELISA suitable as a rapid diagnostic assay for VS.  相似文献   

13.
An enzyme-linked immunosorbent assay (ELISA) test was developed for the detection of specific antibodies against the unique infectious anemia (EIA) virus in equine sera. The ELISA test was faster and more sensitive when compared with the classic test of agar gel immunodiffusion (AGID). A total of 200 sera were tested: 100 from negative horses and 100 from positive horses by AGID. The ELISA test showed 92 horse sera negative and 100 horse sera positive by AGID with values of optical density (OD) less than 0.139 and higher than 0.139, respectively. Eight horse sera were negative by AGID and higher than 0.139 by ELISA. Six of these became AGID positive also when re-tested 30 days later, and two were of the horses that showed clinical signs of EIA and died before re-testing.  相似文献   

14.
A single-dilution indirect solid-phase radioimmunoassay (IRIA) was developed for the detection of low levels of anti-pseudorabies immunoglobulin G in swine sera. The assay derived increased sensitivity from the use of a second amplifying antibody. The IRIA was examined for its stoichiometry, amplification by secondary antibody, advantage of a single-dilution assay vs an end-point titration, sensitivity, and specificity. The assay had a near linear dose-response relationship with positive sera (serum-neutralization titer less than or equal to 1:16) and lacked a dose response with negative sera. With addition of the secondary antibody, the IRIA was enhanced 8.5-fold in net specific binding, and the end-point titer was amplified 32-fold. The single-dilution assay was proved to be a feasible test, compared with end-point titration. Anti-pseudorabies virus titers were at least 128-fold higher by IRIA than those by serum-neutralization test. Evidence indicated that there may be minimal or no cross-reactivity of IRIA antigen with anti-infectious bovine rhinotracheitis sera. The single-dilution IRIA was a rapid and sensitive test for anti-pseudorabies virus immunoglobulin G in swine sera.  相似文献   

15.
The enzyme-linked immunosorbent assay (ELISA) indicated significant cross-reactivity between the antigens of Mycoplasma hyopneumoniae ( HyoP ) and M. flocculare (Floc), another porcine mycoplasma of wide distribution but uncertain pathogenic significance, when porcine antisera of each specificity were tested against HyoP antigen. The titers of the anti-Floc sera ranged from threefold to 13-fold less than the titer of the anti- HyoP reference serum at different times after immunization. These values ranged from onefold less than to fourfold greater than the minimal positive titer of 80. The antisera to the other porcine mycoplasmal antigens [i.e. M. hyorhinis ( HyoR ) and M. hyosynoviae ( HyoS )] reacted less strongly to HyoP antigen but titers only slightly less than to slightly greater than the minimal positive titer were noted for some sera. Cross-reactivity was also detected by the complement fixation test, although the titers for this test were generally lower than for the ELISA, presumably reflecting lower sensitivity of the complement fixation test. Positive indirect hemagglutination titers to HyoP antigen were also observed for both anti-Floc sera obtained at one or more times during the immune response. With two exceptions (one anti- HyoR serum with a complement fixation titer of 16 and one anti- HyoR serum with an indirect hemagglutination titer of 10), none of the anti- HyoR or anti- HyoS sera had detectable indirect hemagglutination or complement fixation titers to HyoP antigen at any time after immunization. The levels of cross-reactivity detected by the complement fixation test and indirect hemagglutination and, especially, the ELISA would be of significance for the development of any practical sero-diagnostic test for mycoplasmal pneumonia of swine.  相似文献   

16.
A dot-immunobinding assay was enhanced by the incorporation of avidin and biotin reagents into the test system (DAB assay). This assay was used to detect serum antibodies to Mycoplasma gallisepticum (MG) and M. synoviae (MS) from chickens. Serum samples were tested by rapid serum plate (RSP), hemagglutination-inhibition (HI), and DAB assay methods. These results were compared. The DAB assay was at least 20 times more sensitive in detecting antibodies for MS and at least 75 times more sensitive in detecting antibodies for MG than the HI test. The DAB assay was as specific as the HI test. The DAB assay was also more sensitive and specific than the RSP test. Some cross-reactions occurred when low dilutions of high-titer sera were used in the DAB assay. Parameters for determining negative, suspicious, and positive samples were established. The DAB assay for MG and MS may have several applications, including use as a screening test and a confirmatory test.  相似文献   

17.
Three hundred two dogs were tested with 4 serotests for heartworm antigen (AG) or antibody (AB) and with the Knott test. The 4 serotests evaluated were an enzyme-linked immunosorbent assay (ELISA) for adult heartworm-specific AB (AB-ELISA), a quantitative, indirect immunofluorescent assay (IFA) for adult heartworm-specific AB (AB-IFA), an IFA test for microfilaria (MF)-specific AB (MF-IFA), and an ELISA for adult heartworm AG (AG-ELISA). The presence of heartworms was ascertained in all dogs by necropsy examination. Of 302 dogs, 20 (6.6%) had heartworms in the heart at necropsy. Of infected dogs, 9 (45%) had occult infections. Test sensitivities were 75%, 95%, 70%, and 75% for the AB-ELISA, AB-IFA, MF-IFA, and AG-ELISA, respectively. Test specificities were 85% (AB-ELISA), 77% (AB-IFA), 87% (MF-IFA), and 99% (AG-ELISA). The best agreement between serotest results and necropsy findings was obtained with the AG-ELISA (97%). The 4 serotests detected 86% (AB-ELISA), 100% (AB-IFA), 67% (MF-IFA), and 78% (AG-ELISA) of the dogs with occult heartworm infection. A significant (P less than 0.05) association between intestinal parasitism and positive heartworm test results was found with only AB-IFA. Seemingly, the Knott test, or some other concentration method for detecting circulating MF should be the first heartworm test performed. If the examination for MF is negative, the dog has clinical signs, and radiographic findings are suggestive of occult heartworm infection, then a serotest for adult heartworm AG is recommended.  相似文献   

18.
A reliable bovine viral diarrhea (BVD) viral antigen was prepared from BVD virus grown on Madin Darby bovine kidney (MDBK) cells by solubilizing the virus with detergent MEGA-10 (decanoyl-N-methylglucamide) followed by removal of hydrophobic proteins with Triton X-100 treatment. By these treatments, problems of high background associated with BVD viral antigen in the enzyme-linked immunosorbent assay (ELISA) were eliminated. With this new antigen, an ELISA was adapted to detect bovine serum antibody against BVD virus. The diagnostic specificity of the assay in 403 bovine sera collected from a BVD virus-free herd was 100%; in 296 bovine sera with serum neutralizing antibody titers of greater than or equal to 1:2, 289 sera were ELISA positive (relative sensitivity of 97.6%), two sera gave false negative reactions (0.7%) and five sera gave suspicious reactions (1.7%). These interpretations were based on positive/negative (P/N) ratio readings, i.e. a P/N ratio of less than 1.50, 1.50-1.99 and greater than or equal to 2.00 were interpreted as negative, suspicious and positive reactions, respectively. The ELISA results gave excellent agreement with serum neutralization in detecting both seropositive and seronegative animals (Kappa = 0.994). The ELISA assay was considered to be technically superior to the serum neutralization test for the routine detection of BVD viral antibody in bovine sera.  相似文献   

19.
The immune responses of 514 pigs from 5 swine breeds (Chester White, Duroc, Hampshire, Landrace, Yorkshire) to vaccination with Bordetella bronchiseptica were measured by agglutination and enzyme-linked immunosorbent assay (ELISA) methods. Both assays showed higher antibody levels in sera of pigs after vaccination than in sera of the pigs before vaccination. The variability of the responses among breeds was greater for the agglutination method than for the ELISA method. The ELISA proved to be more sensitive than the agglutination method and could detect antibody in serum samples diluted at least 100-fold more than those used in the agglutination procedure. The correlation of antibody titers obtained by the 2 methods was small, but statistically (P less than 0.01) significant. The ELISA should be useful for determinations of antibody responses of swine to B bronchiseptica.  相似文献   

20.
The indirect fluorescent antibody test was used to examine 109 samples of equine sera randomly selected from serum pools. Results were compared with titers obtained by the microagglutination (MA) test. A high correlation (r = 0.89) was found between titers measured by the 2 tests. Blood samples were obtained serially from a total of 156 horses at a research farm and the sera were tested against Legionella pneumophila serogroups 1 through 4 using the MA test; 29 horses (19%) seroconverted to at least 1 serogroup of L pneumophila. The indirect fluorescent antibody test substantiated the results obtained by the MA test. Seroconversions in horses provided additional evidence that horses become naturally exposed to legionellae.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号