1.
OBJECTIVE--To compare the biomechanical characteristics and mode of failure of 2 parallel-screw techniques for proximal interphalangeal joint arthrodesis in horses. STUDY DESIGN--Randomized block design, blocking for horse (1-5), method of screw fixation (three 4.5-mm vs two 5.5-mm), side (left limb vs right limb), and end (front limb vs hind limb). Constructs were loaded to failure in 3-point bending in a dorsal-to-palmar (plantar) direction. SAMPLE POPULATION--Twenty limbs (10 limb pairs) from 5 equine cadavers. METHODS--A combined aiming device was used to facilitate consistent screw placement. Three parallel 4.5-mm cortical screws were placed in lag fashion in 1 limb of a pair, and 2 parallel 5.5-mm cortical screws were placed in lag fashion in the contralateral limb. Arthrodesis constructs were tested in 3-point bending in a dorsal-to-palmar (plantar) direction using a materials-testing machine. Loading rate was 19 mm/s. Maximal bending moment at failure and composite stiffness were obtained from bending moment-angular deformation curves. Data were analyzed using ANOVA and chi(2) analysis. RESULTS--There were no significant differences in bending moment (P >.05, power = 0.8 @ delta = 19%) or composite stiffness (P >.05, power = 0.8 @ delta = 19%) between the 2 fixation techniques. Higher maximal bending moment was found in front limbs than hind limbs, and front limbs with two 5.5-mm screws than hind limbs with two 5.5-mm screws. In all cases, constructs completely failed. A greater number of 4.5-mm cortical screws failed than 5.5-mm cortical screws. CONCLUSIONS-In pastern arthrodesis constructs loaded in 3-point bending, end (front limb vs hind limb) affected maximal bending moment at failure of constructs. There was no significant effect of horse, treatment, or side on maximal bending moment or stiffness. Two 5.5-mm cortical screws should provide a surgically simpler pastern arthrodesis than three 4.5-mm cortical screws while maintaining similar biomechanical characteristics. CLINICAL RELEVANCE--Three 4.5-mm screws or two 5.5-mm screws will provide similar biomechanical characteristics in bending when performing equine pastern arthrodesis.  相似文献   

2.
Seven-hole 3.5 mm broad and 5-hole 4.5 mm narrow dynamic compression plates were applied to paired canine cadaveric tibias in a stable fracture model. Paired tibias were tested to acute failure in rotation and four-point bending, and to fatigue failure in four-point bending. Resistance to screw pullout was measured for three 3.5 mm cortical screws and two 4.5 mm cortical screws inserted in the configurations of the bone plates. All plate-bone systems failed by fracture of the bone through a screw hole. The 3.5 mm plate-bone system was stronger in acute failure in rotation and in four-point bending. There was no difference in stiffness, and no difference in the number of cycles to failure in fatigue testing. Three 3.5 mm screws had greater resistance to pullout than two 4.5 mm screws. Results indicate that the 7-hole 3.5 mm broad dynamic compression plate has a biomechanical advantage over the 5-hole 4.5 mm narrow dynamic compression plate.  相似文献   

3.
The objective of this study was to compare the biomechanical properties in a single cycle axial loading test and the types of failures in two constructs (a 3-hole 4.5-mm dynamic compression plate (DCP) and 7-hole 5.5-mm Y locking compression plate (Y-LCP)) in equine proximal interphalangeal joint (PIJ) arthrodesis. One limb in each pair was randomly assigned to PIJ arthrodesis using a 3-hole 4.5-mm DCP combined with two transarticular 5.5-mm cortical screws, whereas the contralateral limb was submitted to PIJ arthrodesis using a 7-hole Y-shaped 5.0-mm LCP in conjunction with one transarticular 4.5-mm cortical screw inserted through the central plate hole. Cortical screws were inserted in lag fashion. Constructs were submitted to a single axial load cycle to failure. Construct stiffness, load, and deformation were analyzed. Dynamic compression plate and Y-LCP arthrodesis constructs did not differ significantly and were equally resistant to axial loading under the conditions studied (DCP and Y-LCP group stiffness, 5685.22 N/mm and 6591.10 N/mm, respectively). Arthrodesis of the PIJ using a DCP and two transarticular 5.5-mm cortical screws or a Y-LCP yielded biomechanically equivalent outcomes under the test conditions considered. However, Y-LCP provides less impact in the palmar/plantar bone. Application of Y-LCP with unicortical screws has equivalent biomechanical characteristics of DCP and may be a safe option for PIJ arthrodesis, where potential trauma secondary to applying bicortical screws in the palmar/plantar aspect of the pastern can be avoided.  相似文献   

4.
OBJECTIVE: To evaluate and compare the mechanical properties of 4.5 narrow and 3.5 broad plating systems using their respective cortical and cancellous screws in unstable, central, and eccentric gap fracture models. STUDY DESIGN: Mechanical evaluation and comparison of 2 dynamic compression plate (DCP) systems. SAMPLE POPULATION: Eighteen cortical and 30 cancellous gapped fracture models. METHODS: DCP (4.5 mm narrow, 3.5 mm broad) with their respective cortical screws were applied to cortical bone density polyurethane foam blocks to construct center gap cortical fracture models that were tested in gap closing monotonic 4-point bending. DCP (4.5 mm narrow, 3.5 mm broad) with their respective cancellous screws were applied to cancellous bone density polyurethane foam blocks to construct eccentric gap cancellous fracture models. The cancellous constructs were tested in monotonic gap opening and gap closing cantilever bending and in cyclic axial loading. Univariate and multivariate repeated measures ANOVA were used to compare the maximum loads at failure of the 4.5 mm constructs and 3.5 mm constructs. RESULTS: The 4.5 mm narrow plating system withstood significantly higher loads at failure than the 3.5 mm broad plating system in 4-point bending (P<.0001) and gap opening cantilever bending (P<.0001). The 4.5 mm system failed in gap closing cantilever bending by plastic deformation of the plate, whereas the 3.5 mm system failed by screw pullout. There was no difference between the 2 systems in cyclic axial loading. CONCLUSION: Results indicate that the 4.5 mm narrow plating system has a mechanical advantage over the 3.5 mm broad plating system for stabilization of gapped fracture models. CLINICAL RELEVANCE: The 4.5 mm narrow plating system may be mechanically advantageous compared with the 3.5 mm broad plating system for stabilizing unreconstructed comminuted long bone fractures in large dogs.  相似文献   

5.
Objective—To determine and compare the in vitro pullout strength of 5.5-mm cortical versus 6.5-mm cancellous bone screws inserted in the diaphysis and metaphysis of adult equine third metacarpal (MCIII) bones, in threaded 4.5-mm cortical bone screw insertion holes that were then overdrilled with a 4.5-mm drill bit to provide information relevant to the selection of a replacement screw if a 4.5-mm cortical screw is stripped. Study Design—In vitro pullout tests of 5.5-mm cortical and 6.5-mm cancellous screws in equine MCIII bones. Sample Population—Two independent cadaver studies each consisting of 14 adult equine MCIII bones. Methods—Two 4.5-mm cortical screws were placed either in the middiaphysis (study 1) or distal metaphysis (study 2) of MCIII bones. The holes were then overdrilled with a 4.5-mm drill bit and had either a 5.5-mm cortical or a 6.5-mm cancellous screw inserted; screw pullout tests were performed at a rate of 0.04 mm/second until screw or bone failure occurred. Results—In diaphyseal bone, the screws failed in all tests. Tensile breaking strength for 5.5-mm cortical screws (997.5 ± 49.3 kg) and 6.5-mm cancellous screws (931.6 ± 19.5 kg) was not significantly different. In metaphyseal bone, the bone failed in all tests. The holding power for 6.5-mm cancellous screws (39.1 ± 4.9 kg/mm) was significantly greater than 5.5-mm cortical screws (23.5 ± 3.5 kg/mm) in the metaphysis. There was no difference in the tensile breaking strength of screws in the diaphysis between proximal and distal screw holes; however, the holding power was significantly greater in the distal, compared with the proximal, metaphyseal holes. Conclusions—Although tensile breaking strength was not different between 5.5-mm cortical and 6.5-mm cancellous screws in middiaphyseal cortical bone, holding power of 6.5-mm cancellous screws was greater than 5.5-mm cortical screws in metaphyseal bone of adult horses. Clinical Relevance—If a 4.5-mm cortical bone screw strips in MCIII diaphyseal bone of adult horses, either a 5.5-mm cortical or 6.5-mm cancellous screw, however, would have equivalent pullout strengths. A 6.5-mm cancellous screw, however, would provide greater holding power than a 5.5-mm cortical screw in metaphyseal bone.  相似文献   

6.
Objective: To (1) compare the effect of a collateral ligament sparing surgical approach with an open surgical approach on mechanical properties of proximal interphalangeal joint (PIPJ) arthrodesis, and (2) to determine the percentage of articular cartilage surface removed by transarticular (TA) drilling with different diameter drill bits. Study Design: Randomized paired limb design. Sample Population: Cadaveric equine limbs (n=76). Methods: Cadaveric PIPJ were drilled using a 3.5, 4.5, or 5.5 mm drill bit at 80–84° to the dorsal plane to remove articular cartilage and subchondral bone from the distal articular surface of the proximal phalanx (P1) and the proximal articular surface of the middle phalanx (P2). Bone ends were photographed and the percentage of the projected surface area that was denuded of cartilage was measured. PIPJ arthrodesis constructs (3‐hole dynamic compression plate [DCP], two 5.5 mm TA screws inserted in lag fashion, medial and lateral to the DCP; DCP‐TA) were created using 2 surgical approaches in paired limbs. A conventional open approach was used in 1 limb and a collateral ligament sparing approach used in the other limb. Constructs were tested to failure in single‐cycle 3‐point dorsopalmar/plantar or lateromedial bending. Maximum load, yield load, and composite stiffness were compared between techniques. Results: The 3.5, 4.5, and 5.5 mm drill bits removed 24±4%, 35±5%, and 45±7% of total PIPJ articular cartilage surface, respectively. Constructs with the collateral ligament sparing approach had significantly greater mean yield load (11.3±2.8 versus 7.68±1.1 kN, P=.008) and mean maximum load (13.5±3.1 versus 10.1±1.94 kN, P=.02) under lateromedial bending. Under dorsopalmar/plantar bending there was no significant difference between surgical approaches. The collateral ligament sparing arthrodesis technique had a shorter surgical time (19±3 minutes) compared with the open technique (31±3 minutes). Conclusion: A collateral ligament sparing surgical approach to the PIPJ with removal of articular cartilage by TA drilling and arthrodesis by DCP‐TA was faster and stronger in mediolateral bending than arthrodesis constructs created with an open surgical approach. Clinical Relevance: Preservation of the collateral ligaments and TA drilling for cartilage removal during PIPJ arthrodesis may be a superior approach to the conventional open approach and warrants clinical evaluation.  相似文献   

7.
OBJECTIVES: To compare the monotonic biomechanical properties of a prototype equine third metacarpal dynamic compression plate (EM-DCP) fixation with a double broad dynamic compression plate (DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional testing. The EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of one randomly selected bone from each pair. Two DCPs, 1 dorsally (10-hole, 4.5 mm broad) and 1 laterally (9-hole, 4.5 mm broad) were applied to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the EM-DCP fixation were significantly greater (P<.0001) than those of the double broad DCP fixation. Mean cycles to failure in 4-point bending of the EM-DCP fixation was significantly greater (P<.0008) than that of the double broad DCP fixation. Mean yield load, composite rigidity, and failure load in torsion of the EM-DCP fixation were significantly greater (P<.0035) than that of the double broad DCP fixation. CONCLUSION: The EM-DCP provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: Results of this in vitro study support the conclusion that the prototype EM-DCP fixation is biomechanically superior to the double broad DCP fixation for the stabilization of osteotomized equine MC3.  相似文献   

8.
OBJECTIVE: To compare the mechanical properties of 2 configurations of a veterinary fixation system (VFS) for large animal long bones with dynamic compression plating (DCP). SAMPLE POPULATION: Eighteen pairs of Canevasit tubes (Canevasit; Amsler und Frei, Schinznach Dorf, Switzerland) (length, 170 mm; diameter, 47.5 mm; cortex thickness, 10 mm), aligned with a 10-mm gap, and stabilized with 2 DCP or 2 VFS implants. METHODS: Three groups (n = 6) were compared. Group 1 Canevasit tubes were stabilized with two 10-hole, broad 4.5-mm stainless steel DCP applied with both plates centered over the gap, in orthogonal planes parallel to the long axis of the tubes and staggered to allow bicortical fixation with ten 4.5-mm, 52-mm-long cortex screws each. Group 2 tubes were stabilized similarly with 2 VFS implants, each composed of a stainless steel rod (length, 167 mm; diameter, 8 mm), and 10 clamps were applied in alternating fashion left and right on the rod and fixed bicortically with ten 4.5-mm, 52-mm-long, cortex screws. Group 3 tubes were stabilized similarly, but using only 6 clamps/rod. All groups were tested initially in torsion within elastic limits and subsequently in 4-point bending, with 1 implant on the tension side, until gap closure occurred. RESULTS: None of the constructs failed, but all had plastic deformation after 4-point bending. No statistically significant differences were found among the 3 groups in torsional stiffness. Double DCP fixation was significantly stiffer and stronger in 4-point bending, compared with both configurations of double VFS fixation. CONCLUSIONS: The plate design was favored in this study. The VFS system may have to be adapted before further tests are conducted. Test modalities have to be chosen closer to clinical conditions (real bone, cyclic loading, closed gap). CLINICAL RELEVANCE: The veterinary fixation system has not yet proven its advantages for large animal long bone fracture repair. From the pure mechanical point of view, double DCP is the favored method for the treatment mentioned.  相似文献   

9.
OBJECTIVE--To compare the mechanical properties of 2 interlocking-nail systems for fixation of ostectomized equine third metacarpi (MC3): (1) a standard interlocking nail with 2 parallel screws proximal and distal to a 1-cm ostectomy; and (2) a modified interlocking nail with 2 screws proximal and distal to a 1-cm ostectomy with the screws offset by 30 degrees. ANIMAL OR SAMPLE POPULATION--Twelve pairs of adult equine forelimbs intact from the midradius distally. METHODS--Twelve pairs of equine MC3 were divided into 2 test groups (6 pairs each): torsion and caudocranial 4-point bending. Standard interlocking nails (6-hole, 13-mm diameter, 230-mm length) were placed in 1 randomly selected bone from each pair. Modified interlocking nails (6-hole, 13-mm, 230-mm length, screw holes offset by 30 degrees) were placed in the contralateral bone from each pair. All bones had 1-cm mid-diaphyseal ostectomies. Six construct pairs were tested in caudocranial 4-point bending to determine stiffness and failure properties. The remaining 6 construct pairs were tested in torsion to determine torsional stiffness and yield load. Mean values for each fixation method were compared using a paired t test within each group. Significance was set at P <.05. RESULTS--Mean (+/-SEM) values for the MC3-standard interlocking-nail composite and the MC3-modified interlocking-nail composite, respectively, in 4-point bending were: composite rigidity, 3,119 +/- 334.5 Nm/rad (newton. meter/radian) and 3,185 +/- 401.2 Nm/rad; yield bending moment, 205.0 +/- 18.46 Nm and 186.7 +/- 6.17 Nm; and failure bending moment, 366.4 +/- 21.82 Nm and 378.1 +/- 20.41 Nm. There were no significant differences in the biomechanical values for bending between the 2 fixation methods. In torsion, mean (+/-SEM) values for the MC3-standard interlocking-nail composite and the MC3-modified interlocking-nail composite were: composite rigidity, 135.5 +/- 7.128 Nm/rad and 112.5 +/- 7.432 Nm/rad; gap stiffness, 207.6 +/- 10.57 Nm/rad and 181.7 +/- 12.89 Nm/rad; and yield load, 123.3 +/- 2.563 Nm and 107.5 +/- 8.353 Nm, respectively. Composite rigidity and gap stiffness for standard interlocking-nail fixations were significantly higher than the modified interlocking-nail fixation technique in torsion. Yield load had a tendency to be higher for the standard interlocking-nail fixation (P =.15). CONCLUSIONS--No significant differences in biomechanical properties were identified between a standard interlocking nail and one with the screw holes offset by 30 degrees in caudocranial 4-point bending. The standard interlocking nail was superior to the modified interlocking nail in torsional gap stiffness and composite rigidity. The torsional yield load also tended to be higher for the standard interlocking nail. CLINICAL RELEVANCE--The standard interlocking nail with parallel screw holes is superior to a modified interlocking nail with the screw holes offset by 30 degrees in ostectomized equine MC3 bones in vitro when tested in torsion.  相似文献   

10.
OBJECTIVES: To compare the monotonic biomechanical properties and fatigue life of a broad, limited contact, dynamic compression plate (LC-DCP) fixation with a broad, dynamic compression plate (DCP) fixation to repair osteotomized equine 3rd metacarpal (MC3) bones. STUDY DESIGN: In vitro biomechanical testing of paired cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Twelve pairs of adult equine cadaveric MC3 bones. METHODS: Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An LC-DCP (8-hole, 4.5 mm) was applied to the dorsal surface of 1 randomly selected bone from each pair. One DCP (8-hole, 4.5 mm broad) was applied dorsally to the contralateral bone from each pair. All plates and screws were applied using standard AO/ASIF techniques to MC3 bones that had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: The mean 4-point bending yield load, yield bending moment, composite rigidity, failure load, and failure bending moment of LC-DCP fixation were significantly greater (P<.01) than those of broad DCP fixation. Mean cycles to failure for 4-point bending was significantly (P<.001) greater for broad DCP fixation compared with broad LC-DCP fixation. Mean yield load, mean composite rigidity, and mean failure load in torsion was significantly (P<.02) greater for broad LC-DCP fixation compared with broad DCP fixation. CONCLUSION: Broad LC-DCP offers increased stability in static overload testing, however, it offers significantly less stability in cyclic fatigue testing. CLINICAL RELEVANCE: The clinical relevance of the cyclic fatigue data supports the conclusion that the broad DCP fixation is biomechanically superior to the broad LC-DCP fixation in osteotomized equine MC3 bones despite the results of the static overload testing.  相似文献   

11.
Objective —To determine risk of failure of the Synthes 4.5-mm cannulated screw system instrumentation in equine bone and to compare its application with the Synthes 4.5-mm standard cortex screw system.
Study Design —The maximum insertion torque of the cannulated and standard cortex screw systems were compared with the ultimate torsional strengths of the equipment. Pullout strength and ultimate tensile load of cannulated and standard cortex screws were also determined.
Sample Population—Paired equine cadaver third metacarpal and third carpal bones.
Methods —Maximum insertion torque and ultimate torsional strengths were determined by using an axial-torsional, servohydraulic materials testing system and a hand-held torquometer. Pullout tests were performed by using a servohydraulic materials testing system.
Results —Maximum insertion torque of all cannulated instrumentation was less than ultimate torsional strength at all locations ( P < .05). Maximum insertion torques of cannulated taps and screws were greater than for standard taps and screws in the third carpal bone ( P < .002). Pullout strength of the cannulated screws was less than the standard cortex screws at all sites ( P < .001). Cannulated screws broke before bone failure in all but one bone specimen. Conclusions—The risk of cannulated instrument or screw failure during insertion into bone is theoretically low. The relatively low pullout strength of the cannulated screws implies that the interfragmentary compression achievable is likely to be less than with standard cortex screws. Clinical Relevance—The relatively low pullout strength of the cannulated screw suggests that its risk of failure during fracture repair is greater than with the standard cortex screw.  相似文献   

12.
OBJECTIVE: To compare the stiffness and strength of AO bone plates (DCP, LC-DCP, VCP, RCP, and LP) and the Clamp-Rod Internal Fixation System (CRIF). Study design: In vitro. Sample size: 12 individual implants of 18 plate dimensions and four sizes of CRIF, each corresponding to 2.0, 2.4/2.7, 3.5, or 4.5 mm screw sizes. METHODS: Implant-constructs of each plate and CRIF were created using Canevasit rods as a bone substitute in an unstable gap fracture model. Six implant-constructs of each type were tested under single cycle four-point bending loading, and six were tested under single cycle torsional loading until permanent plastic deformation occurred. RESULTS: Torsional stiffness and yield load of the DCP were always significantly greater than the CRIF within the same group. Bending properties of the 2.0 DCP were not significantly different to the 2.0 CRIF. The 2.7 DCP had significantly higher bending values than the 2.7 CRIF. The bending stiffness of the 3.5 DCP and 4.5 DCP was significantly less than their CRIF counterparts. While the bending yield load of the 3.5 DCP was significantly greater than the 3.5 CRIF, the bending yield load of the 4.5 DCP was significantly less than the 4.5 CRIF. CONCLUSION: A weakness was found in the torsional resistance of the CRIF constructs compared to the DCP constructs. CLINICAL SIGNIFICANCE: Bone holding power and applied screw torque should be considered when using the CRIF system in clinical application.  相似文献   

13.
OBJECTIVE: To compare the structural properties and the interfragmentary motion in ostectomized canine femurs stabilized with either an 8-mm interlocking nail system (IN) or a 10-hole dynamic compression broad plate (DCP). ANIMAL OR SAMPLE POPULATION: Ten pairs of adult canine femurs with a 25-mm mid-diaphyseal gap. METHODS: Bone specimens were divided into 2 groups (10 femurs each). Left femurs were stabilized with a DCP and 8 bicortical screws; right femurs were stabilized with an IN and 3 screws. Mechanical tests were performed in eccentric axial loading and in craniocaudal bending. The testing was first conducted nondestructively and then until breakage. Structural properties, ie, stiffness, yield limits, and failure limits, were determined. Interfragmentary motion was measured during nondestructive tests with the use of an optoelectronic device. Axial, transverse, and rotational motions were calculated. Mean values of stiffness, yield and failure limits, and axial and shear motions for each fixation method were compared using a paired t test within each group (P <.05). RESULTS: Mean (+/-SD) values of stiffness and failure limit were significantly higher for IN constructs than for DCP constructs in compression, while there was little difference in the results between each tested group in bending. Mean yield load values were significantly higher for IN than for DCP specimens in compression as well as in bending. The axial-motion analysis revealed significant differences between IN and DCP groups during bending tests only. The highest score of transverse motion at the gap was recorded during bending tests, and was higher for DCP than for IN specimens. There were insignificant differences between the two groups with regard to rotation around the diaphyseal axis. CONCLUSIONS AND CLINICAL RELEVANCE: Structural properties and interfragmentary shear motion analysis demonstrated a much higher rigidity in the IN-bone than in the DCP-bone constructs.  相似文献   

14.
OBJECTIVE: To compare screw insertion variables and pullout mechanical properties between AO 6.5-mm cancellous and 7.3-mm cannulated bone screws in foal femoral bone. STUDY DESIGN: A paired, in vitro mechanical study. SAMPLE POPULATION: Seven pairs of femora from immature (1-7 months) foals. METHODS: The 6.5 cancellous and 7.3-mm cannulated screws were inserted at standardized proximal and distal metaphyseal, and mid-diaphyseal locations. Insertion torque, force, and time to drill, tap (6.5-mm cancellous), guide wire insertion (7.3-mm cannulated), and screw insertion were measured. Screw pullout properties (yield and failure load, displacement, and energy, and stiffness) were determined from mechanical tests. The effects of screw type and location on insertion variables and pullout properties were assessed with repeated measures ANOVA. Pairwise comparisons were examined with post hoc contrasts. Significance was set at P<.05 for all comparisons. RESULTS: Insertion torques for the 7.3-mm cannulated screws were significantly greater than for the 6.5-mm tap, but significantly lower than for the 6.5-mm cancellous screws. Total screw insertion times were similar. Pullout properties of both screws were similar at each femoral location. The holding power of both screws was significantly greater in the mid-diaphysis than in either metaphyseal location. Pullout failure occurred by bone shearing at the bone-screw interface in all specimens. CONCLUSIONS: The 6.5-mm cancellous and 7.3-mm cannulated screws vary in insertion properties, but have similar pullout properties in the mid-diaphysis, proximal, and distal metaphysis of foal femora. Both screw types have greater holding power at the mid-diaphyseal location compared with metaphyseal locations. Based on overall similar holding powers of 6.5-mm cancellous and 7.3-mm cannulated screws, it is unlikely that increasing the screw diameter beyond 6.5 mm will provide increased holding power in foal femoral bone. CLINICAL RELEVANCE: Use of the 7.3-mm cannulated screw should be considered for foal femoral fracture repair when greater accuracy is needed, or when bone threads for the 6.5-mm cancellous screw have been stripped.  相似文献   

15.
Objective— To compare failure mode and bending moment of a canine pancarpal arthrodesis construct using either a 2.7 mm/3.5 mm hybrid dynamic compression plate (HDCP) or a 3.5 mm dynamic compression plate (DCP).
Study Design— Paired in vitro biomechanical testing of canine pancarpal arthrodesis constructs stabilized with either a 2.7/3.5 HDCP or 3.5 DCP.
Sample Population— Paired cadaveric canine antebrachii (n=5).
Methods— Pancarpal arthrodesis constructs were loaded to failure (point of maximum load) in 4-point bending using a materials-testing machine. Using this point of failure, bending moments were calculated from system variables for each construct and the 2 plating systems compared using a paired t-test. To examine the relationship between metacarpal diameter and screw diameter failure loads, linear regression was used and Pearson' correlation coefficient was calculated. Significance was set at P <.05.
Results— HDCP failed at higher loads than DCP for 9 of 10 constructs. The absolute difference in failure rates between the 2 plates was 0.552±0.182 N m, P =.0144 (95% confidence interval: −0.58 to 1.68). This is an 8.1% mean difference in bending strength. There was a significant linear correlation r=0.74 ( P -slope=.014) and 0.8 ( P -slope=.006) between metacarpal diameter and failure loads for the HDCP and 3.5 DCP, respectively.
Conclusion— There was a small but significant difference between bending moment at failure between 2.7/3.5 HDCP and 3.5 DCP constructs; however, the difference may not be clinically evident in all patients.
Clinical Relevance— The 2.7/3.5 HDCP has physical and mechanical properties making it a more desirable plate for pancarpal arthrodesis.  相似文献   

16.
Static Strength Evaluation of Sacroiliac Fracture-Separation Repairs   总被引:2,自引:0,他引:2  
The relative static strengths of seven fixation configurations for the repair of sacroiliac fracture-separations were determined. The fixation techniques were two 3.5 mm screws, one 4.5 mm screw, one 4.5 mm screw and a pin, two 4.5 mm screws, one 6.5 mm screw, one 6.5 mm screw and a pin, and two 6.5 mm screws. Each configuration was subjected to a torsional, a bending, and a shear disruptive force while the maximum load tolerated before failure was measured. Two screws were stronger than a single screw of similar size, two small screws were stronger than a single larger screw, and a reduction pin added no significant strength to a single screw repair. It was concluded that use of the largest screws possible will maximize the strength of a sacroiliac fracture-separation repair.  相似文献   

17.
OBJECTIVE: To compare screw insertion characteristics and pullout mechanical properties between self-tapping (ST) and non-self-tapping (NST) AO 4.5-mm cortical bone screws in adult equine third metacarpal bone (MC3). STUDY DESIGN: In vitro biomechanical experiment. ANIMALS OR SAMPLE POPULATION: Seven pairs of adult equine MC3. METHODS: Bicortical holes were drilled transversely in proximal metaphyseal, diaphyseal, and distal metaphyseal locations of paired MC3. NST screws were inserted in pre-tapped holes in 3 sites of one bone pair, and ST screws were inserted in non-tapped holes of contralateral MC3. Tapping and screw insertion times and maximum torques were measured. Screw pullout mechanical properties were determined. RESULTS: Screw insertion time was longer for ST screws. Total time for tapping and insertion (total insertion time) was over twice as long for NST screws. Statistically significant differences were not observed between screws for any pullout mechanical property. From pullout tests, diaphyseal locations had significantly stiffer and stronger structure than metaphyseal locations. Pullout failure more commonly occurred because of screw breakage than bone failure. Bone failure and bone comminution were more commonly associated with ST screws. Bone failure sites had pullout failure loads that were 90% of screw failure sites. CONCLUSIONS: NST and ST 4.5-mm-diameter cortical bone screws have similar pullout mechanical properties from adult equine MC3. ST screws require less than half the total insertion time of NST screws. CLINICAL RELEVANCE: Use of ST 4.5-mm-diameter cortical bone screws should be considered for repair of adult equine MC3 fractures; however, bone failures at screw sites should be monitored.  相似文献   

18.
An open radial fracture in an adult horse (450 kg) was repaired by internal fixation, using two 18-hole 4.5-mm broad dynamic compression plates and 5.5- and 4.5-mm bone screws. The fracture healed completely, but when evaluated 9 months after surgery, the horse was lame on the fractured limb at a trot. Local infiltration of anesthesia along the distal half of the bone plates greatly ameliorated the lameness, suggesting that the plates were irritating the soft tissues and extensor tendons along the cranial and lateral aspects of the antebrachium. Both bone plates were removed simultaneously with no complications, and the horse became sound.  相似文献   

19.
OBJECTIVE: To compare the biomechanical characteristics and mode of failure of 2 techniques using parallel 5.5 mm screws for pastern joint arthrodesis in horses. STUDY DESIGN: Randomized block design, for horse (1-5), method of fixation (two 5.5 mm screws versus three 5.5 mm screws), side (right, left), and end (front, hind). Constructs were tested to failure in 3-point bending. SAMPLE POPULATION: Twenty limbs (5 cadavers). METHODS: A combined aiming device was used to facilitate screw placement. Two parallel 5.5 mm screws were inserted in lag fashion in 1 limb of a pair, and three 5.5 mm screws were inserted in the contralateral limb. Constructs were then tested in 3-point bending in a dorsal-to-palmar (plantar) direction using a materials testing machine at a loading rate of 19 mm/s. Maximal bending moment at failure and stiffness were obtained from bending moment-angular deformation curves. RESULTS: There was no significant difference between two and three 5.5 mm screw constructs for bending moment and stiffness (P<.05). All constructs ultimately failed by bone fracture or screw bending. For proximal interphalangeal (PIP) joint arthrodesis constructs loaded in 3-point bending, no significant effect of treatment, side, or end on maximal bending moment or stiffness was detected. CONCLUSIONS: Two 5.5 mm cortical screws inserted in parallel should provide a surgically simpler and equally strong PIP joint arthrodesis compared with three 5.5 mm cortical screws. CLINICAL RELEVANCE: Two 5.5 mm cortical screws inserted in parallel for PIP joint arthrodesis should perform similarly under conditions used in this study, as three 5.5 mm screws inserted in a similar manner, when loaded under bending.  相似文献   

20.
OBJECTIVES: To compare biomechanical properties of a prototype 5.5 mm tapered shaft cortical screw (TSS) and 5.5 mm AO cortical screw for an equine third metacarpal dynamic compression plate (EM-DCP) fixation to repair osteotomized equine third metacarpal (MC3) bones. STUDY DESIGN: Paired in vitro biomechanical testing of cadaveric equine MC3 with a mid-diaphyseal osteotomy, stabilized by 1 of 2 methods for fracture fixation. ANIMAL POPULATION: Adult equine cadaveric MC3 bones (n=12 pairs). METHODS: Twelve pairs of equine MC3 were divided into 3 groups (4 pairs each) for (1) 4-point bending single cycle to failure testing, (2) 4-point bending cyclic fatigue testing, and (3) torsional single cycle to failure testing. An EM-DCP (10-hole, 4.5 mm) was applied to the dorsal surface of each, mid-diaphyseal osteotomized, MC3 pair. For each MC3 bone pair, 1 was randomly chosen to have the EM-DCP secured with four 5.5 mm TSS (2 screws proximal and distal to the osteotomy; TSS construct), two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws in the remaining holes. The control construct (AO construct) had four 5.5 mm AO cortical screws to secure the EM-DCP in the 2 holes proximal and distal to the osteotomy in the contralateral bone from each pair. The remaining holes of the EM-DCP were filled with two 5.5 mm AO cortical screws (most proximal and distal holes in the plate) and four 4.5 mm AO cortical screws. All plates and screws were applied using standard AO/ASIF techniques. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P<.05. RESULTS: Mean 4-point bending yield load, yield bending moment, bending composite rigidity, failure load and failure bending moment of the TSS construct were significantly greater (P<.00004 for yield and P<.00001 for failure loads) than those of the AO construct. Mean cycles to failure in 4-point bending of the TSS construct was significantly greater (P<.0002) than that of the AO construct. The mean yield load and composite rigidity in torsion of the TSS construct were significantly greater (P<.0039 and P<.00003, respectively) than that of the AO construct. CONCLUSION: The TSS construct provides increased stability in both static overload testing and cyclic fatigue testing. CLINICAL RELEVANCE: The results of this in vitro study support the conclusion that the EM-DCP fixation using the prototype 5.5 mm TSS is biomechanically superior to the EM-DCP fixation using 5.5 mm AO cortical screws for the stabilization of osteotomized equine MC3.  相似文献   