首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The purpose of this study was to produce a comprehensive anatomic atlas of CT anatomy of the dog for use by veterinary radiologists, clinicians, and surgeons. Whole-body CT images of two mature beagle dogs were made with the dogs supported in sternal recumbency and using a slice thickness of 13 mm. At the end of the CT session, each dog was euthanized, and while carefully maintaining the same position, the body was placed in a walk-in freezer until completely frozen. The body was then sectioned at 13-mm intervals, with the cuts matched as closely as possible to the CT slices. The frozen sections were cleaned, photographed, and radiographed using xeroradiography. Each CT image was studied and compared with its corresponding xeroradiograph and anatomic section to assist in the accurate identification of specific structures. Clinically relevant anatomic structures were identified and labeled in the three corresponding photographs (CT image, xeroradiograph, and anatomic section). In a previous paper, the head and neck of the mesaticephalic (beagle) dog was presented. In this paper, the thorax and cranial part of the abdomen of the dog are presented.  相似文献   

2.
The purpose of this study was to produce a comprehensive anatomic atlas of CT anatomy of the dog for use by veterinary radiologists, clinicians, and surgeons. Whole-body CT images of two mature beagle dogs were made with the dogs supported in sternal recumbency and using a slice thickness of 13 mm. At the end of the CT session, each dog was euthanized, and while carefully maintaining the same position, the body was frozen. The body was then sectioned at 13-mm intervals, with the cuts matched as closely as possible to the CT slices. The frozen sections were cleaned, photographed, and radiographed using xeroradiography. Each CT image was studied and compared with its corresponding xeroradiograph and anatomic section to assist in the accurate identification of specific structures. Clinically relevant anatomic structures were identified and labeled in the three corresponding photographs (CT image, xeroradiograph, and anatomic section). In previous papers, the head and neck, and the thorax and cranial abdomen of the mesaticephalic (beagle) dog were presented. In this paper, the caudal part of the abdomen and pelvis of the bitch and male dog are presented.  相似文献   

3.
The purpose of this study was to produce an anatomic reference for computed tomography (CT) of the head of the foal for use by radiologists, clinicians, and veterinary students. The head from each of 2 foals, euthanized for reasons unrelated to head pathology, was removed and prepared for CT scanning. Using a third-generation CT scanner, 5-mm contiguous transverse images were acquired. The heads were then frozen and sectioned using a band saw, with the cuts matched as closely as possible to the CT slices. The anatomic sections were photographed and radiographed. The radiographs and anatomic photographs were digitized and matched with the corresponding CT image. Each CT image was compared with its corresponding radiographic and anatomic section to assist in the accurate identification of specific structures. Clinically relevant structures were identified and labeled in corresponding images (CT, anatomic slice, and radiograph of slice). Only structures identified in the CT image were labeled in 1 of the other 2 images. Sagittal (reference) images of the horse's head were reconstructed from the transverse CT scans, and were used to indicate the level from which each of the transverse images was obtained. Corresponding labeled images were then formatted together with a legend for identification of specific anatomic structures.  相似文献   

4.
5.
6.
7.
8.
The aim of this study was to provide a detailed anatomic atlas of the cranial abdomen by means of computed tomography (CT). Three mature dogs, all mixed breed males, were used. The dogs were sedated, anaesthetized and positioned in sternal recumbency. CT scans from the eighth thoracic vertebra to the fourth lumbar vertebra were performed using a third-generation equipment (TOSHIBA 600HQ scanner) with 1 cm slice thickness. CT-images of the cranial abdomen were taken with soft-tissue window (WL: −14, WW: 658) settings. Dogs were killed and vascular-injection technique was performed: red and blue latex filled the vascular system. Injected dogs were frozen in the same position as used for CT examination and sectioned with an electric bandsaw at 1-cm-thick intervals. The cuts matched as closely as possible to the CT-images. The anatomic sections were compared and studied with the corresponding CT-images, and clinically relevant abdominal anatomic structures were identified and labelled on the corresponding CT-images. The results of our study could be used as a reference for evaluating CT-images of the canine cranial abdomen with abdominal diseases.  相似文献   

9.
This study aims to identify and describe structures of the temporal bone in normal dogs that can be depicted using computed tomography (CT). Five normal dogs of different breeds and both sexes ranging from 0.5 to 8 years were used as the study material. CT images of 2 mm thickness without abnormalities in the temporal bone were reviewed and analysed in bone and soft tissue settings. All images were compared with corresponding E 12 plastic-embedded cross sections of 3 mm thickness, which were acquired from anatomic cross sections of frozen beagles. The sections were provided from the Department of Pathobiology (Institute of Anatomy). CT is able to image all relevant bony structures within the temporal bone. Concerning soft tissue structures, CT allows their localization by using bony markers, i.e. the internal acustic meatus for the cranial nerves VII and VIII or the canals for the internal carotid artery and the temporal sinus. The provided reference images are meant to improve orientation within the complex anatomy of the temporal bone. On condition that slice thickness is equal to or smaller than 2 mm and bony setting is supplied, CT is able to visualize all relevant structures within the temporal bone. However, in clinical settings the combined look on air, liquids and bone as well as the contrast enhancement of soft tissues might prefer magnetic resonance imaging to CT.  相似文献   

10.
Preoperative knowledge of the renal vascular anatomy is important for selection of the appropriate feline renal donor. Intravenous urograms (IVUs) have been performed routinely to screen potential donors at the Veterinary Hospital of the University of Pennsylvania (VHUP), but the vascular phase views lack sufficient detail of the renal vascular anatomy. Computed tomography angiography (CTA), which requires a helical computed tomography (CT) scanner, has been found to provide superior renal vascular anatomic information of prospective human renal donors. The specific aims of this study were as follows: 1) develop the CTA technique for the feline patient; and 2) obtain preliminary information on feline renal vessel anatomy in potential renal donors. Ten healthy, potential feline renal donors were anesthetized and imaged using a third-generation helical CT scanner. The time delay between i.v. contrast medium injection and image acquisition, and other parameters of slice collimation, slice interval, pitch, exposure settings, and reconstruction algorithms were varied to maximize contrast medium opacification of the renal vascular anatomy. Optimal CTA acquisition parameters were determined to be: 1) 10-sec delay post-i.v. bolus of iodinated contrast medium; 2) two serially acquired (corresponding to arterial and venous phases) helical scans through the renal vasculature; 3) pitch of 2 (4 mm/sec patient translation, 2 mm slice collimation); and 4) 120-kVp, 160-mA, and 1-sec exposure settings. Retrospective reconstructed CTA transverse images obtained at a 2-mm slice width and a 1-mm slice interval in combination with two-dimensional reformatted images and three-dimensional reconstructed images were qualitatively evaluated for vascular anatomy; vascular anatomy was confirmed at surgery. Four cats had single renal arteries and veins bilaterally; four cats had double renal veins. One cat had a small accessory artery supplying the caudal pole of the left kidney. One cat had a left renal artery originating from the aorta at a 90 degrees angle with the cranial mesenteric artery. CTA of the feline renal vascular anatomy is feasible, and reconstruction techniques provide excellent anatomic vascular detail. CTA is now used routinely at VHUP to screen all potential feline renal donors.  相似文献   

11.
12.
The aims of the study were (1) to quantify the influence of selected imaging parameters on the image quality (slice thickness, mAs, and beam orientation) defining optimal conditions for scan protocols and (2) to evaluate the benefits of the 3D reconstruction techniques for visualization of NDS structures in dogs. CT-DCG was performed bilaterally in 32 heads of dogs. CT transverse images were obtained using a combination of two slice thickness values (0.8 mm and 2 mm) and two mAs values (50 mAs and 300 mAs). Two beam projection orientations were also tested: transverse plane (perpendicular to the hard palate) and oblique to the hard palate. Three-dimensional images were obtained using Volume Rendering (VR). Transverse beam projection proved to be superior for the assessment of the inferior and superior lacrimal canaliculi and lacrimal sac. In this study, there was no statistical difference regarding mAs values (50 mAs and 300 mAs) and slice thickness values (0.8 mm and 2 mm). Three-dimensional images were helpful for the assessment of topographic relationship between nasolacrimal structures and cranial landmarks.  相似文献   

13.
14.
15.
De Zani  D.  Borgonovo  S.  Biggi  M.  Vignati  S.  Scandella  M.  Lazzaretti  S.  Modina  S.  Zani  D. 《Veterinary research communications》2010,34(1):13-16
Clinical and radiographic investigations of paranasal sinuses in horses are difficult due to the complex anatomy of these regions, the lack of patognomonic symptoms, and the low sensitivity of conventional diagnostic techniques. The aim of this study was to produce an anatomical atlas to support computed tomography (CT) and sinuscopy of the paranasal sinuses of the adult horse. Transverse, sagittal, and dorsal CT images were acquired, and sinuscopy with both rigid and flexible endoscopes was performed. The heads were frozen and sectioned using a band saw, with the cuts aligned as close as possible with the CT transverse slices. Each CT image was compared with its corresponding anatomical section and sinuscopy image to assist in the accurate identification of specific structures.  相似文献   

16.
The purpose of this study was to provide a new reference for interpretation of the normal anatomy of the canine thorax as imaged using computed tomography (CT). Three mature dogs, all mixed breed males, were used for this study. The dogs were sedated, anaesthetized and maintained in sternal recumbency. CT study from the first to the thirteen thoracic vertebra was performed with a TOSHIBA 600 HQ scanner (third generation equipment). Dogs were killed and vascular-injection technique was performed: red latex and blue latex filled vascular system. Injected dogs were frozen and sectioned with an electric bandsaw, the cuts matched as closely as possible to the CT images. The CT images from this study are intended as a reference for clinical CT imaging studies of the thoracic cavity of the dog and for interpreting lesions of the thorax and associated structures.  相似文献   

17.
The anatomical and clinical studies of computed tomography (CT) in Camelidae are scarce. The use of CT in large animal medicine is currently limited by the logistic problems of acquiring computed tomographic images. Several CT studies exist on adult llamas, but not in camels. Accurate interpretation of the planimetric CT normal anatomy is necessary for the study and evaluation of pathological tissues. The purpose of our work was to evaluate the thorax of the newborn camel and related structures by means of CT images and macroscopic sections. One newborn camel of one week was used. It was euthanized for medical reasons unrelated to disease of the thorax. CT images were obtained and detailed anatomy of the thorax was acquired. Different CT windows, soft‐tissue and pulmonary windows, were applied in order to obtain detailed attenuation shades of the thoracic structures. The camel was frozen and sectioned using an electric saw, and we obtained high quality images of the thorax compared with CT images. Clinically relevant anatomic structures of the thorax cavity were identified and labelled in the corresponding CT and gross‐section photographs. The information presented in this paper should serve as an initial reference to evaluate CT images of the newborn camel thorax.  相似文献   

18.
The purpose of this study was to develop an optimized imaging protocol for canine dental imaging using single‐detector row CT and multidetector row CT. Two medium‐sized mesaticephalic cadaver dog heads were scanned using varying slice thickness, sequential vs. helical scanning mode, sequential CT table increment, pitch, image reconstruction algorithm, and an additional moderate edge enhancement filter. For each series, two reviewers scored dental roots as not visible (score: 0), partially visible (score: 1) or completely visible (score: 2). Sharpness of the dento‐alveolar margin was scored as blurry (score: 0), sharp (score: 1) or very sharp (score: 2). Consensus reader scores were compared among CT protocols. For single‐detector row CT, complete visualization of all tooth roots was only achieved with 1 mm slice thickness and image interval sequential or helical series (pitch of 1 or 2) using a high‐frequency image reconstruction algorithm with or without additional edge enhancement. For four‐detector row CT, complete visibility of all tooth roots was recorded in all series. For single‐detector row CT, all medium frequency algorithm series yielded blurry margin scores and all other series yielded sharp margin scores. For four‐detector row CT, sequential and helical 0.5 mm thickness images yielded very sharp dento‐alveolar margin scores, whereas the 1 mm series yielded only sharp margin scores. Authors concluded that the optimal dental imaging protocol was a sequential mode 1 mm slice thickness and interval with a high‐frequency image reconstruction algorithm and an additional moderate edge enhancement filter.  相似文献   

19.
20.
Computed tomographic images of the neck, thorax and abdomen in four healthy adult rabbits were obtained with a conventional CT using a slice-thickness of 5 mm. CT images were obtained with the animals positioned in sternal recumbency on a removable plastic support directly laying on the CT-table. At the end of the CT session, each rabbit was euthanized and, while carefully maintaining the same position on the plastic support, the animal was moved into a −20 °C freezer until completely frozen. Each cadaver was then sectioned at 10 mm slices, with the first section starting at the tip of the nose, respecting the imaging protocol. The frozen sections were cleaned and then photographed on each side. Anatomic structures were identified and labeled first on each side of the frozen section and then on the corresponding CT image with the aid of the available literature. Results from our study provide an atlas of normal cross-sectional gross and CT anatomy of the rabbit neck, thorax and abdomen, useful in the interpretation of any cross-sectional imaging modality in this species.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号