首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The purpose of this study was to evaluate simplified methods for iohexol plasma clearance estimation in dogs and cats. Serial blood samples were taken before and 5, 20, 40, 60, 80, 100, 120, 150, 180, and 240 minutes after a bolus injection of iohexol in 51 dogs and 25 cats. Iohexol plasma concentration was determined with X-ray fluorescence. Clearance was calculated by dividing the injected dose by the area under the plasma tracer elimination curve estimated with a 2-compartment pharmacologic model. Clearance was normalized to body surface area (BSA). The 10-point clearance was used as a reference for the evaluation of simplified methods. A 2-sample method based on a single exponential fit and a single-sample method based on a linear quadratic model were investigated. Simplified methods were evaluated by calculating the standard deviation of the difference (SDD) between the clearances obtained with the simplified methods and the 10-point reference method. All combinations of sampling times were evaluated. The best sampling times were chosen for dogs and cats as the ones yielding the lowest SDD. Linear regression analysis was performed between the reference method and the optimized simplified methods. The best combination of time for the 2-sample method was 5 and 120 minutes in dogs and 20 and 180 minutes in cats. The best time for sampling in the single-sample method was 120 minutes in dogs and 80 minutes in cats. Plasma clearance of iohexol can be estimated in dogs and cats from 1 or 2 blood samples with a reasonable margin of error.  相似文献   

2.
The purpose of this study was to evaluate simplified methods for estimation of Technetium Tc 99m (99mTc)-pentetate and orthoiodohippurate I 131 (131I-OIH) plasma clearance in dogs and cats with 1 and 2 blood samples. Plasma clearances were calculated after a bolus injection of 1.85-11.1 MBq of 99mTc-pentetate and 131I-OIH with a 2-compartment model based on a 12-point curve as a reference method in 21 dogs and 18 cats. Three 2-sample and 3 single-sample methods were investigated. The method yielding the smallest standard deviation of the difference between the reference method and the simplified method was selected as the optimal one. Linear regression analysis was performed between the reference method and the simplified method and coefficient of determination (R2) was calculated. For 99mTc-pentetate plasma clearance, the optimal 2-sample method was the one with a mono-compartment model with samples taken at specific times. For 131I-OIH plasma clearance, the estimation was improved slightly by raising the clearance calculated with a mono-compartment model to the power of an empirically determined parameter. The optimal single-sample method was the one with a linear quadratic regression between the volume of distribution of the tracer at a specific time and the clearance calculated with 12 samples. Two-sample methods performed significantly better than did single-sample methods. The conclusion is made that 99mTc-pentetate and 131I-OIH plasma clearances can be estimated in dogs and cats with 1 or 2 blood samples with a reasonable margin of error compared to plasma clearances calculated with a 2-compartment model and 12 blood samples.  相似文献   

3.
The purpose of the present study was to compare different pharmacokinetic models for estimation of glomerular filtration rate (GFR) in 50 dogs with pyometra. GFR was estimated by plasma clearance (CLplasma) of iohexol by four 1-compartment methods (CL1c), a 2-compartment method (CL2c), and the trapezoidal method (CLtr). Regression analysis was performed to establish correction formulas for prediction of CLtr from the CL1c values and to find optimal times of sampling. Standardization of clearance values to body weight (kg), body surface area (m2) and extracellular fluid volume (ECFV) was compared by ranking of values. CLtr and CL2c values were similar, whereas CL1c overestimated CLtr. CLtr could be predicted from 2 samples at 2 and 3 hours after injection, using the formula CLtr = 4.52 + 0.84CL1c - 0.00080(CL1c)2 (R2 = .97). Similar relationships were found when sampling at 2 and 4 hours or at 2, 3 and 4 hours after injection, whereas predictions from the 3- and 4-hour estimates were not optimal (R2 = .79). The 2-sample methods for calculating GFR/ECFV generally produced unreliable predictions of the complete curve GFR/ECFV values. For some dogs, the choice of standardization procedure substantially changed the apparent level of renal function relative to other dogs in the study. We conclude that by applying an appropriate correction formula, GFR may be estimated using 2 blood samples at 2 and 3, or 2 and 4 hours after injection of iohexol when renal function is normal or moderately reduced. The method of standardizing the analysis with respect to body size may influence interpretation of the results substantially.  相似文献   

4.
BACKGROUND: Glomerular filtration rate (GFR) decreases in the aging human kidney, but limited data exist in dogs. HYPOTHESIS: There is an effect of age and body size on estimated GFR in healthy dogs. ANIMALS: One hundred and eighteen healthy dogs of various breeds, ages, and body weights presenting to 3 referral centers. METHODS: GFR was estimated in clinically healthy dogs between 1 and 14 years of age. GFR was estimated from the plasma clearance of iohexol, by a compartmental model and an empirical correction formula, normalized to body weight in kilograms or liters of extracellular fluid volume (ECFV). For data analysis, dogs were divided into body weight quartiles 1.8-12.4, 13.2-25.5, 25.7-31.6, and 32.0-70.3 kg. RESULTS: In the complete data set, there was no trend toward lower estimated GFR/kg or GFR/ECFV with increasing age. GFR decreased with age in dogs in the smallest weight quartile only. A significant negative linear relationship was detected between body weight and estimated GFR/kg and GFR/ECFV. Reference ranges in different weight quartiles were 1.54-4.25, 1.29-3.50, 0.95-3.36, and 1.12-3.39 mL/min/kg, respectively. Standardization to ECFV rather than kilogram body weight did not produce substantial changes in the relationships between GFR estimates and age or weight. CONCLUSIONS AND CLINICAL IMPORTANCE: Interpretation of GFR results for early diagnosis of renal failure should take into account the weight and the age of the patient for small dogs.  相似文献   

5.
BACKGROUND: Chronic kidney failure is frequently seen in middle-aged and elderly cats. 51Chromium-ethylene diaminic tetraacetic acid (51Cr-EDTA) clearance and single blood sample (SBS) method are used in several species to estimate the glomerular filtration rate (GFR). HYPOTHESIS: The hypothesis of this study was that 51Cr-EDTA clearance could be determined using an SBS method in normal and hyperthyroid cats. ANIMALS: Forty-six cats were included in this study, with an average age of 9.5 years. Of these cats, 27 had hyperthyroidism; 19 were healthy. METHODS: After IV injection of 51Cr-EDTA (average dose: 4.25 MBq), 7 blood samples were obtained between 5 and 240 minutes. Reference clearance was calculated in mL/min and mL/min/kg body weight, using a 2-compartment model. Optimal time for clearance measurement with SBS was then determined by systematically comparing each individual plasma concentration to the reference multisample clearance. RESULTS: The average reference plasma clearance of 51Cr-EDTA for all cats was 14.9 mL/min (3.7 mL/min/kg). The clearance in hyperthyroid cats averaged 16.4 mL/min (4.3 mL/min/kg) and in normal cats averaged 10.3 mL/min (2.4 mL/min/kg). The optimal time for the SBS was 48 minutes after injection of tracer 51Cr-EDTA (R2= 0.9414), giving the following converting equation: clearance = (0.0066 x DV48 minutes) - 0.9277 (in mL/min). CONCLUSIONS AND CLINICAL IMPORTANCE: In this study, the single sample 51Cr-EDTA clearance method was used to estimate the global GFR in cats. The method identified differences in clearance between normal and hyperthyroid cats. The optimal time for an SBS was 48 minutes.  相似文献   

6.
Background: Chronic kidney failure is frequently seen in middle-aged and elderly cats. 51Chromium-ethylene diaminic tetraacetic acid (51Cr-EDTA) clearance and single blood sample (SBS) method are used in several species to estimate the glomerular filtration rate (GFR).
Hypothesis: The hypothesis of this study was that 51Cr-EDTA clearance could be determined using an SBS method in normal and hyperthyroid cats.
Animals: Forty-six cats were included in this study, with an average age of 9.5 years. Of these cats, 27 had hyperthyroidism; 19 were healthy.
Methods: After IV injection of 51Cr-EDTA (average dose: 4.25 MBq), 7 blood samples were obtained between 5 and 240 minutes. Reference clearance was calculated in mL/min and mL/min/kg body weight, using a 2-compartment model. Optimal time for clearance measurement with SBS was then determined by systematically comparing each individual plasma concentration to the reference multisample clearance.
Results: The average reference plasma clearance of 51Cr-EDTA for all cats was 14.9 mL/min (3.7 mL/min/kg). The clearance in hyperthyroid cats averaged 16.4 mL/min (4.3 mL/min/kg) and in normal cats averaged 10.3 mL/min (2.4 mL/min/kg).
The optimal time for the SBS was 48 minutes after injection of tracer 51Cr-EDTA ( R 2= 0.9414), giving the following converting equation: clearance = (0.0066 × DV48 minutes) – 0.9277 (in mL/min).
Conclusions and Clinical Importance: In this study, the single sample 51Cr-EDTA clearance method was used to estimate the global GFR in cats. The method identified differences in clearance between normal and hyperthyroid cats. The optimal time for an SBS was 48 minutes.  相似文献   

7.
The pharmacokinetics of a low molecular weight heparin (LMWH; Fragmin D) was studied in dogs after intravenous and subcutaneous administration, based on antifactor Xa- (anti-fXa-) activity. Each dosage was examined in 5 adult Beagles. After intravenous application of 25, 50 and 100 anti-fXaU./kg body weight (BW) the mean peak plasma heparin activity of 0.52 +/- 0.12 (x +/- s), 1.08 +/- 0.23 and 1.86 +/- 0.17 anti-fXaU./ml, respectively, was measured. After subcutaneous application of 50, 100 and 200 anti-fXaU./kg BW maximum heparin activity in the plasma was determined after 144-216 minutes (mean values) of 0.28 +/- 0.01, 0.52 +/- 0.06 or 1.09 +/- 0.20 anti-fXaU./ml. Intravenous application of LMWH has a short plasma terminal half-life (t50) between 49 and 76 minutes which depended on the dosage. After administration of 50 anti-fXaU./kg BW (74 minutes) and 100 anti-fXaU./kg BW (76 minutes) no essential difference was shown. A distinctly longer t50 was found after subcutaneous injection. After injection of 50, 100 and 200 anti-fXaU./kg BW t50 values of 81, 123 and 182 minutes were calculated. According to this, with increasing dosage a decrease of the total clearance was found for both application routes. The apparent volume of distribution after intravenously applicated LMWH ranged between 50 and 70 ml/kg BW. The absolute bioavailability calculated for the subcutaneous NMH-injection of 50 and 100 anti-fXaU./kg BW was 107% and 104%, respectively.  相似文献   

8.
Objective: To evaluate the relationship of body weight (BW) and size, dog velocity, and vertical ground reaction forces (GRF) from a large number of dogs of various sizes. Study Design: Clinical research. Animals: Orthopedically healthy dogs (n=129) Methods: BW and dog size, represented as height at the withers (WH), were obtained. Stance times (ST), vertical impulses (VI), and peak vertical forces (PVF) of thoracic and pelvic limbs were measured on a force plate at controlled trotting speed. They were evaluated against BW and WH using linear regression analysis in absolute (nonnormalized) values, and when normalized to BW and/or body size according to the theory of dynamic similarity. Relative velocities were calculated for each dog. Results: Absolute ST, VI, and PVF showed strong positive correlations with BW and/or body size. When GRFs were normalized to BW, correlations with body size were markedly reduced, but remained positive for VI, and turned negative for PVF. Normalizing the time‐dependent variables (ST and VI) also to WH eliminated most size influence. A small dependency of fully normalized GRF on body size remained that was because of differences in relative velocity between dogs of different sizes. Reference values for the fully normalized data are given. Conclusions: The inherent relationship between BW, body size, dog velocity, and vertical GRF was demonstrated. Clinical Relevance: BW, body size, and relative dog velocity must be accounted for when wanting to obtain GRF variables that are comparable between different dogs.  相似文献   

9.
Six adult domestic shorthair obese cats were given 3-mg/kg gentamicin sulfate by rapid i.v. and by s.c. injection in a cross-over design. The plasma concentration-time data were analyzed using statistical moment theory with no assumption of a specific compartmental model. Means +/- SD for the half-life, which was calculated from the terminal slope of the log concentration-time curve, were 1.37 +/- 0.24 and 1.24 +/- 0.22 h following i.v. and s.c. injection, respectively. The apparent volume of distribution at steady state was 118.55 +/- 19.83 ml/kg, and total body clearance was 1.07 +/- 0.25 ml/kg/min. Bioavailability was 83.58 +/- 14.83% after s.c. administration. The calculated s.c. dose in obese cats to produce an average steady-state concentration of 4 micrograms/ml is 2.5 mg/kg every 8 h compared to 3 mg/kg in normal-weight cats.  相似文献   

10.
Allometric scaling of M-mode cardiac measurements in normal adult dogs   总被引:1,自引:0,他引:1  
Indices for M-mode measurements in dogs usually have been based on the assumption that a linear relationship exists between these measurements and body weight (BW) or body surface area (BSA). The relationships between the geometry of 3-dimensional objects do not support this assumption. The purposes of this study were to retrospectively examine M-mode data from a large number of dogs of varying sizes and breeds that were examined by a large number of ultrasonographers, to use the allometric equation to determine the appropriate BW exponent required to predict these cardiac dimensions, and to determine normal mean values and prediction intervals for common M-mode variables. Linear regression analyses of data from 494 dogs (2.2-95 kg) revealed a good correlation between M-mode measurements and BW after logarithmic transformation of the data (r2 = .55-.88). Most variables were most closely related to an index of body length, BW(1/3), although the exponent that best predicted diastolic and systolic left ventricular wall thicknesses was closer to 0.25. No variable indexed well to BW or BSA. With these data, appropriate mean values and prediction intervals were calculated for normal dogs, allowing veterinarians to correctly and appropriately index M-mode values. The equations developed from this study appear to be applicable to adult dogs of most breeds.  相似文献   

11.
Gregory B.  Daniel  DVM  MS  Robert  DeNovo  DVM  MS  Anne  Bahr  DVM  MS  Gary T.  Smith  MD 《Veterinary radiology & ultrasound》2001,42(2):162-168
In this study, heart time-activity curve, created following intravenous injection of 99mTc-mebrofenin were used to quantify hepatic function in normal dogs and dogs with induced hepatic parenchymal cell damage. The results were compared to a direct measurement of hepatic extraction following mesenteric venous injection of 99mTc-mebrofenin. The heart time-activity curves were normalized and the area under the curve from 0-30 minutes and 0-60 minutes were determined. In addition, the half-time clearance rate of the heart time-activity curve was analyzed using a two-compartment model. Linear regression analysis was used to describe the relationship between the area under the normalized heart time-activity curve and hepatic extraction. There was good correlation between the area under the normalized heart time-activity curve and hepatic extraction. The best correlation was obtained from the 0-30 minute data (r2 = 0.92). A formula for calculating hepatic extraction was derived using linear regression analysis: Hepatic extraction = 1.092 - (0.0000308 x AUC0-30 minutes). There was good correlation between the half-time clearance rates from the heart time-activity curve and hepatic extraction. The best correlation was between the fast phase half-time clearance and hepatic extraction (r2 = 0.88). The area under a normalized heart time-activity curve can be used as a simple alternative to deconvolutional analysis for the determination of hepatic extraction as a measure of hepatic parenchymal cell function in the dog.  相似文献   

12.
Measurement of renal function in horses poses a particular challenge because plasma creatinine is influenced by muscle mass which is highly developed and variable between individuals, while conventional clearance methods involve potentially daunting problems, particularly urine collection and bladder washout. This paper provides data which enable technetium-diethyleneaminopentacetic acid (Tc-DTPA) clearance to be used to calculate glomerular filtration rate (GFR)/extracellular fluid volume (ECFV) as an expression of GFR in horses, as previously validated in humans, dogs and calves. Apart from being arguably a more physiological expression of GFR than using derivatives of body weight, the use of GFR/ECFV eliminates a source of delay and error, namely measurement of the injected dose, and offers the convenience of requiring only three blood samples. It therefore has advantages for both research and clinical applications.  相似文献   

13.
Changes in the regional cerebral blood flow (rCBF), a measure for regional cerebral metabolism, have been reported in dogs suffering from behavioral problems like shadow chasing, anxiety, and compulsive disorders. The rCBF can be measured with single-photon emission computed tomography. Although the acquisition is performed afterward under general anesthesia, the distribution of technetium-99m-ethylene-diylbis-l-cysteine diethyl ester or 99mTc-ECD, a tracer which becomes trapped in the brain, represents the rCBF at the moment the tracer was administered to the awake dog (fixed or frozen image). The aim of this study was to examine the in vivo stability and the duration of the fixed distribution of this tracer in the canine brain. Three acquisitions were performed 15, 40, and 65 minutes after tracer injection. Total counts and perfusion indices, normalized to the total brain counts and to the cerebellum, were calculated (semiquantification). At T65, significant differences in the perfusion indices occurred compared with at T15. This study shows that in dogs, regional differences in the clearance of 99mTc-ECD result in significant alterations of the perfusion indices from 65 minutes onward after tracer injection. Therefore, it is recommended to start the acquisition between 15 and 40 minutes postinjection in dogs when this technique is used for studying rCBF alterations in dogs with behavioral problems.  相似文献   

14.
OBJECTIVE: To determine the effect of number of blood samples and sampling times on plasma clearance of technetium Tc 99m pentetate (Tc99mP) and orthoiodohippurate sodium I 131(OIH). ANIMALS: 20 dogs and 14 cats. PROCEDURE: Plasma clearances of OIH and Tc99mP were calculated by use of a 2-compartment model, on the basis of a 12-point curve as a reference method. Plasma clearance was calculated by use of all possible combinations of 4 to 11 samples. Time schedule yielding the smallest difference from the reference method was considered to be optimal. Regression analysis was performed between the 12-point model and models using a reduced number of samples. RESULTS: SD of the difference between the 12-point clearance and the models with reduced numbers of samples increased when the number of samples decreased. The SD of the difference between 12-point clearance and 4-point clearance was 4.17 ml/min for OIH and 0.94 ml/min for Tc99mP in dogs and 0.45 ml/min for OIH and 0.11 ml/min for Tc99mP in cats. Optimal schedules were distributed logarithmically and included an early sample at 5 or 10 minutes, a late sample at 2.5, 3, 4, or 5 hours for OIH, and a late sample at 4 or 5 hours for Tc99mP. CONCLUSIONS AND CLINICAL RELEVANCE: Plasma clearances of OIH and Tc99mP can be accurately calculated in dogs and cats by use of a single-injection 2-compartment pharmacologic model with a reduced number of blood samples, resulting in an acceptable margin of error.  相似文献   

15.
Single-photon emission computed tomography (SPECT) can be used to study the regional distribution of the cerebral blood flow in the feline brain without interference of anesthetics. When the tracer, 99mtechnetium-ethyl cysteinate dimer (99mTc-ECD), is injected in the awake animal, the acquisition can be performed afterward under general anesthesia, whereas the tracer distribution still represents the regional cerebral blood flow (rCBF) in the awake animal. The aim of this study was to look at the in vivo stability of 99mTc-ECD in the feline brain. For this purpose, 6 cats (n = 6) were used, and 3 serial acquisitions were performed starting at 40 (T40), 60 (T60), and 85 (T85) minutes after tracer injection. Total counts and perfusion indices (PIs), normalized to the total brain and to the cerebellum, were calculated. When T85 was compared with T40, total counts decreased, depending on the brain region, with 29% (left thalamus) to 51% (bulbus olfactorius). These regional differences in tracer clearance resulted in significantly altered PIs at T85 as compared with T40. This study shows that 99mTc-ECD SPECT can be used in cats for studying the rCBF and that the clearance of 99mTc-ECD in the feline brain is region dependent. As a result, the acquisition should be started between 40 and 60 minutes after tracer injection.  相似文献   

16.
OBJECTIVE: To determine maximum extrarenal plasma clearance of technetium-99m-mercaptoacetyltriglycine (99mTc-MAG3) and maximum extrarenal hepatic uptake of 99mTc-MAG3 in cats. ANIMALS: 6 clinically normal adult cats. PROCEDURES: Simultaneously, baseline plasma clearance and camera-based uptake of 99mTc-MAG3 were determined in anesthetized cats. Double exponential curves were fitted to plasma clearance data. Injected dose was divided by area under the curve and body weight to determine 99mTc-MAG3 clearance. Regions of interest were drawn around kidneys and liver, and percentage dose uptake was determined 1 to 3 minutes after injection. After bilateral nephrectomy, simultaneous extrarenal plasma clearance and camera-based hepatic uptake of 99mTc-MAG3 were evaluated in each cat. RESULTS: Mean +/- SD baseline plasma clearance and extrarenal clearance were 5.29 +/- 0.77 and 0.84 +/- 0.47 mL/min/kg, respectively. Mean extrarenal clearance (as a percentage of baseline plasma clearance) was 16.06 +/- 7.64%. For right, left, and both kidneys, mean percentage dose uptake was 9.42 +/- 2.58, 9.37 +/- 0.86, and 18.79 +/- 2.47%, respectively. Mean hepatic percentage dose uptake before and after nephrectomy was 12.95 +/- 0.93 and 21.47 +/- 2.00%, respectively. Mean percentage change of hepatic uptake after nephrectomy was 166.89 +/- 23.19%. CONCLUSIONS AND CLINICAL RELEVANCE: In cats, extrarenal clearance of 99mTc-MAG3 is higher than that of other species; therefore, 99mTc-MAG3 is not useful for estimation of renal function in felids. Evaluation of renal function in cats may be more accurate via camera-based versus plasma clearance-based methods because camera-based studies can discriminate specific organs.  相似文献   

17.
In this study, plasma time-activity curves of 99mTc-mebrofenin were used to quantify hepatic function in dogs before and after induction of hepatic damage using a hepatotoxic agent. Nine dogs were determined to be healthy on the basis of physical examination, laboratory data and hepatic imaging. Plasma samples were collected 1, 3, 5, 7, 9, 15, 20, 30, 40, 50, and 60 minutes following a peripheral venous injection of 111-222 MBq (3-6 mCi) of 99mTc-mebrofenin. The area under the plasma time-activity curve (AUC) was calculated using two different methods and compared to direct measurement of the hepatic extraction efficiency. First pass hepatic extraction efficiency of 99mTc-mebrofenin was calculated from differential equation analysis of a two-compartment model following mesenteric venous injection of the radiopharmaceutical. In 7 of the original 9 dogs and 2 additional healthy dogs, plasma clearance and hepatic extraction efficiency determination were repeated following induction of hepatic injury by thiacetarsamide (3 mg/kg IV twice daily for 1 day). In one additional dog, hepatic injury was induced using carbon tetrachloride (0.3 ml/kg IP). Plasma time-activity curves of 99mTc-mebrofenin had kinetics of a two compartment model. Area under the curve was highly correlated with hepatic extraction efficiency. The AUC integrated from 1-60 minutes (AUC60) had the best correlation with hepatic extraction efficiency (r2 = 0.978, p < 0.001). A formula for calculation of hepatic extraction efficiency was derived using linear regression analysis: hepatic extraction efficiency = 105.583 - 3.099 x 10(5) x AUC60. Plasma clearance of a peripheral venous injection of 99mTc-mebrofenin is a simple, non-invasive, convenient method to quantify hepatic function which can be performed without a gamma camera.  相似文献   

18.
Arai  T.  Hashimoto  K.  Muzutani  H.  Kawabata  T.  Sako  T.  Washizu  T. 《Veterinary research communications》1999,23(4):203-209
The plasma concentrations of fructose, glucose, free fatty acids (FFA) and triglycerides (TG) were measured in dogs and cats. Changes in these concentrations were investigated in dogs by an intravenous fructose tolerance test (IVFTT) at a dose of 0.1 g/kg body weight. Fructose concentrations in the plasma of dogs were significantly higher than those of cats. There was no significant difference in plasma glucose concentrations between dogs and cats. Plasma FFA concentrations decreased and TG concentrations increased after feeding in both dogs and cats. During the IVFTT, the plasma fructose concentrations in the dogs increased rapidly to a peak by 2 min and then decreased to half of the peak by 5 min after the administration of fructose. Administration of fructose resulted in an increase in the plasma TG concentrations and reduced plasma FFA concentrations in the dogs. Only 4% of the administered fructose was detected in the urine of dogs following IVFTT. Plasma fructose was considered to be rapidly absorbed and metabolized in both dogs and cats. However, as with glucose metabolism, there appear to be some differences in fructose metabolism between dogs and cats.  相似文献   

19.
Glomerular filtration rate (GFR) was determined in 53 cats using an inulin single-injection method. Thirty healthy young adult cats were used to establish normal values. The procedure was also used in 23 cats that were either older than 10 years or had borderline serum creatinine levels. The total clearance was calculated from the decay of the serum inulin concentration after injection of 3000 mg/m(2)body surface area using a two-compartment model. Concomitant inulin and iohexol clearance in nine cats showed excellent correlation between the two methods. Calculated normal values for GFR in 30 healthy cats were 35.9-58.5 (median 46.0) ml/min/m(2)or 2.07-3.69 (median 2.72) ml/min/kg. A few cats with normal creatinine or blood urea nitrogen levels were detected as having reduced GFR and therefore being in a state of early renal dysfunction. The study indicates that single-injection inulin clearance is a valuable tool for routine GFR measurement in cats. An "inulin excretion test" using only one blood sample 3h after the administration of 3000 mg/m(2)body surface area could prove an attractive alternative for the assessment of renal function in daily practice.  相似文献   

20.
Comparative pharmacokinetics of doxycycline in cats and dogs   总被引:3,自引:0,他引:3  
The disposition of doxycycline hyclate was studied in six adult mixed-breed female cats and six adult mid-sized female dogs following a single intravenous administration of 5 mg/kg body weight. Doxycycline volume of the central compartment, area volume of distribution, volume of distribution at steady state, and total body clearance were significantly smaller in cats. The differences were attributed to more extensive binding of doxycycline to plasma protein including albumin in cats. The significant differences in the volume of distribution and total body clearance were not reflected in elimination half-lives under the conditions of this study (sample size, inhomogeneous population). Doxycycline elimination half-life was 4.56 +/- 0.68 (SEM) h for cats and 6.99 +/- 1.09 h for dogs. Dosage regimens recommended in the veterinary literature were evaluated by the computer program PETDR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号