共查询到20条相似文献,搜索用时 15 毫秒
1.
William M. Adams DVM R. Tass Dueland DVM MS Ruth Daniels DVM James P. Fialkowski BS Erik V. Nordheim PhD 《Veterinary radiology & ultrasound》2000,41(6):484-490
Hip joint laxity was evaluated in Golden Retriever (n = 60), Labrador Retriever (n = 23), and Labrador/Golden Retriever mix (n = 24) puppies. Ortolani and Bardens maneuvers, four radiographic measurement indices and three dynamic ultrasonographic measurements were used. Each puppy was evaluated twice; at 6.5 to 9 and 43 to 79 weeks of age. These nine methods were compared for accuracy in predicting the development of canine hip dysplasia with or without degenerative joint disease by a median age of 16 months. The Bardens maneuver was a significant predictor of canine hip dysplasia/+/-degenerative joint disease for Golden Retriever puppies, however, it was not a reliable predictor for the other two breeds. Norberg angle measurements taken with femurs in a neutral position with hips distracted (PennHip position) was a significant predictor of degenerative joint disease in two breeds, but not in Golden Retriever puppies. Ultrasound measurement was a reliable predictor of hip canine hip dysplasia/+/-degenerative joint disease for Labrador/Golden Retriever mix puppies, but was not reliable for the other two breeds. Palpation, radiographic, and ultrasonographic methods of evaluating hip joint laxity in puppies at 6.5 to 9 weeks of age were not consistently reliable for all three breeds in predicting hip dysplasia with or without degenerative joint disease at one year of age. A strong association was found between Norberg angle and degenerative joint disease occurrence, as well as between distraction index (PennHip) and degenerative joint disease occurrence when measured at 52 to 79 weeks of age, but not when measured at 6.5 to 9 weeks of age in these breeds. These results emphasize the difficulty of early detection of mild hip dysplasia in the dog. 相似文献
2.
Raymond K. Henley DVM David A. Hager DVM Norman Ackerman DVM 《Veterinary radiology & ultrasound》1989,30(3):121-124
The detection of small amounts of free peritoneal fluid in the canine patient can be a diagnostic dilemma. Ultrasonography and radiography have been advocated to detect intraabdominal fluid not detectable by physical exam. The purpose of this study was to determine the more sensitive method for detecting small amounts of free peritoneal fluid. Ultrasound examinations and radiographs were performed after increments (1 ml/lb body weight) of fluid were injected intraperitoneally. Ultrasonography detected fluid in one animal at 2 ml/lb. AH other animals had fluid detected at 3 ml/lb. With radiographs fluid could be detected with a high degree of accuracy at 4 ml/lb. The lateral view was more accurate than the ventrodorsal view in detecting fluid. The authors concluded that Ultrasonography is more sensitive than radiography and is the method of choice to detect small amounts of free peritoneal fluid. 相似文献
3.
COMPARISON OF THORACIC ULTRASONOGRAPHY AND RADIOGRAPHY FOR THE DETECTION OF INDUCED SMALL VOLUME PNEUMOTHORAX IN THE HORSE 下载免费PDF全文
Jessica Partlow Florent David Luanne Michelle Hunt Fabien Relave Laurent Blond Manuel Pinilla Jean‐Pierre Lavoie 《Veterinary radiology & ultrasound》2017,58(3):354-360
Small volume pneumothorax can be challenging to diagnose in horses. The current standard method for diagnosis is standing thoracic radiography. We hypothesized that thoracic ultrasonography would be more sensitive. Objectives of this prospective, experimental study were to describe a thoracic ultrasound method for detection of small volume pneumothorax in horses and to compare results of radiography and ultrasound in a sample of horses with induced small volume pneumothorax. Six mature healthy horses were recruited for this study. For each horse, five 50 ml air boluses were sequentially introduced via a teat cannula into the pleural space. Lateral thoracic radiographs and standardized ultrasound (2D and M‐mode) examinations of both hemithoraces were performed following administration of each 50 ml air bolus. Radiographs and ultrasound images/videos were analyzed for detection of pneumothorax by four independent investigators who were unaware of treatment status. Sensitivity, specificity, positive predictive values, negative predictive values, and agreement among investigators (Kappa test, κ) were calculated for radiography, 2D and M‐mode ultrasound. Comparisons were made using a chi‐squared exact test with significance set at P < 0.05. Two‐dimensional (84%) and M‐mode (80%) ultrasound were more sensitive than radiography (48%) for pneumothorax detection (P = 0.02 and P = 0.04, respectively). Specificity and positive predictive values were similar for all three imaging modalities (P = 1). Agreement between investigators for pneumothorax detection was excellent for 2D ultrasound (κ = 1), very good for M‐mode ultrasound (κ = 0.87), and good for radiography (κ = 0.79). Findings from this experimental study supported the use of thoracic ultrasonography as a diagnostic method for detecting pneumothorax in horses. 相似文献
4.
VALERIE J. MOORMAN JOHN F. MARSHALL DUSTIN V. DEVINE MARK PAYTON HENRY W. JANN ROBERT BAHR 《Veterinary radiology & ultrasound》2009,50(6):577-583
Radiographic diagnosis of equine bone disease using digital radiography is prevalent in veterinary practice. However, the diagnostic quality of digital vs. conventional radiography has not been compared systematically. We hypothesized that digital radiography would be superior to film-screen radiography for detection of subtle lesions of the equine third metacarpal bone. Twenty-four third metacarpal bones were collected from horses euthanized for reasons other than orthopedic disease. Bones were dissected free of soft tissue and computed tomography was performed to ensure that no osseous abnormalities were present. Subtle osseous lesions were produced in the dorsal cortex of the third metacarpal bones, and the bones were radiographed in a soft tissue phantom using indirect digital and conventional radiography at standard exposures. Digital radiographs were printed onto film. Three Diplomates of the American College of Veterinary Radiology evaluated the radiographs for the presence or absence of a lesion. Receiver operator characteristic curves were constructed, and the area under these curves were compared to assess the ability of the digital and film-screen radiographic systems to detect lesions. The area under the ROC curves for film-screen and digital radiography were 0.87 and 0.90, respectively ( P =0.59). We concluded that the digital radiographic system was comparable to the film-screen system for detection of subtle lesions of the equine third metacarpal bone. 相似文献
5.
Leigh G. Griffiths MA VETMB DSAS MRCVS Martin Sullivan BVMS PHD DVR MRCVS Turlough O''Neill MVB MACVSC MRCVS Stewart W. J. Reid BVMS PHD. MRCVS 《Veterinary radiology & ultrasound》2003,44(2):210-213
The tympanic bullae of 20 previously healthy cadaver animals were randomly filled with sterile saline or air. The heads were positioned using tape ties and a rostrocaudal open mouth radiograph taken. The resulting radiographs were assessed by a blinded ECVDI diplomate, with each tympanic bulla being recorded as being either air or fluid filled. Ultrasound examination of the bullae was performed, by a blinded assessor, using a B-mode 5 mHz sector probe (Sonotron-VingMed Sound A/S, PO Box 141, N3191, Horten, Norway) operating at 3 mHz. Each bulla was recorded as being either air or fluid filled. Results of radiography and ultrasonography were each compared to the actual status of the bulla in a chi square analysis. Sensitivity of radiography was 80%, with specificity of 65%. Ultrasonographic sensitivity was 100% and specificity 100%. Ultrasonography may in future provide a cheap, noninvasive, rapid and widely available method for diagnosing otitis media in clinical cases. 相似文献
6.
Tanja Bindeus DVM Susanne Vrba Christine Gabler Thomas Rand Christian Stanek 《Veterinary radiology & ultrasound》2002,43(5):455-460
Major advantages of computed radiography are the potential reduction of dose and the possibility of postprocessing. In our study, we compared conventional radiographs to digital radiographs of the equine stifle by subjective evaluation of diagnostic quality when using a decreasing photon flux (mAs). Twelve equine stifle joints from horses of different weight and size were examined. Conventional and digital radiographs were performed identically in a caudocranial projection with the tube angled 15 degrees. A series of four radiographs was performed in each technique with an increasing photon flux starting with 2.5 mAs and going up to 5, 10, and 20 mAs. All radiographs were evaluated subjectively in a blinded fashion by seven readers in terms of contrast, bone structure, and diagnostic value and were graded using a 1-5 scale. Results from conventional and digitized radiographs were compared, and differences between the individual observers were analyzed statistically. Contrast, bone structure, and diagnostic value from digital images were rated significantly better than from conventional images (p < .001). For both techniques, a decrease in ranking was found with a decrease of photon flux. There was only slight interobserver variability. A dose reduction up to a factor of 4 compared to a 100 speed film-screen system seems to be possible without loss of information. Weight and size of the horse are not major influences. 相似文献
7.
猪白细胞抗原与产仔性能的关系 总被引:4,自引:2,他引:4
采用微量淋巴细胞毒试验对90头经产母猪(二花脸65头,大约克猪25头)进行了血清学分型,计算了单倍型在两品种中的分布频率,运用单因子和双因子最小二乘分析法分析了SLA单倍型与产活仔数之间的相关性。结果发现:(1)不同单倍型对猪产活仔数影响有明显的差异,H6、H10有明显的正效应,H2、H12、H31有负效应。(2)单倍型对产活仔数影响在品种间有差异,在太湖猪中H6、H7、H10和H23几种单倍型频 相似文献
8.
DIAGNOSTIC SENSITIVITY OF ULTRASOUND,RADIOGRAPHY AND COMPUTED TOMOGRAPHY FOR GENDER DETERMINATION IN FOUR SPECIES OF LIZARDS 下载免费PDF全文
Francesco Di Ianni Antonella Volta Igor Pelizzone Sabrina Manfredi Giacomo Gnudi Enrico Parmigiani 《Veterinary radiology & ultrasound》2015,56(1):40-45
Gender determination is frequently requested by reptile breeders, especially for species with poor or absent sexual dimorphism. The aims of the current study were to describe techniques and diagnostic sensitivities of ultrasound, radiography, and computed tomography for gender determination (identification of hemipenes) in four species of lizards. Nineteen lizards of known sex, belonging to four different species (Pogona vitticeps, Uromastyx aegyptia, Tiliqua scincoides, Gerrhosaurus major) were prospectively enrolled. With informed owner consent, ultrasound, noncontrast CT, contrast radiography, and contrast CT (with contrast medium administered into the cloaca) were performed in conscious animals. Imaging studies were reviewed by three different operators, each unaware of the gender of the animals and of the results of the other techniques. The lizard was classified as a male when hemipenes were identified. Nineteen lizards were included in the study, 10 females and nine males. The hemipenes were seen on ultrasound in only two male lizards, and appeared as oval hypoechoic structures. Radiographically, hemipenes filled with contrast medium appeared as spindle‐shaped opacities. Noncontrast CT identified hemipenes in only two lizards, and these appeared as spindle‐shaped kinked structures with hyperattenuating content consistent with smegma. Hemipenes were correctly identified in all nine males using contrast CT (accuracy of 100%). Accuracy of contrast radiography was excellent (94.7%). Accuracy of ultrasound and of noncontrast CT was poor (64.3% and 63.1%, respectively). Findings from the current study supported the use of contrast CT or contrast radiography for gender determination in lizards. 相似文献
9.
Jason T. Crawford DVM Paul A. Manley DVM William M. Adams DVM 《Veterinary radiology & ultrasound》2003,44(6):619-628
Thirteen dogs with fractures requiring surgical repair were evaluated by standard two-view (i.e., lateral and ventrodorsal) radiography, tangential view (ventro 20 degrees cranial-dorsocaudal [inlet] and ventro 20 degrees caudal-dorsocranial [outlet]) radiography, and computed tomography (CT). Radiographic and CT examinations were reviewed independently by the three authors, and specific anatomic sites were graded for the presence or possibility of lesions. The results of radiographic interpretations were compared to CT scan interpretations. Eighty-one percent of skeletal lesions detected by CT scans were diagnosed definitively radiographically. Differences between the interpretation of CT and radiographic examinations included abnormalities associated with soft-tissue structures (P < 0.0001), the sacroiliac joints (P = 0.02), and the acetabula (P = 0.04). Interpretation of the lateral/ventrodorsal and inlet/outlet radiographic series were not statistically different, although inlet views may be complimentary to the standard radiographic examination. Its use deserves further study. Reader variation was less on evaluation of CT examinations than radiographic examinations. CT multiplaner reformations and three-dimensional reconstructions were useful for surgical planning in seven dogs. CT scanning is superior to survey radiography in assessing skeletal and soft-tissue injuries in dogs with pelvic trauma, although all clinically significant surgical lesions were described accurately radiographically. Based on this small series, the routine CT examination of dogs with pelvic trauma may not be justifiable for diagnosis but may be advantageous for surgical planning, especially if acetabular fractures are suspected on radiographs. 相似文献
10.
BARBARA VANDEVELDE BERNADETTE VAN RYSSEN JIMMY H. SAUNDERS MARTIN KRAMER HENRI VAN BREE 《Veterinary radiology & ultrasound》2006,47(2):174-184
Osteochondrosis lesions in 29 shoulder joints (from 20 dogs) were evaluated with ultrasound (US) and the results were compared with survey radiography, arthrography, and arthroscopy. US was performed with a 7-12 MHz linear matrix transducer which was placed in cranio-caudal direction just distally to the acromion while the joint was adducted and maximally endorotated to visualize the caudal aspect of the humeral head. With US, the subchondral defect was completely visible in 21 joints and partially visible in 8 joints. The length of the subchondral defect measured on US was comparable with the length measured on survey radiographs. In two joints, the cartilage flap was mineralized and thus already visible on survey radiographs. The mineralized flap was visible on US as a straight hyperechoic line above the subchondral defect. In the other joints, survey radiographs could not assess the status of the articular cartilage. In 17 joints, the presence of a cartilage flap or cartilage fissuring was suspected based on the presence of a second hyperechoic line at the base of the subchondral defect, and this suspicion was confirmed by arthroscopic examination in 16 joints and also by arthrographic examination in 15 joints. One joint that was suspected of having a cartilage flap on US was normal on arthroscopy and arthrography. When US revealed only focal thickening of the anechoic cartilage layer (5 joints), the joints appeared normal on arthroscopic and arthrographic examination. Of the four joints where the subchondral defect was irregular and covered by heteroechogeneous material on US, arthroseopy revealed the presence of a lesion resembling chondromalacia in two joints, the presence of a small cartilage flap in one joint and the presence of scar tissue underneath the flap at the level of the subchondral defect in one joint. In conclusion, US is a helpful imaging modality in the identification of osteochondritic lesions in the canine shoulder joint. US also appears to be a satisfactory imaging tool for identifying lesions such as joint mice, joint effusion, and distinct new bone formation. 相似文献
11.
Vx2 carcinoma was induced in the rabbit kidney by percutaneous injection of a tumor-cell suspension. A focal renal mass similar in appearance to spontaneous renal carcinoma was produced. The mass could be detected with ultrasound as early as one week post injection, however it could not be identified until two weeks post injection using renal angiography and excretory urography. The renal tumor was recognized with ultrasound as an alteration in the cortical outline and obliteration of the renal medulla. A small amount of perirenal fluid was identified at two weeks. Intra-and extrarenal tumors were evident at three weeks with hypoechoic and anechoic areas evident within the large extrarenal mass observed four weeks post injection. Hypoechoic areas observed with ultrasound corresponded to areas of necrosis and hemorrhage while anechoic areas represented fluid accumulation within and around the tumor. Transplanted tumors were detected by ultrasound before they were evident on either the renal angiogram or excretory urogram. Ultrasound is useful as a screening procedure when renal tumor is suspected. 相似文献
12.
COMPARISON OF RADIOGRAPHY, MYELOGRAPHY AND COMPUTED TOMOGRAPHY FOR THE EVALUATION OF CANINE VERTEBRAL AND SPINAL CORD TUMORS IN SIXTEEN DOGS 总被引:1,自引:1,他引:1
Wm. Tod Drost DVM Nancy E. Love DVM Clifford R. Berry DVM 《Veterinary radiology & ultrasound》1996,37(1):28-33
Radiographic, myelographic and computed tomographic (CT) studies from sixteen dogs with histologically diagnosed vertebral or spinal cord neoplasia (seventeen lesions) were retrospectively evaluated. Radiographs were compared with CT images to evaluate vertebral bony changes (bone production, lysis or both). Myelographic and CT images were evaluated to separate lesions into one of three categories, extradural, intradural/extramedullary, or intramedullary. These findings were compared to histologic tumor type from surgical or necropsy samples. Histologically, seven lesions were vertebral tumors and were classified as extradural lesions; ten lesions were spinal cord tumors of which eight were classified as intradural/extramedullary and two as intramedullary. Using CT, the amount of bony change associated with extradural lesions was greater than or equal to the amount of bony change visualized using radiographs. Myelography more correctly differentiated between intradural/ extramedullary and intramedullary lesions than did CT, although three open diagnoses detracted from the CT results. This study suggests that when evaluating extradural lesions, the amount of bony change was better visualized using CT than survey radiographs. Myelography was better when compared to CT for classifying spinal cord lesions, however, standardization of the CT imaging protocol may help determine the specific clinical indications for using CT in dogs with suspected vertebral or spinal cord tumors. 相似文献
13.
Ralph C. Weichselbaum DVM Daniel A. Feeney DVM MS Carl R. Jessen DVM PhD Carl A. Osborne DVM PhD V. Dreytser MS J. Holte PhD 《Veterinary radiology & ultrasound》1999,40(4):386-400
Urocystoliths of 9 mineral types from 437 canine patients submitted to the University of Minnesota Urolith Bank were imaged in a urinary bladder phantom. Imaging techniques simulated were survey radiography, pneumocystography, double contrast cystography (two iodine concentrations) and real-time ultrasonography (3.5 MHz, 5.0 MHz, 7.5 MHz). Imaging techniques were compared for accuracy of urocystolith detection, accuracy of urocystolith enumeration, and tendencies for over or undercounting. Across urocystolith mineral types, the false negative rates (no urocystoliths detected in a given case) for survey radiographs range from 2 to 27%. Pneumocystographic techniques are one-half as likely to yield false negative results as are survey radiographic techniques. Underestimates of urocystolith numbers and false negatives are likely using 80 mg iodine/ml double contrast cystography because calcium-based urocystoliths are isopaque in this contrast medium dilution. The 200 mg iodine/ml double contrast cystographic techniques are unlikely to yield false negative diagnoses even for very small (< or = 1.0 mm) urocystoliths and is comparable to pneumocystography for detection and slightly better for enumeration. The likelihood of an ultrasonographic false negative for urocystoliths decreases with increasing MHz. Under optimal conditions using a 7.5 MHz mechanical sector transducer, the false negative rates were comparable to double contrast cystography, but rates increased notably with lower MHz transducers. 相似文献
14.
Andris J. Kaneps D.V.M. Ph.D Philip D. Koblik D.V.M. M.S. Dominique M. Freeman Ph.D.† Roy R. Pool D.V.M. Ph.D.‡ Timothy R. O'Brien D.V.M. Ph.D. 《Veterinary radiology & ultrasound》1995,36(6):467-477
The relative sensitivity of radiography, computed tomography, and magnetic resonance imaging for detecting palmar process fractures of the distal phalanx in foals was determined and the imaging findings were compared with histomorphologic evaluations of the palmar processes. Compared to radiography, computed tomography and magnetic resonance imaging did not improve the sensitivity for detection of palmar process fractures. Statistical agreement for palmar process fracture diagnosis was excellent among the three imaging modalities. Histomorphologic evaluations were more sensitive for diagnosis of palmar process fracture than any of the imaging modalities. Three-dimensional image reconstructions and volume measurements of distal phalanges and palmar process fracture fragments from computed tomography studies provided more complete anatomical information than radiography. Magnetic resonance imaging confirmed that the deep digital flexor tendon insertion on the distal phalanx is immediately axial to the site where palmar process fractures occur, and differentiated cartilage, bone, and soft tissue structures of the hoof. 相似文献
15.
To compare the radiographic and computed tomographic (CT) findings and to evaluate the sensitivity of radiography and CT for diagnosis of nasal aspergillosis in dogs, the radiographic and CT studies of 48 dogs with chronic nasal disease were reviewed separately. The radiographic and CT findings were recorded, and a diagnosis was made. The results obtained in the dogs with nasal aspergillosis (n = 25) were used. Based on definite aspergillosis as diagnosis, CT had a sensitivity of 88% and radiography of 72%. Considering definite and probable aspergillosis as equivalent, CT had a sensitivity of 92% and radiography of 84%. The sensitivity was higher in dogs with lesions affecting the entire nasal cavity and frontal sinus on at least one side (n = 20) with a sensitivity of 100% for CT and 90-95% for radiography than in dogs with lesions restricted to the nasal cavities (n = 5) where CT had a sensitivity of 60-80% and radiography of 0-40%. CT was superior to radiography for evaluation of the nasal cavities (mucosal thickening along the nasal bones, surrounding bone hyperostosis/lysis), frontal sinuses (mucosal thickening along the frontal bone, fluid/soft tissue, frontal bone hyperostosis/lysis), and differentiation between a cavitated-like or a mass-like process. This study suggests that CT is more sensitive than radiography for diagnosis of nasal aspergillosis in the dog because of a better demonstration of some changes suggestive of nasal aspergillosis. A diagnosis of a nasal aspergillosis restricted to the nasal cavities or associated with an FB is challenging, even with the use of CT. 相似文献
16.
MERJA R. LEINONEN MARJA R. RAEKALLIO OUTI M. VAINIO MIRJA O. RUOHONIEMI ROBERT T. O'BRIEN 《Veterinary radiology & ultrasound》2011,52(1):82-87
Contrast‐enhanced ultrasound can be used to quantify tissue perfusion based on region of interest (ROI) analysis. The effect of the location and size of the ROI on the obtained perfusion parameters has been described in phantom, ex vivo and in vivo studies. We assessed the effects of location and size of the ROI on perfusion parameters in the renal cortex of 10 healthy, anesthetized cats using Definity® contrast‐enhanced ultrasound to estimate the importance of the ROI on quantification of tissue perfusion with contrast‐enhanced ultrasound. Three separate sets of ROIs were placed in the renal cortex, varying in location, size or depth. There was a significant inverse association between increased depth or increased size of the ROI and peak intensity (P<0.05). There was no statistically significant difference in the peak intensity between the ROIs placed in a row in the near field cortex. There was no significant difference in the ROIs with regard to arrival time, time to peak intensity and wash‐in rate. When comparing two different ROIs in a patient with focal lesions, such as suspected neoplasia or infarction, the ROIs should always be placed at same depth and be as similar in size as possible. 相似文献
17.
JULIEN OLIVE MARC‐ANDRÉ D'ANJOU KATE ALEXANDER SHEILA LAVERTY CHRISTINE THEORET 《Veterinary radiology & ultrasound》2010,51(3):267-279
We compared the ability of 1.5 T magnetic resonance imaging (MRI), computed tomography (CT), and computed radiography (CR) to evaluate noncartilaginous structures of the equine metacarpophalangeal joint (MCP), and the association of imaging changes with gross cartilage damage in the context of osteoarthritis. Four CR projections, helical single‐slice CT, and MRI (T1‐weighted gradient recalled echo [GRE], T2*‐weighted GRE with fast imaging employing steady‐state acquisition [FIESTA], T2‐weighted fast spin echo with fat saturation, and spoiled gradient recalled echo with fat saturation [SPGR‐FS]) were performed on 20 racehorse cadaver forelimbs. Osteophytosis, synovial effusion, subchondral bone lysis and sclerosis, supracondylar lysis, joint fragments, bone marrow lesions, and collateral desmopathy were assessed with each modality. Interexaminer agreement was inferior to intraexaminer agreement and was generally moderate (i.e., 0.4<κ<0.6). Subchondral bone sclerosis scores using CT or MRI were correlated significantly with the reference quantitative CT technique used to assess bone mineral density (P<0.0001). Scores for subchondral lysis and osteophytosis were higher with MRI or CT vs. CR (P<0.0001). Although differences between modalities were noted, osteophytosis, subchondral sclerosis, and lysis as well as synovial effusion were all associated with the degree of cartilage damage and should be further evaluated as potential criteria to be included in a whole‐organ scoring system. This study highlights the capacity of MRI to evaluate noncartilaginous changes in the osteoarthritic equine MCP joint. 相似文献
18.
MONIKA BOCHMANN EBERHARD LUDEWIG MARIA‐ELISABETH KRAUTWALD‐JUNGHANNS MICHAEL PEES 《Veterinary radiology & ultrasound》2011,52(3):256-261
A conventional high‐resolution screen–film system was compared with a digital detector system. A total of 20 birds (14 pigeons and six psittacine birds) with an average body mass of 533 g were examined in dorsoventral as well as lateral projections. Digital radiographs were acquired with the same mAs as well as half the mAs used for the conventional radiographs. Three criteria and one overall assessment were defined for each of four anatomic regions and assessed by five veterinarians using a score system. Comparison of the ratings was done by visual grading analysis. For the majority of criteria, there was no significant difference regarding image quality between the digital and screen–film projections. However, for certain criteria the quality of the digital images was significantly superior. Using the same mAs as for the conventional radiographs, the humeral joint surfaces and the honeycomb structure of the lung were assessed as superior with the digital imaging system. The tracheal rings and the delineation of the trachea from the surrounding tissue were also superior with the digital system. Assessment of the trabecular structure of the humerus was superior when the full mAs was used compared with the reduced mAs. In conclusion the digital technique is equal or superior to the conventional screen–film high‐resolution system for pet birds of a medium size. With some limitations, a dose reduction is possible with the digital system. 相似文献
19.
Jennifer White John Gay Raelynn Farnsworth Matt Mickas KwangGi Kim John Mattoon 《Veterinary radiology & ultrasound》2014,55(4):428-434
A large amount of overlap exists in the B‐mode ultrasound appearance of normal and abnormal liver, spleen, and kidney tissues in cats. Therefore, invasive tissue sampling procedures remain the standard method for diagnosing diseases in these organs. The purpose of our study was to assess the feasibility of ultrasound elastography as a technique for improving noninvasive characterization of the feline liver, spleen, and kidneys. Elastography was performed on 10 unsedated, clinically healthy cats. Numeric (strain) values (0 = softest to 255 = firmest) assigned to color pixels within regions of interest resulted in median scores (interquartile ranges) of body wall, 207.50 (189.75–224.00); liver, 119.00 (105.00–138.25); spleen, 127.50 (121–00–142.00); right renal cortex, 83.50 (64.00–130.00); right renal near field, 125.50 (110.75–139.75); left renal cortex, 77.50 (52.00–116.25); and left renal near field, 126.00 (114.00–145.25). Strain values were not different between organs. Body wall median was the only significantly different value (P < 0.05). Strain ratio values of body wall:organ were as follows: liver, 1.76 (1.38–2.00); spleen, 1.68 (1.47–1.83); right renal cortex, 2.31 (1.61–3.15); right renal near field, 1.62 (1.41–2.01); left renal cortex, 2.66 (1.45–4.13); and left renal near field, 1.51 (1.29–1.89). Subjectively, hepatic and splenic parenchymal tissues were homogeneous in compressibility and similar in elasticity to one another. Renal cortical tissue was softer compared to medullary tissue. Findings indicated that ultrasound elastography is a feasible technique for objectively and subjectively characterizing the feline liver, spleen, and kidneys. Further research is needed in cats with confirmed diseases of these organs, to compare the diagnostic sensitivity of ultrasound elastography vs. B‐mode ultrasonography. 相似文献
20.
NICK A. HUGGONS ROBIN J. W. BELL SARAH M. PUCHALSKI 《Veterinary radiology & ultrasound》2011,52(1):53-60
We compared the information gained from computed tomography (CT) vs. radiography in horses with nonneoplastic disease of the mandible. We hypothesized that CT would provide additional diagnostic information. Medical records, radiographs, and CT images of horses with nonneoplastic mandibular disease evaluated between 1994 and 2008 were reviewed. Nineteen horses were identified; 11 had a tooth root abscess and related disease, four had a fracture of the teeth and/or mandible, and four had a nonneoplastic mass. Both CT images and radiographs allowed identification of diseased teeth that appeared clinically normal otherwise. CT allowed identification of teeth that were clinically affected but appeared normal radiographically. Parameters such as tooth pulp involvement, lamina dura destruction, presence of bone fragments, lingual and buccal mandibular bone periosteal reaction, and cortical bone destruction were more conspicuous with CT. Performing radiography and CT in horses with nonneoplastic mandibular disease provides a more complete evaluation than either technique alone. CT contributes additional information that could otherwise be overlooked with radiographs alone in horses with a mandibular fracture. CT provides ancillary information to radiographs in horses with dental infection or a nonneoplastic mass of the mandible. 相似文献