首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A single-dilution indirect solid-phase radioimmunoassay (IRIA) was developed for the detection of low levels of anti-pseudorabies immunoglobulin G in swine sera. The assay derived increased sensitivity from the use of a second amplifying antibody. The IRIA was examined for its stoichiometry, amplification by secondary antibody, advantage of a single-dilution assay vs an end-point titration, sensitivity, and specificity. The assay had a near linear dose-response relationship with positive sera (serum-neutralization titer less than or equal to 1:16) and lacked a dose response with negative sera. With addition of the secondary antibody, the IRIA was enhanced 8.5-fold in net specific binding, and the end-point titer was amplified 32-fold. The single-dilution assay was proved to be a feasible test, compared with end-point titration. Anti-pseudorabies virus titers were at least 128-fold higher by IRIA than those by serum-neutralization test. Evidence indicated that there may be minimal or no cross-reactivity of IRIA antigen with anti-infectious bovine rhinotracheitis sera. The single-dilution IRIA was a rapid and sensitive test for anti-pseudorabies virus immunoglobulin G in swine sera.  相似文献   

2.
Antibody to smooth Brucella abortus lipopolysaccharide antigen on the surface of polystyrene tubes was detected with peroxidase-labeled antibody against bovine immunoglobulin G. The enzyme-labeled antiglobulin test (ELAT) activity of samples was expressed in arbitrary units/0.01 ml by reference to a standard curve based on tests of dilutions of a positive serum pool. Reactions greater than 3.0 U/0.01 ml were classified positive because specificity at this level was 99.8% (417/418 samples correctly classified negative) with agglutination test-negative sera from 33 Brucella-free herds. Results of the ELAT were compared with results of agglutination tests and the complement-fixation test (CFT), using 430 sera from cattle in 7 infected herds. Activity of greater than 5.0 ELAT U/0.01 ml was detected in all 54 sera classified as positive (titer greater than 1:10) by the CFT, including 5 sera classified as negative by the tube agglutination test. Sera from 8 nonvaccinated cows in the infected herds reacted only by the ELAT, whereas reactions were obtained with 25 and 5 sera by only agglutination tests and the CFT, respectively. The ELAT and CFT results were in agreement for 25 of 26 sera from agglutination test-reactor cattle in herds of unknown status. Comparisons of milk ring and whey agglutination tests with the whey ELAT on 146 quarter samples from cows in an infected herd revealed no ELAT activity greater than or equal to 1.0 U/0.01 ml in the 73 samples considered negative by the 2 other tests. Samples (n = 47) that contained greater than or equal to 1.0 ELAT U/0.01 ml included all (n = 40) samples with milk ring or whey agglutination titers greater than or equal to 1:16 and greater than or equal to 32, respectively, and 7 samples that gave weaker reactions to the latter tests.  相似文献   

3.
A second generation competitive enzyme immunoassay (CELISA) for detection of bovine antibody to Brucella abortus was developed to eliminate reagent variables in the assay. This assay was different from earlier CELISA formats in that it used recombinant protein A and protein G immunoglobulin receptors (PAG), labelled with horseradish peroxidase, thus eliminating the requirement for polyclonal anti-mouse-enzyme conjugate for detection. This allowed standardization of the assay. The CELISA uses a monoclonal antibody specific for a common epitope of the O-polysaccharide (OPS) of smooth lipopolysaccharide (SLPS) derived from B. abortus S1119.3. This antibody did not react with PAG. This monoclonal antibody was used to compete with antibody in the bovine test serum to the smooth lipopolysaccharide (SLPS) antigen. Reaction of bovine antibody was then measured directly with the PAG enzyme conjugate. In this case, development of colour in the reaction indicated a positive reaction. The performance characteristics of the new CELISA, sensitivity, specificity and exclusion of antibody of B. abortus S19 vaccinated animals, were very similar to those of the classical CELISA and to the indirect enzyme immunoassay (IELISA) when using sera deemed positive by isolation of the bacterium, either from individual animals or from some animals on the premises. All sera were tested by the buffered antigen plate agglutination test (BPAT) and the complement fixation test (CFT). Only samples positive on both BPAT and CFT were considered as positive and only samples negative on both tests were used considered negative. Sufficient samples from cattle, swine, sheep and goats to validate the test were included based on OIE guidelines suggesting inclusion of a minimum of 300 positive and 1000 negative samples.  相似文献   

4.
为建立检测牛传染性鼻气管炎病毒(IBRV)血清抗体的阻断ELISA方法,本研究以经蔗糖密度梯度离心法纯化的IBRV作为免疫原制备1株单克隆抗体(MAb),命名为cp-1-1。经间接ELISA、IFA和western blot鉴定,该MAb与IBRV呈阳性反应,与牛病毒性腹泻病毒(BVDV)及牛副流感病毒3型(BPIV3)呈阴性反应,具有较强的特异性。质谱分析结果显示MAb cp-1-1识别的表位位于IBRV VP8蛋白。以纯化的IBRV作为包被抗原、MAb cp-1-1作为检测抗体,建立检测IBRV血清抗体的阻断ELISA方法。该检测方法的抗原包被量为0.89μg/孔,样品稀释度为12,检测抗体MAb量为1.3μg/孔,二抗稀释度为15000。利用50份IBRV抗体呈弱阳性的牛血清(中和抗体效价为14~116)作为标准参考血清,确定该检测方法的阻断率Cut Off值为52.06%,即阻断率高于52.06%时判为阳性,低于52.06%时判为阴性。阻断ELISA方法特异性试验显示仅IBRV阳性血清检测为阳性,而BVDV、BPIV3、牛腺病毒3型(BADV-3)和O型口蹄疫病毒(O-FMDV)阳性牛血清均检测为阴性,表明该方法具有较强的特异性;该方法可检测的最低中和抗体效价为14,与病毒中和试验的敏感性一致,表明该方法具有较高的敏感性;重复性试验显示该方法批内、批间变异系数均小于10%,显示较好的重复性。对130份现地牛血清检测结果显示,该方法与病毒中和试验的符合率为98.46%。用该方法对某牛场接种IBRV灭活疫苗的牛血清进行检测,抗体阳性率为99.51%(205/206)。另外,采用该方法对我国8个省(市、自治区)的801份牛血清进行检测,IBRV的抗体阳性率为41.6%(333/801)。本研究建立的阻断ELISA方法可以用于IBRV疫苗免疫监测和血清流行病学调查,为我国IBR的防控提供技术支持。  相似文献   

5.
Two sensitive serum neutralization (SN) tests for the detection of antibodies to bovine herpesvirus-1 (BHV-1) in bovine sera were evaluated. Both SN tests used a 24 h incubation of test sera with 100 CCID50 of BHV-1 before the addition of susceptible cells. The tests differed in the presence (C test) or absence (D test) of complement and were compared with a standard 1 h incubation SN test and the enzyme-linked immunosorbent assay (ELISA). Although the mean titer of the C test was twofold higher than the mean titer of the D test for 310 sera, the number of samples which were negative was not significantly different between tests. For 100 sera from herds with known reactors, which were negative in a 1 h incubation SN test, 32% tested positive in the C and D tests. Other investigations, including Western immunoblotting and radioimmune precipitation, suggest that the 24 h incubation tests produce some false positive results. In contrast, the 1 h incubation SN test and, to a much lesser extent, the ELISA appear to produce some false negative results. The C test was more sensitive than the D test for detecting an early immune response after experimental infection.  相似文献   

6.
Carbon immunoassay (CIA), a novel indirect rapid test for Toxoplasma antibody in sheep, was compared with indirect fluorescent antibody assay (IFA). CIA relies on the adherence of carbon particles of India-ink to rabbit immunoglobulin G.l Carbon labelled anti-sheep rabbit IgG was used for the detection of sheep antibody when attached to tachyzoites of Toxoplasma gondii. The result was read in an ordinary light microscope and there was a clearcut difference between negative and positive reactions. Out of a total of 97 sheep sera tested, 15 sera were negative in both tests and 12 were negative in CIA but showed low positive titres in IFA. The remaining 70 sera were positive in both tests but the titres were usually about 3 dilution steps lower when investigated with CIA as compared to IFA.  相似文献   

7.
An enzyme-linked immunosorbent assay (ELISA) was evaluated and compared in parallel with the standard complement fixation test (CFT) for the diagnosis of bovine subclinical paratuberculosis. Bovine sera preabsorbed with the mixture of Mycobacterium phlei and kaolin suspension were assayed for antibody activities to the crude protoplasmic antigen of Mycobacterium paratuberculosis in the ELISA. ELISA antibody titer was expressed as ELISA antibody index (EAI) value: EAI = (At-An)/(Ap-An), where At, Ap and An are the absorbance values of a 1:200 dilution of unknown test sera, a 1:400 dilution of positive control serum, and a 1:200 dilution of negative control serum. An EAI of 0.6 or greater was established as a reasonable cutoff point for a positive antibody titer by ELISA. Of the 156 sera from cattle with subclinical M. paratuberculosis-infection, 106 (67.9%) were positive by ELISA and 41 (26.3%) by CFT. Of the 3,880 sera from cattle in the herds which had no history or evidence of paratuberculosis, 3,875 (99.9%) were negative by ELISA, and 3,787 (97.6%) by CFT. Positive ELISA titers were detectable 1 to 5 months earlier than positive CFT titers in experimentally infected cattle, and 7 to 10 months earlier in naturally infected cattle. These results indicate that the ELISA should replace the CFT as the routine test of choice for the diagnosis of bovine paratuberculosis.  相似文献   

8.
An enzyme-linked immunosorbent assay was developed to detect bovine serum antibody to infectious bovine rhinotracheitis virus. The specificity of this assay in 304 bovine sera, collected from an infectious bovine rhinotracheitis virus-free herd, was 100%; in sera from 62 cattle inoculated with an intranasal vaccine, its diagnostic sensitivity was 27.4% at one month and 100% at six months, postvaccination. In 303 bovine sera with standard serum neutralizing antibody titers of greater than or equal to 1:2 it showed 100% sensitivity; and in 463 random diagnostic samples, comparative tests indicated that enzyme-linked immunosorbent assay detected more seropositive animals (61.6%) than the standard serum neutralizing test (49.9%). The enzyme-linked immunosorbent assay method was considered to be technically superior as a routine diagnostic test for the detection of infectious bovine rhinotracheitis viral antibody in bovine sera.  相似文献   

9.
Sera from two blood type B cats had strong isoagglutinating and isohemolyzing titers against blood type A erythrocytes. In order to determine the class of the immunoglobulins, sera from the cats were pooled, ammonium sulfate precipitated, and gel filtered using sepharose 6B to separate the immunoglobulins by molecular size. The immunoglobulin concentrate separated into two fractions. The initial part of the first fraction was shown in an ELISA to contain IgM and to be devoid of IgG by immunoelectrophoresis and to have agglutinating activity (a titer of 1:4 with a protein concentration of 0.8 mg/ml). Treating this fraction with the reducing agent dithiothreitol (DTT) eliminated agglutinating activity. The latter portion of the second column fraction was shown to contain IgG by immunoelectrophoresis, and to be devoid of IgM by ELISA. Agglutinating activity was also present in the second fraction (a titer of 1:2 with a protein concentration of 1.9 mg/ml); hemagglutinating activity was not decreased by DTT treatment. These studies show that the predominant anti-A isoagglutinating activity in pooled sera from two blood type B cats is IgM and that some isoagglutinin activity can be associated with IgG.  相似文献   

10.
The sera of cows inoculated with Brucella abortus have a characteristically high titer of immunoglobulin (Ig) G1 antibodies to a soluble brucella antigen compared with sera of noninoculated vaccinated cattle. Concentrations of antigen-specific IgG1 were greater than 10-fold higher than those for IgG2, even though total IgG2 concentrations were higher than total IgG1 concentrations. Increases in IgG1 antibodies to Brucella abortus soluble antigen were detected shortly after vaccination in those cows from which strain 19 was isolated and by 28 weeks in cows from which strain 2308 was isolated. Increases in specific antibodies were not paralleled by increases in either total IgG1 or total IgG2 concentrations. Rather, there was a 15-fold to greater than 200-fold increase in specific activity, with up to 16% of the IgG1 specific for the brucella antigen used in the assay. Thus, measurement of changes in total IgG1 concentrations is not a reliable method to identify brucellosis-associated anti-Brucella abortus soluble antigen activity. Only one cow in a panel of 10 selected for detailed study showed a false-positive IgG1 titer, whereas some serologic assays showed as many as 4 or 5 false-positives. Results of the complement-fixation test, among the battery of serologic tests used for detection of brucellosis, best agreed with the occurrence of increased IgG1 antibody levels.  相似文献   

11.
A competitive enzyme-linked immunosorbent assay (C-ELISA) using neutralizing monoclonal antibodies (MAbs) against Akabane virus (AKAV) was developed to detect antibodies to AKAV in cattle sera. The performance of the test using 7 different competitor MAbs was evaluated in sequential serum samples and sera from cattle infected with various bovine arboviruses. The dynamics of the antibody response expressed by percentage of inhibition (PI) in C-ELISA coincided with those of neutralizing antibody titers in sequential serum samples from 2 cattle experimentally infected with AKAV. The value of PI in C-ELISA for convalescent sera from cattle infected with arboviruses correlated with the neutralizing antibody titer to AKAV but was unaffected by the antibodies to other arboviruses. In the validation experiment of C-ELISA using 286 bovine sera previously examined for the AKAV antibody by serum neutralization (SN) test, the relative specificity of C-ELISA was more than 98%, whereas the relative sensitivities of individual MAbs ranged from 49% to 82.2%. Overall agreement between C-ELISA and the SN test varied from 72% to 90% depending on the MAb. These results suggest that the C-ELISA is acceptable as a rapid and specific method for detecting antibodies to AKAV and is a potential alternative to the SN test.  相似文献   

12.
An agar-gel immunodiffusion test was compared with other serological tests for detection of antibodies in the sera of 48 cattle vaccinated with Brucella abortus strain 19. Two hundred forty-two sera were tested over a 12 month period, and addition of positive reactions for each test resulted in totals of 170 for the card test, 74 for the standard tube-agglutination test, 71 for the 2-mercaptoethanol test, 64 for the dithiothreitol test and 22 for the agar-gel immunodiffusion test.  相似文献   

13.
An indirect enzyme-linked immunosorbent assay (I.ELISA) is described for detection of bovine serum antibody to epizootic hemorrhagic diseases of deer virus (EHDV). Serum samples, at a dilution of 1:200, were incubated with group-specific EHDV antigens, pre-adsorbed to microtiter plates. Bound antibodies were detected by a murine monoclonal antibody to bovine immunoglobulin (Ig)G1 (heavy-chain specific) conjugated with horseradish peroxidase. The performance of the I.ELISA in detecting antibodies to EHDV in sequential serum samples from calves experimentally infected with serotypes 1,2,3 and 4 was evaluated. The I.ELISA detected EHDV antibodies from 14 days postinfection when seroconversion by the standard agar gel immunodiffusion (AGID) test was also evident. The group-specific antibodies to EHDV increased exponentially during the first two to four weeks postinfection and remained relatively stable for about 12 months in some calves. Unlike observations with the AGID test, no reaction was seen in the I.ELISA between blue-tongue virus (BTV) antigen and sera from calves given a single dose of EHDV. The performance of the I.ELISA and AGID were compared using 3,135 AGID negative bovine field sera from herds in Ontario, Alberta and British Columbia and 130 AGID positive samples collected from cattle in 1987 and 1988 during and after outbreaks of EHD in the Okanagan Valley, British Columbia. The specificity and sensitivity of the assay relative to the AGID test were 99.3% and 91.5% respectively, with an overall agreement of 99.0% between the tests.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
应用ELISA方法对鄂西北地区35家标准化猪场282份血清进行猪圆环病毒2型抗体水平检测,间接监测猪圆环病毒2型感染情况。试验结果表明:送检血清中阳性者为207份,总体阳性率73.4%,阳性ELISA值正态分布于0.15~0.6,其中0.3~0.4分布最多,占阳性数的25.1%;送检猪场中未感染猪圆环病毒2型者占17.1%,感染猪圆环病毒2型的猪场占82.9%;通过对发病猪进行临床症状观察和病理剖检发现具有典型猪圆环病毒2型特征。   相似文献   

15.
Intrauterine inoculation of pony mares with the bacterium that is the causative agent of contagious equine metritis (CEM) resulted in clinical disease. A humoral immune response could be detected by agglutination and complement fixation (CF), and in some cases precipitating antibody was found by immunodiffusion tests. Agglutinating antibody was the most reliable serological indicator of overt infection and was detected in 8 of 28 mares after initial intrauterine inoculation of 3–4 × 105 bacteria. Seventy percent of mares given a second inoculation and all mares given a third inoculation of 3–4 × 105 bacteria produced detectable agglutinating antibody. Only two of five mares given the third inoculation developed detectable complement-fixing antibody. Only one mare showed evidence of reinfection after a second or third intrauterine inoculation. All of the mares given a single intrauterine inoculum of ≥ 8 × 108 bacteria produced agglutinating antibody 10 to 30 days postinoculation (DPI) and 86% gave a positive CF test 10 to 20 DPI. Only mares with an agglutination titer of 320 or more produced precipitating antibody. Sera were considered positive in agglutination tests if they were reactive at a dilution of greater than 4 and positive in CF tests if they were reactive at a dilution of 4 or greater.Pony serum frozen at ?70°C was anticomplementary (AC). Treatment at 56°C abolished AC activity and revealed enhancing or procomplementary activity with guinea pig complement. Procomplementary activity could be abolished by treatment of heated pony serum with formaldehyde, which increased CF titers ≥ threefold in weakly reactive sera.  相似文献   

16.
An enzyme linked immunosorbent assay (ELISA) and the agar gel immunodiffusion test with bovine leukosis virus glycoprotein as antigen (AGIDT-BLV gp) were further used to test 633 bovine sera for antibodies to BLV. Both tests detected the same number of sera positive (149) or negative (464) for antibodies. Nine sera were negative in the ELISA but found to be weakly positive (2 sera) or bending the control line (7) in the AGDT-BLV gp. On the other hand 11 sera were scored negative in the AGIDT-BLV gp but were weakly positive (9 sera), positive (1), and strongly positive (1) in the ELISA. Both tests are used routinely in this Institute as they complement each other, specially if sera with low antibody titers are under investigation. It is concluded that ELISA can fully replace radioimmunoassays in the serodiagnosis of enzootic bovine leukosis.  相似文献   

17.
An agglutination reaction, relatively coarse compared to that obtained with immune sera, was observed when Corynebacterium ovis cells were incubated with lamb sera collected before and after ingesting colostrum. The reaction did not appear to involve immunoglobulin since it was not affected by treatment of precolostral lamb serum with rivanol, mercaptoethanol or rabbit antisheep serum. IgM was detected in only three of 10 precolostral samples with agglutinating activity and immunofluorescence studies showed that it was not specific for C ovis. In view of the non-specific clumping factor, tests which detect antitoxin would be preferable for immune surveys in young lambs.  相似文献   

18.
A modified indirect fluorescent antibody test for the detection of serum antibodies to bovine respiratory syncytial virus was developed. The test made use of Terasaki plastic microtiter plates in which bovine respiratory syncytial virus (Saskatchewan strain) infected Georgia bovine kidney cells were grown and fixed in situ by a modified acetone fixation procedure. Evans blue dye was used as a counterstain to reduce nonspecific fluorescence. In a study of 986 field sera from a geographically broad cross-section of mature Ontario cattle, 95% of the samples were found to be positive at or above a 1:2 dilution. No seronegative regions, counties or herds were identified. When representative samples covering a range of indirect fluorescent antibody titers were further examined by a microtiter virus neutralization assay, a significant agreement was found between the two tests. Up to a fourfold decrease in titer was observed when antigen coated plates were stored at -70 degrees C for four months. The modified indirect fluorescent antibody test for bovine respiratory syncytial virus antibody detection proved to be a rapid, practical procedure for use in the diagnostic laboratory. This study confirms that bovine respiratory syncytial virus is widespread in the Ontario cattle population and that most mature cattle can be assumed to have been exposed to this virus.  相似文献   

19.
A reliable bovine viral diarrhea (BVD) viral antigen was prepared from BVD virus grown on Madin Darby bovine kidney (MDBK) cells by solubilizing the virus with detergent MEGA-10 (decanoyl-N-methylglucamide) followed by removal of hydrophobic proteins with Triton X-100 treatment. By these treatments, problems of high background associated with BVD viral antigen in the enzyme-linked immunosorbent assay (ELISA) were eliminated. With this new antigen, an ELISA was adapted to detect bovine serum antibody against BVD virus. The diagnostic specificity of the assay in 403 bovine sera collected from a BVD virus-free herd was 100%; in 296 bovine sera with serum neutralizing antibody titers of greater than or equal to 1:2, 289 sera were ELISA positive (relative sensitivity of 97.6%), two sera gave false negative reactions (0.7%) and five sera gave suspicious reactions (1.7%). These interpretations were based on positive/negative (P/N) ratio readings, i.e. a P/N ratio of less than 1.50, 1.50-1.99 and greater than or equal to 2.00 were interpreted as negative, suspicious and positive reactions, respectively. The ELISA results gave excellent agreement with serum neutralization in detecting both seropositive and seronegative animals (Kappa = 0.994). The ELISA assay was considered to be technically superior to the serum neutralization test for the routine detection of BVD viral antibody in bovine sera.  相似文献   

20.
Outer sheath antigen was prepared from Leptospira interrogans serovars pomona, sejroe and hardjo by treating the organisms with 1.0M NaC1 followed by 0.04% sodium dodecyl sulfate (SDS). Sodium dodecyl sulfate was removed from the SDS-protein complexes by the extraction of dodecyl sulfate anions as ion pairs with triethylammonium cations into an organic solvent. The outer sheath antigen was recovered from the organic solvent as a precipitate and used as the source of leptospiral enzyme-linked immunosorbent assay (ELISA) antigen. Utilizing this antigen, ELISA was adapted to detect bovine serum antibody to L. interrogans serovars pomona, sejroe and hardjo. The specificity of this assay in 344 bovine sera, which were negative in the microscopic agglutination test (MAT) for seven serovars, was 99.4%. In sera from 37 and 87 cattle which revealed MAT titers greater than or equal to 1:50 for L. interrogans serovars pomona and sejroe, the relative sensitivity of the test was 100%. The ELISA also showed a considerable degree of low level cross-reactivity with other serovars. Sixty-six (75.9%) out of 87 bovine sera which were MAT-positive (MAT titer of greater than or equal to 1:50) with serovars sejroe and hardjo only were ELISA positive with heterologous pomona antigen; 16 (43.2%) and six 16.2%) out of 37 bovine sera which were MAT positive MAT titer of greater than or equal to 1:50) with serovar pomona only were ELISA positive with heterologous sejroe and hardjo ELISA antigen respectively.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号