首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
AIM: To investigate the presence of surface-active phospholipid (SAPL, or surfactant) in equine tendon and tendon sheath fluid. METHODS: The left front flexor tendon and sheath were removed from five Thoroughbred horses. Phospholipid was extracted from tendon sheath fluid using Folch reagent and quantified using spectroscopy. Transmission electron microscopy (TEM) was used to observe the tendon surfaces. RESULTS: The presence of phospholipid (90.6 (SD 4.3) microg/ml) in tendon sheath fluid, plus the appearance of oligolamellar layers and lamellar bodies on the tendon surface were indicative of SAPL. CONCLUSIONS: Evidence of SAPL was found in equine tendon, and may have a similar lubricating function as reported for synovial joints. CLINICAL RELEVANCE: These findings may have important implications for normal tendon function and possible therapeutic adjuncts for tendon and tendon sheath injuries.  相似文献   

2.
Physical, biochemical, and cytologic properties of synovial fluid from digital flexor tendon sheaths of clinically normal horses were investigated. Tendon sheath fluid was pale yellow, clear, and did not clot. Volume of fluid within a tendon sheath varied minimally, with a mean of 2.11 ml. Total erythrocyte counts were higher than values observed in normal equine joint fluid, whereas values for total leukocyte count (770 +/- 73 cells/mm3), viscosity (6.05 +/- 0.58 cs), and protein concentration (7.87 +/- 0.03 mg/ml) were similar to those in joint fluid. Large mononuclear cells were the predominant synovial fluid cell type. Mean hyaluronic acid concentration (0.74 +/- 0.02 mg/ml) and mucinous precipitate quality were lower than values in joint fluid.  相似文献   

3.

Background

Longitudinal tears in the lateral aspect of the deep digital flexor tendon are the most common causes of pain localised to the equine digital flexor tendon sheath. However conventional ultrasonographic techniques provide limited information about acute lesions. Ultrasonographic contrast agents are newly developed materials that have contributed to advancement in human diagnostic imaging. They are currently approved for intravenous use in human and animal models. In this study we described intrathecal use in the horse. This study was undertaken to evaluate the reliability of standard and angle contrast-enhanced ultrasonography to detect and characterize surgically-induced longitudinal lesions in the deep digital flexor tendons.In this pilot study surgically-induced lesions were created in the lateral aspect of the deep digital flexor tendon within the digital flexor tendon sheath in 10 isolated equine limbs to generate a replicable model for naturally occurring lesions. Another 10 specimens were sham operated. All the limbs were examined ultrasonographically before and shortly after the intrasynovial injection of an ultrasound contrast agent containing stabilised microbubbles. The images were blindly evaluated to detect the ability to identify surgically-created lesions. The deep digital flexor tendons were dissected and a series of slices were obtained. The depth of longitudinal defects identified with contrast-enhanced ultrasound scans was compared to the real extent of the lesions measured in the corresponding gross tendon sections.

Results

Contrast-enhanced ultrasonography with both angle and standard approach provided a significant higher proportion of correct diagnoses compared to standard and angle contrast ultrasonography (p < 0.01). Contrast-enhanced ultrasonography reliably estimated the depth of surgically-induced longitudinal lesions in the deep digital flexor tendons.

Conclusion

Contrast-enhanced ultrasound of the digital flexor tendon sheath could be an effective tool to detect intrasynovial longitudinal tears of the deep digital flexor tendon, although an in vivo study is required to confirm these results for naturally occurring lesions.  相似文献   

4.
Cartilage oligomeric matrix protein (COMP) is a noncollagenous extracellular matrix protein found predominantly in cartilage, but also in tendon, ligament and meniscus. Studies in man have demonstrated that it may be used as a prognostic marker in rheumatoid arthritis and osteoarthritis. The present study investigated whether tendon injury contributes to serum and tendon sheath synovial fluid levels of COMP in horses. COMP levels, analysed by competitive ELISA, in the digital sheath synovial fluid were more than 10-fold higher than in the serum. Levels were significantly raised when tendon damage or sepsis was present within the tendon sheath but showed only mild, statistically insignificant, elevation in cases of tenosynovitis alone. COMP concentrations in serum were found to vary with age. Foals (age < or = 1 year) had significantly (P<0.001) higher levels in comparison to older control horses. Total COMP concentrations in an age-matched group with tendinitis were not significantly different from the control group. Measurements of COMP levels in tendon sheath synovial fluid are therefore useful in depicting processes in tendon tissue, while elevated serum levels are likely to be more representative of joint disease than tendinitis.  相似文献   

5.
Objectives: To evaluate digital flexor tendon sheath (DFTS) synovial fluid cartilage oligomeric matrix protein (COMP) concentrations as a molecular marker for intrathecal pathology. Study Design: Case control study. Animals: Horses (n=46) with DFTS tenosynovitis; 23 fresh cadaver horses. Methods: DFTS synovial fluid samples were collected from clinical cases with noninfected DFTS tenosynovitis and from control DFTS. Clinical and surgical findings were recorded, and dissection of control limbs was performed to confirm the DFTS to be grossly normal. Synovial fluid COMP was quantified using a homologous competitive inhibition ELISA. Results: Abnormalities were identified tenoscopically: intrathecal tendon/ligament tearing was identified in 37 cases and 9 had other lesions. In control horses, synovial fluid COMP was higher in younger horses. Clinical cases with intrathecal tendon/ligament tearing had higher synovial fluid COMP than either clinical cases with other lesions, or controls. In horses ≥5 years old, the sensitivity and specificity of the assay was high for diagnosing intrathecal tendon/ligament tearing. Conclusions: COMP concentrations in DFTS synovial fluid were significantly greater than those in normal horses with noninfected tenosynovitis caused by intrathecal tendon/ligament tearing, but not by other lesions.  相似文献   

6.
Objective— To describe a tenoscopic approach to the carpal sheath for desmotomy of the accessory ligament of the superficial digital flexor tendon. Study Design— The surgical procedure was developed with use of normal forelimbs from equine cadavers and experimental horses. Animals or Sample Population— Twelve equine cadaveric forelimbs, 4 forelimbs from 2 horses anesthetized for terminal surgical laboratories, and 10 forelimbs from five experimental horses were used. Methods— The limbs were positioned lateral side up with the carpus slightly flexed. After distention of the carpal sheath, a portal was made approximately 2 cm proximal to the distal radial physis for arthroscope insertion. An instrument portal was made approximately 0.2 cm proximal to the distal radial physis. After flexion of the limb to 90°, the accessory ligament of the superficial digital flexor tendon was palpated and desmotomy was performed. Cadaveric limbs were dissected to confirm complete desmotomy. Experimental horses were monitored for short- (perioperative) and long- (4 weeks) term postoperative complications. Results— A tenoscopic approach to the carpal sheath provided adequate surgical access to the accessory ligament of the superficial digital flexor tendon for desmotomy. Most of the accessory ligament of the superficial digital flexor tendon could be easily seen within the sheath, except for the proximal 2 cm that could be readily palpated and subsequently transected. Important technical considerations were location of the arthroscope portal, adequate sheath distention, limb flexion to 90°, and desmotomy location. It was beneficial, but apparently not essential, to avoid the proximal perforating vessel. Postoperatively, some horses had swelling but were not lame and had normal range of motion of the carpus. Conclusions— Desmotomy of the accessory ligament of the superficial digital flexor tendon could be performed by using a lateral tenoscopic approach to the carpal sheath. Clinical Relevance— Desmotomy of the accessory ligament of the superficial digital flexor tendon by using a tenoscopic approach to the carpal sheath is an alternative technique to the medial incisional approach.  相似文献   

7.
OBJECTIVE: To describe the ultrasonographic appearance of the normal and diseased biceps brachii tendon and its tendon sheath in dogs. STUDY DESIGN: A prospective clinical study. ANIMALS: One hundred twenty client-owned dogs. METHODS: In the first part of the study, the ultrasonographic appearance of the normal biceps brachii muscle and the surrounding soft tissue was determined in 27 healthy dogs. Standard views were described and established. In the second part, 120 dogs with suspected pathology of the biceps brachii muscle were examined ultrasonographically. Fifty-five of these dogs had no sonographic changes, and 65 dogs had sonographically detectable pathologic changes of the tendon or the tendon sheath or both. The mean age of the affected dogs was 3.7 years. The ratio of males to females was 1.95:1. Sedation or anesthesia of the dogs was required because of the extreme movements of the leg necessary for the examination. To achieve a perpendicular view of the tendon and the tendon sheath, the area of the shoulder joint was rotated outward and abducted as far as possible. Examination of the muscle-tendon apparatus of the biceps brachii muscle was divided into 4 main sections. RESULTS: Linear transducers (7.5-10 MHz) allowed the soft tissue structures to be easily visualized with ultrasonography. Pathologic changes of the tendon and tendon sheath were visualized sonographically by using high-frequency linear probes. Partial or complete tendon rupture, medial luxation of the tendon, corpora libera in the tendon sheath, and tenosynovitis were clearly shown. CONCLUSIONS: High-frequency ultrasonography using linear transducers allows the examiner to accurately define the pathologic changes in the region of the biceps brachii tendon in dogs. CLINICAL RELEVANCE: The use of sonography for diagnosis of disease processes of the tendon and tendon sheath of the biceps brachii muscle complements clinical and radiographic examination findings.  相似文献   

8.
Pre‐surgical investigation of digital flexor tendon sheath pathology remains challenging with current standard imaging techniques. The aim of this prospective, anatomical, pilot study was to describe the anatomy of the equine hind limb digital flexor tendon sheath using a combination of computed tomography (CT) and computed tomographic contrast tenography in clinically normal cadaver limbs. Ten pairs of hind limbs with no external abnormalities were examined from the level of the tarsometatarsal joint distally. Limbs initially underwent non‐contrast CT examination using 120 kVp, 300 mAs, and 1.5 mm slice thickness. Sixty millilitres of ioversol iodinated contrast media and saline (final concentration 100 mg/ml) were injected using a basilar sesamoidean approach. The computed tomographic contrast tenography examination was then repeated, before dissection of the specimens to compare gross and imaging findings. The combined CT and computed tomographic contrast tenography examinations provided excellent anatomical detail of intra‐thecal structures. The borders of the superficial and deep digital flexor tendons, and the manica flexoria were consistently identifiable in all limbs. Detailed anatomy including that of the mesotenons, two of which are previously undescribed, and the plantar annular ligament were also consistently identifiable. Dissection of all 10 pairs of limbs revealed there to be no pathology, in accordance with the imaging findings. In conclusion, the combination of CT and computed tomographic contrast tenography may be useful adjunctive diagnostic techniques to define digital flexor tendon sheath pathology prior to surgical exploration in horses.  相似文献   

9.
An abnormal digital flexor tendon sheath was present in the mid to lower metacarpal region in a horse. Positive contrast radiography showed that it communicated with the carpal synovial sheath but not with the digital synovial sheath. Cytological and physical analysis of fluid from the abnormal tendon sheath revealed that it was compatible with normal synovial fluid. This abnormal tendon sheath was probably a congenital anomaly.  相似文献   

10.
Sodium hyaluronate reduces adhesions after tendon repair in rodents and dogs, and has been used in limited clinical trials in people. To evaluate its effect on tendon healing and adhesion formation in horses and to compare these effects with those of a compound of similar visco-elastic properties, a study was performed in horses, using a model of collagenase injection in the flexor tendons within the digital sheath. Eight clinically normal horses were randomly allotted to 2 groups. Adhesion formation between the deep digital flexor tendon and the tendon sheath at the pastern region was induced in the forelimbs of all horses. Using tenoscopic control, a 20-gauge needle was inserted into the deep digital flexor tendon of horses under general anesthesia and 0.2 ml of collagenase (2.5 mg/ml) was injected. The procedure was repeated proximally at 2 other sites, spaced 1.5 cm apart. A biopsy forceps was introduced, and a 5-mm tendon defect was created at each injection site. Group-A horses had 120 mg of sodium hyaluronate (NaHA) gel injected into the tendon sheath of one limb. Group-B horses had methylcellulose gel injected at the same sites. The contralateral limbs of horses in both groups served as surgical, but noninjected, controls. Horses were euthanatized after 8 weeks of stall rest. Ultrasonographic evaluation revealed improved tendon healing after NaHa injection, but no difference in peritendinous adhesion formation. Tendon sheath fluid volume and hyaluronic acid (HA) content were greater in NaHA-treated limbs. Gross pathologic examination revealed considerably fewer and smaller adhesions when limbs were treated with NaHA. However, significant difference in pull-out strengths was not evident between NaHA-treated and control limbs. Histologically, the deep digital flexor tendon from the NaHA-treated limbs had reduced inflammatory cell infiltration, improved tendon structure, and less intratendinous hemorrhage. Treatment with methylcullulose had no significant effect on tendon healing, adhesion size, quantity, or strength or on the volume and composition of the tendon sheath fluid. Sodium hyaluronate, administered intrathecally, appears to have a pharmaceutically beneficial action in this collagenase-induced tendinitis and adhesion model in horses.  相似文献   

11.
OBJECTIVE: To determine the effect of intrathecal amikacin administration and repeated tenovaginocentesis on the total nucleated cell count (TNCC), total protein (TP) concentration and cytologic characteristics of synovial fluid of the equine digital flexor tendon sheath (DFTS). STUDY DESIGN: Randomized, cross-over experimental design. ANIMALS: Adult horses (n=8). METHODS: Synovial fluid was aseptically collected from the DFTS and either 1 mL amikacin sulfate (250 mg/mL) or lactated Ringer's solution (LRS) was injected into the DFTS. Serial synovial fluid samples were obtained at 0, 12, 24, 48, and 72 hours. The opposite treatment was administered to the contralateral DFTS after a washout period of 2 weeks. RESULTS: Treatment increased TP concentration, TNCC, percentage of neutrophils, and neutrophil counts from baseline levels. There was no difference between treatment of the DFTS with amikacin or LRS. Values peaked at 12-24 hours after the initial centesis and then declined toward baseline levels. CONCLUSIONS: Injection and repeat centesis of the normal DFTS with 250 mg amikacin or an equivalent volume of LRS resulted in mild increases in synovial fluid analytes from baseline. Synovial inflammation in this study was not accompanied by lameness at the walk and measured analytes returned toward baseline levels within 12-24 hours of first injection. CLINICAL RELEVANCE: The effect of tenovaginocentesis and intrathecal administration of amikacin or LRS on DFTS synovial fluid values are modest in most horses; however, some horses can develop marked increases in synovial fluid values that may be interpreted as sepsis.  相似文献   

12.
Abstract

CASE HISTORY: Three Thoroughbred horses, a 6-week-old filly (Case 1), a 15-year-old broodmare (Case 2) and a yearling filly (Case 3), sustained synovial sepsis secondary to trauma.

CLINICAL FINDINGS: Case 1 presented with a heel bulb laceration communicating with the distal interphalangeal joint. Arthroscopic lavage was performed and treatment commenced using systemic and local broad spectrum antimicrobial drugs. A pure growth of multi-drug-resistant (MDR) Enterococcus gallinarum was cultured from samples of synovium and joint fluid. Antimicrobial treatment was changed according to the susceptibility results. Response to treatment was poor and despite repeat arthroscopic lavage and intra-osseous regional perfusion of antimicrobials the filly was subject to euthanasia 24 days after the initial injury. Post-mortem examination confirmed septic synovitis, cartilage degeneration and osteomyelitis.

Case 2 sustained a full thickness wound to the carpus which was sharply debrided and closed. The wound dehisced with effusion within the tendon sheath. Drainage was established and treatment included systemic broad spectrum antimicrobials, topical lavage with povodine-iodine and manuka honey infusion. A mixed infection including MDR Enterococcus faecalis was cultured from the synovial fluid. Antebrachiocarpal joint effusion developed 21 days after initial injury and joint sepsis was confirmed. Arthroscopic lavage and tendon sheath debridement were performed, followed by treatment with systemic and local antimicrobials. The mare improved and was discharged. Three months later lameness recurred and corticosteroids were administered intra-articularly. The mare became non-weight bearing lame and was subject to euthanasia. Post-mortem examination confirmed joint sepsis of the antebrachiocarpal and intercarpal joint.

Case 3 presented with a complete articular open fracture of the tibial crest. Under general anaesthesia the fracture was stabilised and the wounds debrided and closed. Systemic broad-spectrum antimicrobials were administered. Six days later the wound dehisced and a bone fragment was removed. Three weeks post-surgery the wound deteriorated with a purulent discharge. Culture of the discharge revealed a mixed bacterial infection, including a MDR Enterococcus faecalis. Femoropatellar joint involvement was confirmed, and treatment included joint lavage, local and systemic antibiosis, and manuka honey instilled into the wound. The filly initially improved, and then deteriorated such that euthanasia was performed.

DIAGNOSIS: All three cases had synovial sepsis with MDR Enterococcus spp.

CLINICAL RELEVANCE: Increased awareness of MDR pathogens in equine wound infections is essential. Prompt diagnostic testing, appropriate therapy, infection control strategies and on-going monitoring and management are vital to limit the clinical impact of these organisms.  相似文献   

13.
Reasons for performing study: Hyperintense signal is sometimes observed in ligaments and tendons of the equine foot on standing magnetic resonance examination without associated changes in size and shape. In such cases, the presence of a true lesion or an artifact should be considered. A change in position of a ligament or tendon relative to the magnetic field can induce increased signal intensity due to the magic angle effect. Objectives: To assess if positional rotation of the foot in the solar plane could be responsible for artifactual changes in signal intensity in the collateral ligaments of the distal interphalangeal joint and in the deep digital flexor tendon. Methods: Six isolated equine feet were imaged with a standing equine magnetic resonance system in 9 different positions with different degrees of rotation in the solar plane. Results: Rotation of the limb induced a linear hyperintense signal on all feet at the palmar aspect of one of the lobes of the deep digital flexor tendon and at the dorsal aspect of the other lobe. Changes in signal intensity in the collateral ligaments of the distal interphalangeal joint occurred with rotation of the limb only in those feet where mediolateral hoof imbalance was present. Conclusions: The position and conformation of the foot influence the signal intensity in the deep digital flexor tendon and in the collateral ligaments of the distal interphalangeal joint. Potential relevance: The significance of increased signal intensity in the deep digital flexor tendon and in the collateral ligaments of the distal interphalangeal joint should be interpreted with regard to the position and the conformation of the foot.  相似文献   

14.
Reasons for performing the study: Highly prevalent superficial digital flexor tendon (SDFT) injury results in compromised tendon function through fibrosis and high frequency of re‐injury due to altered biomechanical function. This study investigated the consequences of SDF tendinopathy on limb mechanics in relation to the mechanical properties of injured tendon. Objectives: To develop and validate a noninvasive in vivo assessment of tendon mechanics to investigate the effect of recent SDFT injury on limb stiffness index, providing an objective method to assess quality of healing. Hypotheses: Limb stiffness index would reduce as a consequence of SDFT injury and progressively increase during tendon healing and correlate with in vitro mechanical properties of the respective SDFTs. Methods: Kinematic analysis was performed at walk in 10 horses that had sustained career‐ending SDFT injury. Stiffness index was derived from limb force recorded via a series of force plates and measurement of change in metacarpophalangeal joint angle using 3D motion analysis software. Horses were subjected to euthanasia 7 months after injury, the SDFTs removed and subjected to nondestructive in vitro mechanical testing. Results: Limb stiffness index was reduced following SDFT injury in comparison with the contralateral limb and increased during the convalescent period, approximating that of the contralateral limb by 7 months post injury. There was a significant positive correlation between in vivo limb stiffness index and in vitro SDFT stiffness. Clinical relevance: The ability to assess and monitor SDFT mechanical competence through limb stiffness measurement techniques in horses recovering from SDFT injury and the possibility of corroborating this with functional tendon healing may permit a more objective and accurate assessment of optimal tendon repair in the horse. This technique may be a useful method for assessing the efficacy of treatment regimens for tendinopathy and could be utilised to predict time to safe return to performance or re‐injury.  相似文献   

15.
OBJECTIVE: To evaluate the effects of recombinant human platelet-derived growth factor-BB (rhPDGF-BB) on the metabolic function and morphologic features of equine superficial digital flexor tendon (SDFT) in explant culture. Animals-6 euthanized horses (2 to 5 years old). METHODS: Forelimb SDFT explants were cultured for 6 days as untreated control specimens or treated with rhPDGF-BB (1, 10, 50, or 100 ng/mL of medium). Treatment effects on explant gene expression were evaluated via real-time PCR analysis of collagen type I, collagen type III, PDGF-A, and PDGF-B mRNA. Explants were assayed for total collagen, glycosaminoglycan, and DNA content; histologic changes were assessed via H and E staining and immunohistochemical localization of collagen types I and III. RESULTS: No morphologic or proliferative changes were detected in tendon explant sections. After high-dose rhPDGF-BB treatment, gene expression of collagen types I and III was increased and decreased, respectively. Expression of PDGF-A and PDGF-B mRNA was significantly increased at 24 hours, but later decreased to have few or negative autoinductive effects. Although PDGF gene expression waned after 48 hours of culture, collagen type I gene expression was significantly increased at 48 hours and reached peak value on day 6. Glycosaminoglycan and DNA content of explants were unchanged with rhPDGF-BB treatment. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggest that rhPDGF-BB use may be of benefit in the repair of equine tendon, particularly through induction of collagen type I mRNA. Positive autoinductive effects of PDGF-BB in equine SDFT explants were detected early following culture medium supplementation, but these diminished with time.  相似文献   

16.
REASONS FOR PERFORMING STUDY: Inflammation of the digital flexor tendon sheaths is a chronic and nebulous condition often unresponsive to medical and surgical treatment. OBJECTIVES: To evaluate the incidence of longitudinal tears (LT) as the underlying cause of chronic tenosynovitis and annular ligament constriction syndrome (ALCS) in warmblood horses. METHODS: The records of 25 horses with chronic tenosynovitis and ALCS in which tenoscopical inspection of the digital flexor tendon sheath (DFTS) was performed between 1999-2000 were reviewed. Of 25 horses, 17 were diagnosed with an LT in the deep digital flexor tendon (DDFT). All horses had a history of distension of the DFTS and/or signs of an ALCS. All cases presented typical signs of a chronic inflamed DFTS on ultrasonography and 11 horses showed ultrasonographic changes (echogenic material or an irregular outlining) at the lateral or medial border of the DDFT. The diagnosis of LTs of the DDFT was established in all cases by tenoscopy. Surgical treatment consisted of removal of the torn collagen fibrils using a mechanical resector and decompressing the fetlock canal by a transection of the palmar annular ligament (PAL) using a hook knife under tenoscopic control. RESULTS: Ten horses became sound and resumed their previous level of work, 3 horses remained lame, 4 horses returned to previous level of work but needed intrasynovial treatment of the DFTS and reduced competition frequency to remain sound. CONCLUSIONS: Horses presented with chronic inflamed DFTS and/or ALCS might suffer from LTs in the DDFT; however, the diagnosis cannot be established with absolute certainty using only ultrasonography. Longitudinal tears should be suspected if ultrasonographic changes are present lateral or medial to the border of the DDFT but tenoscopical examination of the tendon sheath is essential to establish an accurate diagnosis and an effective treatment. POTENTIAL RELEVANCE: The presence of these LTs might explain why some cases of chronic tenosynovitis of the digital flexor tendon sheath and/or ALCS do not respond on surgical transection of the PAL alone without tenoscopy.  相似文献   

17.
OBJECTIVE: To test the failure strength and energy of 2 bioabsorbable implants applied to transected deep digital flexor tendons (DDFT) from adult horses. STUDY DESIGN: Ex vivo biomechanical experiment. SAMPLE POPULATION: Twelve pairs of deep digital flexor tendons harvested from the forelimbs of fresh equine cadavers. METHODS: Poly-L-lactic acid tendon plates were custom manufactured for application to the cylindrical surface of an adult equine deep digital flexor tendon. Twelve pairs of DDFTs were transected 2 cm distal to the insertion of the distal check ligament of the deep digital flexor tendon. One tendon of each pair was randomly selected for repair with a biodegradable plate or a 3-loop pulley method. Size 2 polydioxanone suture was used in both repairs. Repairs were tested in tension to failure, with peak force (PF) and total energy (TE) at repair failure recorded in Newtons (N) and Joules (J), respectively. A paired t-test was used for statistical evaluation with a significant level set at P< or = .05. RESULTS: Mean+/-SD PF for failure of plated tendons (1507.08+/-184.34 N) was significantly greater than for sutured tendons (460.86+/-60.93 N). TE was also significantly greater for failure of plated tendons versus sutured tendons. CONCLUSIONS: Plate fixation of transected cadaver DDFTs appear to have superior immediate failure strength than 3-loop pulley repairs. CLINICAL RELEVANCE: Whereas in vivo testing is required, a bioabsorbable tendon plate may provide initial increased strength to support tendon healing and decrease external coaptation requirements.  相似文献   

18.
During endoscopy (tenoscopy) of the distal aspect of the equine digital flexor tendon sheath (DFTS), the digital manica flexoria can be visualized connecting the distal branches of the superficial digital flexor tendon. However, this structure has been inconsistently described and variably named in the veterinary literature. The objectives of this study were to describe the presence, configuration and variability of the digital manica flexoria in the equine distal limb. Dissection of 144 equine cadaveric limbs revealed the presence of this structure in all the feet, although different types and conformations were identified. In the forelimbs, a membranous digital manica flexoria predominated (94%; < 0.001), in particular a synovial bridge type (83%; < 0.001). In the hindlimbs, a tendinous digital manica flexoria predominated (93%; < 0.001), in particular the oblique‐crossing of tendinous bundles (61%; < 0.001). Passage dorsal to the digital manica flexoria towards the distal DFTS was only possible in 22 of the 144 limbs, all forelimbs. Clinicians should be aware of the intra‐ and inter‐individual anatomical variations of the digital manica flexoria to avoid misinterpretation during ultrasonographic and tenoscopic examinations of the DFTS.  相似文献   

19.
Although inflammatory activation of cytokines have been analyzed in various tissues, there have only been a few and as-yet-inconclusive studies on cytokines in equine tendons. In this study, the localizations of 4 cytokines (IL-1alpha, IL-1beta, TNFalpha and IFNgamma) in tendinocytes of the equine superficial digital flexor tendon (SDFT) were analyzed by the use of an immunohistochemical method. In inflamed tendons positive staining for all 4 cytokines antibodies were detected in endotedinieum cells and vascular epithelial cells. In contrast, negative or trace immunoreactions were obtained in many tendinocytes in the normal tendon. The variation in cellular immune responses depending on the kind of cytokine may reflect the physiological/pathological condition of the SDFT.  相似文献   

20.
OBJECTIVES: To define a portion of the nucleotide sequences of each of the 6 insulin-like growth factor (IGF) binding proteins (IGFBPs) in horses and describe patterns of messenger RNA (mRNA) and protein expression for IGFBPs in normal equine tendons. ANIMALS: 7 horses. PROCEDURE: Total RNA was extracted from the tensile region of normal superficial digital flexor tendons and reverse transcribed into complimentary DNA (cDNA). The cDNA was amplified via PCR, and products representing portions of each IGFBP were cloned and sequenced. Nucleotide sequences were used to deduce the amino acid sequences, and both nucleotide and predicted amino acid sequences were compared with those published for bovine, human, mouse, and ovine IGFBPs. Gene expression was quantitated by real-time PCR assay, and protein expression was evaluated by western ligand blot (WLB). RESULTS: Clones ranged in size from 262 to 522 bp and had high degrees of sequence homology with other mammalian species. Sequence homology was highest between bovine and equine IGFBPs (86% to 95%) and amongst the IGFBP-5 sequences from the various species (92% to 95%). Message for IGFBP-2 to -6, but not IGFBP-1, was expressed in normal tendon. Protein expression for IGFBP-2, -3, and -4 was detected byWLB in normal tendon and markedly increased in damaged tendons. CONCLUSIONS AND CLINICAL RELEVANCE: Results provide basic information and tools needed for further characterization of the role of the IGF system in tendon healing and may lead to the ability to potentiate the response of healing tendon to exogenous IGF-I via concurrent manipulation of IGFBPs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号