共查询到20条相似文献,搜索用时 15 毫秒
1.
A microplate indirect enzyme-linked immunosorbent assay (ELISA) for antibodies against reticuloendotheliosis virus (REV) was consistently more sensitive than indirect immunofluorescent-antibody tests. Limits of antibody detection were comparable to those obtained in virus neutralizations. Detection of REV-infected chickens long after infection and after immunofluorescent antibody has waned makes ELISA especially suitable for screening chicken flocks. 相似文献
2.
Detection of antibodies to Eperythrozoon ovis by the use of an enzyme-linked immunosorbent assay 总被引:4,自引:0,他引:4
Specific antibody to Eperythrozoon ovis was detected by an enzyme-linked immunosorbent assay (ELISA) in the sera of infected sheep. In the presence of parasite antigen, positive control serum showed a reaction approximately eight times that of negative serum. When compared to an immunofluorescent antibody test (IFAT), the ELISA was eight times more sensitive. Positive control sera gave a titre of 1:3200 by IFAT and 1:25,600 by ELISA. Through the use of a reference titration curve ELISA could be used as a semi-quantitative system to determine antibody levels in test sera. 相似文献
3.
Gonen L Strauss-Ayali D Shkap V Vincent-Johnson N Macintire DK Baneth G 《Veterinary parasitology》2004,122(2):131-139
Canine hepatozoonosis is a tick-borne protozoal disease caused in the Old World and South America by Hepatozoon canis. An enzyme-linked immunosorbent assay (ELISA) using purified H. canis gamont antigen was applied for the detection of antibodies reactive with H. canis. Evaluation of the ELISA with sera from naturally infected parasitemic dogs indicated that it was sensitive (86%), specific (97%), and comparable to the indirect fluorescent antibody test (IFAT) for the detection of H. canis antibodies. A variable degree of serologic cross-reactivity was found between sera from H. americanum-infected dogs and the H. canis antigen. Dogs experimentally infected with H. canis seroconverted 1-4 weeks post-infection (PI). Antibody levels peaked at 7-9 weeks PI and gradually declined thereafter remaining above the cut-off value until the conclusion of the study 7 months PI. The ELISA will be valuable for serological evaluation of dogs suspected of exposure to H. canis and for epidemiological studies. 相似文献
4.
5.
G Lussier D Gunette W R Shek J P Descteaux 《Canadian journal of veterinary research》1988,52(2):236-238
Enzyme-linked immunosorbent assay was used to detect serum antibodies to mouse thymic virus, a herpesvirus that causes thymic lesions and immunosuppression. Antibodies were detected in mice that had received single or multiple injections of the virus and were also found in mice housed in contact with the experimentally infected animals. By contrast, mice not exposed to mouse thymic virus or those inoculated with an uninfected thymus preparation remained seronegative. A serological survey of eight mouse colonies revealed one positive colony, confirmed by virus isolation. These results show that the test is sufficiently sensitive and specific to be used for routine screening of mice. 相似文献
6.
7.
An enzyme-linked immunosorbent assay with the recombinant merozoite protein as antigen for detection of antibodies to Eimeria necatrix 总被引:1,自引:0,他引:1
A cDNA library was constructed with Eimeria necatrix merozoite mRNA and immunologically screened by chicken sera against this parasite. One of the positive clones containing an insert of 879 nucleotides, pNP19, showed similarity to part of a published gene expressed in E. tenella merozoite by the homology search system. The inserted DNA was subcloned into baculovirus, and a 35-kD protein was expressed, purified, and used for the antigen in enzyme-linked immunosorbent assay (ELISA). Antibodies from the chickens vaccinated with the E. necatrix attenuated strain, Nn-P125, were detected from 14 days after vaccination by ELISA. The mean absorbance increased rapidly to a peak around 21 days after vaccination; thereafter, it began to decline. Even though some of the vaccinated chickens showed very low levels of antibody response to the recombinant protein 56 days after vaccination, they were protected against challenge with virulent strain of E. necatrix. The mean absorbances in sera from both vaccinated and nonvaccinated chickens highly increased 14 days after challenge. On the other hand, the antibody was not detected in ELISA when chickens were exposed to other Eimeria species such as E. tenella, E. acervulina, and E. maxima. These results demonstrate that this recombinant protein is suitable for detecting the specific antibody in chickens infected with both attenuated and virulent strains of E. necatrix. 相似文献
8.
S A Fiscus M M Mildbrand J C Gordon Y A Teramoto S Winston 《American journal of veterinary research》1985,46(4):859-863
A rapid screening assay for determining antibodies to canine parvovirus in dog serum using monoclonal antibodies and enzyme-linked immunosorbent assay (ELISA) technology was developed. The ELISA could be read visually, and the results correlated well with serum neutralization (SN) and hemagglutination inhibition (HI) titers. Sera with SN less than or equal to 1:4 or HI less than or equal to 1:10 had an 87.9% correlation with ELISA and sera with SN greater than or equal to 1:64 or HI greater than or equal to 1:80 had a 94.4% correlation. The assay took only 10 to 15 minutes to perform and did not require specialized equipment. The ELISA should be useful in monitoring dogs for the presence of maternal antibodies against parvovirus and for determining seroconversion after vaccination. 相似文献
9.
Noormohammadi AH Browning GF Cowling PJ O'Rourke D Whithear KG Markham PF 《Avian diseases》2002,46(2):405-411
Mycoplasma gallisepticum is a poultry pathogen that causes respiratory disease and loss of egg production worldwide. A live attenuated vaccine, ts-11, has been used for control of M. gallisepticum in several countries. The rapid serum agglutination test is usually used as an indicator of flock response to vaccination; however, in some flocks, the detected response may be weak or absent. With the use of specific monoclonal antibodies against M. gallisepticum strain S6 pMGA in immunoaffinity purification, the major membrane antigen of ts-11 was purified. An indirect enzyme-linked immunosorbent assay (ELISA) was developed with the purified antigen, and its potential for detection of antibodies induced after ts-11 vaccination was compared with an indirect ELISA with M. gallisepticum strain S6 pMGA. In the presence of high levels of ts-11-induced antibodies, both antigens detected similar numbers of positive sera. However, when lower levels of antibodies were present, ts-11 pMGA showed a higher sensitivity than S6 pMGA. Further examination of ts-11 pMGA with Mycoplasma synoviae-infected chicken sera revealed that ts-11 pMGA is specific for M. gallisepticum antibodies. With a panel of sera from ts-11-vaccinated or non-ts-11-vaccinated field chickens, the ts-11 pMGA ELISA was found to be more sensitive than the commercial rapid serum agglutination test in detecting antibodies to ts-11 vaccine. The results from this study suggest that the major membrane antigen of M. gallisepticum may have slightly different antigenic profiles in different strains, thereby necessitating the use of autologous antigens in serodiagnostic assays to increase sensitivity of the tests for mycoplasma antibodies. Thus, the low level of antibody response after ts-11 vaccination is, at least partially, due to the low ability of the current diagnostic antigens to bind ts-11 antibodies. 相似文献
10.
Detection and quantification of antibodies to infectious bronchitis virus by enzyme-linked immunosorbent assay 总被引:3,自引:0,他引:3
An enzyme-linked immunosorbent assay (ELISA) for detecting and quantifying antibodies to infectious bronchitis virus (IBV) is described. Purified antigen, prepared on sucrose density gradients, was required to decrease the nonspecific background, and saline was found to be superior to bicarbonate buffer for coating the cuvettes with antigen. The sensitivity of the test in measuring antiserum titers could be altered greatly and linearly by adjusting the protein content of the antigen. The ELISA was able to detect an antibody response to IBV infection earlier than the virus-neutralization (VN) test. Antibody titers obtained by ELISA were considerably higher than those obtained by VN. Serotypes of IBV could not be differentiated with ELISA because of extensive antiserum cross-reactivity. The utility of ELISA in studies on IBV is discussed. 相似文献
11.
Salimi-Bejestani MR Daniel R Cripps P Felstead S Williams DJ 《Veterinary parasitology》2007,149(3-4):290-293
Antibodies against Fasciola hepatica were detected in serum and individual milk samples of dairy cattle using an ELISA. Percentage positivity (PP) values in milk samples were related to serum PP values and were not influenced by days into lactation. The correlation coefficient between serum and individual milk samples was highly significant (r=0.84, P<0.005). The correlation coefficient between herd seroprevalence and herd milk antibody prevalence was 0.96. The correlation coefficient between prevalence measured by faecal egg count and both seroprevalence and milk antibody prevalence within the herd was 0.87. The diagnostic sensitivity and specificity for milk were 92% (95% CI=89-96) and 88% (95% CI=85-91), respectively, when the serum test was considered as a gold standard. In conclusion, the level of antibody to F. hepatica in milk is significantly correlated with the antibody level in serum and this ELISA is suitable as a means of routine veterinary diagnosis of exposure to F. hepatica in cattle and an alternative to testing sera. 相似文献
12.
R.G. Dhawedkar N.C. Jain M.E. Mount A.T. Bowling J.L. Vegad 《Research in veterinary science》1991,51(3):292
An enzyme-linked immunosorbent assay (elisa) was standardised and applied for the detection of anti-platelet and antineutrophil antibodies using a heterologous system consisting of equine platelets or neutrophils and antisera raised in rabbits. The standardised technique consisted of using Immulon type 3 plate, I per cent gelatine as a blocking solution, poly-L-lysine buffer as a coating solution, unfixed antigen, 90 μl test serum, horseradish peroxidase conjugated antibody and o-phenylenediamine dihydrochloride as a substrate. The number of unfixed platelets or neutrophils required for optimum detection of antibodies was 250,000 per well. Unfixed cellular antigens were as good as their extracts and superior to paraformaldehyde-fixed antigens in detecting specific antibodies. Microtitre plates coated with platelet or neutrophil antigens could be stored at 4° and −70°C for four to five weeks without significant loss of antigenicity. The ELISA was very sensitive in that antiplatelet antibody was detected up to a titre of 1:204,800 and antineutrophil antibody to a titre of 1:51,200. Some cross-reactivity (1:1600) was detected in antiplatelet and antineutrophil sera for neutrophil and platelet antigens, respectively. Platelet-associated antibody was also detected in extracts from platelets pretreated with 1:2 and 1:8 dilutions of antiplatelet serum. Standardised elisa detected antiplatelet antibodies in nine and antineutrophil antibodies in three of 100 isologous equine blood typing sera. 相似文献
13.
A 2-stage strategy was developed and evaluated for estimating serum antibody titer by use of ELISA and a series of dilutions. In stage 1, the linear response region and least-square estimate of the assay line slope were established from 9-point dilution assays. Provided that the reading was within the linear response region, this information was used in the stage-2 estimation of titer from a single absorbance reading. Operationally, 2 fixed dilutions were selected, one suitably low and one suitably high, to provide at least one reading within the linear region. The procedure should save considerable time when a large number of assays are to be performed. Stage 1 required approximately twenty 9-point assays, but all subsequent assays required only 2 fixed dilutions. 相似文献
14.
An enzyme-linked immunosorbent assay for detecting antibodies to Pasteurella multocida in chickens 总被引:2,自引:0,他引:2
An enzyme-linked immunosorbent assay (ELISA) was developed to detect the humoral antibody response in chickens receiving subcutaneous injections of the CU vaccine strain of Pasteurella multocida. Serum samples were collected twice weekly for 3 weeks, and chicken antibody responses were monitored using ELISA. The positive/negative ratio method of analysis was used to determine the antibody titer of vaccinated chickens. After a loge transformation of the ELISA titer, a linear relationship was confirmed between ELISA titer and positive/negative ratio. Regression analysis was used to construct a standard curve and derive an equation from this relationship. Using this equation, only one dilution was needed to determine the antibody titer of any unknown serum sample. The ELISA technique was used to monitor the mean antibody titer of vaccinated chickens over the 3-week period. A classic primary response curve occurred when titer was plotted against time. 相似文献
15.
This paper describes an enzyme-linked immunosorbent assay (ELISA) for the diagnosis of cryptosporidiosis. A monoclonal antibody with a high affinity against an oocyst antigen was used to set up the test. The efficiency of this assay was compared with that of the flotation test; 275 calf faecal samples were examined by the two methods. There was 96% agreement between the two tests. For the 11 conflicting samples, the two tests were repeated and a modified Ziehl-Neelsen staining was performed on faecal smears. All these 11 samples contained few oocysts, but only five and six of them were shown to be positive by the ELISA and flotation tests, respectively. The degree of sensitivity of the ELISA and flotation tests is comparable; samples heavily or moderately contaminated with oocytes are detected by both methods. This ELISA is reliable and never gives rise to false positive results. Nevertheless, as with the flotation test, the occasional case containing very few oocysts will not always be detected by this test. If necessary, very accurate diagnosis can be made by a staining technique or by a direct immunofluorescent assay. In veterinary medicine, the ELISA seems to be a method of choice; it appears to be a fast and reliable technique which could be used as a routine test for the detection of Cryptosporidium oocysts. Nevertheless the degree of sensitivity must always be borne in mind. There is no need for a microscopic examination, which is an additional advantage. 相似文献
16.
S. T. de Echaide I. E. Echaide A. B. Gaido A. J. Mangold C. I. Lugaresi V. R. Vanzini A. A. Guglielmone 《Preventive veterinary medicine》1995,24(4):277-283
The sensitivity and specificity of an enzyme-linked immunosorbent assay (ELISA) to detect antibodies; to Babesia bovis was evaluated in 1000 sera from Holstein heifers. Five hundred of them were from cattle naturally or experimentally infected with B. bovis and 500 from uninfected heifers born and raised in a region free of the vector of cattle babesiosis. Additionally, the ELISA was evaluated and compared with an indirect immunofluorescent antibody (IFA) test in 374 heifers inoculated with different kinds of B. bovis antigens in four trials. The cross-reaction was also evaluated in 50 heifers infected with Babesia bigemina and 50 heifers infected with Anaplasma marginale. The mean percentage positivity of negative sera in relation to the ELISA strong positive sera was 8%. The seropositive/seronegative cutoff point was set as twice the mean percentage positivity of negative cattle sera ( = 16%). The sensitivity of the ELISA was 98% with a 95% confidence interval (CI) of 96–99%. The specificity was 95% (CI 93–97%). The agreement was 97% and the kappa value was 0.93. The predictive values of positive and negative results were 95% and 98% respectively. ELISA showed a similar sensitivity to that of the IFA test to detect antibodies to different B. bovis antigens. Its sensitivity ranged from 97.1% to 100% (CI 89–100%), while the sensitivity of the IFA test ranged from 92.8% to 100% (CI 83–100%). ELISA cross-reacted in 8% and 6% of the sera carrying B. bigemina and A. marginale antibodies, respectively, while the IFA showed 4% cross-reaction in each situation. The ELISA evaluated has the advantages of a proper sensitivity, objectivity and capacity to be adapted to test large number of samples in a short period of time. The results indicate that the ELISA is a suitable replacement for the IFA test to detect B. bovis antibodies in cattle sera, especially in epidemiological studies. 相似文献
17.
K M Beale R E Halliwell C L Chen 《Journal of the American Veterinary Medical Association》1990,196(5):745-748
Antithyroglobulin antibody (ATA) values were higher in dogs with low total serum thyroxine (T4) and triiodothyronine (T3) values than in dogs with T3 and T4 values within reference value limits. In the population studied, Doberman Pinschers were predisposed to the development of ATA; there was no sex predilection for development of ATA. Antithyroglobulin antibodies and thyroid status were evaluated in 2 groups of healthy dogs (n = 30) and in 470 canine serum samples submitted for T3 and T4 value determination. Antithyroglobulin antibodies were evaluated by ELISA, and thyroid status was evaluated by measurement of total serum T3 and T4 by radioimmunoassay. 相似文献
18.
Rapid detection of viral-specific antibodies by enzyme-linked immunosorbent assay (ELISA) 总被引:2,自引:0,他引:2
S Winston S Fiscus L Hesterberg T Matsushita M Mildbrand J Porter Y Teramoto 《Veterinary immunology and immunopathology》1987,17(1-4):453-464
The development of three separate rapid ELISAs for detecting antibodies in host serum to three different viruses is described. These include: 1. A direct antigen assay using enzyme labelled anti-canine Ig for detecting antibodies to canine parvovirus, 2. A competitive ELISA using a feline infectious peritonitis virus-specific monoclonal antibody labelled with enzyme, and 3. A competitive ELISA using an equine infectious anemia virus-specific monoclonal antibody and enzyme labelled antigen, p. 26. The utility and benefits of each of the three approaches is emphasized. 相似文献
19.
Detection of antibodies against Akabane virus in bovine sera by enzyme-linked immunosorbent assay 总被引:5,自引:0,他引:5
S Ide K Baba M Tsuchimoto H Nagano Y Eiguchi T Yamagami H Yamagishi Y Tanaka Y Fujisaki T Hohdatsu 《Veterinary microbiology》1989,20(3):275-280
An enzyme-linked immunonosorbent assay was established for detection of antibodies to Akabane virus in bovine sera. The assay was shown to be a useful serological tool for studies on Akabane virus infection. 相似文献
20.
An enzyme-linked immunosorbent assay (ELISA) was compared to an indirect immunofluorescence assay (IFA) for detection of IgG antibodies to Borrelia burgdorferi in dog sera. The concordance of the two tests was 93.5% for sera from dogs from Maryland (n = 93), 98.0% for sera from dogs from North Carolina (n = 446), and 97.2% for the combined sample groups (n = 539). Twenty-five of the 27 samples with discordant or low positive results were tested, and showed immunoblot reactions to 1 to 10 different bands. Reaction patterns and intensity of the bands were quite variable, and did not explain a reason for the discordance. 相似文献