首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
An 8-week-old female Patagonian cavy was examined because of acute right hind limb lameness; radiography revealed a moderately displaced, comminuted fracture of the proximal third of the tibia. The fracture was stabilized with a hybrid external skeletal fixator. Two Kirschner wires were placed in the main proximal fragment, parallel to the tibial plateau and at right angles to each other. These wires were connected to a partial circular external fixator ring. Three half pins were placed in the distal fragment, and a straight connecting rod positioned on the medial side of the limb was connected to these pins and the fixator ring. A second connecting rod was positioned on the craniomedial side of the limb and was connected to the fixator ring and a fourth half pin in the distal fragment. The fracture healed without complications, and the fixator was removed 3 weeks after surgery. Hybrid external skeletal fixators combine the benefits of circular and linear external skeletal fixation methods, enabling rigid fixation of periarticular long bone fractures without adversely affecting mobility of the adjacent joint.  相似文献   

2.
The study was undertaken to evaluate the feasibility of a simple, inexpensive model of circular external fixator (CEF) for use in large ruminants. A simple model of CEF frames consisting of four full rings (13-19 cm diameter, 4 cm wide and 4 mm thick with 18-24 holes) connected by threaded rods (8 mm diameter, 10-15 cm long) and nuts was developed using mild (low carbon) steel and were nickel-plated. In the first phase of the study, three male cow calves were utilized to study the feasibility of application of the fixators in the metatarsus, tibia and radius, in reference of adaptation and tolerance by animals. In the second phase, the fixators were tested in osteotomized bones. Six bull calves of 1.5-2 years of age weighing about 200-250 kg were utilized for this purpose. After preparing the area for aseptic surgery, under xylazine (at 0.1 mg/kg, i.m.)-ketamine (i.v. till effect) general anaesthesia, the test bone (metatarsus, radius and tibia in two animals each) was approached through the medial surface and an osteotomy was created with a saw and chisel at the mid-diaphysis. The pre-constructed 4-ring CEF was mounted on the limb around the test bone in such a way that it formed a cylinder with the axis of the limb at the centre. Each ring was then fixed to the bone with a pair of beaded wires (316 SS) of 3.5 mm diameter. During the post-operative period, the animals were observed for any change in behaviour, tolerance of the fixators, the weight bearing on the test limb, the status of the fixator, and the level of reduction of the osteotomy, alignment and healing at different intervals. The fixation of CEF was easier in the metatarsus and radius than in the tibia. The inner ring diameters found adequate for metatarsus, radius and tibia were 13-15 cm, 15-17 cm and 17-19 cm, respectively. The fixators applied to different bones were well-tolerated, and the animals could lay down, stand and walk freely with the fixator without any problems. All the animals showed good weight bearing in the immediate post-operative period. Weight bearing, however, slightly reduced in the inflammatory period and showed improvement after about 4 weeks. Wire tract infection was seen in all the animals, which was more on proximal wire tracts on lateral aspect of limbs. Circular fixators were well-tolerated by all the animals, and there was no breaking/bending of connecting rods, slotted bolts or the rings at any stage of observation. Slight bowing of some wires was noticed in cases of tibia and radius (in phase II) and bending of some wires was noticed from first week in two animals one each in radius and tibia. Bone fragments were well maintained until healing occurred (appearance of bridging periosteal callus) at 60-70 days. The functional results were good in all but one case of tibia, where a mal-union was recorded. From this study, it can be concluded that CEF are well-tolerated by large ruminants and can be used to treat long bone fractures. The fixator assembly using mild steel is sufficiently strong to maintain fracture fixation and is inexpensive. The simple design of the CEF appears to be sufficient to treat simple diaphyseal fractures of the metatarsus and radius. Improvement in the technique of fixation and design-like coupling of linear and circular fixator components into hybrid constructs may help to provide greater rigidity in treating tibial and open long bone fractures.  相似文献   

3.
旨在评估普通T形骨板内固定治疗玩具犬桡尺骨远端骨折的临床效果及并发症。回顾了在中国农业大学动物医院采用开放式复位和普通T形骨板内固定治疗桡尺骨远端骨折的玩具犬的病历记录,并对这些病例进行回访。入选病例满足:体重不超过7 kg;骨折位置位于前臂远端(远端骨段与桡骨长度比值<0.25);回访时间>12个月;病例信息记录完整。结果表明:共纳入29只犬的29例桡尺骨远端骨折,26例(89.7%)术后无跛行,3例(10.3%)术后勉强可见跛行。未发生严重并发症,轻微并发症的发生率是20.7%(n=6)。普通T形骨板内固定能有效治疗玩具犬桡尺骨远端骨折,临床效果良好,无严重并发症。  相似文献   

4.
Metacarpal fractures were more common than metatarsal fractures in this retrospective study of 37 dogs. Fractures of one metacarpal or metatarsal bone occurred In 24 per cent of the dogs, two metacarpal bones in 16 per cent, three metacarpal or metatarsal bones in 19 per cent, and four metacarpal or metatarsal bones in 41 per cent. Eighty-seven per cent of the dogs with fractures of four bones had fracture displacement or malalignment of at least one digit. Progressive fracture healing usually occurred Irrespective of stabilisation method. For malaligned fractures, however, external coaptation did not consistently improve alignment. Fracture alignment was consistently Improved by open reduction and internal fixation of acute fractures with bone plates. Fractures of four bones occurred most often In the distal metacarpus as opposed to the proximal metatarsus. Therefore, open reduction and internal fixation may be more commonly indicated for severe metacarpal fractures, because fracture displacement or axial1 malalignment was significantly associated with fractures of the mid or distal regions of the metacarpus or metatarsus (P=0.052).  相似文献   

5.
Objectives: To report the repair of tibial diaphyseal fractures in 2 calves using a circular external skeletal fixator (CEF). Study Design: Clinical report. Animals: Crossbred calves (n=2; age: 6 months; weight: 55 and 60 kg). Methods: Mid‐diaphyseal tibial fractures were repaired by the use of a 4‐ring CEF (made of aluminum rings with 2 mm K‐wires) alone in 1 calf and in combination with hemicerclage wiring in 1 calf. Results: Both calves had good weight bearing with moderate lameness postoperatively. Fracture healing occurred by day 60 in 1 calf and by day 30 in calf 2. The CEF was well maintained and tolerated by both calves through fracture healing. Joint mobility and limb usage improved gradually after CEF removal. Conclusions: CEF provided a stable fixation of tibial fractures and healing within 60 days and functional recovery within 90 days. Clinical Relevance: CEF can be safely and successfully used for the management of selected tibial fractures in calves.  相似文献   

6.
Three immature cats with growth abnormalities of the distal radius secondary to trauma were presented between July 2001 and July 2003. Initial injuries included a Salter-Harris type II fracture of the distal radial physis in one cat, fractures of the styloid process of the ulna in two cats, and metacarpal fractures in one cat. The cats were between 3.5 and 4.5 months of age at the time of injury. Damage to the distal radial physis resulted in a variable degree of shortening of the radius in all cats. Asymmetrical closure caused widening of the lateral aspect of the radiocarpal joint space in two cats. Elbow incongruity was not observed. One cat was treated with osteotomies of the radius and ulna and realignment of the radius, stabilised with external skeletal fixation. Another was treated by ulnar ostectomy alone. Radius and ulna osteotomies and distraction osteogenesis of the radius were performed in the third cat. Clinical outcome was satisfactory in all three cases.  相似文献   

7.
An 8-year-old male Boxer with a severely contaminated open fracture of the left radius and ulna fracture, produced by a helicopter propeller, was treated using bone transport by the Ilizarov method. Extensive diaphyseal bone loss and soft-tissue vascular damage were present. The radius and ulna were stabilised with an Ilizarov ring external fixator. The bone defect was partially shortened and restored by gradual transport of a bone segment created from proximal segments of the radius and ulna. The external fixator was removed 4 fi months after the beginning of the latency period, due to instability caused by osteolysis around the wires. A cast was placed for 3 weeks. Although the bone transport had resulted in formation of approximately 4 cm of bone, the antebrachium showed approximately 50% shortening when compared to the contralateral limb. The infection was eradicated, and the dog was able to bear weight on the operated limb when walking.  相似文献   

8.
Fractures of the radius and ulna are common in the dog and cat. If treated inappropriately, complications may result. These include delayed union, nonunion, malunion, and growth deformities. ESF is a versatile method of fixation for fractures of the radius and ulna. Types that are applicable range from the simple type I to the complex type III fixator. In general, the more unstable the fracture, the more rigid the assembly must be to counteract fracture forces. There are three basic phases to consider when using ESF: (1) preoperative planning, (2) application of the ESF, and (3) long-term management. A deficiency in any one of these phases can lead to complications and an unsatisfactory clinical outcome. Although ESF can be used on many types of fractures, the technique is especially well suited for open or highly comminuted fractures when internal fixation is not applicable. In these cases, close attention must be paid to the integrity of the soft tissues. In addition, cancellous bone grafts should be placed either at the time of initial repair or in a delayed fashion after adequate vascularity has been established. Staged or complete removal of the ESF should be individualized to each fracture case. In general, staged disassembly or "dynamization" can begin when the bone and fixator begin to function as a composite as determined by radiographs. Complete fixator removal should be considered when the fracture exhibits clinical and radiographic evidences of union.  相似文献   

9.
Methods of treating fractures of the olecranon in the horse are reviewed. A further 4 cases are recorded in which the fracture was treated by open reduction and fixation with a heavy duty Venable's plate placed on the caudal aspect of the ulna. Three cases had an oblique fracture through the semilunar notch; this was complicated in one by a fracture of the lateral half of the radial head which resulted in subluxation of the radio-humeral joint. The fracture of the radial head was treated by open reduction and fixation with a lag screw. The fourth case had an oblique fracture of the olecranon just proximal to the semilunar notch, complicated by a fracture of the anconeal process which was removed. The fractures healed within 10 weeks and the plates were removed in all 4 cases. During follow-up periods ranging from 10 to 26 months, all 4 animals became sound.  相似文献   

10.
Repair of a comminuted fracture of the proximal portion of the radius and ulna in a 4-month-old llama was achieved by use of internal fixation. An 8-hole narrow dynamic compression plate was applied to the lateral aspect of the radius and a 7-hole narrow dynamic compression plate was applied to the cranial aspect of the radius. One year after surgery, the llama had a normal gait and the cosmetic appearance of the limb was excellent.  相似文献   

11.
Multiple intramedullary wire fixation infrequently can be used as an alternative technique to plating, transfixation devices, single intramedullary pinning, or external coaptation for some radius and ulna fractures.
This report describes a comminuted fracture of the radius and ulna with fissures and comminution extending too far into the proximal radius for effective application of a bone plate or Kirschner-Ehmer apparatus. Resulting fracture instability and collapse prohibited effective use of external coaptation as a primary means of fixation. The radial fracture was repaired and stabilized with full cerclage wires and multiple intramedullary Kirschner wires. The dog was using the leg normally 12 months following surgery.  相似文献   

12.
Case histories of 130 dogs and cats with humeral fractures were reviewed. The different types of fractures were classified. Most animals with proximal, shaft, and supracondylar fractures had excellent results. The poor prognosis associated with distal articular fractures was due most often to failure of the fixation device in the supracondylar area; best results were achieved with a plate on the caudal and medial surface of the distal humerus.  相似文献   

13.
Twenty-five cases of fractures of the second and fourth metacarpal and metatarsal (splint) bones were reviewed. Fourteen fractures involved a thoracic limb and 11 involved a pelvic limb. Fractures of the proximal one-third of splint bones are reported in one of two forms: fractures that are closed, or fractures with a permanent or intermittent draining sinus. Thirteen of the fractures presented were closed fractures and the remaining 12 were open. All of the closed fractures were managed by surgical excision of the distal fragment and the exostosis at the fracture site, followed by primary surgical wound closure. Lag screw fixation of the proximal fragment was used in three cases. All of the open fractures were managed surgically by excision of the distal splint fragment and debridement of the contaminated fracture site. Primary wound closure was used in 11 of the 12 cases. All closed fractures healed by primary intention, and 10 of 13 were free from lameness at one year follow-up. The 11 open wounds which were operated and subsequently closed under suture healed by primary intention. The wound left open healed by granulation, scar contraction, and epithelialisation. Eight of these horses were sound one year later. The remainder of the open fractures were lost to follow-up.  相似文献   

14.
An 8-year-old American Quarter Horse gelding was evaluated because of an open fracture involving the left radius. The horse had fallen during training and became immediately non-weight-bearing in the left forelimb. On initial evaluation, the horse was unable to bear weight on that limb; radiography revealed a long oblique fracture of the distal metaphysis of the radius with minimal displacement of the fracture fragments. Because of the configuration of the fracture, we recommended surgical intervention with internal fixation. A condylar screw implant and 4.5-mm broad dynamic compression plate were applied to the medial and dorsolateral aspects of the radius, respectively. The horse recovered in a sling and full-limb bandage. Six months after discharge, the horse was reevaluated because of a grade 4/5 lameness in the same limb. Palpation revealed signs of severe pain over the distomedial aspect of the radius. Radiography of the left radius revealed severe osteolysis beneath the distal aspect of the condylar screw implant. Surgical removal of the medial plate was performed. Sixteen months after the initial fracture repair, the horse had returned to light training without signs of lameness. Removal of the dorsal plate may be indicated if this horse is to return to aggressive training or becomes lame in the left forelimb.  相似文献   

15.
A 6-month-old female crossbred dog with unilateral radial hemimelia was treated with a circular external fixator. During the first surgery, the dog underwent transverse osteotomy through the distal ulnar physis and rotation of the distal ulnar fragment (epiphysis) together with the forepaw in a lateral direction to achieve contact with the end of the proximal ulnar segment (shaft of the ulna); a circular external fixator was then applied. After removal of the fixator, a cast was applied. The initial intent was to preserve mobility of the ulnocarpal joint; however, the joint fused naturally. A second surgery was performed to lengthen the ulna by use of distraction osteogenesis. An Ilizarov external fixator was used, and the ulna was lengthened 25 mm. During the third surgery, osteotomy of the distal portion of the ulna was performed to treat residual deviation of the forepaw. The surgical treatment resulted in satisfactory use of the limb and a better quality of life.  相似文献   

16.
Fractures of the distal radius in two horses were repaired by open reduction and interfragmentary compression using screws placed in a lag fashion. One horse had a complete oblique fracture of the medial aspect of the epiphysis of the distal radius and was sound for riding 32 months after surgery. The other horse had an open spiral comminuted fracture with medial displacement of the distal radial fragment. Laminitis developed in the contralateral limb and this horse was euthanatized 5 weeks after surgery. © Copyright 1994 by The American College of Veterinary Surgeons  相似文献   

17.
Objective— To describe a lateral approach for screw fixation in lag fashion of simple spiral medial condylar fractures of the third metacarpus/metatarsus (MC3/MT3).
Study Design— Case series.
Animals— Thoroughbred racehorses (n=9).
Methods— Nondisplaced medial MC3/MT3 condylar fractures (3 thoracic, 6 pelvic limbs), with mean length 126 mm (range, 91–151 mm) were repaired by internal fixation, under general anesthesia, using multiple 4.5 mm cortical screws inserted in lag fashion from the lateral aspect of the limb, using radiographic or fluoroscopic guidance. Horses were recovered from anesthesia in half-limb casts; 7 unassisted and 2 using a rope-recovery system. Horses had 2 months box rest, 1 month in-hand walking, and follow-up radiographic examination at 3 months.
Results— Horses recovered uneventfully from anesthesia. Five horses raced; 1 returned to training, was persistently lame, and was retired to stud; 2 were retired directly to stud; and 1 horse was lost to follow-up.
Conclusions— MC3/MT3 medial condylar fractures were successfully repaired by screws inserted n lag fashion form the lateral aspect.
Clinical Relevance— Use of a lateral approach to medial condylar MC3/MT3 fractures allows screw insertion perpendicular to the fracture plane without interference with palmar/plantar soft tissue structures or from the splint bones. Although repair was performed under general anesthesia, the technique should be adaptable to application in standing horses.  相似文献   

18.
OBJECTIVE: To determine treatment and outcome of a series of wapiti (elk) with fractures of the limbs. DESIGN: Retrospective study. ANIMALS: 22 wapiti. PROCEDURE: Medical records were reviewed to determine affected limb and bone, fracture configuration, method of treatment, outcome, and complications. RESULTS: 2 animals had fractures of the humerus; 8 had fractures of the radius, ulna, or both; 5 had fractures of the third metacarpal bone; 3 had fractures of the tibia; 2 had fractures of the femur; and 2 had fractures of the tarsal bones. Most fractures (n = 11) were closed, displaced, nonarticular fractures; 6 fractures were open. Four animals died or were euthanatized prior to fracture treatment, 2 were not treated because fractures had already healed, and 14 underwent fracture repair. In the remaining 2 animals, the affected limb was amputated. Five animals developed nonfatal complications (wound dehiscence, osteomyelitis [2 animals], delayed union, and malunion) and 2 developed fatal complications (gastrocnemius rupture and femoral fracture during recovery). Overall, 16 animals were discharged from the hospital, and all were doing well at follow-up, 2 months to 4 years after discharge. CLINICAL IMPLICATIONS: In wapiti, limb fractures can be successfully treated by means of internal or external fixation. The high rate of fracture healing, even among wapiti with open fractures, should encourage veterinarians to repair limb fractures in wapiti.  相似文献   

19.
Bone plate fixation was reviewed in 29 distal radial fractures of small- and miniature-breed dogs. Twenty-two fractures in 18 dogs were available for follow-up. Number of complications and return to function were evaluated. Complications occurred in 54% of the fractures. Catastrophic complications occurred in 18% of fracture repairs with follow-up, while minor complications occurred in 36%. Sixteen (89%) of 18 dogs had a successful return to function. Bone plate fixation is a successful repair method for distal radius and ulna fractures in small-breed dogs, compared to previously reported methods.  相似文献   

20.
An adult llama and four alpacas were referred with long bone fractures. The llama presented with a closed, comminuted fracture of the right metatarsal bones. Two of the alpacas presented with comminuted fractures of the proximal radius. One fracture was closed and one was open. One alpaca had a closed, comminuted fracture of the distal radius, and the final alpaca had a closed, oblique fracture of the metatarsus. A diagnosis was made in each animal on the basis of clinical examination and radiographs. All fractures were managed by open reduction and internal fixation using selective placement of lag screws and dynamic compression plates. Four animals made uneventful recoveries and no long-term complications were encountered. One alpaca was re-admitted for plate failure and non-union of the fracture 5 weeks after surgery. The plate and screws were removed and a transfixation cast was applied. The fracture healed, however the alpaca showed signs of radial nerve paralysis after the cast was removed. With confinement in a small yard, full function gradually returned to the leg over the ensuing 4 months. Using techniques recommended in other species, South American camelids are suitable candidates for long bone fracture repair using open reduction and internal fixation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号