首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The objective of this study was to define the patterns of organogenesis and foetal haemodynamics during the normal gestation of healthy agoutis (Dasyprocta prymnolopha) kept in captivity. Thirty pregnant agoutis that ranged in size from small to medium and weighed between 2.5 and 3 kg underwent B‐mode and Doppler ultrasonography for the biometric evaluation of the foetal organs. The foetal aortic blood flow proved to be predominantly systolic, and the measured flow velocity was 78.89 ± 2.95 cm/s, with a maximum pressure gradient of 2.12 ± 0.27 mmHg. The liver was characterized by its large volume, occupying the entire cranial aspect of the abdominal cavity, and it was associated cranially with the diaphragm and caudally with the stomach. The flow velocity in the portal vein was estimated to equal 12.17 ± 2.37 cm/s, with a resistivity index of 0.82 ± 0.05. The gallbladder was centrally located and protruded cranially towards the diaphragm. The spleen was visualized as an elongated structure with tapered cranial and caudal extremities, and the foetal kidneys were visualized bilaterally in the retroperitoneal region, with the right kidney positioned slightly more cranially than the left. The morphological characterization and hemodynamic analysis of the foetal organs of black‐rumped agoutis via B‐mode and Doppler ultrasonography allow determination of the vascular network and of reference values for the blood flow required for perfusing the anatomical elements essential for maintaining the viability of foetuses at different gestational ages.  相似文献   

2.
The objectives of the study were to evaluate haemodynamic changes and their relationships among ipsilateral (IPS) and contralateral (CONT) uterine arteries (UA) during different stages of pregnancy in Bos indicus cows. Multiparous pregnant cows (n = 40) having a gestation length 30.47 ± 0.54 (mean ± SD) days were randomly enrolled and subjected to Doppler ultrasonography sequentially at 1st, 2nd, 4th, 6th and 8th months of gestation. Blood flow indices including diameter of UA (mm), blood flow volume (BFVo, ml/min), blood flow velocity (BFVe, cm/s), time-averaged maximum velocity (TAMV, cm/s), pulsatility index (PI) and resistance index (RI) were recorded. Data were analysed with mixed models using the PROC MIXED procedures, and Pearson correlation coefficients were calculated using the PROC CORR statement in SAS. The final statistical models included the fixed effects of side of UA, gestation month and the interaction between side of UA and gestation month. Results revealed that the mean diameter of the UA (12.13 ± 0.22 vs. 10.09 ± 0.22), BFVo (1236.33 ± 0.55 vs. 770.41 ± 0.55), BFVe (17.18 ± 0.42 vs. 15.58 ± 0.42) and TAMV (17.11 ± 0.44 vs. 15.77 ± 0.44) was higher (p < .05) in IPS as compared to CONT side of the UA in cows. However, PI and RI did not differ between IPS and CON arteries of uterus in cows. A very high and positive correlation (r = .89; p < .05) existed between the diameter of UA and BFVo starting from 1st to 8th months of gestation in IPS as well as CONT sides of UA. Moreover, TAMV was highly and positively correlated (r = .91; p < .05) with BFVe throughout the gestation. In conclusion, these haemodynamic changes in the UA could be used as a valuable validity tool to differentiate the compromised pregnancy in Bos indicus cows.  相似文献   

3.
There are numerous publications about feline renal imaging information; however, none have established reference values for kidney size using computed tomography (CT). This study aimed to determine renal size and shape as well as the morphology of renal‐related structures in clinically normal cats (Felis catus) that underwent CT. Twenty‐seven healthy cats underwent pre‐ and post‐iodinated contrast‐enhanced CT. Most cat (59%) kidneys were located at the same level. The average pre‐contrast dimensions of the left kidney included a width of 2.46 ± 0.28 cm, a length of 3.52 ± 0.44 cm and a height 2.19 ± 0.31 cm, whereas those of the right kidneys were 2.45 ± 0.27 cm, 3.54 ± 0.46 cm and 2.05 ± 0.23 cm, respectively. After contrast enhancement, kidneys were slightly enlarged though not significantly. Additionally, renal length (LK or RK) was compared with second lumbar vertebra (L2) length and abdominal aorta diameter (AO). AO was significantly larger in male cats whereas L2 length appeared longer in male cats, but was not statistically different from the female cats. The LK/L2 and RK/L2 ratios were 2.29 ± 0.23 and 2.36 ± 0.20, respectively, and the LK/AO and RK/AO were 11.72 ± 1.37 and 12.05 ± 1.47, respectively. Renal vessels were examined. The renal vein was obviously larger than the renal artery, and paired renal veins were observed periodically. This study provides CT information about the feline kidney, which may help to establish reference values and information regarding renal structure prior to surgery in practice.  相似文献   

4.
O bjective : To describe the computed tomographic and magnetic resonance imaging features of segmental caudal vena cava aplasia and associated vascular anomalies in dogs.
M ethods : A retrospective study was performed reviewing computed tomographic and magnetic resonance imaging archives of eight institutions for dogs with segmental caudal vena cava aplasia. Inclusion criteria included a computed tomographic or magnetic resonance imaging study and supportive diagnostic and follow-up information. Abdominal vessels were reviewed for size, shape, location and course (including tributaries and branches) and classified as normal, abnormal or shunt vessels.
R esults : Ten dogs with segmental caudal vena cava aplasia were identified. In all dogs, postrenal caval blood was shunted to either a right or a left azygos vein, with seven different angiographic patterns. Affected dogs were predominantly female (70 per cent) and young (mean 2·6 years). Additional portocaval and porto-azygos shunt vessels were identified in two cases each. Computed tomographic angiography and magnetic resonance angiography depicted details of abdominal vessels including thrombus formation in one dog.
C linical S ignificance : Segmental caudal vena cava aplasia is a vascular congenital anomaly in the dog that can be associated with thrombosis and portosystemic shunts. Computed tomographic angiography and magnetic resonance angiography are excellent tools to demonstrate the complex vascular anatomy and to guide treatment planning for portosystemic shunts and thrombolytic therapy.  相似文献   

5.
Purpose: To describe the protocol and appearance of fluorescein angiography (FA) in normal horses. Animals: A total of 25 healthy horses aged between 5 and 15 years. Materials and Methods: The horses were sedated with 15 µg/kg detomidine and 50 µg/kg butorphanol and dilated with topical tropicamide 1%. All angiograms were recorded after intravenous bolus injection of 10 mg/kg of fluorescein sodium solution. Results: Two successive angiographic phases could be discerned: the choriopapillary phase, starting at 46.95 ± 9.48 s, and the retinal vascular phase, starting at 47.79 ± 10.38 s. The retinal vascular phase was divided in three parts: filling phase, maximum fluorescence point, and fading phase. During the filling phase, the dye progressed into the retinal vessels, obtaining maximum fluorescence at 59.79 ± 10.39 s, termed the maximum fluorescence point. The fading phase started immediately following the maximum fluorescence point. During this phase, vascular fluorescence decreased to complete reduction at 74.76 ± 9.81 s. Also, areas of delayed choroidal filling, the presence of short retinal vessels in the ventral region of the optic disc, and a particular filling of the optic disc were also observed. Conclusions: The normal angiographic sequence was described in horses. FA may be a useful method for studying the integrity of the blood–retinal barriers in horses.  相似文献   

6.
There is a paucity of information on the relationships of testicular morphology, echotextural attributes, and blood flow dynamics with pubertal development of rams raised in a subtropical climate. Forty‐five Dorper rams (24 rams aged 8–11 months and 21 rams aged 12–24 months) were examined using a portable ultrasound scanner connected to a 7.5‐MHz transducer. Computer‐assisted analyses of testicular ultrasonograms utilized commercially available Image ProPlus® analytical software. Spectral Doppler scans of testicular arteries were performed immediately after scrotal (B‐mode) ultrasonography to determine peak systolic velocity (PSV), end‐diastolic velocity (EDV), resistive index (RI = [PSV?EDV]/PSV), and pulsatility index (PI = [SPV–EDV]/mean velocity) of the blood vessels. The length of the testes (9.7 ± 0.3 compared with 9.0 ± 0.2 cm) and scrotal circumference (33.3 ± 0.5 compared with 31.8 ± 0.4 cm) were greater (p < 0.05) but testicular depth (4.5 ± 0.1  compared with 4.9 ± 0.08 cm) was less (p < 0.05) in sexually mature compared with peripubertal rams. [Corrections added on 9 Jan 2019 after initial online publication: The testicular size values in the sentence were corrected.] There were no differences (p > 0.05) between the two age groups of Dorper rams in blood flow indices of testicular arteries. Mean numerical pixel values (100.5 ± 4.1 compared with 89.2 ± 4.8) and pixel heterogeneity (25.6 ± 0.6 compared with 23.6 ± 0.5) of testicular parenchyma were greater (p < 0.05) in peripubertal than in postpubertal rams. Semen volume was negatively correlated with PI of testicular arteries (r = ?0.57, p = 0.04). In summary, the attainment of sexual maturity in the rams of the present study was associated with significant changes in testicular length and depth, scrotal circumference, and parenchymal echogenicity/hetrogeneity but not in testicular volume and blood perfusion rates. Testicular artery PI can be used to predict the volume of ejaculate in rams.  相似文献   

7.
The testicular morphology, spermatogenesis and occurrence of sperm in the ovarian lumen of Trachelyopterus striatulus were studied using anatomical, histological and biometric techniques. A total of 50 catfish (T. striatulus) were captured, measuring 14.9 ± 2.5 cm of standard length, body weight was 81.2 ± 34.5 g and their testes weighed 16.9 ± 6.1 g. The testes of T. striatulus are paired organs, showing two distinct regions: cranial, which shows a compact medial part and with fringes ventrally, and caudal region, which is formed of the seminal vesicle with fringes laterally and two saculiform expansions. The testes presented a length of 35.2 ± 6.9 mm, and the fringes showed a cranial length of 12.1 ± 3.8 mm and caudal length of 6.4 ± 2.6 mm. Histologically, the cranial fringes are spermatogenic and showed cells with significantly different nuclear diameters, ranging from 8.2 ± 1.5 μm (primary spermatogonia) to 1.88 ± 0.3 μm (spermatid). The seminal vesicles and saculiform expansions showed tubules with a simple prismatic secretory epithelium containing spermatozoa and secretion into the lumen. The caudal fringes are exclusively for secretory flow, consisting of tubules with a simple cuboidal epithelium. The common spermatic duct showed a simple cuboidal epithelium and contained spermatozoa with secretion into the lumen. The secretion of the caudal region is acidophilic, with neutral glycoproteins and sialomucin. T. striatulus ovaries showed free spermatozoa or were organized in spermatozeugmata into the ovarian lumen and between the ovuligers lamellae.  相似文献   

8.
This study aimed to determine the usefulness of colour and pulsed Doppler modes for the accurate diagnosis of donkeys suffering from subfertility to determine whether testicular vascularity assessment could be an indicator for sperm functionality. The study sample was composed of 10 male donkeys with normospermia (control group) and 10 donkeys with hypospermia. Animals underwent scrotal circumference measurement, testicular Doppler examination, seminal evaluation, blood sampling and hormonal assay. Semen volume and concentration were significantly (p ≤ .05) lower in the subfertile group (30.25 ± 1.22 ml and 89.44 ± 2.55 × 106/ml) as compared with the control group (82.76 ± 1.65 ml and 452.78 ± 1.25 × 106/ml), and total sperm/ejaculation was significantly (p ≤ .05) higher in the normal donkeys (28.30 ± 2.32 × 109/total ejaculated) as compared with the subfertile group. Intratesticular coloured area showed a marked decline in the hypospermic males. There was no significant difference between the two groups in testosterone level, although the normal group showed an increase in nitric oxide metabolites. Both Doppler indices of the three branches of the testicular artery were elevated significantly (p ≤ .05) in abnormal donkeys, whereas Doppler peak systolic and end-diastolic velocities were increased in the normal group. Male donkeys with subfertility demonstrated lower arterial vascularity parameters in the form of intratesticular coloured area and blood flow rate; therefore, the most optimal parameters for differentiating subfertile hypospermic from normospermic donkeys were found to be the two Doppler indices, velocities parameters, testicular blood flow rate and nitric oxide levels.  相似文献   

9.
ObjectiveTo evaluate a direct intra-abdominal approach to injection of the ventral transversus abdominis plane (TAP) and compare the dispersion of two volumes of injectate.Study designProspective anatomic and feasibility study.AnimalsA total of 10 canine cadavers weighing 9 ± 4 kg.MethodsA ventral incision was made extending through the linea alba, from the umbilicus and extending 5 cm caudally. A single injection of an isovolumic mixture of iopamidol and new methylene blue was performed with a hypodermic needle placed within the TAP of each hemiabdomen, alternating between 0.5 mL kg–1 in low-volume group (LV) and 1 mL kg–1 in high-volume group (HV). Surgical staples marked the incision. Computed tomography and three-dimensional reconstruction of the tomographic images evaluated the dimensions, cranial and caudal spread beyond the incision and the total area of the injectate. Dissection determined the extent of nerve staining within the TAP adjacent to the abdominal incision. Wilcoxon signed rank (stain) or paired t test was used to compare variables between groups. Data are reported as mean ± standard deviation or median (range).ResultsInjectate spread was within the ventral TAP. Length of spread was 2.5 ± 1.6 cm greater in group HV than in group LV. There was a strong positive correlation between the surface area (p = 0.02, r = 0.71) and cranial–caudal spread of injectate (p = 0.041, r = 0.65) with volume.All but two LV injections were associated with staining of all nerves adjacent to the incision. Additional nerves caudal to the incision were stained in group HV (p = 0.02).ConclusionsThis approach to the TAP was easily performed, with volume of injectate positively influencing distribution.Clinical relevanceThis technique is easily applied and future prospective studies are warranted to determine its analgesic efficacy.  相似文献   

10.
Anti‐Müllerian hormone (AMH) is produced in the ovary, and thus, it is an excellent marker of follicle pool in females. Current interest is the clinical use of this parameter as a biomarker to assess presence or absence of an intact ovary and to diagnose ovarian remnant syndrome (ORS) following incomplete ovariohysterectomy (OHE) in bitches. The aim of this study was to evaluate serum AMH concentrations in bitches (n = 34) before and after OHE using two different commercial ELISA kits, one of which is based on detecting human AMH and the other is based on detecting human AMH and the other specified for canine AMH. Furthermore, serum AMH levels were also measured in six ORS cases to compare the diagnostic utility of the two different ELISA kits. Serum AMH concentrations measured using the human and canine kit prior to and after OHE were 0.32 ± 0.24, 0.006 ± 0.22 ng/ml (p < .001) and 12.08 ± 22.81, 9.55 ± 15.42 ng/ml (p = .868), respectively. Thus, the canine‐based kit was not able to reveal the significant drop in serum AMH levels. In conclusion, the human‐based ELISA kits successfully detected the drop in serum AMH concentrations. Reliable results can only be achieved from well‐designed ELISA kits, and AMH levels might be a useful diagnostic tool for the evaluation of presence or absence of ovaries as well as for the detection of ORS cases in bitches.  相似文献   

11.
12.
A duplex ultrasound system incorporating a pulsed wave Doppler ultrasound probe with conventional B-mode real-time imaging was used to evaluate portal vein blood flow in eight normal dogs. Adequate visualization of the cranial abdominal vessels was obtained from the right lateral 11th or 12th intercostal space. Doppler spectral analysis showed non-pulsatile flow with a wide range of linear flow velocities across the vessel lumen typical of laminar blood flow. Results for portal vein blood flows were 49.8 ± 13.5 ml/min/kg body weight (mean ± SD) with a range of 37.8 - 76.8 ml/min/kg body weight. These values overestimate portal blood flow by approximately 2 times when compared with published studies using invasive techniques. This overestimation is primarily due to the use of the maximal flow velocity in the blood flow calculations.  相似文献   

13.
This study determined the unbound fraction of the peripheral α2‐adrenoceptor antagonist MK‐467 alone and combined with medetomidine. MK‐467 (0.1, 1 and 10 μm ) was incubated in canine plasma with and without medetomidine (molar ratio 20:1), with human serum albumin (HSA) and with α1‐acid glycoprotein (AGP). Rapid equilibrium dialysis was used for the measurement of protein binding. All samples were analysed by liquid chromatography and tandem mass spectrometry to obtain the unbound fraction (fu) of MK‐467. Unbound fractions (fu) of MK‐467 in canine plasma (mean ± standard deviation) were 27.6 ± 3.5%, 26.6 ± 0.9% and 42.4 ± 1.2% at 0.1, 1.0 and 10 μm concentrations, respectively. In the presence of medetomidine, fu were 27.5 ± 0.4%, 26.6 ± 0.9% and 41.0 ± 2.4%. The fu of MK‐467 in HSA were 50.1 ± 2.5% at 0.1 μm , 49.4 ± 1.2% at 1.0 μm and 56.7 ± 0.5% at 10 μm . fu of MK‐467 in AGP was 56.3 ± 3.7% at 0.1 μm , 54.6 ± 5.6% at 1.0 μm and 65.3 ± 0.4% at 10 μm . Protein binding of MK‐467 was approximately 70% between 0.1 and 1.0 μm . Medetomidine had no apparent effect on the protein binding of MK‐467.  相似文献   

14.
Mesentery samples obtained from 13 mixed breed cats were stereoscopically and microscopically examined and yielded the following results. In the mesentery, lamellar corpuscles were densely distributed around blood vessels, with a mean number of 182.2 ± 20.9 and mean maximum and minimum diameters of 0.98 ± 0.18 mm and 0.54 ± 0.08 mm, respectively. While most lamellar corpuscles were isolated, some complex lamellar corpuscles were found in the mesentery. Lamellar corpuscles in the mesentery appear to serve more as internal receptors that detect changes in the internal environment than as external receptors. In addition, those found around blood vessels in the mesentery are likely to be involved in blood pressure regulation.  相似文献   

15.
ObjectiveTo describe the gross and ultrasound anatomy of the parasacral region and an ultrasound-guided greater ischiatic notch (GIN) plane approach aimed at staining the lumbosacral trunk (LST) in canine cadavers. To evaluate if the ultrasound-guided GIN plane approach is non-inferior to the previously described ultrasound-guided parasacral approach at staining the LST.Study designProspective, randomized, non-inferiority experimental anatomic study.AnimalsA total of 17 (23.9 ± 5.2 kg) mesocephalic canine cadavers.MethodsAnatomic and echographic landmarks, and the feasibility of performing a GIN plane technique were evaluated using two canine cadavers. The remaining 15 cadavers had each hemipelvis randomly assigned to be administered either parasacral or GIN plane injection of 0.15 mL kg–1 dye solution. The parasacral region was dissected after injections to assess the staining of LST, cranial gluteal nerve, pararectal fossa and pelvic cavity. The stained LST were removed and processed for histological evaluation of intraneural injections. A one-sided z-test for non-inferiority (non-inferiority margin –14%) was used to statistically evaluate the success of the GIN plane versus the parasacral approach. Data were considered statistically significant when p < 0.05.ResultsThe GIN plane and parasacral approach stained the LST in 100% and 93.3% of the injections, respectively. The success rate difference between treatments was 6.7% [95% confidence interval, –0.6 to 19.0%; p < 0.001 for non-inferiority]. The GIN plane and parasacral injections stained the LST for 32.7 ± 16.8 mm and 43.1 ± 24.3 mm, respectively (p = 0.18). No evidence of intraneural injection was found.Conclusions and clinical relevanceThe ultrasound-guided GIN plane technique resulted in nerve staining that was non-inferior to the parasacral technique and may be considered an alternative to the parasacral approach to block the LST in dogs.  相似文献   

16.
The oestrus cycle in the domestic bitch, a monoestrous species, differs considerably from that of other veterinary domestic animals species. In the bitch the combined use of eCG and hCG is effective to induce oestrus predictably and safely (Stornelli et al., Theriogenology, 78, 2012 and 1056). Although several studies were done to describe the hormonal changes during the canine oestrus cycle, to our knowledge none was done to describe the hormonal changes during induced follicular growth after the administration of eCG. The aim of this work was to study prolactin (PRL), insulin‐like growth factor (IGF1) and androstenedione (ANDR) serum concentrations during follicular growth induced by a single dose of eCG administered to late anoestrous bitches. PRL and ANDR concentrations were lower before than after eCG TRT (before eCG vs pro‐oestrus, oestrus and dioestrus; 4.3 ± 1.8 ng/ml vs 6.5 ± 1.6 ng/ml, p < 0.05; 0.08 ± 0.2 ng/ml vs 0.42 ± 0.16 ng/ml, p < 0.05). Conversely, IGF1 concentrations were similar before and after eCG TRT (286.0 ng/ml ±32.2, p > 0.53). Additionally, PRL concentrations were similar before oestrus compared to during oestrus and dioestrus (6.9 ± 1.7 ng/ml, p > 0.19). Furthermore, IGF1 concentrations were higher before and during oestrus compared to first day of dioestrus (286.1 ± 29.8vs 200.4 ± 29.2 ng/ml, p < 0.01). On the contrary, ANDR concentrations were lower before and during oestrus compared to first day of diestrum (0.35 ± 0.17 ng/ml and 0.38 ± 0.15 vs 0.68 ± 0.17 ng/ml, p < 0.05). These results show that treatment with a single injection of 50 IU/kg of eCG in late anoestrous bitches successfully induced changes in follicular growth which were paralleled with changes in PRL, IGF1 and ANDR serum concentration similar to those occurring during a normally occurring oestrous cycle. In addition, our results suggest that IGF1 in the bitch could play an important role in ovarian folliculogenesis.  相似文献   

17.
The aim of this study was to determine serum levels of natriuretic peptide precursors (NT‐proANP and NT‐proBNP) during pregnancy in brachycephalic bitches. Fifteen healthy multiparous bitches were selected for this prospective study. Serum levels of NT‐proANP and NT‐proBNP were measured during anoestrous and at 14, 35, 42, 49 and 56 days (2nd, 5th, 6th, 7th and 8th weeks) of pregnancy. Fourteen animals had normal gestations, and one bitch developed single foetus syndrome. The natriuretic peptide levels of this animal were not included in this study; however, it is important to report that its NT‐proANP levels were four times greater than those of normal patients. There was no significant difference (p = 0.072) in NT‐proBNP levels between anoestrous (0.20 ± 0.10 ng/ml) and the different pregnancy weeks (0.27 ± 0.12 ng/ml). There was a positive correlation (p < 0.0001) between NT‐proANP and gestational age, and the levels of this marker increased significantly (p < 0.0001) during the 6th (0.26 ± 0.06 ng/ml), 7th (0.28 ± 0.04 ng/ml) and 8th weeks (0.29 ± 0.05 ng/ml) when compared to anoestrous (0.18 ± 0.02 ng/ml). NT‐proANP serum levels are correlated with gestational development and may be indicative of cardiovascular adaptation in canine brachycephalic pregnancy.  相似文献   

18.
We describe the technique for in vivo cardiac‐gated magnetic resonance imaging (MRI) in normal dogs and its application in two dogs with a large right atrial tumor. The dogs with a cardiac tumor were also imaged using contrast‐enhanced magnetic resonance angiography (CE‐MRA). Cardiac‐gated MRI and CE‐MRA are both feasible in animals with short acquisition times compatible with breath‐hold imaging under anesthesia, and provide detailed two‐ and three‐dimensional (3D) depiction of the cardiac anatomy and great vessels with or without contrast medium. Although cardiac MRI will not replace echocardiography, it is a powerful alternative technique to use when knowledge of the 3D anatomy of the vasculature is required, when precise volume measurements are needed or when myocardial characterization is indicated. As opposed to contrast‐enhanced computed tomography angiography, cardiac MRI does not use ionizing radiation or iodinated contrast medium.  相似文献   

19.
The navigation behavior of catheters within the equine pulmonary artery (PA) was investigated using en bloc heart and lung preparations for the purpose of developing a method of blind catheter placement. An equine ex vivo heart and lung perfusion system with controlled perfusate pulsatile flow, pressure, and temperature was used to evaluate a blind navigation technique for placement of balloon-tipped catheters into the distal main stem of the PA. Catheter performance was observed with an intravascular endoscope. Three balloon catheters were selected for navigation trials: a 4 mm diameter × 1.2 cm, 2.7Fr, 142 cm angioplasty catheter (C4mm); a 10 mm diameter × 4 cm, 5Fr, 150-cm angioplasty catheter (C10mm); and a 16-mm diameter, 7Fr, 200-cm pancreatic duct sphincteroplasty catheter (C16mm). Successful catheter placement was defined as insertion within a left or right main stem of the PA to a distance greater than 20 cm beyond the bifurcation. A method of blind catheter placement into the distal main stem of the equine PA using balloon-tipped catheters was successfully developed. The 16-mm catheter was superior with an average proportion of successful insertions (PSIavg) of 93.6%; an average insertion distance in the main stem (IDMavg) of 30.1 ± 5.7 cm; and an average insertion distance anywhere in the PA (IDAavg) of 29.3 ± 6.4 cm versus the 10 mm (PSIavg 25%, IDMavg 39.3 ± 11.4 cm, IDAavg 19.3 ± 15.1 cm) and 4 mm (PSIavg 11%, IDMavg 40.0 ± 11.0 cm, IDAavg 12.8 ± 13.2 cm), respectively.  相似文献   

20.
The evaluation of progesterone (P4) concentration is a valuable tool in assessing physiological reproductive events and reproductive disorders in bitches. A reliable and rapid (preferable, point of care) determination of P4 is advisable in most cases. Aims of this study were to evaluate a fluorescence enzyme immunoassay (FEIA) for canine serum P4 concentration by (i) the agreement with liquid chromatography–tandem mass spectrometry (LC/MS/MS), (ii) the association with vaginal cytology and (iii) the accuracy in the prediction of the parturition date calculated from the estimated day of ovulation. Serum samples were collected from client‐owned bitches presented between 2011 and 2014 for the evaluation of their oestrous cycle, pregnancy or reproductive disorders. The agreement between FEIA and LC/MS/MS, evaluated on 19 samples, was statistically significant (R2 = 95.7%, p < 0.001), although FEIA showed significantly higher values than LC/MS/MS (p < 0.05). In the different phases of oestrous cycle, as determined by vaginal cytology, P4 concentrations (by FEIA) were statistically different (p < 0.05): anoestrus (n = 7) 0.38 ± 0.14 ng/ml, proestrus (n = 14) 1.04 ± 0.67 ng/ml and oestrus (n = 72) 6.8 ± 7.26 ng/ml. Mean pregnancy length from the estimated day of ovulation was 62.9 ± 1.8 days. In 13 of 22 (59.1%), 19 of 22 (86.3%) and 21 of 22 (95.5%) bitches pregnancy lasted 63 ± 1, 63 ± 2 and 63 ± 3 days, respectively. Three pregnancies were outside the 61–65 days range (60, 60 and 67 days). In conclusion, the FEIA method employed can be considered reliable and, in association with vaginal cytology, effective in evaluating the canine oestrous cycle.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号