Survey of the prevalence and methodology of quality assurance for B‐mode ultrasound image quality among veterinary sonographers 下载免费PDF全文
Larry P. Hoscheit Hock Gan Heng Chee Kin Lim Hsin‐Yi Weng 《Veterinary radiology & ultrasound》2018,59(3):326-332
Image quality in B‐mode ultrasound is important as it reflects the diagnostic accuracy and diagnostic information provided during clinical scanning. Quality assurance programs for B‐mode ultrasound systems/components are comprised of initial quality acceptance testing and subsequent regularly scheduled quality control testing. The importance of quality assurance programs for B‐mode ultrasound image quality using ultrasound phantoms is well documented in the human medical and medical physics literature. The purpose of this prospective, cross‐sectional, survey study was to determine the prevalence and methodology of quality acceptance testing and quality control testing of image quality for ultrasound system/components among veterinary sonographers. An online electronic survey was sent to 1497 members of veterinary imaging organizations: the American College of Veterinary Radiology, the Veterinary Ultrasound Society, and the European Association of Veterinary Diagnostic Imaging, and a total of 167 responses were received. The results showed that the percentages of veterinary sonographers performing quality acceptance testing and quality control testing are 42% (64/151; 95% confidence interval 34–52%) and 26% (40/156: 95% confidence interval 19–33%) respectively. Of the respondents who claimed to have quality acceptance testing or quality control testing of image quality in place for their ultrasound system/components, 0% have performed quality acceptance testing or quality control testing correctly (quality acceptance testing 95% confidence interval: 0–6%, quality control testing 95% confidence interval: 0–11%). Further education and guidelines are recommended for veterinary sonographers in the area of quality acceptance testing and quality control testing for B‐mode ultrasound equipment/components. 相似文献
4.
Sang‐Kwon Lee Sooa Yoon Cheolhyun Kim Jihye Choi 《Veterinary radiology & ultrasound》2019,60(5):493-501
Computed tomography angiography is widely used for the assessment of various mesenteric vascular and bowel diseases in humans. However, there are only few studies that describe CT angiography application to mesenteric vessels in dogs. In this prospective, experimental, exploratory study, the mesenteric vasculature and enhancement pattern of the intestinal wall were evaluated on triple‐phase CT angiography, and improvement of the visibility of vasculature was assessed on multiplanar reformation, maximum intensity projection, and volume rendering technique. After test bolus scanning at the level of the cranial mesenteric artery arising from the aorta, mesenteric CT angiography was performed in 10 healthy, male, Beagle dogs. Scan delay was set based on time‐to‐attenuation curves, drawn by placing the regions of interest over the aorta, intestinal wall, and cranial mesenteric vein. Visualization and enhancement of mesenteric arteries and veins were evaluated with multiplanar reformation, maximum intensity projection, and volume rendering techniques. The degree of intestinal wall enhancement was assessed on the transverse images in precontrast, arterial, intestinal, and venous phases. Pure arterial images were obtained in the arterial phase. Venous phase images allowed good portal vascular mapping. All CT angiography images were of high quality, allowing for excellent visualization of the anatomy of mesenteric vasculature including the small branches, particularly on maximum intensity projection and volume rendering technique. Distinct contrast enhancement of the intestinal wall was observed in both intestinal and venous phases. Findings indicated that this technique is feasible for the evaluation of mesenteric circulation in dogs. 相似文献
5.
Analytic and quality control validation and assessment of field performance of a point‐of‐care chemistry analyzer for use in the White rhinoceros 下载免费PDF全文
Emma H. Hooijberg Gerhard Steenkamp Jacques P. du Preez Amelia Goddard 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2017,46(1):100-110
6.
Verification of the Heska Element Point‐of‐Care blood gas instrument for use with venous blood from alpacas and llamas,with determination of reference intervals 下载免费PDF全文
Lisa C. Viesselmann Ricardo Videla Bente Flatland 《Veterinary clinical pathology / American Society for Veterinary Clinical Pathology》2018,47(3):435-447