首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Two different whole-virus enzyme-linked immunosorbent assays (ELISAs), developed in Ohio (OH) with APV/Minnesota/turkey/2a/97 and in Minnesota (MN) with APV/Colorado/turkey/97, and the virus neutralization (VN) test were used to test 270 turkey serum samples from 27 Minnesota turkey flocks for avian pneumovirus (APV) antibodies. In addition, 77 turkey serum samples and 128 ostrich serum samples from Ohio were tested. None of the turkey samples from Ohio had antibodies to APV by the VN test and OH ELISA. The ostrich samples were only tested with the VN test and were all negative for antibodies to APV. For the Minnesota serum samples, 107, 115, and 120 were positive by the VN test, the OH ELISA, and the MN ELISA, respectively. The Kappa values of 0.938 and 0.825 showed excellent agreement between the VN test and the OH ELISA and the MN ELISA, respectively, for detection of antibodies to the APV. The OH ELISA and MN ELISA had sensitivities of 1.0 and 0.953, specificities of 0.950 and 0.889, and accuracies of 0.970 and 0.914, respectively. Our results indicate that the 3 methods are sensitive and specific for diagnosis of the APV infection.  相似文献   

2.
3.
Enzyme-linked immunosorbent assays (ELISAs) are used in Johne's disease (JD) control programs as a first screening for presence of the disease in a herd. A high sensitivity of the ELISA is therefore important, yet the commonly used ELISAs have relatively low sensitivity. The inclusion of an absorption phase, although improving specificity, potentially decreases sensitivity. Sera and feces of 383 adult dairy cows in 8 herds were used to compare the test characteristics of an absorbed and a nonabsorbed indirect ELISA for the detection of JD. The absorbed ELISA is based on a protoplasmic antigen, whereas the nonabsorbed uses a lipoarabinomannan-based antigen. The potential advantage of the nonabsorbed ELISA is that it may be less specific and more sensitive. Two herds certified free of JD were used to compare the specificity of the ELISAs. The other herds used to compare sensitivity were either infected with Mycobacterium avium subsp. paratuberculosis or had unknown status. Using fecal culture as a gold standard, the diagnostic specificity for the absorbed and nonabsorbed ELISAs were 98.4% and 87.9%, respectively. The diagnostic sensitivity was 72.4% and 65.5% for the absorbed and the nonabsorbed ELISA, respectively. Furthermore, a comparison using a fecal DNA probe as the comparison standard resulted in both ELISAs having a sensitivity of 61.9%. Agreement between the 2 ELISAs was moderate, with a kappa statistic of 0.58. The nonabsorbed ELISA did not have a higher sensitivity and had a lower specificity than the absorbed ELISA. Therefore, in this population, there was no advantage gained with using the nonabsorbed ELISA.  相似文献   

4.
The purpose of this study was to estimate the performance characteristics (accuracy, detection limit, and precision) of commercially available enzyme-linked immunosorbent assay (ELISA) and agar gel immunodiffusion (AGID) kits in comparison with a reference AGID kit for the detection of equine infectious anemia (EIA) antibodies in horses for regulatory use in Canada. A total of 285 positive and 315 negative samples by the reference AGID were tested blindly on 2 other AGID and 4 ELISA kits. Commercially available AGID kits for the serodiagnosis of EIA were found equivalent. The 3 ELISAs directed against antibodies to the p26 core protein also performed relatively well in comparison with the reference AGID, with excellent relative accuracy and acceptable precision. The single ELISA directed against antibodies to the gp45 trans-membrane viral protein yielded a lower relative sensitivity. The performance characteristics of the ELISAs directed against antibodies to p26 are, therefore, adequate to support the implementation of ELISA for regulatory purposes in Canada.  相似文献   

5.
Immunoglobulin class-specific enzyme-linked immunosorbent assays were developed for detecting antibodies against avian rotavirus in serum, intestinal contents, and bile from experimentally infected specific-pathogen-free (SPF) chickens. Both indirect and antibody-capture (AbC) assays were developed based on monoclonal antibodies specific for chicken IgG, IgM, and IgA. Treatment of purified rotavirus with sodium thiocyanate before coating the plate improved the rotavirus-specific reading in the indirect assay. Use of Immunolon 2 plates facilitated attachment of monoclonal antibodies to the plate in the AbC assay. Addition of 5% powdered skim milk to the diluent buffer reduced nonspecific background readings. The indirect assay was superior for detecting rotavirus-specific IgG, whereas the AbC assay was better for detecting rotavirus-specific IgM and IgA. The presence of intestinal contents in the assay wells did not reduce the measurable titers of IgG, IgM, or IgA. These assays showed that SPF chickens produced systemic and mucosal antibodies against avian rotavirus.  相似文献   

6.
7.
Abstract

Extract

The double gel diffusion test (GDT) is the internationally accepted standard method for detection of antibodies against bovine leukemia virus (BLV)(1 Anonymous International Zoo-Sanitary Code P310 Office International des Epizootie 1986 Paris  [Google Scholar]). The method has been standardised (within certain limits) and a reference serum has been introduced by the European Commission to control the level of sensitivity of the test.  相似文献   

8.
AIM: To assess the ability of two commercial bovine viral diarrhoea (BVD) virus (BVDV) antigen-capture enzyme-linked immunosorbent assays (ELISAs) to detect virus in serum and skin biopsies. METHODS: Thirty cattle persistently infected (PI) with BVDV were identified using routine diagnostic laboratory testing. Additional ear-notch skin biopsies and blood samples were collected from these animals to confirm the diagnosis, and from 246 cohorts, to determine their BVDV status. Skin biopsies were soaked overnight in buffer and the eluate collected. All sera and eluate were tested using two commercially available ELISAs for detecting BVDV antigen, and a subsample of positive and negative sera was tested using a polymerase chain reaction (PCR) test. A study was also performed to ascertain the risk of cross contamination occurring during the collection and processing of skin biopsies. RESULTS: Both serum and skin samples tested using either ELISA resulted in the detection of all cattle identified as PI and no non-infected cattle were incorrectly classified as infected using either method. Agreement between all assays (ELISAs, whether performed on serum or skin, and PCR) was 100%. No cross-contamination of skin samples between animals was evident using routine biopsy methods. CONCLUSIONS: Viraemic cattle infected with BVDV were accurately identified using either of the two commercial ELISAs evaluated on either serum or skin samples. CLINICAL RELEVANCE: Either skin biopsies or serum samples can be collected from cattle to determine their BVDV status. This should overcome problems in accurately identifying the infection status of young calves in which colostral antibodies might interfere with the antigen-capture ELISA.  相似文献   

9.
Large discrepancies are usually found when different ELISAs for the diagnosis of pig salmonellosis are compared. Thus, our main goal was to estimate the diagnostic accuracy through Bayesian approaches of two commercial assays (Svanovir™ “test A” and HerdCheck™ “test B”) for the detection of antibodies to Salmonella spp. in slaughter pigs. Previously, we estimated the agreement between both tests and their relative sensitivity (Se) and specificity (Sp) with respect to bacteriology on caecal content and ileocaecal lymph nodes. Test A, at a cut-off OD% ≥20%, indicated higher prevalence than test B (OD% ≥10%) (14.6% vs. 8.6%). Relative Se with respect to overall bacteriology was low (≈30%) and similar for both tests, but the relative Sp was significantly lower for test A compared to B (88% vs. 95%). Both tests failed to detect some pigs infected with Salmonella serogroups B and C1, which they were supposed to identify. In general, tests showed only fair-to-moderate agreement when they were compared (kappa: 0.41). In the Bayesian models, Se of test A varied between 63% and 77%, while Se of test B was 73%. Sp of A was always lower than that of test B (89% vs. 95%). The implications derived from the use of these imperfect serological tests will have to be accounted for in large-scale Salmonella-control programs.  相似文献   

10.
An enzyme-linked immunosorbent assay (ELISA) system was developed for the detection of canine parvovirus (CPV) or CPV antigen in dog faeces and two other ELISA systems were developed for the detection of CPV-specific antibodies in dog sera. The ELISA's were based on the use of CPV-specific mouse monoclonal antibodies, which recognise different epitopes of the haemagglutinin of CPV and which also neutralise the virus. A double antibody sandwich (DAS) ELISA for the detection of CPV in dog faeces was compared with the haemagglutination (HA) test. The DAS-ELISA proved to be more specific, sensitive and easier to perform than the HA assay. An indirect ELISA and a competitive ELISA for the detection of CPV-specific antibodies in dog sera were compared with the haemagglutination inhibition (HI) test. Both ELISA systems proved to be specific and easy-to-use methods for the detection of CPV-specific antibodies. The indirect ELISA, specially, proved to be more sensitive than the HI test. The higher sensitivity and specificity of the ELISA's as compared to HA and HI tests, and their ease of use, make them suitable for routine use in the serology and diagnosis of CPV infections.  相似文献   

11.
Bluetongue (BT) is a reportable re-emerging vector-borne disease of animal health concern. Enzyme-linked immunosorbent assays (ELISA) are frequently used in BT surveillance programs in domestic ruminants, but their diagnostic accuracy has not been evaluated for wild ruminants, which can play an important role as natural reservoirs of bluetongue virus (BTV). The aim of this study was to assess two commercial ELISAs for BT diagnosis in wild ruminants using control sera of known BTV infection status and field samples. When control sera were tested, the double recognition ELISA (DR-ELISA) showed 100 % sensitivity (Se) and specificity (Sp), while the competitive ELISA (C-ELISA) had 86.4 % Se and 97.1 % Sp. Using field samples, the selected latent-class analysis model showed 95.7 % Se and 85.9 % Sp for DR-ELISA, 58.2 % Se and 95.8 % Sp for C-ELISA and 84.2 % Se for the serum neutralization test (SNT). Our results indicate that the DR-ELISA may be a useful diagnostic method to assess BTV circulation in endemic areas, while the C-ELISA should be selected when free-areas are surveyed. The discrepancy between control and field samples point out that the inclusion of field samples is required to assess the accuracy of commercial ELISAs for the serological diagnosis of BTV in wild ruminants.  相似文献   

12.
Mycoplasma hyopneumoniae (Mhyo) causes mycoplasmal pneumonia, an economically important disease of swine. Serodiagnosis of Mhyo is based on the current available commercial enzyme immunoassays for detection of swine antibodies against Mhyo, which are the indirect enzyme-linked immunosorbent assay (ELISA) and the blocking ELISA (B-ELISA). Because of the limited information available for these ELISAs, these 2 assays were compared by testing 347 serum samples collected from vaccinated pigs at 0, 13, 28, 43, and 62 days postimmunization (DPI), 50 samples from nonvaccinated pigs, and 1,013 field serum samples. The results of comparison study showed that the specificity for both ELISAs was 99.2% generated from 139 non-vaccinated negative samples. The sensitivities for indirect ELISA generated from samples collected from animals that received the vaccine at DPI 13, 28, 43, and 62 were 0%, 95.7%, 88.4%, and 92.6%, respectively, whereas the sensitivities for B-ELISA were 0%, 98%, 100%, and 97%, respectively. The overall agreement of 96.7% and 80.3% was generated between 2 ELISAs from negative and vaccinated pigs and from field samples, respectively.  相似文献   

13.
Serologic diagnosis of ovine contagious agalactia (Mycoplasma agalactiae) with the enzyme-linked immunosorbent assay (ELISA) developed by Agence Fran?aise de Sécurité Sanitaire des Aliments (AFSSA) may produce a few false-positive (FP) and false-negative (FN) results. When the prevalence of disease is low, these erroneous results may generate problems for eradication schemes. To prevent this, 2 commercial ELISAs were compared with the AFSSA ELISA. Flocks of known status were selected and classified into 4 categories: true positive (TP), FP, true negative (TN), and FN; 20 sheep per flock were submitted for blood sampling. A flock was considered positive when at least 1 out of 20 sera was positive or 2 sera were doubtful. In the flock, the diagnostic sensitivity of the 3 kits was very good (100%), and the diagnostic specificity showed an improvement from 46% (AFSSA test) to 88% and 92% (commercial tests). Considering individual animals, very few positive ewes were detected within TN or FP flocks; the proportion of positive ewes varied greatly from one kit to another (48% to 82%) within TP flocks. The kinetics of antibody response in sheep experimentally infected with various field strains of M. agalactiae were quite similar with all 3 ELISAs. The agreement between the 3 tests, assessed using the kappa value, varied from moderate to good (respective values of 0.56, 0.61, and 0.86). The 2 commercial ELISAs showed better performances, probably because of a superior analytical sensitivity, and are a good alternative for the serodiagnosis of contagious agalactia in sheep.  相似文献   

14.
A competitive enzyme-linked immunosorbent assay (ELISA) for the detection of swine trichinosis has been developed using a biotinylated monoclonal antibody and an avidin-enzyme conjugate. The assay is based on competitive binding between swine serum antibodies and a monoclonal antibody specific for an antigenic determinant present on proteins from Trichinella spiralis excretory-secretory products with molecular weights of 45,000, 49,000, and 53,000. The competitive ELISA reliably detected pigs infected experimentally with T. spiralis and eliminated false-positive reactions in pigs infected with other swine nematodes, particularly Trichurus suis. When the competitive ELISA and an indirect ELISA using affinity-isolated antigen were compared using serum from pigs with naturally-acquired infections of T. spiralis, both tests were highly effective in detecting infected animals.  相似文献   

15.

Background

Aleutian disease in mink is caused by infection with Aleutian mink disease virus (AMDV). In Sweden, the infection most commonly causes classical Aleutian disease in which the immune system fails to neutralize the virus and the infection becomes persistent. Diagnosis of AMDV infection is based on serological methods that detect virus-specific antibodies. Traditionally counterimmunoelectrophoresis (CIEP) has been the preferred method, but in order to enable automation interest has been paid to other antibody detecting systems. Recently, at least two different ELISA systems that detect antibodies to AMDV have been manufactured; one is based on an in vitro grown AMDV as antigen, and the other system is based on the AMDV capsid protein VP2 as antigen. The aim of this study was to evaluate the two ELISA systems for detection of antibodies to AMDV using CIEP as the gold standard.

Results

When employing the mean optical density of the samples from CIEP negative mink plus three standard deviations as cut-off value, the ELISA with the VP2 antigen had a sensitivity of 99.7% and a specificity of 98.3% compared to CIEP (n = 364). Analysis of samples with the AMDV-G antigen based ELISA employing an assay cut-off value based on the negative control samples, as suggested by the manufacturer, resulted in a sensitivity of 54.3% and a specificity of 93.2% with reference to CIEP as the gold standard (n = 359). When employing the mean optical density of the samples from CIEP negative mink plus three standard deviations as cut-off value, the AMDV-G ELISA had a sensitivity of 37.6% and a specificity of 98.3%.

Conclusions

The ELISA system based on VP2 antigen had high sensitivity and specificity, and was concluded to be an alternative to the CIEP as a diagnostic tool for AMDV antibodies. In contrast, the AMDV-G ELISA suffered from low sensitivity when compared to CIEP.  相似文献   

16.
The accuracy of 4 commercial enzyme-linked immunosorbent assays (ELISAs) for diagnosis of bovine paratuberculosis was compared using sera from 53 Mycobacterium avium subsp. paratuberculosis (MAP) fecal culture-positive dairy cows (cases) and sera from 345 dairy cattle resident in 11 fecal culture-negative herds on 2 consecutive occasions 1 year apart (controls). The specificity of all 4 ELISA kits was >99%, and their diagnostic sensitivity ranged from 30.2% to 41.5%. Pairwise comparison of ELISAs found no significant differences (McNemar's chi-square test > 0.05), and assay agreement for categorical assay interpretation (positive or negative) was high (>98%) with kappa values ranging from 0.84 to 0.95. Receiver operating characteristic (ROC) curve analysis and the corresponding area under the ROC curves indicate that kit B had the highest overall accuracy. Thus, all 4 ELISA kits for bovine paratuberculosis had comparable accuracy when tested on Chilean dairy cattle, with kit B having a slight statistical advantage based on ROC area under the curve analysis. This suggests that any of the 4 kits could be appropriate for herd certification and for paratuberculosis control programs on Chilean dairy cattle.  相似文献   

17.
A P Avakian  J W Dick 《Avian diseases》1985,29(4):1277-1280
Two methods for collecting blood for measuring antibody activity of Pasteurella multocida were compared. Whole blood was collected on filter-paper strips, dried for 48 hr at room temperature, and then stored in sealed plastic bags at 4 C. Blood was also collected in the usual manner with a needle and syringe, and serum was harvested and stored at -20 C until tested. Eluates of whole blood, obtained by overnight elution of two 4.8-mm discs in 200 microliters of buffered saline at 4 C, were compared with conventionally harvested serum for antibody activity by enzyme-linked immunosorbent assay (ELISA). Paired samples, taken from the same bird at the same time, showed no significant difference (P less than 0.05) in antibody activity as measured by absorbance when the disc-elution process itself was considered to be a 1:20 dilution. It was concluded that eluates of blood, derived from whole blood dried on filter-paper strips, may be used as an alternative to sera in ELISA for measuring P. multocida antibody activity.  相似文献   

18.
The purpose of this study was to evaluate the performance of the indirect enzyme immunoassay (IELISA) and the competitive enzyme immunoassay (CELISA) for the diagnosis of bovine brucellosis in comparison to conventional serological tests routinely used in Argentina. Serum samples (n = 3500), from Brucella-free herds, from vaccinated cattle and from naturally infected cattle, were tested by the following tests: buffered antigen agglutination test (BPAT), rose bengal test (RBT), 2-mercaptoethanol test (2-ME), complement fixation test (CFT), IELISA and CELISA. Sensitivity and specificity of the BPAT, RBT, IELISA and CELISA were determined relative to the 2-ME and the CFT. The CELISA was considered suitable for eliminating most serological reactions of vaccinated animals and was more specific than the other tests. The results indicate the potential use of the CELISA as a complementary assay in the brucellosis control and eradication program in Argentina and other countries, where Brucella abortusstrain 19 vaccination is mandatory.  相似文献   

19.
The biological and psychological significance of oxytocin is increasingly recognized; however, reliable assays of oxytocin in biological samples have not been developed. We raised a new oxytocin polyclonal rabbit antibody against synthetic oxytocin. The affinity of antibodies to oxytocin was examined by a radio-immunoassay and compared with that of a previously validated antibody. One antibody showed affinity for oxytocin in the radio-immunoassay. We developed a solid-phase ELISA for oxytocin using this antibody and compared it with existing methods. The newly developed ELISA showed comparable results using urine samples but not using serum samples. These results indicate that the new ELISA is useful for urinary oxytocin; further modifications, such as different extraction methods, are needed for its application to serum oxytocin.  相似文献   

20.
Ninety dogs naturally infected with Dirofilaria immitis and 103 noninfected dogs, as determined by necropsy, were used to compare the sensitivity and specificity of the cuticular and somatic reactions of the indirect fluorescent antibody test (IFA-C and IFA-S, respectively) and 2 enzyme-linked immunosorbent assays (ELISA). In microfilaremic and amicrofilaremic heartworm-infected dogs, negative results were common for all serotests. In dogs without adult heartworms at necropsy, 32% to 49% were positive, using 1 ELISA, 27% to 29% were positive with the other ELISA, 15% to 36% were positive with the IFA-S, and 0% to 1% were positive using the IFA-C, depending on the classification of borderline reactions. The prevalence of false positive serotests was probably not due to the detection of precardial stages of D immitis in dogs obtained from areas of low endemicity. Until the causes of the false-positive tests are resolved, the use of currently available serotests for routine diagnostic screening or as criteria for instituting treatment is not recommended.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号