首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The objective of this study is to investigate the effect of cyclosporin A (CsA) on baroreceptor reflex and renal function. Fifteen male mongrel dogs weighing 13-18 kg were divided into three groups and were treated orally as follows: group 1, enalapril 0.5 mg/kg per day for 10 days; group 2, CsA 20 mg/kg per day for 7 days; group 3, enalapril 0.5 mg/kg per day for 3 days combined with CsA 20 mg/kg per day for 7 more days. Measurements of blood pressure and of baroreflex response to sodium nitroprusside (SNP) and phenylephrine (PE) and renal function studies were performed on the days before and after receiving drugs. In group 1, both systolic arterial pressure (SAP) and mean arterial pressure (MAP) were unaltered, while diastolic arterial pressure (DAP) was reduced significantly. In group 2, all pressures (SAP, MAP and DAP) increased significantly. Group 3 showed no change in blood pressure. Studies of baroreceptor reflex showed that only dogs in group 2 had decreased sensitivity to PE without changing the setpoint. No change of the reflex was found in other groups. Renal function studies were unaltered in all groups. The data indicate that CsA increased blood pressure, which may be due to decreased baroreceptor reflex sensitivity mediated via activation of the renin-angiotensin-aldosterone system.  相似文献   

2.
OBJECTIVE: To examine the agreement between direct arterial blood pressure measurements obtained from 2 arteries and indirect blood pressure measurements obtained with an oscillometric blood pressure monitor (OBPM) during normotension and phenylephrine-induced hypertension in dogs. ANIMALS: 16 male Beagles. PROCEDURES: In anesthetized dogs, arterial catheters were placed in the lingual and dorsal pedal arteries for measurement of arterial blood pressure. A blood pressure cuff was placed on either the dog's fore- or hind limb and connected to an OBPM. Systolic, diastolic, and mean arterial blood pressures (SAP, DAP, and MAP, respectively) were recorded from both arteries and the OBPM every 5 minutes for 30 minutes (baseline), during a 30-minute period in which dogs received a phenylephrine infusion IV to induce hypertension, and for 30 minutes after discontinuation of the infusion. Mean differences in blood pressure values and confidence intervals were calculated to compare the indirect and direct measurement techniques. RESULTS: In dogs, oscillometry underestimated SAP during normotension, and the difference between oscillometric and direct measurements increased during hypertension. Oscillometry underestimated DAP, but the difference between oscillometric and direct measurements decreased during hypertension. There was close agreement among techniques for MAP determinations. Biases between direct measurements and OPBM blood pressure values measured from dogs' forelimbs or hind limbs were not significantly different. CONCLUSIONS AND CLINICAL RELEVANCE: In normotensive dogs, oscillometric measurements of MAP and SAP agreed more closely with direct arterial pressure measurements than oscillometric estimates of DAP. Oscillometric measurement of MAP was accurate during both normotension and hypertension in dogs.  相似文献   

3.
Objective: To determine the cardiovascular effects of desflurane in dogs following acute hemorrhage. Design: Experimental study. Animals: Eight mix breed dogs. Interventions: Hemorrhage was induced by withdrawal of blood until mean arterial pressure (MAP) dropped to 60 mmHg in conscious dogs. Blood pressure was maintained at 60 mmHg for 1 hour by further removal or replacement of blood. Desflurane was delivered by facemask until endotracheal intubation could be performed and a desflurane expiratory end‐tidal concentration of 10.5 V% was maintained. Measurements and main results: Systolic, diastolic, and mean arterial blood pressure (SAP, DAP and MAP), central venous pressure (CVP), cardiac output (CO), stroke volume (SV), cardiac index (CI), systemic vascular resistance (SVR), heart rate (HR), respiratory rate (RR), partial pressure of carbon dioxide in arterial blood (PaCO2), and arterial pH were recorded before and 60 minutes after hemorrhage, and 5, 15, 30, 45 and 60 minutes after intubation. Sixty minutes after hemorrhage, SAP, DAP, MAP, CVP, CO, CI, SV, PaCO2, and arterial pH decreased, and HR and RR increased when compared with baselines values. Immediately after intubation, MAP and arterial pH decreased, and PaCO2 increased. Fifteen minutes after intubation SAP, DAP, MAP, arterial pH, and SVR decreased. At 30 and 45 minutes, MAP and DAP remained decreased and PaCO2 increased, compared with values measured after hemorrhage. Arterial pH increased after 30 minutes of desflurane administration compared with values measured 5 minutes after intubation. Conclusions: Desflurane induced significant changes in blood pressure and arterial pH when administered to dogs following acute hemorrhage.  相似文献   

4.
In a series of 3 studies, indirect blood pressure measurements were obtained to define normal variance, identify hypertension, and estimate the prevalence of hypertension in apparently healthy dogs. In part 1, we measured values in 5 clinically normal dogs twice weekly for 5 weeks in a home setting. Mean +/- SD systolic arterial pressure (SAP) and diastolic arterial pressure (DAP) was 150 +/- 16 and 86 +/- 13 mm of Hg, respectively. The DAP significantly (P less than 0.01) decreased with repeated measurements over the 5-week period. In part 2, we assessed the variation between blood pressures measured in a clinic vs those measured in the home. Within a 2-week period, measurements were obtained from 10 clinically normal dogs in a private veterinary clinic and again in their home. Significant differences were not observed between clinic and home measurements of SAP and DAP; however, heart rate was significantly (P less than 0.05) higher in the clinic. In part 3, SD about the SAP and DAP mean values were determined in 102 clinically normal dogs. Canine hypertensive status was determined, using statistical methods and data from 102 clinically normal dogs. Values of SAP greater than 202 mm of Hg and DAP greater than 116 mm of Hg were determined to be 2 SD beyond the mean and, therefore, were interpreted to be hypertensive. Approximately 10% of the 102 apparently healthy dogs measured in this study were considered hypertensive on the basis of these criteria. In addition, a border zone of suspected hypertension was estimated, using the mean + 1.282 SD. The SAP border zone was between 183 and 202 mm of Hg, whereas the DAP border zone was between 102 and 113 mm of Hg. Of the 102 dogs, 12 had values within these zones of suspected hypertension.  相似文献   

5.
ObjectiveTo compare high definition oscillometry (HDO) to invasive blood pressure measurement in anaesthetized dogs.Study designProspective, clinical trial.AnimalsFifty dogs weighing 1.95–79 kg (mean 23.5 kg).Materials and methodsAnaesthetic and peri–anaesthetic management was chosen according to each dog's physical status and anaesthetist's preference. Direct arterial blood pressure measurements were performed using a catheter placed in the dorsal pedal artery and an electronic pressure transducer connected to a multiparameter monitor. Non–invasive blood pressure measurements were performed using an appropriately sized cuff placed around the tail base. Comparisons between the two methods were made using Bland and Altman plots. The data are reported as mean bias (lower, upper limits of agreement). Further analysis was performed after separating the data into the following categories based on invasive mean arterial blood pressure (MAP): high (MAP > 100 mmHg), medium (70 mmHg < MAP < 100 mmHg) and low (MAP < 70 mmHg) blood pressure (BP). The two methods were compared as used clinically.ResultsEight hundred measurement pairs for invasive and HDO BP readings were compared. Overall, the HDO measured lower values for SAP and DAP but higher for MAP than the invasive method. The lowest bias (upper, lower limits of agreement) were obtained for MAP, ?1 (?22, 19) mmHg. The biggest discrepancy between the methods was reflected by a large bias (limits of agreement) 5 (?34, 45) mmHg, was for SAP. The results for DAP were between those for SAP and MAP with a bias (limits of agreement) of 3 (?20, 27) mmHg. When the values were separated into the pressure range categories the HDO measured higher in the high, medium and low BP groups, with the exception of SAP in the low BP group.ConclusionsWhen considering the mean bias, the accuracy of HDO compared well with direct arterial blood pressure, but the precision was poor, as determined by wide limits of agreement.Clinical relevanceUsing trends and serial measurements rather than a single measurement for clinical decision making is recommended with both methods, when used as reported here.  相似文献   

6.
This study was performed to determine the cardiovascular responses to isoflurane in euthyroid and hypothyroid dogs. Four healthy mixed-breed dogs were studied prior to thyroidectomy (PRE), 6 months after thyroidectomy (HYP), and after 2 months of oral supplementation with 1-thyroxine (SUP). Heart rate (HR), cardiac output (), stroke volume (SV), systolic, diastolic, mean arterial blood pressure (SAP, DAP, MAP), and total peripheral resistance (TPR) were determined in awake dogs and in the same dogs when end-tidal isoflurane concentrations were 1.28%, 1.92%, and 2.56%. Ventilation was controlled in anesthetized dogs and Paco2 maintained between 38 to 42 mm Hg. Isoflurane caused significant ( P <.05) dose-dependent reduction in , SV, SAP, DAP, and MAP in the PRE, HYP, and SUP dogs. Cardiac output was lower in the HYP dogs than in the PRE or SUP dogs during awake measurement. TPR was increased in the awake HYP dogs compared with the PRE or SUP dogs. During anesthesia, HYP dogs tended to have lower , SV, SAP, and MAP than the PRE or SUP groups, but the only significant reduction was SAP during 1.5 MAC. The cardiovascular responses to isoflurane in hypothyroid dogs are similar to euthyroid animals with a dose-dependent depression in , SV, and arterial pressure.  相似文献   

7.
OBJECTIVE: To compare the performance of the Surgivet Non-Invasive Blood Pressure (NIBP) monitor V60046 with an invasive blood pressure (IBP) technique in anaesthetized dogs. STUDY DESIGN: A prospective study. ANIMALS: Thirty-four dogs, anaesthetized for a variety of procedures. METHODS: Various anaesthetic protocols were used. Invasive blood pressure measurement was made using a catheter in the femoral or the pedal artery. A cuff was placed on the contralateral limb to allow non invasive measurements. Recordings of arterial blood pressures (ABPs) were taken at simultaneous times for a range of pressures. For analysis, three pressure levels were determined: high [systolic blood pressure (SAP) > 121 mmHg], normal (91 mmHg < SAP < 120 mmHg) and low (SAP < 90 mmHg). Comparisons between invasive and non invasive measurements were made using Bland-Altmann analysis. RESULTS: The NIBP monitor consistently underestimated blood pressure at all levels. The lowest biases and greatest precision were obtained at low and normal pressure levels for SAP and mean arterial pressure (MAP). At low blood pressure levels, the biases +/- 95% confidence interval (CI) were 1.9 +/- 2.96 mmHg (SAP), 8.3 +/- 2.41 mmHg diastolic arterial pressure (DAP) and 3.5 +/- 2.09 mmHg (MAP). At normal blood pressure levels, biases and CI were: 1.2 +/- 2.13 mmHg (SAP), 5.2 +/- 2.32 mmHg (DAP) and 2.1 +/- 1.54 mmHg (MAP). At high blood pressure levels, the biases and CI were 22.7 +/- 5.85 mmHg (SAP), 5.5 +/- 3.13 mmHg (DAP) and 9.4 +/- 3.52 mmHg (MAP). In 90.6% of cases of hypotension (MAP < 70 mmHg), the low blood pressure was correctly diagnosed by the Surgivet. CONCLUSIONS: Measurement of blood pressure with the indirect monitor allowed detection of hypotension using either SAP or MAP. The most accurate readings were determined for MAP at hypotensive and normal levels. The monitor lacked accuracy at high pressures. CLINICAL RELEVANCE: When severe challenges to the cardiovascular system are anticipated, an invasive method of recording ABP is preferable. For routine usage, the Surgivet monitor provided a reliable and safe method of NIBP monitoring in dogs, thereby contributing to the safety of anaesthesia by providing accurate information about the circulation.  相似文献   

8.
Cardiovascular effects of topical ophthalmic 10% phenylephrine in dogs   总被引:1,自引:1,他引:0  
Objective To evaluate the effect of topical ophthalmic 10% phenylephrine on systolic arterial pressure (SAP), diastolic arterial pressure (DAP), mean arterial pressure (MAP), pulse rate (PR) and electrocardiogram (ECG) in dogs. Animals studied Nine clinically normal dogs. Procedure Arterial catheters were placed in the dorsal pedal artery of awake dogs and ECG leads were attached. After a 15‐min acclimatization period, baseline PR, SAP, DAP and MAP were recorded every 5 min for 20 min. Two treatment groups (eight dogs each) were studied. Group I: one drop of phenylephrine was placed in each eye once. Group II: one drop of phenylephrine was placed in each eye three times at 5‐min intervals. Following treatment, PR, SAP, DAP and MAP were recorded every 5 min for 90 min. The mixed procedure of the SAS system was used to perform a repeated measures analysis of variance to test for linear and quadratic trends across time. Results Group I: There was a significant quadratic decrease in PR across time (P = 0.0051). Systolic arterial pressure increased linearly with time (P = 0.0002), MAP increased linearly with time (P = 0.0131), and DAP increased linearly with time (P = 0.0001). Group II: There was a significant quadratic decrease in PR across time (P = 0.0023). There was a significant quadratic increase in SAP (P = 0.0324), MAP (P = 0.0103) and DAP (P = 0.0131) across time. Conclusions Topical ophthalmic application of 10% phenylephrine in normal dogs results in elevation of arterial blood pressure and reflex bradycardia.  相似文献   

9.
The objective of this paper was to evaluate romifidine as a pre-medicant in dogs prior to propofol-isoflurane anaesthesia, and to compare it with medetomidine. For this, eight healthy dogs were anaesthetised. Each dog received three pre-anaesthetic protocols: R40 (romifidine, 40 microg/kg, IV), R80 (romifidine, 80 microg/kg, IV) or MED (medetomidine, 10 microg/kg, IV). Induction of anaesthesia was delivered with propofol and maintained with isoflurane. The following variables were studied before sedative administration and 10 min after sedative administration: heart rate (HR), mean arterial pressure (MAP), systolic arterial pressure (SAP) and diastolic arterial pressure (DAP) and respiratory rate (RR). During maintenance, the following variables were recorded at 5-min intervals: HR, MAP, SAD, DAP, arterial oxygen saturation (SpO(2)), end-tidal CO(2)(EtCO(2)), end-tidal concentration of isoflurane (EtISO) required for maintenance of anaesthesia and tidal volume (TV). Time to extubation, time to sternal recumbency and time to standing were also registered. HR and RR experimented a significantly decreased during sedation in all protocols respect to baseline values. Mean HR, MAP, SAP, DAP, SpO(2), EtCO(2), and TV during anaesthesia were similar for the three protocols. End tidal of isoflurane concentration was statistically similar for all protocols. Recovery time for R40 was significantly shorter than in R80 and MED. The studied combination of romifidine, propofol and isoflurane appears to be an effective drug combination for inducing and maintaining general anaesthesia in healthy dogs.  相似文献   

10.
ObjectiveTo evaluate the agreement between invasive blood pressure (IBP) and Doppler ultrasound blood pressure (DUBP) using three cuff positions and oscillometric blood pressure (OBP) in anesthetized dogs.Study designProspective study.AnimalsNine adult dogs weighing 14.5–29.5 kg.MethodsThe cuff was placed above and below the tarsus, and above the carpus with the DUBP and above the carpus with the OBP monitor. Based on IBP recorded via a dorsal pedal artery catheter, conditions of low, normal, and high systolic arterial pressures [SAP (mmHg) <90, between 90 and 140, and >140, respectively] were induced by changes in isoflurane concentrations and/or dopamine administration. Mean biases ± 2 SD (limits of agreement) were determined.ResultsAt high blood pressures, regardless of cuff position, SAP determinations with the DUBP underestimated invasive SAP values by more than 20 mmHg in most instances. With the DUBP, cuff placement above the tarsus yielded better agreement with invasive SAP during low blood pressures (0.2 ± 16 mmHg). The OBP underestimated SAP during high blood pressures (?42 ± 42 mmHg) and yielded better agreement with IBP for mean (MAP) and diastolic (DAP) arterial pressure measurements [overall bias: 2 ± 15 mmHg (MAP) and 0.2 ± 16 mmHg (DAP)].ConclusionsAgreement of SAP determinations with the DUBP is poor at SAP > 140 mmHg, regardless of cuff placement. Measurement error of the DUBP with the cuff placed above the tarsus is clinically acceptable during low blood pressures. Agreement of MAP and DAP measurements with this OBP monitor compared with IBP was clinically acceptable over a wide pressure range.Clinical relevanceWith the DUBP device, placing the cuff above the tarsus allows reasonable agreement with IBP obtained via dorsal pedal artery catheterization. Only MAP and DAP provide reasonable estimates of direct blood pressure with the OBP monitor evaluated.  相似文献   

11.
Twenty-four dogs with induced, severe chronic renal failure were allotted to 2 groups of 12 each. Group-A dogs were fed a 0.4% phosphorus (P)/0.6% calcium, 32% protein diet, and group-B dogs were fed a 1.4% P/1.9% calcium, 32% protein diet. Dogs were studied over 24 months to determine clinical status, survival, blood biochemical alterations, glomerular filtration rate (GFR), urinary excretion of P and protein, renal morphologic changes, and renal tissue concentrations of calcium, P, and magnesium. Group-A dogs developed statistically significant differences from group-B dogs in several blood biochemical values (PCV and total solids, calcium, P, potassium, sodium, chloride, total CO2 (TCO2), anion gap, and parathyroid hormone concentrations) and in urinary P excretion. Mean (+/- SEM) GFR values in group-A and group-B dogs were nearly identical when diets were initiated (group A = 0.73 +/- 0.05 ml/min/kg of body weight; group B = 0.72 +/- 0.08 ml/min/kg), but significantly (P = 0.0346) lower GFR developed in group-B than in group-A dogs over time. At 24 months, GFR in survivors was 0.83 +/- 0.08 and 0.63 +/- 0.15 ml/min/kg for dogs of groups A and B, respectively. Other measurements favored the hypothesis that P/calcium restriction was beneficial, but values failed to reach statistical significance. Survival was greater at 24 months in group-A than in group-B (7 vs 5) dogs, and renal tissue concentrations of calcium and P were higher in group-B than in group-A dogs. Differences were not detected between groups in urinary excretion of protein and in the type or severity of renal lesions.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

12.
Proteinuria and systemic hypertension are well recognised risk factors in chronic renal failure (CRF). They are consequences of renal disease but also lead to a further loss of functional kidney tissue. The objectives of this study were to investigate the associations between proteinuria, systemic hypertension and glomerular filtration rate (GFR) in dogs with naturally occurring renal and non-renal diseases, and to determine whether proteinuria and hypertension were associated with shorter survival times in dogs with CRF. Measurements of exogenous creatinine plasma clearance (ECPC), urine protein:creatinine ratio (UPC), and Doppler sonographic measurements of systolic blood pressure (SBP) were made in 60 dogs with various diseases. There was a weak but significant inverse correlation between UPC and ECPC, a significant inverse correlation between SBP and ECPC and a weak but significant positive correlation between UPC and SBP. Some of the dogs with CRF were proteinuric and almost all were hypertensive. Neoplasia was commonly associated with proteinuria in the dogs with a normal ECPC. CRF was the most common cause leading to hypertension. In the dogs with CRF, hypertension and marked proteinuria were associated with significantly shorter survival times.  相似文献   

13.
Objective To use the American College of Veterinary Internal Medicine (ACVIM) validation criteria to evaluate the performance of high definition oscillometric (HDO) and Doppler blood pressure measurement techniques against invasive blood pressure measurements in anaesthetized dogs. Study design Prospective clinical study. Animals Twenty client‐owned dogs. Materials and Methods Invasive blood pressure was measured using a catheter inserted into a pedal artery and an electronic transducer. The sites of cuff placement for the HDO measurements were the mid antebrachium or the proximal tail and, for the Doppler technique, the distal tibia. Agreement between invasive and non‐invasive blood pressure measurements was estimated by the Bland–Altman method. Results Only 10% and 34% of Doppler measurements were within 10 and 20 mmHg of invasive blood pressure values, respectively. The Doppler device failed to meet the ACVIM validation criteria for blood pressure measurement devices. The best agreement between HDO and invasive blood pressure measurement technique was observed for mean arterial blood pressure (MAP); 67% and 95% of readings were within 10 and 20 mmHg of invasive blood pressure values respectively. In addition, 52% and 87% of diastolic arterial blood pressure (DAP) measurements were within 10 and 20 mmHg of invasive readings. High definition oscillometric readings did not meet ACVIM recommended limits for SAP. Conclusion and clinical relevance The Doppler technique overestimated and the HDO device showed limited agreement with invasive blood pressure measurement in anaesthetized dogs. High definition oscillometry met most of the ACVIM requirements for MAP and DAP while the Doppler technique did not.  相似文献   

14.
The urinary enzyme markers of renal damage, alkaline phosphatase (AP), gamma-glutamyl transferase (GGT) and N-acetyl-beta-glucosaminidase (NAG), glomerular filtration rate (GFR) and renal biopsies were studied to evaluate renal status in dogs with pyometra. After ovariohysterectomy, urinary enzymes were measured daily for 12 days in 55 dogs, and again at a later follow-up visit. Thirteen dogs had high levels of at least one enzyme at initial presentation. Seventeen dogs had a transient increase in urinary enzyme values between one and five days after surgery. Enzyme values usually declined to low activities within 12 post-operative days. Renal biopsies demonstrated tubular abnormalities in many dogs. Mean GFR was 2.4 and 2.0 ml min(-1) kg(-1), respectively on day 1 post-operatively and at the follow-up visit 1-4 months later. High urinary enzyme values often reflected extensive lesions in renal proximal tubular cells and sometimes reduced GFR.  相似文献   

15.
Oscillometric blood pressure monitoring may be a practical tool for short procedures or those performed outside of the operating room. Oscillometric and direct blood pressure values in 30 juvenile and adult horses in a clinical setting using mixed effect models were compared. The limits of agreement and percentage errors were also calculated. We evaluated the sensitivity and false positive rate for the oscillometric method to trigger an intervention for treating blood pressure [direct mean arterial pressure (MAP) < 70 mmHg]. Oscillometric MAP and diastolic arterial pressure (DAP) differed from direct values (P < 0.001); systolic arterial pressure (SAP) did not (P = 0.08). Wide limits of agreement were observed. Percentage errors were smaller for SAP (39%) than for MAP and DAP (48% and 72%). The oscillometric monitor indicated there was a requirement for blood pressure treatment with a true positive rate of 82%, consequently, it failed 18% of the times. The false positive rate (unnecessary treatment) was 55%.  相似文献   

16.
BACKGROUND: Glomerular filtration rate (GFR) measurement is an indicator of kidney function. However, its usefulness in dogs at early stages of spontaneous chronic kidney disease (CKD) of glomerular origin, where routine laboratory techniques are not sufficiently sensitive, remains unproved. HYPOTHESIS: That GFR is reduced in proteinuric nonazotemic or mildly azotemic dogs with CKD secondary to leishmaniasis. ANIMALS: Twenty-six dogs with CKD secondary to leishmaniasis and 10 healthy dogs (control group). METHODS: CBC, serum biochemistry, and urinalysis (microalbuminuria and urine protein/creatinine ratio [UPC]) were performed in all dogs. GFR was calculated by measuring exogenous creatinine clearance. Based on degree of proteinuria and serum creatinine concentration (SCr), dogs were classified as group A (control; n = 10): UPC < 0.2, SCr < 1.4 mg/dL; group B (n = 8): UPC, 0.2-0.5, SCr < 1.4 mg/dL; group C (n = 10): UPC > 0.5, SCr < 1.4 mg/dL; group D (n = 5): SCr, 1.4-2 mg/dL; group E (n = 3): SCr > 2 mg/dL. Results: GFR (mL/kg/min) was 3.9 +/- 0.29, 4.4 +/- 0.74, 4.5 +/- 1.44, 2.8 +/- 0.97, and 1.5 +/- 0.43 for groups A, B, C, D, and E, respectively. Eleven dogs (1 from group B, 3 from group C, 4 from group D, and all 3 dogs from group E) had an abnormally low GFR. Four dogs from group B and 5 dogs from group C had a GFR above the upper reference range (>4.5 mL/min/kg). CONCLUSION AND CLINICAL RELEVANCE: Some proteinuric nonazotemic or mildly azotemic dogs with leishmaniasis have low GFR, but glomerular hyperfiltration occurs in other dogs.  相似文献   

17.
OBJECTIVE: To determine accuracy of an oscillometric blood pressure monitor used over a wide range of pressures in anesthetized cats. DESIGN: Prospective study. ANIMALS: 6 healthy cats. PROCEDURE: 4 female cats and 2 male cats that weighed 2.7 to 4.5 kg (5.9 to 9.9 lb) and were 2 to 8 years old were anesthetized. Blood pressure was measured directly with an arterial catheter placed in the right femoral artery and indirectly from the left antebrachium by use of an oscillometric monitor. A series of diastolic arterial pressure (DAP), mean arterial pressure (MAP), and systolic arterial pressure (SAP) measurements were obtained during hypotension, normotension, and hypertension. Values obtained indirectly and directly were compared. RESULTS: The oscillometric monitor was accurate for DAP and MAP throughout the entire pressure range and met the standards of the Association for the Advancement of Medical Instrumentation (mean +/- SD difference from values obtained directly, < or = 5 +/- 8 mm Hg). The SAP was increasingly underestimated with increasing overall pressure; mean differences from direct measurements were -5.2, -12.1, and -17.7 mm Hg during hypo-, normo-, and hypertension, respectively. Standard deviations for SAP were all < or = 8 mm Hg. The monitor gave readings during all attempts. The direct blood pressure recording system appeared to perform well with neither under- nor overdamping. CONCLUSIONS AND CLINICAL RELEVANCE: Except for a minor underestimation of SAP during normo- and hypertension, the oscillometric monitor yielded reliable and easily obtainable blood pressure measurements in anesthetized cats.  相似文献   

18.
OBJECTIVE: To investigate the effects of IM administration of acepromazine on indices of relative renal blood flow and glomerular filtration rate (GFR) by means of scintigraphy, as well as the effects on physiologic, hematologic, and serum biochemical variables in anesthetized dogs, compared with effects of administration of saline. ANIMAL: 6 healthy Beagles. PROCEDURE: Acepromazine (0.1 mg/kg) or physiologic saline (0.9 NaCI) solution was administered IM 30 minutes prior to induction of anesthesia with thiopentone; anesthesia was maintained with inspired isoflurane for 2.25 hours. Blood gases and circulatory and ventilatory variables were monitored. Renal function was evaluated by scintigraphic measurements of GFR and relative renal blood flow and analyses of serum and urine. Statistical analyses used ANOVA or Friedman ANOVA. RESULTS: Values of relative renal blood flow and GFR remained high despite low blood pressures. After administration of acepromazine, mean +/- SD arterial blood pressure was 66 +/- 8 mm Hg during anesthesia; this value was below the threshold (80 mm Hg) for renal autoregulation of GFR. In comparison, mean arterial blood pressure after administration of saline was significantly higher (87 +/- 13 mm Hg). However, between treatments, there were no significant differences in GFR, relative renal blood flow, or other indices of renal function. CONCLUSIONS AND CLINICAL RELEVANCE: Measurements of renal function and blood flow in dogs during anesthesia with thiopentone and isoflurane did not differ significantly between treatments, which suggested that acepromazine protects renal function despite inducing reduction in blood pressure, compared with effects of administration of saline.  相似文献   

19.
ObjectiveTo determine the accuracy of an oscillometric blood pressure monitor in anesthetized sheep.Study designProspective study.AnimalsTwenty healthy adult sheep, 11 males and nine females, weighing 63.6 ± 8.6 kg.MethodsAfter premedication with buprenorphine or transdermal fentanyl, anesthesia was induced with ketamine‐midazolam and maintained with isoflurane and ketamine, 1.2 mg kg?1 hour?1, ± lidocaine, 3 mg kg?1 hour?1. Invasive blood pressure measurements were obtained from an auricular arterial catheter and noninvasive measurements were from a cuff on the metatarsus or antebrachium. Simultaneous invasive and noninvasive measurements were recorded over a range (55–111 mmHg) of mean arterial pressures (MAP). Isoflurane concentration was increased to decrease MAP and decreasing the isoflurane concentration and infusing dobutamine achieved higher pressures. Invasive and noninvasive measurements were compared.ResultsCorrelation (R2) was good between the two methods of measurement (average of three consecutive readings) for systolic (SAP) (0.87), diastolic (DAP) (0.86), and mean (0.90) arterial pressures (p < 0.001). Bias ± SD between noninvasive and invasive measurements for SAP was 3 ± 8 mmHg, for DAP was ?10 ± 7 mmHg, and MAP was ?7 ± 6 mmHg. There was no significant difference between the average of three measurements and use of the first measurement. Correlations using the first measurement were SAP (0.82), DAP (0.84), and MAP (0.89). Bias ± SD for SAP was 3 ±10 mmHg, for DAP was ?11 ± 7 mmHg, and MAP was ?7 ± 6 mmHg. The oscillometric monitor slightly overestimated SAP and underestimated DAP and MAP for both average values and the first reading.Conclusions and clinical relevanceThis oscillometric model provided MAP measurements that were acceptable by ACVIM standards. MAP measurements with this monitor were lower than those found with the invasive technique so a clinical diagnosis of hypotension may be made in sheep that are not hypotensive.  相似文献   

20.
Background: Greyhounds are known to have a higher systemic arterial blood pressure (BP) than non‐Greyhound dogs. Objectives: The purpose of this study was to determine whether the high systemic BP was because of the white‐coat effect. Animals: Twenty‐two healthy retired racing Greyhounds (RRG) enrolled in a blood donation program. Materials/Methods: We prospectively measured systemic BP in 3 environments: in the hospital by the investigator (Hosp), in the home by the investigator (H/I), and in the home by the owner (H/O). Five serial measurements of systolic, diastolic, and mean arterial pressures (SAP, DAP, MAP) as well as heart rate (HR) were measured by an oscillometric method on the distal forelimb and distal hind limb in all 3 environments. Results: There was a significant difference for SAP, MAP, and HR between the Hosp and both H/I and H/O (P < .001); there were no significant differences for any of the parameters between the H/I and H/O environments. HR, but not SAP, MAP, or DAP (P < .05) decreased in RRG with multiple hospital visits for blood donation before this study. The hind limb SAP was significantly higher than the forelimb SAP (P < .05). Conclusions and Clinical Importance: We conclude that the high SAP, MAP, and HR seen in the hospital setting are likely because of a white‐coat effect. Furthermore, consideration should be given to defining the parameters of normal BP in RRG according to the environment in which they are obtained.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号