ObjectivesTo evaluate the agreement between high-definition oscillometry (HDO) used on the metatarsus or tail base with invasive arterial blood pressures measured in the dorsal pedal artery in anaesthetised cheetahs.Study DesignProspective clinical study.AnimalsA group of 13 captive adult cheetahs.MethodsCheetahs were immobilised with medetomidine (32–45 μg kg–1) and tiletamine/zolazepam (0.93–1.39 mg kg–1) administered intramuscularly, and anaesthesia was maintained with either isoflurane in oxygen or continuous propofol infusion. Invasive blood pressure was measured via a 20 gauge intra-arterial catheter in the dorsal pedal artery in the metatarsus and used as a reference method for pressures simultaneously estimated using HDO on the contralateral metatarsus and tail base. Bland–Altman plots (for repeated measurements) and criteria defined by the American College of Veterinary Internal Medicine (ACVIM) were used to compare agreement according to the anatomical location of the cuff, the anaesthetic maintenance agent and magnitude of the blood pressure.ResultsA total of 147 paired measurements were obtained with HDO on the metatarsus and 135 on the tail. Agreement with invasive pressures was better when HDO was used on the tail (rather than on the metatarsus) with all ACVIM criteria being met. Mean bias (a positive bias meaning that HDO overestimated the invasively measured pressures) ± standard deviation of differences for systolic, diastolic and mean arterial pressures were –7.0 ± 13.9, 4.2 ±12.1 and 4.6 ±11.2 mmHg, respectively, for HDO on the tail, and –11.9 ±15.1, 2.8 ±16.5 and 2.1 ±13.2 mmHg, respectively, for HDO on the metatarsus. Agreement was better during isoflurane anaesthesia than propofol, and at lower blood pressures than at higher.Conclusions and clinical relevanceWhen used on the tail base of anaesthetised cheetahs, HDO met the ACVIM validation criteria for a noninvasive device, as compared to invasively measured pressures in the dorsal pedal artery.  相似文献   

2.
ObjectiveTo use American College of Veterinary Internal Medicine (ACVIM) criteria to evaluate a high-definition oscillometric (HDO) blood pressure monitoring device versus invasive blood pressure (IBP) measurement in normotensive rabbits anaesthetized with two different anaesthetic protocols.Study designProspective experimental study.AnimalsA group of 20 healthy adult New Zealand White rabbits weighing 4.36 ± 0.37 kg (mean ± standard deviation).Materials and methodsRabbits were premedicated with butorphanol 0.5 mg kg–1 and midazolam 0.5 mg kg–1 subcutaneously (SC, group BMA) or ketamine 25 mg kg–1 and medetomidine 0.4 mg kg–1 SC (group KM). Anaesthesia was induced with alfaxalone administered intravenously (group BMA) or isoflurane by face mask (group KM) and maintained with isoflurane in oxygen. IBP was measured from the central auricular artery. The cuff for the HDO monitor was placed distal to the left elbow and distal to the left tarsus. Agreement between invasive and HDO measurements was evaluated using Bland–Altman method.ResultsIn group KM there was better agreement between the HDO device and IBP when the cuff was placed on the thoracic limb, with 100% and 91% of the readings for mean (MAP) and diastolic arterial pressure (DAP), respectively, within 10 mmHg of the IBP measurements. The agreement, although worse, also met the ACVIM criteria for systolic arterial pressure (SAP; 53% of the readings within 10 mmHg). In group BMA, the device met the criteria with the cuff on the thoracic limb only, and only for MAP and DAP (73% and 75% of the measurements within 10 mmHg of the IBP, respectively) but not for SAP (12%).Conclusion and clinical relevanceThe HDO device met most of the ACVIM criteria for noninvasive blood pressure measurement in anaesthetized rabbits, specifically when the cuff was placed distal to the elbow and the anaesthetic protocol included ketamine and medetomidine.  相似文献   

3.

Objective

To determine the agreement of invasive blood pressure measured in the facial, metatarsal and carotid arteries, and evaluate the effects of two haemodynamic conditions on agreement.

Study design

Prospective randomized study.

Animals

A group of eight horses aged 7 (4–23) years with a body weight of 493 ± 33 kg.

Methods

Horses were anaesthetized and positioned in dorsal recumbency. Invasive blood pressure was measured simultaneously via catheters placed in the facial, metatarsal and carotid arteries. Cardiovascular function and agreement between arteries was assessed before and during administration of phenylephrine and sodium nitroprusside. These were administered until carotid mean pressure (MAPc) increased or decreased from baseline (65 ± 5) to >90 or <50 mmHg, respectively. Data recorded at each sample time included systolic (SAP), mean (MAP) and diastolic (DAP) arterial pressures for carotid (c), facial (f) and metatarsal (m) arteries as well as cardiac output (Q˙t) and systemic vascular resistance (SVR). Bland–Altman analysis was used to assess agreement between peripheral and central sites, and regression analysis to determine influence of Q˙t and SVR.

Results

The largest difference was observed in SAPc and SAPm with a bias and limits of agreement (LOA) of 2 (?15 to 19) mmHg. The bias (LOA) for MAPc and MAPf was 2 (?4 to 9) mmHg and for MAPc and MAPm was 5 (?4 to 14) mmHg. The best agreement for DAP was seen between DAPc and DAPf with bias (LOA) of 1 (?3 to 5) mmHg. Regression analysis indicated marginal influence on agreement by Q˙t on MAPc and MAPf.

Conclusions and clinical relevance

MAP and DAP of the carotid artery were higher than those of the peripheral arteries, which may lead to overzealous treatment of hypotension, albeit maintaining central pressures. Q˙t and SVR did not largely influence the difference between sites.  相似文献   

4.
ObjectiveTo assess agreement between oscillometric noninvasive blood pressure (NIBP) measurements using LifeWindow monitors (LW9xVet and LW6000V) and invasive blood pressure (IBP). To assess the agreement of NIBP readings using a ratio of cuff width to mid-cannon circumference of 25% and 40%.Study designProspective, randomized clinical study.AnimalsA total of 43 adult horses undergoing general anesthesia in dorsal recumbency for different procedures.MethodsAnesthetic protocols varied according to clinician preference. IBP measurement was achieved after cannulation of the facial artery and connection to an appropriately positioned transducer connected to one of two LifeWindow multiparameter monitors (models: LW6000V and LW9xVet). Accuracy of monitors was checked daily using a mercury manometer. For each horse, NIBP was measured with two cuff widths (corresponding to 25% or 40% of mid-cannon bone circumference), both connected to the same monitor, and six paired IBP/NIBP readings were recorded (at least 3 minutes between readings). NIBP values were corrected to the relative level of the xiphoid process. A Bland–Altman analysis for repeated measures was used to assess bias (NIBP–IBP) and limits of agreement (LOAs).ResultsThe 40% cuff width systolic arterial pressure [SAP; bias 7.9 mmHg, LOA –26.6 to 42.3; mean arterial pressure (MAP): bias 4.9 mmHg, LOA –28.2 to 38.0; diastolic arterial pressure (DAP): bias 4.2 mmHg, LOA –31.4 to 39.7)] performed better than the 25% cuff width (SAP: bias 26.4 mmHg, LOA –21.0 to 73.9; MAP: bias 15.7 mmHg, LOA –23.8 to 55.2; DAP: bias 10.9 mmHg, LOA –33.2 to 54.9).Conclusions and clinical relevanceUsing the LifeWindow multiparameter monitor in anesthetized horses, the 40% cuff width provided better agreement with IBP; however, both cuff sizes and both monitor models failed to meet American College of Veterinary Internal Medicine Consensus Statement Guidelines.  相似文献   

5.
6.
ObjectiveTo evaluate the agreement between oscillometric blood pressure (OBP) measured from the tongue and invasive blood pressure (IBP), and to compare OBPs measured from the tongue with OBPs measured from the pelvic limb and tail.Study designProspective experimental study.AnimalsA total of eight adult Beagle dogs weighing 11.1 ± 1.2 kg.MethodsAnimals were premedicated with intravenous (IV) acepromazine (0.005 mg kg–1). Anesthesia was induced with alfaxalone (3 mg kg–1) IV and maintained with isoflurane. The dorsal pedal artery was catheterized for IBP measurements. Systolic (SAP), diastolic (DAP) and mean (MAP) arterial pressure were simultaneously measured from the tongue, pelvic limb and tail. Based on invasive SAP, hypertension (>140 mmHg), normotension (90–140 mmHg) and hypotension (<90 mmHg) were induced by controlling end-tidal isoflurane concentrations and/or dobutamine/dopamine administration. Agreement between paired IBP and OBP measurements was analyzed with reference standards for noninvasive blood pressure devices used in small animals and humans.ResultsRegardless of cuff placement, the mean bias ± standard deviation between IBP and OBP met veterinary (≤10 ± 15 mmHg) and human (<5 ± 8 mmHg) standards for MAP and DAP. SAP measurements provided by the OBP device showed unacceptable agreement with IBP, and the bias between methods increased at higher blood pressures, regardless of cuff site. During hypotension, tongue OBP showed the largest percentage of absolute difference <10 mmHg in relation to IBP for SAP (90%), MAP (97%), and DAP (93%), compared with pelvic limb (60%, 97% and 82%, respectively) and tail OBP (54%, 92% and 77%, respectively).Conclusions and clinical relevanceThe tongue is a clinically useful site for measuring OBP in anesthetized Beagle dogs, providing reliable estimates of MAP and DAP. The tongue could replace other cuff placement sites and may be a relatively suitable site for assessing hypotension.  相似文献   

7.
Objective – To compare blood pressure measurements obtained via ultrasonic Doppler flow monitor (DOP) and 2 oscillometric noninvasive blood pressure monitors (CAR and PAS) to invasive blood pressure (IBP) in hospitalized, conscious dogs with a range of blood pressures. Design – Prospective clinical study. Setting – University teaching hospital. Animals – Eleven client‐owned dogs aged between 4 months and 11.5 years (median 6 y), and weighing between 5.8 and 37.5 kg (median 30.2 kg). Interventions – Blood pressure measurement. Measurements and Main Results – Three consecutive measurements of systolic, diastolic, and mean arterial pressure (MAP) were recorded for each of the 3 indirect devices (only systolic for DOP), along with concurrent IBP measurements. The data were categorized into 3 groups: hypotensive (direct MAP<80 mm Hg), normotensive (80 mm Hg≤direct MAP≥100 mm Hg), and hypertensive (direct MAP>100 mm Hg). Each indirect method was compared with the corresponding direct arterial pressure using the Bland‐Altman method. Within the hypotensive group, each indirect method overestimated the corresponding IBP. Within the normotensive group all indirect systolic measurements and the PAS diastolic measurements underestimated the corresponding IBP. The remaining indirect measurements overestimated the corresponding IBP. Within the hypertensive group, DOP and CAR systolic measurements underestimated the corresponding IBP, and the remaining indirect measurements overestimated the corresponding IBP. In hypertensive dogs oscillometric systolic measurements were more accurate than MAP. In hypotensive dogs MAP measurements were more accurate than systolic measurements. All indirect measurements were most accurate in hypertensive dogs. Conclusions – The noninvasive blood pressure monitors in our study did not meet the validation standards set in human medicine. However, CAR diastolic and MAP measurements within the normotensive group, CAR MAP measurements within the hypertensive group, and PAS diastolic measurements in all groups were close to these standards. All indirect measurements showed greater bias during hypotension. Precision was poorer for all indirect systolic measurements than for MAP.  相似文献   

8.
ObjectiveTo assess the agreement between an oscillometric device and invasive blood pressure (IBP) measurements in anesthetized healthy adult guinea pigs.Study designProspective experimental study.AnimalsA total of eight adult Hartley guinea pigs.MethodsAll animals were anesthetized; a carotid artery was surgically exposed and catheterized for IBP measurements. A size 1 cuff placed on the right thoracic limb was connected to an oscillometric device for noninvasive blood pressure (NIBP) assessment. Concurrent pairs of systolic (SAP), diastolic (DAP) and mean (MAP) arterial pressures were recorded simultaneously with both methods every 3 minutes for 30 minutes. Agreement between IBP and NIBP measurements was determined using the Bland–Altman method, considering the recommended standards for the validation of NIBP measurement devices proposed by the American College of Veterinary Internal Medicine (ACVIM).ResultsThe bias and the 95% limits of agreement were: –14 (–31 to 3) mmHg, –2 (–14 to 10) mmHg and –1 (–13 to 11) mmHg for SAP, DAP and MAP, respectively.Conclusions and clinical relevanceThe oscillometric device used in this study to measure NIBP did not meet ACVIM criteria for validation. It showed good agreement for DAP and MAP but not for SAP measurements. Considering the small size of these animals and the resulting difficulty in performing percutaneous arterial catheterization, this device might be a useful tool to assess MAP and DAP during anesthetic procedures in adult guinea pigs.  相似文献   

9.
A 1‐year‐old female spayed mixed‐breed dog was presented for evaluation of acute onset of lethargy and blepharospasm OD. Slit‐lamp biomicroscopy revealed a segmented larva embedded in the inferonasal iris. Moderate anterior uveitis was present. After pharmacologic dilation, mild vitreal hemorrhage and chorioretinal migration tracks were identified. The dog was treated empirically for uveitis for 5 days, after which a keratotomy and larval foreign body extraction was performed. The dog recovered uneventfully from intraocular surgery and remained visual and comfortable. Parasite evaluation confirmed the larva to be a Cuterebra sp. To the authors’ knowledge, this is the first report of canine ophthalmomyiasis interna anterior, and the first report of successful surgical removal from the anterior segment in a dog with preservation of vision.  相似文献   

10.

Objective

To determine agreement between invasive blood pressures measured in three peripheral arteries in anaesthetized horses undergoing elective surgery.

Study design

Prospective balanced incomplete block design.

Animals

A total of 18 client-owned horses.

Methods

Invasive blood pressure (IBP) was measured simultaneously in one of the following three combinations: 1) transverse facial and facial artery; 2) transverse facial and metatarsal artery; and 3) facial and metatarsal artery. The agreement in blood pressure measured for each combination was performed in six horses. At each sample time, systolic (SAP), mean (MAP) and diastolic (DAP) arterial pressures were measured concurrently in each artery, and the mean of three consecutive measurements was recorded. The position of horse, heart rate and use of dobutamine were also recorded. Bland–Altman analysis was used to assess agreement between sites.

Results

A total of 54 paired measurements were obtained, with 18 paired measurements from each combination. All paired measurements showed poor and haphazard (nonsystematic) agreement. The widest limit of agreement was 51 mmHg for SAP measured in the facial artery and metatarsal artery, with a bias of –11 mmHg. The smallest limit of agreement was 16 mmHg for MAP measured in the transverse facial and metatarsal artery, with a bias of 1 mmHg.

Conclusions and clinical relevance

There was poor and haphazard agreement for SAP, MAP and DAP measured in each pair of peripheral arteries in this study. These results show that blood pressure measured in different peripheral arteries cannot be used interchangeably. This has implications for studies that use IBP as an outcome variable and studies determining agreement between noninvasive blood pressure and IBP measurements in horses under general anaesthesia.  相似文献   

11.
12.
A 5‐year‐old spayed female diabetic mixed‐breed dog underwent phacoemulsification and intraocular lens implantation to correct bilateral hypermature cataracts. Two months postsurgery, the patient presented with ulcerative keratitis and multifocal stromal abscessation OD, which was controlled, but never resolved, with topical fluoroquinolone therapy. The patient re‐presented 2 months later with a new, raised, white gritty corneal opacity associated with hyperemia, chemosis, and blepharospasm OD. Cytology of the right cornea revealed filamentous bacteria, suggestive of Actinomyces spp. Actinomyces bowdenii was subsequently isolated in pure culture and identified via 16s rDNA sequencing. Actinomyces bowdenii has never before been described as a cause of ocular infection. An immunosuppressed corneal environment likely contributed to this opportunistic Actinomycosis. The infection was not controlled with fluoroquinolone therapy, and the isolate, in vitro, was resistant to three fluoroquinolones (ciprofloxacin, ofloxacin, and levofloxacin), which also has not been previously reported for this species of Actinomyces. A superficial keratectomy with conjunctival graft was employed to successfully manage the infection.  相似文献   

13.
Systolic, mean and diastolic indirect arterial blood pressures were measured on 8 occasions in 6 sows using a tail cuff and an automatic oscillometry apparatus and compared with direct values. The equations for the regression lines gave the intercepts 31.7 (systole), 20.5 (mean) and 14.2 (diastole) with the regression coefficients 0.97, 0.93 and 0.96 and the correlation coefficients 0.91, 0.93 and 0.95. The significance of cuff bladder width and length and of location and fitting on the tail is discussed. The apparatus offered a simple, reliable method for automatic recording of blood pressures during routine anaesthesia in the sow.  相似文献   

14.
15.
16.
Objective – To determine the accuracy and precision of an oscillometric noninvasive blood pressure device as a predictor of invasive direct blood pressure in healthy anesthetized hypotensive and normotensive dogs. Design – Prospective observational study. Setting – University teaching hospital. Animals – Eight crossbred adult dogs. Interventions – Anesthesia was induced with propofol and maintained with isoflurane. A catheter was placed in the dorsal pedal artery to record systolic, mean, and diastolic arterial blood pressures (aSAP, aMAP, and aDAP, respectively). The noninvasive blood pressure device cuff was placed around the contralateral front limb to record noninvasive systolic, mean, and diastolic blood pressure (nSAP, nMAP, and nDAP). Two states of blood pressure (BP) were studied: baseline state was established by keeping end‐tidal isoflurane concentration at 1.2±0.1%. The hypotensive state was achieved by maintaining the same isoflurane concentration while withdrawing approximately 40% of the animal's blood volume until aMAP was stable at approximately 40 mm Hg. At the end of the study, blood was returned to the animal and it was allowed to recover from anesthesia. Measurements and Main Results – Agreement between the direct and indirect BP measurements was determined by the Bland‐Altman method. The SAP and MAP but not DAP bias varied significantly between each BP state. Normotensive absolute biases (mean [SD]) for SAP, MAP, and DAP were ?14.7 mm Hg (15.5 mm Hg), ?16.4 mm Hg (12.1 mm Hg), and ?14.1 mm Hg (15.8 mm Hg), respectively. Absolute biases during the hypotensive state for SAP, MAP, and DAP were ?32 mm Hg (22.6 mm Hg), ?24.2 mm Hg (19.5 mm Hg), and ?16.8 mm Hg (17.2 mm Hg), respectively. Conclusion – The oscillometric device was not reliably predictive of intra‐arterial BP during hypotension associated with acute hemorrhage.  相似文献   

17.
INTRODUCTION: The aim of this project was to evaluate the reliability and accuracy of direct, using the central ear artery (CEA), and oscillometric, using limb-cuffs, methods of arterial blood pressure (AP) measurement in the anesthetized rabbit. METHODS: New Zealand rabbits were anesthetized using a xylazine-ketamine-isoflurane protocol. Using the abdominal aorta (ABA) as direct "gold standard" for AP measurements, ABA pressure readings, via femoral artery catheterization, were compared with those made simultaneously from the ascending aorta after median sternotomy. Thereafter, direct CEA as well as forelimb-(FL) and hindlimb-(HL) cuff oscillometric readings were compared with those made simultaneously from ABA. RESULTS: The blood pressure in the ABA correlated with that from ascending aorta. Furthermore, CEA correlated with the ABA readings. Nevertheless, at high pressures, their divergence from "true" pressure tended to increase. Oscillometric readings at the FL site correlated well with "true" pressure while those at the HL site did not. Their divergence tended to increase at high pressures when using the FL site, while it varied when using the HL site. The accuracy of measurements was moderate for the FL site while poor for the HL site. DISCUSSION: Our results suggest that the CEA can be readily used with high reliability and accuracy for direct AP measurements in the anesthetized rabbit. On the other hand, the FL-cuff oscillometric method should only be used for the evaluation of AP at low and normal pressure ranges.  相似文献   

18.
19.
Sarcocystidae is a family of coccidian protozoa from the phylum Apicomplexa that includes Toxoplasma, Neospora, Sarcocystis, Hammondia, and Besnoitia spp. All species undergo a 2‐host sexual and asexual cycle. In the definitive host, replication is enteroepithelial, and infection is typically asymptomatic or less commonly causes mild diarrhea. Clinical disease is most frequently observed in the intermediate host, often as an aberrant infection, and is mostly associated with neurologic, muscular, or hepatic inflammation. Here, we review the literature regarding intestinal Sarcocystidae infections in dogs and cats, with emphasis on the life cycle stages and the available diagnostic assays and their limitations. We also report the diagnostic findings for an 11‐year‐old dog with acute neutrophilic hepatitis, biliary protozoa, and negative biliary culture. Although Toxoplasma and Neospora IgG titers were both high, PCR for these 2 organisms was negative for bile. The organisms were identified by 18S rDNA PCR as most consistent with Hammondia, either H heydorni or H triffittae. This is the first report of presumed Hammondia organisms being found in canine bile.  相似文献   

20.